Tender For Additional Works Under Deendayal Panchayat Raj Infrastructure Development Scheme For Construction Of V.P Chicolna Bogmalo Panchayat Ghar And Community Hall In Sy.No. 57/12 And 57/14 In The Village Chicolna Bogmalo
Tender Overview
Project Description
Tender for Additional Works Under Deendayal Panchayat Raj Infrastructure Development Scheme For Construction Of V.P Chicolna Bogmalo Panchayat Ghar And Community Hall In Sy.No. 57/12 And 57/14 In The Village Chicolna Bogmalo
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means over areas for all leads & lifts in all types of strata comprising of any type of materials either in full or part as the case may be adopting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site identified by the contractor and obtaining all statuatory approvals, as directed by engineer for 50m lead and all lifts etc complete. |
| 2 | Earthwork in excavation by mechanical means (hydraulic excavator)/ manual means in foundation/pipeline trenches drains for all leads & lifts in all types of strata comprising of any type of material either in full or part as the case may be adapting any method/methods as may be convenient as permitted (excluding blasting) in all conditions such as dry, moist, foul, saturated, submerged etc. including dressing of sides, planking and strutting, timbering, ramming of bottom, pumping and bailing out water, barricading, danger lighting, guarding and carting away excess excavated earth at the site indentified by the contractor and obtaining all statuatary approvals, as directed by engineer for 50m lead and all lifts etc complete. |
| 3 | Refilling the pipeline/foundation trenches, plinth sides, foundation, etc. with available excavated earth in layers not exceeding 20cm in depth consolidating each layer by ramming and watering lead upto 50m and all lifts and disposal of surplus earth as directed. |
| 4 | Supplying and filling approved earth / hard soil obtained from contractor's identified source inclusive of obtaining all requisites statuatory approvals & observing all the security measures, with all lead and lifts, transporting to site, spreading, grading the earth/hard soil in layers not exceeding 250 mm loose layers, breaking clods & compacting including watering each layer to bring it upto to optimum moisture content to attain dry field density not less than 95% of maximum dry density (Procter Test). (Refer detailed specifications enclosed. The cost of the tests, determination of settlement of natural ground by approved method and cost towards obtaining statutory approvals for cutting/borrowing the earth shall be borne by the contractor) |
| 5 | Disposal of surplus earth & debris upto all leads including loading, unloading and stacking, The site should be identified by the contractor and obtain all statuatory approval. |
| 6 | Providing & laying rubble packing with hard laterite stone under floors including watering ramming and consolidating etc.in pipeline trenches and other foundations complete. |
| 7 | Providing & constructing laterite masonary in neatly dressed stones of size as specified in Cement mortar 1:5 (1cement : 5 coarse sand) in foundation and basement. |
| 8 | Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in cm. 1:5 (1 cement : 5 coarse sand) in foundation upto plinth level. |
| 9 | Providing & constructing laterite masonary in neatly dressed stones for 23 cms masonary walls in c.m 1:4 (1 cement : 4 coarse sand) in super structure from floor I upto floor V level. |
| 10 | Providing & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in - all works upto plinth level |
| 11 | Providing and laying upto floor V level cement concrete 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded granitic or basaltic stone aggregate 20 mm nominal size) including centering and shuttering etc. a) String Courses, copings, bed plates, anchor blocks, plain window sills and the like |
| 12 | a Centering and shuttering including strutting, propping etc. and removal of forms for a) foundation, footings, bases of columns etc. |
| 13 | b) Vertical surfaces such as retaining walls, return walls, Partitions, walls (any thickness) including attached Pilasters, Buttresses, Plinth and string courses, Fillets and the like |
| 14 | c) suspended floors, roofs, landings, shelves and their supports, balconies and chajjas at all levels |
| 15 | Providing TMT steel reinforcement bars of SAIL, TATA. VIZAG, JSW make only (Confirming to IS 1786 of 1986) for RCC work (conforming to I.S. 1786 of 1986) including bending, binding & placing in position in all the floors along with the factory made precast concrete cover blocks of specified sizes whose compressive strength is not less than that of surrounding concrete in the structural member. |
| 16 | Providing and laying in position machine batched concrete (BMC), machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to the site of laying but excluding the cost of centering, shuttering, finishing and reinforcement including admixtures in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing the strength and durability as per the direction of the Engineer. M30 grade of reinforced cement conrete by using 400 kg of cement per cu.m. of concrete. All works at all floor levels. NOTE:- 1.Use of RMC is permitted at no extra cost. 2.Only digital weigh batcher to be used in case of batching at site. |
| 17 | Add for using cement than the quality as provided in the item of batch mix concrete as arrived as per the mix design |
| 18 | Supplying and fixing Pre-cast cement concrete kerb-stones(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) of M-20 with 20 mm nominal size granitic/basaltic aggregate properly consolidated by mechanical plat-form and vibrators with smooth finish including fixing at site complete as per specification. - Size 60 cm L x45 cm H x 15 cm T |
| 19 | Supplying and fixing of Precast RCC slabs(factory made,the factory should be ISO certified and registered under Dirctorate of Industries, Govt. of India) at site in concrete Grade of M-25 with 20 mm nominal size Granitic or basaltic aggregate, consolidated by means of mechanical platform, vibration etc. with lifting hooks of M.s. 10mm bars and PVC cups including cost of reincforcement, Certificate from manufacturer shall be produced indicating grade of concret and minimum content of steel in the product along with 5 year free replacement warranty in case of breakage complete and as directed by Engineer -in -charge. - a) Size 900 x 400 x150 mm with steel reinforcement not less than 7.0 kg per unit - 30T Capacity |
| 20 | b) Size 750 x 400 x100 mm with steel reinforcement not less than 4.2 kg per unit |
| 21 | Providing and fixing MS grill of required pattern in wooden frames of windows, masonry etc with MS flats, square or round bars with round headed bolts and nuts or by screws - Plain grill |
| 22 | Providing beams including hoisting fixing in position & applying wood preservative for unexposed surfaces etc. complete with - Second class matti wood |
| 23 | Steel work welded (SAIL, TATA. VIZAG & using electrodes of Ador or ES4B or Deh Secheron make only) in built up sections trusses and framed work including cutting, hoisting, fixing in position and applying priming coat of red lead paint. - In Tees, angles, flats and channels |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923 /Rectangular Hollow Section (RHS) IS4923/ Circular Hollow Section (CHS) IS1161 closed Structural Steel of approved make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 25 | Supplying and fixing rolling shutters of approved make, made of 80 x 1.25 mm G.M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and G.M.S. top cover of 1.25mm thick for folling shutterstop cover and spring. |
| 26 | Providing and fixing Ball bearings for rolling shutters |
| 27 | Providing & fixing Anodised Aluminium shutters in accordance with the specifications annexed with Goa schedule of rates (2004) Vol I & II including all taxes, transportation, scaffolding and handling etc Complete as per direction of the engineer : Windows with two sliding shutters using 18mm series shutters sections with plain glass including powder coating with pure polyester of required shade and colour. All work between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant. 4 mm thk clear float glass, EPDM gaskets complete with accessories for locking, handles, stoppers, ball bearing etc. |
| 28 | Providing & fixing Anodised Aluminium shutters in accordance with the specifications annexed with Goa schedule of rates (2004) Vol I & II including all taxes, transportation, scaffolding and handling etc Complete as per direction of the engineer : Windows with three sliding shutters using 18mm series shutters sections with plain glass including powder coating with pure polyester of required shade and colour. All work between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant. 4 mm thk clear float glass, EPDM gaskets complete with accessories for locking, handles, stopppers, ball bearing etc. |
| 29 | Providing and fixing Anodized Aluminium shutters in accordance with the specification annexed with Goa schedule of Rates (2004) Vol & II including all taxes, transportation, scaffolding and handling etc. complete as per direction of the Engineer : adjustable louvred windows (louvre blades of thickness 1.20mm) with figured glass including powder coating with pure polyester of required shade and colour. All work between civil work and aluminium frames shall be sealed and made watertight by applying silicone sealant. 4 mm thk figured glass, EPDM gaskets complete with accessories for locking, handles, stopppers etc. |
| 30 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc.with hairline finish, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) |
| 31 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). |
| 32 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels etc. including: a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design. b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc. |
| 33 | c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 34 | Supply and installation of 6mm thick Exterior grade F- Quality panels of standard size of one of the following: 1.3 x 2.8 m /1.854 x 2.8 m / 1.3 x 4.1 m / 1.854 x 4.1 m, with both side décor of FunderMax make or equivalent .The panels must be duromer high-pressure laminates (HPL) as per EN 438-6 type EDF with norm conformity as per EN 438-7 manufactured using NT Technology (Non-fading high performance acrylic polyurethane surface technology) conforming to norms with CE Mark. Panels are double hardened including acrylic polyurethane resin which is thermally cured under high pressure. The panel should have passed salt spray test for 24 hours, possess performance sustainability certificate for more than 25 years and proof of experience in handling similar type of work in India for more than 10 years. Material should be class B / class 1 complying with NBC 2016, ASTM E 84, BS 476 - 7Installation of these panels must be done by MBE Rivets(with Fixed and Sliding Points) with minimum recommended Aluminum T section of 75x37x2 mm thick and L section 40x37x2.8mm thick held by Wall Bracket with Wind load and Dead load slot as per design, anchored by standard Hilti/Fischer or equivalent make anchor fasteners along with Thermal Separator.Installation of the HPL Panels will be done using Rear Ventilated Principles only which is ensured by providing gaps of 20 mm at top and bottom(for free flow of air behind the façade) for the façade and using the framework with no horizontal section. Rate shall include supply of Main exterior panels, Aluminum MBE rivets,supply of Aluminum Substructure (bracket, sections), installation charges, wastages, scaffolding, fabrication. |
| 35 | White glazed tiles 6 mm thick in flooring treads of steps & landings laid on a bed of 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) finished with flush pointing in white cement. |
| 36 | 25mm wooden plank tongued and grooved in flooring including fixing with iron screws complete a) Second class Indian teak wood |
| 37 | Providing & laying 1st quality ceramic glazed wall tiles conforming to IS:15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-charge in skirting, risers of steps and dados jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing in white cement mixed with pigment of matching shade complete. - Wall Ceramic Glazed Tiles : 300 x 450 |
| 38 | Providing and laying factory made Shot blasted cement concrete interlocking paver block of minimum M35 grade made by heavy duty block making machine with strong vibratory compaction and of aprpoved size and design / shape laid in 50 mm thick compacted bed of coarse sand, filling the joints with coarse sand, etc. all complete as per the direction of Engineer.- in I, Wave, Rectangular, Square etc. shapes. The products should comply to IS 15658:2006 and manfucatured by ISO9001: 2008 certified plant. The shot blasting should be done using 0.4-0.5mm dia steel shots with a speed of 3200 rpm.60 mm thick in all colours except grey |
| 39 | Providing water proofing treatment over the new RCC roofs, terrace, sunken slabs, chajjas by spreading cement slurry over the RCC slab and laying of 100 mm average laterite stone ballast coba with the necessary gradient for easy flow of rain water and the coba should be covered with damp proof, joint less water proofing plaster of mix 1:3 (1 cement : 3 Fine sand), finish smooth with wooden trowel with false marking of 30cm squares. the Vertical surfaces of the adjoining walls are to be treated upto a height of 30cms including rounding of junctions (The rate includes for complete items including labour and materials and including the cost of initial treatment of roof slab as follows. The injection of damp proof or equivalent compound with cement solution will be given as and when found necessary for filling honey comb cracks etc. in the RCC slabs) Note: The cement consumption 25 kg /sq.m. |
| 40 | An elastomeric, cementitious, waterproof coating for concrete and masonry. Providing and applying on a well prepared vertical surface Masterseal 550EL of BASF make or equivalent elastomeric flexible, two component polymers modified cementitious composite system that requires no addition of water at the site. The product shall be applied in minimum two coats to achieve total DFT of 1mm. The material shall be mixed and applied fully in accordance with the manufacturer's instructions. The product shall exhibit at least 40% elongation at ambient & 30% elongation in under water condition with tensile strength greater then 20 Kg/cm2. The product shall resist 1.5 bars pressure when tested as per DIN 1048 at 2mm DFT. When applied at 2mm DFT, elastomeric coating shall be able to bridge crack up to 0.5mm width. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete. |
| 41 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24/15x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25/15 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24/15 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer. - GI Metal Ceiling Lay in plain Tegular/ Bevelled edge Global white color tiles of size 595x595 mm, and 0.4-0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100 gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending. |
| 42 | Providing and fixing tiled false ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24/15x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \\"T\\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \\"T\\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25/15 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24/15 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer. - GI Metal Ceiling Lay in perforated Tegular/ Bevelled edge global white color tiles of size 595x595 mm and 0.4-0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient ) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece. |
| 43 | Providing and Fixing M/F suspended ceiling (Single Layer) which includes providing & fixing GI perimeter channels of size 0.55mm thk having one flange of 20mm and another flange of 30mm and a web of 27mm along with perimeter of ceiling, screw fixed to brickwall/partition with the help of nylon sleeves and screws, at 610mm centres. Then suspending GI intermediate channels of size 45mm, 0.9mm thk with two flanges of 15mm each from the soffit at 1220mm centres with ceiling angle of width 25mmx10mmx0.55mm fixed to soffit with GI cleat and steel expansion fastners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 457 mm centres. 8mm tapered edge Calcium Silicate Board is then screw fixed to ceiling section with 25mm drywall screws at 230mm centres. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, Joint paper tape and 2 coats of Drywall topcoat Suitable for Calcium Silicate board, complete in all respects. |
| 44 | 12mm cement plaster 1:4 (1cement: 4 fine sand) |
| 45 | 6mm cement plaster to ceiling 1:3 (1 cement : 3 fine sand) |
| 46 | Extra for providing and mixing water proofing material proportion recommended by the manufacturers. b) 12mm cement plaster 1:4 (1 cement : 4 sand) |
| 47 | Applying priming coat with ready mixed primer of approved brand and manufacture on wood work complete. |
| 48 | Applying priming coat with ready mixed primer of approved brand and manufacture on steel work. |
| 49 | Painting two or more coats (excluding priming coat ) with superior quality ready mixed paint for steel work of approved brand and manufacture in all shades on new work to give a even shade |
| 50 | Painting(two or more coats) with synthetic enamel paint of approved brand and manufacture in all shades on new work over and under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 51 | Wall painting (two or more coats) with plastic emulsion paint of approved brand and manufacture on new work to give an even shade (including min two priming coats and two layers of putty alternatively) |
| 52 | Varnishing (two or more coats) with copal varnish of approved brand and manufacture on new work including an under coat Bees waxing on wood work with local made wax polish in proportion of 2:1 5:1 0.5 (2 wax: 1.5 linseed oil - With transparent wood filler. |
| 53 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture (such as weather shield, Apex) including applying one coat of cement primer and one coat of surface treatment etc. complete. |
| 54 | Painting one or more coats of acryllic exterior paint of approved brand and manufacture (such as Dulex/ Asian Paints/ Sherwin Willians) on old work including cleaning the surface with water etc. complete. |
| 55 | Applying breathable, non-reactive, antifungal, and water repellant Silane/ Siloxane chemical as approved by Archaeological Survey of India/ Engineer, of approved brand and manufacture, diluted with solvent mineral Turpentine oil in the ratio of 1:12 (One part of approved chemical :12 Part of Turpentine oil), on the exposed laterite masonry surface with two or more coats to give uniform application of chemical on the surface, all complete as per direction of Engineer. (The rate is inclusive of all materials & labours). |
| 56 | Melamine polishing on wood work (one or more coat) - Matt |
| 57 | Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete.- a) 100 mm dia RCC pipe |
| 58 | Providing and laying non-pressure NP2 class (light duty) RCC pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand ) including testing of joints, etc. complete.- a) 250 mm dia RCC pipe |
| 59 | Supplying of granitic or basaltic stone soling of size 15-20 cm and Murrum having P.I. Value not more than 6 and laying including packing with smaller stones and consolidation with power roller including spreading waters and consolidation of binding material etc. complete.(Measurements shall be considered on finished item.and and layer of WBM of 50/75mm thick shall be taken seperately over this sub-base to obtain smooth surface, as per the directives of Engineerin-charge). |
| 60 | Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3-wheeled steel/ vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening/binding materials to fill up the interstices of coarse aggregates, watering & compacting to the required density, making necessary earthern bund to protect edges, lighting, guarding, barricading, and maintainance of diversion etc complete as per MoRT & H specification no 404. - By mechanical means - Grade II |
| 61 | Providing and applying tack coat with bitumen grade of 80/100 or bitumen emulsion using pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom as per MoRT&H specifications clause 503., - Bitumen 80/100 @0.375 Kg/m2. |
| 62 | Providing and laying 50mm (consolidated thickness) full grout using granitic or basaltic stone of specified grading at 6.00 cu.m. per 100 sq.m. grouting with hot bitumen straight run bitumen(or with such bituminous material of grade and type as specified by the Engineer-in-Charge)at 5.0kg. per sq. m. binding with key aggregate of granitic or basaltic stone of specified grading at 1.5 cu.m. per 100 sq.m. including Providing and laying seal coat sealing the voids in a bituminious surface laid with F.E loader with 1 Cu.m. bucket capacity to the specified levels, grade and cross fall using Type A seal coat with 0.98 kg/sqm of bitumen of grade as per MoRT&H specifications clause 513. |
| 63 | Providing & fixing bevelled edge mirror of superior glass (5mm thk) of approved Quality, shape & size complete with CP brass screws and washers, Cleats, CP studs etc Complete |
| 64 | Providing & fixing C.P. Brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. Brass Screws - 600x20mm size |
| 65 | Providing and fixing toilet paper holder - C.P. brass |
| 66 | Providing & fixing soap dish chromium plated with brackets fixed to wooden cleats with CP brass screw |
| 67 | Supplying and fixing at the site of work of Steel Fibre Reinforced Concrete (SFRC) manhole covers with frames made as per IS :12592 (part I and II) - 1991 in concrete M45grade. The covers and lapped in 2mm thick. steel plate and this plate & lifting hooks are duly painted in corrosion resistant epoxy paint etc. complete. Light Duty (2.50 Metric Tonne Capacity) a) 450x600 mm |
| 68 | Providing and fixing ASTM UPVC pipe, conforming to ASTM 2467 with ISO 14001, including all UPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step UPVC solvent cement and testing of joints complete as per direction of Engineer. Internal work - Exposed on wall. SCH-40 (blue)/(white) - 25mm outer dia. |
| 69 | Providing & fixing in position traction matting antiskid clear tape 2 inch wide (50mm) for staircase having Granite Treads. The antiskid clear tape should be mineral coated slip resistant material with pressure sensitive adhesive including cleaning, degreasing, priming to mask the surface (if required), presssing using rubber roller etc. complete |
| 70 | Providing and fixing in position terracotta jallis as per specified size, pattern and colour, all complete. The jalli size of 200-220x200-220x60-63mm with size accuracy of +/-5% and should be suitable for exterior use with less than 6% water absorption capacity. The jalli should be fire resistant, with anti skid and scratch resistant properties. There should be uniformness in colour texture and colour should not fade after exposure to sunlight. The jallis are to be fixed like bricks stacked on each other with adhesives and stiffeners are to be embedded in the jalli to provide strength. The installation process should be as specified by the manufacturer with special tile adhesive approved by the Engineer incharge. Preparation of the surface should be as per manufacturers instructions and specifications. The surface of the jalli has to be cleaned of any residual adhesive soon after installations to give it a clean and neat look. MS plate 40mmx5mm has to be placed at every third layer and welded to MS Hollow section which has to be provided on sides, as per attached drawing. (MS will be paid separately) complete. |
| 71 | Providing and fixing in position terracotta brick tiles wall cladding as per specified size, pattern and colour, all complete. The tiles size of 240x60/75x9/10mm with size variation of +/-2mm/ thickness variation +/-1mm and should be suitable for exterior use with less than 8% water absorption capacity. The tiles should be fire resistant A1, with anti skid and scratch resistant properties (MOH Harderness 5). There should be uniformness in colour texture and colour should not fade after eposure to sunlight. The tiles are to be fixed with 4 to 6mm spacers as specified by the manufacturer. Jointing with cement based high polymer modified quick-set tile adhesive (water based) conforming to IS:15477, using 5 kg. adhesive per sq.m of tile area, in average 3 mm thickness, including pointing in white cement mixed with pigment of matching shade complete. Preparation of the surface should be as per manufacturers instructions and specifications. The surface of the tiles has to be cleaned of any residual adhesive soon after installations to give it a clean and neat look. |
| 72 | Providing & Fixing Signage made of 6mm thick transperent/ coloured acrylic sheet base material. The graphic should be computer cut self adhesive vinyl covered with clear vinyl to protect from peeling. The signage should be fixed with 12mm dia S.S. studs or S. S. Mirror screws. |
| 73 | Providing and fixing signages made from aluminium composite panel 4mm thk. base material with computer cut self adhesive vinyl graphic covered with clear vinyl to protect from peeling. The signage shall be fixed with 12mm dia S.S. studs or S.S. mirror screws. |
| 74 | Providing & Fixing in position Autoglow photoluminescent Signage made of 1.5mm thick Rigid sheet as base material. The colour, text, size graphic symbol should be as specified by the Fire and Safety Department and IS code 12349(1988) (Reaffirmed 2002) . The signages should be approved by the engineer in charge. The signage should be fixed with 12mm dia S.S. studs or S. S. Mirror screws.. |
| 75 | Supplying, Installing, Testing & Commissioning (SITC) of Electric Traction Passenger Lift with• Rated capacity :- 8 Passenger/544Kg• Floors :- G+3 floor (4Stops/4 Landings)• Travel :- 10.50 mtrs• Location of Lift Machine:- Machine Room Less (MRL) • Rated speed :- 1.0mps Variable speed (VS) • Car/Landing door clear opening of 800 mm wide x 2000 mm high• Clear Car size of 1100 mm wide x 1300 mm deep x 2250mm high• Lift shaft available having clear size of 1850 mm wide x1750 mm deep, 1500 mm Pit depth, 4100mm Overhead.• Doors type :- Centre Opening Power Operated (COPO)/ Telescopic Opening Power Operated (TOPO) Doors with frame made from SS 304 grade solid (non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). • Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge.• Car Operating Panel (COP) with SS face plate having metallic push buttons with Braille Code & luminous indicator around button with Floor Position Indicator (FPI), scrolling UP/DN LED indicator & with/without attendant key switch, Overload warning Device (OWD) with audio-visual alarm, Voice annunciation system (VAS) in Konkani/Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor |
| 76 | • Landing Operating Panel (LOP) with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille Code & luminous indicator around button with Car Position Indicator (CPI), Lift car arrival & next travel direction audio-visual indication at all landings. • Lift controller based on microprocessor/ Programmable Logic Control (PLC) with Variable Voltage Variable Frequency (VVVF) Drive having closed loop control system, with Intelligent Building Management System (IBMS) compatible having necessary port. The controller shall have necessary protections such as over current, over voltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters. The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. • Automatic Rescue Device (ARD) complete with necessary Sealed maintenance free (SMF) Valve-Regulated Lead-Acid (VRLA) batteries.• Fireman controller having fireman switch at fire Landing,• Closed Circuit Television (CCTV) surveillance system comprises of 2 nos minimum 2.0MP FHD IP (Internet Protocol) based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with Network Video Recorder (NVR) kept in LMR/Fire Command Centre (FCC) with High Definition Recording (HDR) data backup for 90 days with 18\\" Full High Definition (FHD) TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. |
| 77 | • Lift Machine of Gearless Permanent Magnet Synchronous AC Machine (PMSM) of suitable kW with duty cycle of minimum 120 starts per hour (with submission of necessary test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, Over speed safety governor (OSG), electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on Lift machine room (LMR) floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. • Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. • Minor civil work such as alteration work if any necessary for erection of landing door frames and its accessories eg. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing & fixing steel girders/RCC work having adequete strength for mounting & Hosting lift machine etc. complete as per specification no. LFT.Including For Lift having 800mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade landing door at all floors [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories, door operator mechanism with drive, required aluminium sill, infrared curtain & necessary wiring with interlocking arrangement etc. necessary for the normal safe functioning of lift installation complete. • Full Collective Control System 1) General: - Job includes entire procedure of obtaining all necessary erection permissions & \\"License to Work the Lift\\" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. |
| 78 | Supply and erecting of 9 inch (225 mm sweep) exhaust fan, 1400 rpm, complete with all accessories. a) Cat A |
| 79 | Supplying and erecting Energy Saving BLDC Ceiling fan 230 V A.C. 50 cycles 1200 mm, max. energy consumption of 28W having service ratio (CMM/W) of Min. 8 , PF>0.9, THD<10% with IR remote control Temperature Rise of Max. 40 deg. C, having external mounted control PCB completely erected in position as per specification no. FG-FN/CF |
| 80 | Supplying and erecting LED square / circular Max. 14 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 1500 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 81 | Supplying and erecting anodized aluminium mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<20%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 82 | Supplying and erecting LED Panel Light (600mm X 600mm) Max. 35 W having CRCA powder coated housing, polystyrene diffuser having system lumens output of Min 4200 Lumens, min. efficacy of 120 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50 including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with minimum 2 years warranty as per specification No. FG-IDF/LED. |
| 83 | Earthing with GI earth pipe 2 mts long 40 mm dia medium class with ISI mark, of approved brands including accessories and providing masonry enclosure with CI/RCC cover having locking /Lifting arrangement and watering pipe etc. (but without charcoal or coke and salt) as required as per the Earthing Drawing provided by the Engineer-Incharge.The scope of work includes the following: a) Excavation of pit of size not less than 1.0x1.0x 2.0 mtrs(min) and disposal of excavated soil. b) Class B GI pipe, 40mm diameter as per specifications. c) Charcoal/salt as per specs ( paid seperately). d) Refilling the pit of size not less than 1.0x1.0x 2.0 mtrs(min) with soft black soil of minimum resistivity i/c transportation. e)Masonary chamber with proper foundation, cover plate and locking arrangement. f) Testing of earth value with earth megger and certifications of its value. Aluminium tag with embossed earthing value to be attached to the pipe. g)watering arrangement(plumbing will be paid seperately). a) In soily Strata |
| 84 | Extra for using salt and charcoal for GI or copper plate earth electrode as required( 96 Kgs of Charcoal and 5 Kgs of Salt) |
| 85 | Supplying and laying 25 mm x 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required |
| 86 | Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for connections etc. as required |
| 87 | Supplying and fixing 1 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of Cat 6 type, compliant ANSI/TIA-568.2-D standards in position as per specification no. WG-ELVC/PC |
| 88 | Supplying, fixing, and configuring 24 ports, PoE switch compliant with IEEE 802.3 standards with min. 193W PoE capacity with 4GE SFP uplink in provided rack as per specification no. WG-NWC/ENS |
| 89 | Supplying, installing, testing & commissioning of 32/40 Ch. Network Video Recorder (NVR), suitable connect Min. 32 IP Cameras, up to 5 Megapixel Resolution, with HDMI/VGA outputs, provided HDMI output of 4K resolution or VGA output with output up to 1920 × 1080.Support H.265 or higher, H.264, MJPEG,Incoming Bandwidth 250Mbps with minimum 4 SATA Hard Disks, ANR Technology, 4 SATA interfaces for 4 HDDs and capacity of each HDD up to 8TB,minimum 02 USB port, Alarm I/O 16/4, RJ-45 10/100/ 1000 Mbps selfadaptive Ethernet interface, ONVIF conformance, Multiple network monitoring: Web viewer.support protocol TCP/IP, DHCP, DNS, DDNS, NTP, SADP, SMTP, NFS, iSCSI, UPnP™, HTTPS.RoHS, UL, CE, FCC certified.duly erected in provided U Rack with wiring connections, tagging and programming etc. complete as per specification no. CCTV-NVR |
| 90 | Supplying & erecting of High definition 4/5 Megapixel IP IR Dome Camera with following featuresImage Sensor : minimum 1/2.8\\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant, minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE, IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. |
| 91 | Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation.Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection, Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled.Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalent BIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM. |
| 92 | Supplying & erecting of High definition 4/5 Megapixel IP IR Bullet Camera with following featuresImage Sensor : minimum 1/2.8\\" Progressive Scan CMOS,Video Resolution : minimum 2592 x 1520Video Compression : H.264, H.265 or higher, at least Three individually configurable stream,Frame rate : minimum 25 fps at all resolutions,WDR : minimum 120 dB Wide Dynamic Range,ONVIF profile conformant,minimum IR distance : 50m,Lens Type : 2.8/4/6 mm Lens, fixed focal,Field of View : 2.8 mm, horizontal FOV 107°, vertical FOV 57°, diagonal FOV 129°4 mm, horizontal FOV 86°, vertical FOV 47°, diagonal FOV 102°6 mm, horizontal FOV 55°, vertical FOV 29°, diagonal FOV 65°Lux sensitivity - minimum 0.2 Lux at color, minimum 0.05 Lux at Black & White,0.0 Lux (IR) Night Vision Distance minimum IR - 50m.Camera minimum Adjustment Angles - Pan : 350°, Tilt : 72°, Rotate : 350°.Power Supply : Support 12VDC & PoE,IP67, IK10 - Vandal Resistant.Built in micro SD/SDHC/SDXC card slot of minimum 128 GB, Built in microphone.minimum Input/Output - Audio in × 1, Audio Out × 1, Alarm in × 1, Alarm Out × 1. Image Settings : Rotate mode, saturation, brightness, contrast, sharpness, gain, white balance. |
| 93 | Image Enhancements : Day/Night-Auto (ICR)/Color/Black & White, 3D Digital Noise Reduction, Automatic White Balance, Automatic Gain Control, Backlight Compensation, Highlight Compensation. Events : Privacy Masking, Motion detection, Scene change detection, Face capture, Video tampering, audio exception detection, Region entrance detection,Region exiting detection.Operating temperature ( -30 to 60° C ) .Security - User account and password protection, HTTPS, IP filter, IEEE 802.1X, digest authentication, user access log, TLS1.2, AES - 256, SSH/Telnet closed, FTP disabled.Protocol - DHCP, UDP, HTTP, HTTPS, NTP, DNS, RTP, RTSP, SMTP, SSL/TLS, TCP/IP, Secure Real-Time Transport Protocol (SRTP), Bonjour, SNMP and Secure shell (SSH) supported protocol.RoHS, WEEE, ISO-14001 and REACH compliant, UL/EN OR equivalentBIS/TECH/STQC or any indian standards as applicable, CE, FCC certified.duly erected in position on wall/ceiling/false ceiling/provided pole (mounting height not more than 5 meter) etc with all accessories etc complete as per specification no. CCTV-CAM |
| 94 | Supplying & erecting 43\\" professional LED display with 1920*1080 (Full HD) Display, suitable for 16/32 channel NVR and following featuresBrightness: minimum 500 Cd/m2Contrast Ratio: minimum 1000:1Viewing angle: 178/178 deg.Response time: maximum 8 msInputs: HDMI, VGA, BNC,USB, Audio In,Built-in speakers maximum 10 W, Suitable to operate on 100-240 V 50 Hz AC supply and 24/7 Duty Cycle duly erected on wall or table top with standard accessories like wall mount stand and wiring connections etc. complete as per specifications no. CCTV-MON |
| 95 | Supplying & erecting 8 TB internal Surveillance HDD suitable for SATA Port of NVR, interface transfer rate 6 GB/S, maximum sustained transfer rate 210 MB/Sec to 213 MB/S. Drive bay supported 08+, Cameras supported up to 64, Cache (MB) 256, Load/Unload Cycle -3000000, Work Load Rating per Year 180TB, MTBF 1000000 Hrs. HTTPS. RoHS, UL, CE certified, duly erected in position in provided NVR as per specification no. CCTV-HDD |
| 96 | Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x550x347 mm) as per specification No. WG-NAS/RAK |
| 97 | Supplying, installing, testing & commissioning digital (hybrid) type EPABX of 6 x 16 universal extensions compliant to IEC 61000, EN 60950, CISPR 22, IS:9000 part 2/section 4 having LAN/WAN Port, USB port, RS232 port as per specification complete as per specification no. WG-TA |
| 98 | Supplying, installing, testing & commissioning push button telephone instrument desk top unit as per specification complete |
| 99 | Providing & erecting 5 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL. |
| 100 | Supplying and erecting Street light bracket made from 25 mm. dia ‘B’ class G.I. Pipe, 0.6 m in length along with pole cap of 300mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC |
| 101 | Supplying and erecting integrated LED street light fitting 26 to 30W IP65 & IK08 class having single piece pressure die-cast aluminium housing , having system lumens output of Min. 2600 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs at L70B50 including driver complete with minimum 2 Years warranty as per specification No. FGODF/SL. |
| 102 | Supply, Fabrication, Erection, Testing & Commissioning of Main Panel floor mounted with frame of suitable M.S. channel dully painted, fabricated of 14/16 swg CRCA sheets completely derusted, chemically treated and powder coated with shade suggested by client and having following items as per single line diagram:- 315/400A, 36KA, Adjustable TP MCCB - 1 no. wiring for ammeter having Three & half digit LED display, external C.T. operated, calibrated for suitable to operate on 500V, 0 to1000A AC supply, L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio with 15VA, 3 LED pilot lamps with colour glasses with miniature lamps 230 V/250V from GED connected to 400A, 4P alluminium busbar with outgoing of 11 nos 10 - 40A KWH meter with 25A, TP, MCB & 2 nos 50 - 100A KWH meter with 63A, TP, MCB. , 1 meter of 63A is wired to 1 no of 40A, TP MCB and 3 nos of 63A, TP, MCB. 2nd meter of 63A connected to 100A, 4P busbar which feed 1no 25A, TP, MCB & also connect to 100A, 4P ATS having DG Supply which consist of 100A, 25KA, TP MCCB - 1 no. wiring for ammeter having Three & half digit LED display, external C.T. operated, calibrated for suitable to operate on 500V, 0 to1000A AC supply, L.T. Current Transformer with bar primary 50/5 to 1000/5 ratio with 15VA, 3 LED pilot lamps with colour glasses with miniature lamps 230 V/250V & outgoing of 3 nos 63A, TP, MCB, 1 no 25A, DP, RCBO and 1 no 63A, 4P, RCBO as per single line drawing of MLTP |
| 103 | Supplying, erecting, testing & commissioning of 3 kVA capacity on line pure sine wave, PWM, IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS (Without batteries) |
| 104 | Supplying and erecting 12 V/42Ah SMF battery with battery terminal wire, duly charged complete with 24 months warranty complete |
| 105 | Supplying, erecting, testing and commissioning of diesel generating set with alternator of 30 kVA output continuous rating, 3 phase, 415 V, 50 Hz, 0.8 p.f., A.C. supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2/G3 and maximum fuel consumption 5.9 ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads, with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 65 ltr etc., on provided M20 grade CC foundation as per specification no. GEN-DG |
| 106 | Supplying & erecting Minimum three & above star rated Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 1.5 kW/2 HP with discharge 600/140 Litres per Minute (LPM) for head of 8/22 m & 50 mm suction/ 50 mm delivery pipe on provided C.C. foundation as per specification No. WP-CGP |
| 107 | Supplying & erecting automatic control panel for 1 Ph, 230 volt, A.C. Submersible/centrifugal pump set up to 3 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. |
| 108 | S u p p l y i n g & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wallcomplete. |
| 109 | Supplying and erecting ABC powder type fire extinguisher as per IS : 13849/ 15683 of 1 kg capacity with necessary clamp for erection on wall |
| 110 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC. |
| 111 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/SAC. |
| 112 | Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/ SAC. |
| 113 | Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V + 1% rated for 3 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top complete with overload & short circuit protection. |
| 114 | Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V + 1% rated for 4 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top complete with overload & short circuit protection. |
| 115 | Supplying and erecting fully automatic line Voltage stabilizer buck and boost type for operation on input voltage 160 to 270 V and output voltage 230 V + 1% rated for 5 kVA maximum load and with voltmeter, selector switch, 6A/16A flush type 3 pin socket for output and with 3 core flexible cord and 3 pin 6/16 A plug top complete with overload & short circuit protection. |
| 116 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete as per specification no. AP/AC-CP. |
| 117 | Supplying & erecting seamless outside & inside, smooth, dry and clean copper pipe with ROHS compliant suitable for refrigerant having 22SWG thickness and inner dia/size 12mm complete as per specification no. AP/AC-CP. |
| 118 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 12 mm for solar water heater/AC system. |
| 119 | Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 16 mm for solar water heater/AC System. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 7 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender