Tender For Estimate For Laying Upvc Up Gradation Pipe Line For Outlet Rd 62660/L Of Fatehnangal Disty.
Tender Overview
Project Description
Tender for Estimate For Laying Upvc Up Gradation Pipe Line For Outlet Rd 62660/L Of Fatehnangal Disty.
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Jul-2026 | date extends corrigendum03 | Date | 24-Jul-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | PUNJAB WATER RESOURCES DEPARTMENT Madhopur Division UBDC Gurdaspur NAME OF WORK: Estimate for Laying UPVC U/G Pipe line for outlet RD 62660/L of Fatehnangal Disty. Name of Firm Sr.No Description Unit QUANTITY Rate (in figures) Rate (in Words) |
| 2 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including dressing levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation , including the cost diversionfor traffic, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 3 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation andsubsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 4 | First class brick masonary 229 mm thick laid in cement sand mortar 1.6 in foundation and plinth |
| 5 | 10mm thick cement plaster 1.4 on sides walls |
| 6 | 10mm thick cement plaster 1:4 on bed and top. |
| 7 | Reinforced cement concrete 1:2:4 hand mixed but including steel reinforcement |
| 8 | Cement Conc.1:2:4 including supply, carriage & with stone ballast or shingle |
| 9 | Cement concrete 1:4:8 with brick ballast 40mm gauge |
| 10 | Laying and jointing of UPVC pipe280 mm dia of 2.5 kg/ sq cm pressure ISI Marked UPVC Pipes as per ISI- 4985 along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointingand testing complete as per specifications. |
| 11 | providing, laying, fixing, testing andcommissioning of ‘C‘ Class heavy duty MSPipe conforming to Indian Standard IS :1239/3589 including fittingsliketees, bends ,sockets,elbows,flanges, tapers, nuts bolts,gaskets etc. fixing the pipe on the wall /ceiling with suitable clamps and painting withtwo or more coats of synthetic enamel paint of required shade complete in all respects.(d) 50 mm dia |
| 12 | Wrought Iron and mild steel ladders, framed grills, grating etc. complete fixed in position in D-tank |
| 13 | Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS:1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm |
| 14 | Providing and fixing of Alfa Alfa Valve 280 fitted on riser pipe to act as Nakka (D regulators) |
| 15 | Centreing and shuttering for Concerte faces |
| 16 | Providing & Fixing of Steel Shutter Gate Assembly in Main Pipeline complete in all respect |
| 17 | Providing and fixing 280 mm Elbow/bends of 90 degree 6kg/cm2 pressure as per IS 4985 i/c testing commisioning and complete in all respect to the specification of engineer in charge |
| 18 | Providing and fixing 280 mm Elbow/bends of 45 degree 6kg/cm2 pressure as per IS 4985 i/c testing commisioning and complete in all respect to the specification of engineer in charge |
| 19 | Providing and fixing 280 mm equal Tee of 6kg/cm2 pressure as per IS 4985 i/c testing commisioning andcomplete in all respect to thespecification of engineer incharge |
| 20 | Providing and fixing MS service saddle 280 x 50mm as per IS 4985 i/c testing commisioning and complete in all respect to the specificationof engineer in charge |
| 21 | Providing and fixing Tail end piece 280 mm of 6 kg/cm2 pressure as per IS 4985 i/c testing commisioning complete in all respect to thesatisfaction of engineer in charge |
| 22 | Providing & fixing Single air valve ISI Marked as per IS-14845 including jointing all carriages complete .C.I Single air valve (Size 50mm) |
| 23 | Any Other Compatibility Report for Harpur.xls Run on 28-03-2025 12:10 The following features in this workbook are not supported by earlier versions of Excel. These features may be lost or degraded when you save this workbook in an earlier file format. Minor loss of fidelity # of occurrences Some formulas in this workbook are linked to other workbooks that are closed. When these formulas are recalculated in earlier versions of Excel without opening the linked workbooks, characters beyond the 255-character limit cannot be returned. 2.0 'boq 1'!B21 'boq 1'!C22 |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
TodayCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 1 dayBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 1 dayBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender