Railways Government Departments Closing in 15 days TDR #56516662

Supply Of 1) ACETABULAR ROOF REINFORECEMENT TITANIUM RING,CAGE OR TRIFLANGE CUP OF SIZES 50MM, 54MM, 58MM, 62MM, 66MM 2) CANNULATED SPINAL PEDICLE SCREWS FOR SPINE SURGERY FOR MINIMALLY INVASIVE SURGERIES SYSTEM, 3) NTERBODY FUSION CAGE: IMPLANT & 4)

Issued by Government Departments · , Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Aug 2026
15 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of 1) acetabular roof reinforecement titanium ring,cage or triflange cup of sizes 50mm, 54mm, 58mm, 62mm, 66mm 2) cannulated spinal pedicle screws for spine surgery for minimally invasive surgeries system, 3) nterbody fusion cage: implant & 4) plif cage 11 x 11 x 11 mm , srphc82425111-cannulated spinal pedicle screws for spine surgery for minimal ly invasive surgeries system -1) this system should have a cannulated poly-axial screw wit h an angulation of plus or minus 60 degree. 2) system should have cannulated dual start threaded screw have self-tapping flutes allowing for easy and quick screw insertion. 3) s ystem should have square thread locking cap eliminate cross threading. 4) system should have dual step locking cap which should lock the poly-axial screw while provisional tight ening which aids in parallel compression and distraction. 5) system should have straight and pre lordosed 5.5mm diameter rod. 6) system should have cannulated poly-axial screw available in 5.5, 6.5 and 7.2 mm diameter and all possible length. the implant should be supp lied as set. each set consists of 4 pedicle screws with 4 locking cap and 2 pre contoured r od. the implant should be supplied with all instruments needed for minimally invasive spin e surgery. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82425168-interbody fusion cage: implant- 1. should be made of titanium. 2. should have nano-lock surface technology. 3. should have honeycomb structure design f or allowing more bony surface contact and reduce cage subsidence. 4. should have open graft window for ensuring direct contact of graft and endplate. 5. should have lateral window for better visualization. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82425384-plif cage 11 x 11 x 11 mm [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82425058-acetabular roof reinforecement titanium ring,cage or triflang e cup of sizes 50mm,54mm,58mm,62mm,66mm with additional hook and four threaded 6.5mm c ancellous screws of appropriate length and poly liner. to be supplied with complete set o f instrumentations. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

BOQ

Sl. No.Item Description
1SRPHC82425111-CANNULATED SPINAL PEDICLE SCREWS FOR SPINE SURGERY FOR MINIMAL LY INVASIVE SURGERIES SYSTEM -1) THIS SYSTEM SHOULD HAVE A CANNULATED POLY-AXIAL SCREW WIT H AN ANGULATION OF PLUS OR MINUS 60 DEGREE. 2) SYSTEM SHOULD HAVE CANNULATED DUAL START THREADED SCREW HAVE SELF-TAPPING FLUTES ALLOWING FOR EASY AND QUICK SCREW INSERTION. 3) S YSTEM SHOULD HAVE SQUARE THREAD LOCKING CAP ELIMINATE CROSS THREADING. 4) SYSTEM SHOULD HAVE DUAL STEP LOCKING CAP WHICH SHOULD LOCK THE POLY-AXIAL SCREW WHILE PROVISIONAL TIGHT ENING WHICH AIDS IN PARALLEL COMPRESSION AND DISTRACTION. 5) SYSTEM SHOULD HAVE STRAIGHT AND PRE LORDOSED 5.5MM DIAMETER ROD. 6) SYSTEM SHOULD HAVE CANNULATED POLY-AXIAL SCREW AVAILABLE IN 5.5, 6.5 AND 7.2 MM DIAMETER AND ALL POSSIBLE LENGTH. THE IMPLANT SHOULD BE SUPP LIED AS SET. EACH SET CONSISTS OF 4 PEDICLE SCREWS WITH 4 LOCKING CAP AND 2 PRE CONTOURED R OD. THE IMPLANT SHOULD BE SUPPLIED WITH ALL INSTRUMENTS NEEDED FOR MINIMALLY INVASIVE SPIN E SURGERY. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]
2SRPHC82425168-INTERBODY FUSION CAGE: IMPLANT- 1. SHOULD BE MADE OF TITANIUM. 2. SHOULD HAVE NANO-LOCK SURFACE TECHNOLOGY. 3. SHOULD HAVE HONEYCOMB STRUCTURE DESIGN F OR ALLOWING MORE BONY SURFACE CONTACT AND REDUCE CAGE SUBSIDENCE. 4. SHOULD HAVE OPEN GRAFT WINDOW FOR ENSURING DIRECT CONTACT OF GRAFT AND ENDPLATE. 5. SHOULD HAVE LATERAL WINDOW FOR BETTER VISUALIZATION. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]
3SRPHC82425384-PLIF CAGE 11 X 11 X 11 MM [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]
4SRPHC82425058-ACETABULAR ROOF REINFORECEMENT TITANIUM RING,CAGE OR TRIFLANG E CUP OF SIZES 50MM,54MM,58MM,62MM,66MM WITH ADDITIONAL HOOK AND FOUR THREADED 6.5MM C ANCELLOUS SCREWS OF APPROPRIATE LENGTH AND POLY LINER. TO BE SUPPLIED WITH COMPLETE SET O F INSTRUMENTATIONS. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]

AI Tender Summary

OUR REF NO 56516662
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 07-08-2026
Authority
Authority Name Southern Railway
Work Description Supply Of 1) acetabular roof reinforecement titanium ring,cage or triflange cup of sizes 50mm, 54mm, 58mm, 62mm, 66mm 2) cannulated spinal pedicle screws for spine surgery for minimally invasive surgeries system, 3) nterbody fusion cage: implant & 4) plif cage 11 x 11 x 11 mm , srphc82425111-cannulated spinal pedicle screws for spine surgery for minimal ly invasive surgeries system -1) this system should have a cannulated poly-axial screw wit h an angulation of plus or minus 60 degree. 2) system should have cannulated dual start threaded screw have self-tapping flutes allowing for easy and quick screw insertion. 3) s ystem should have square thread locking cap eliminate cross threading. 4) system should have dual step locking cap which should lock the poly-axial screw while provisional tight ening which aids in parallel compression and distraction. 5) system should have straight and pre lordosed 5.5mm diameter rod. 6) system should have cannulated poly-axial screw available in 5.5, 6.5 and 7.2 mm diameter and all possible length. the implant should be supp lied as set. each set consists of 4 pedicle screws with 4 locking cap and 2 pre contoured r od. the implant should be supplied with all instruments needed for minimally invasive spin e surgery. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82425168-interbody fusion cage: implant- 1. should be made of titanium. 2. should have nano-lock surface technology. 3. should have honeycomb structure design f or allowing more bony surface contact and reduce cage subsidence. 4. should have open graft window for ensuring direct contact of graft and endplate. 5. should have lateral window for better visualization. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82425384-plif cage 11 x 11 x 11 mm [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82425058-acetabular roof reinforecement titanium ring,cage or triflang e cup of sizes 50mm,54mm,58mm,62mm,66mm with additional hook and four threaded 6.5mm c ancellous screws of appropriate length and poly liner. to be supplied with complete set o f instrumentations. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Basic Detail
Tender No 02265740
Bidding Type Tender
Location
City
State Tamil Nadu
Key Dates
Publish Date 13 Jul 2026
Submission Date 07 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
e7537b8a-37d8-4afc-9d8e-716f854e0b14.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 13, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 07, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days

Tender Documents

Download All (ZIP) ↓
pdf

e7537b8a-37d8-4afc-9d8e-716f854e0b14.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders