Tender For Special Repair To Bldg No P-377 (Rect Living) Of 58 Gtc Under Ge Shillong
Tender Overview
Project Description
Tender For Special Repair To Bldg No P-377 (Rect Living) Of 58 Gtc Under Ge Shillong
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 06-Aug-2026 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area exc 1.50 sqm but not exc 4 sqm each & removing from site complete all as specified and directed. |
| 2 | Taking down chowkhats or frame with shutter (without taking off shutter from the frame) area not exc 1.50 sqm each & removing from site complete all as specified and directed. |
| 3 | S&F MS flat iron as in small articles such as hold fast and similar work complete all as specified and directed. |
| 4 | M&L for PCC, 1:2:4 Mix, type B1 (Using 20mm graded crushed stone Aggregate) for fixing hold fast complete all as specified and directed. |
| 5 | Supply and fixing 2nd class HW plain solid straight chowkhats/frame wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed. |
| 6 | Supply and fixing 2nd class HW 35mm thick plain framed panelled shutters (any number of panels), with panel of timber flats on both sides or of veneered particle board medium density, wood particle board with commercial face veneers; supplied and fitted to chowkats complete all as specified and directed. |
| 7 | Supply and fixing 2nd class HW 35mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. divided into squares (without sash bars ), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified andd irected. |
| 8 | S & F Anodised aluminium frame Powder Coating (minimum thickness of powder coating 50 micron) for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed. |
| 9 | S&F Anodised aluminium window and ventilator shutters Powder Coating (minimum thickness of powder coating 50 micron), side hung/ Sliding type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1no.) complete all as specified and directed. |
| 10 | S&F Sheet glass 4.80 mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and directed. |
| 11 | S&F Sheet glass 4.80 mm thick, ordinary quality and glazing with oil putty in square exc 0.5 Sqm in each pane including fixed with wooden beads/glazing pins or spring clips in wooden or metal frames complete all as specified and as directed. |
| 12 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 13 | S&F framed work such as grills, gratings, etc. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165all as specified and directed |
| 14 | S&F 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed |
| 15 | M&L for preparation of new steel surface exc 10cm width or girth and applying of two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed . |
| 16 | M&L for preparation of new wooden surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 17 | Supply and fixing 100mm size butt hinges, medium weight, cold rolled mild steel, ISI marked complete all as specified and directed. |
| 18 | Supply and fixing 200mm size Aluminium anodised, barrel tower bolts of extruded section and fixed ISI marked complete all as specified and directed. |
| 19 | Supply and fixing 150mm size Aluminium handles, cast type, anodised complete all as specified and directed. |
| 20 | Supply and fixing 250mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed,ISI marked, complete all as specified and directed. |
| 21 | Supply and fixing 150mm size Aluminium anodised, barrel tower bolts of extruded section and fixed ISI marked complete all as specified and directed. |
| 22 | S & F 140mm long Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed. |
| 23 | S & F in repairs Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 24 | S & F Galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. |
| 25 | M&L for Forming jambs, etc. to openings CM 1:6 (to foregoing item), including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work, complete all as specified and directed. |
| 26 | Demolition of stone slabs and granite laid, bedded and pointed in any mortar of any description or thickness in floors, aprons cills or plateform etc all as specified and directed. |
| 27 | M & for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. |
| 28 | M&L for rounding to edges of stone slabs one edge, such as in steps cooking plateform, and other similar situation complete all as specified and directed. |
| 29 | M&L for water proofing treatment to RCC roof slab/sunken floor, including parapet comprising with the following courses of treatment/specification from bottom to top:-(i) Taking out old roof treatment and roughening the same old concrete slab by picking, sweeping clean and washing down with water to remove dust etc. and applying cement slurry @3kg/Sqm(ii) Screed bed or bedding layer of mortar 1:4 in 15 mm thick for laying as in roof slab with mixing of WPC and surface finished fare and smooth without using extra cement. (Note: WPC shall be measured and paid for under separate items)(iii) Cleaning of plastered roof surface and applying one coat of cold bituminous primer @ 0.25ltr /Sqm conforming to IS:3384-1986.(iv) APP based polymeric membrane 3mm thick (minimum), weighing 3.5 Kg/sqm reinforced with polyester non woven fabric (weighing not less than 160 gms/Sqm) shall be less applied over bituminous primer as specified above over a Application of polymeric membrance shall by torch application. The overlaps shall be minimum 100mm on the transverse direction and 75mm on longitudinal direction.(v) Applying one coat of aluminum paint over the APP modified membrance @ 0.11Kg/sqm. |
| 30 | Taking up or down GI tubing 15mm dia and connection including removing to store complete all as specified and directed. |
| 31 | Supplying and laying of 20mm CPVC pipes with SDR 13.5 pipes & plain CPVC SDR 11 fittings fittings on walls/ceiling or laying in floors complete all as specified and directed. |
| 32 | S&F of Brass Elbow of 20mm of CPVC pipe complete all as specified and directed. |
| 33 | S&F of Brass TEE of 20mm of CPVC pipe complete all as specified and directed. |
| 34 | Taking up or down GI tubing 20mm dia and connection including removing to store complete all as specified and directed. |
| 35 | Supply and fix 20 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete and connecting to water supply pipe line including concealing in wall and making good disturbed surfaces as per existing complete all as specified and directed. |
| 36 | Refixing of 20mm tubes any grade, fixed to walls and ceilings or laying in floors with all new fittings complete all as specified and directed. |
| 37 | Taking up or down GI tubing 25mm dia and connection including removing to store complete all as specified and directed. |
| 38 | Supply and fix 25 mm bore galvanised steel water tubing, medium grade including necessary fittings such as GI bends, tee, union etc fixed on wall / floor complete all as specified and directed. |
| 39 | S&F in repair 15mm bore stop cock cast copper alloy, fancy type, chromium plated, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for union and fixed complete all as specified and directed. . |
| 40 | S & F in repair 15 mm bore CP fancy type bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 41 | S & F in repair 15 mm bore CP fancy type 2 in 1 bib tap long body cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 42 | S&F in repair of 15 mm bore Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 43 | S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified and directed. |
| 44 | S&F in repair brass chromium plated tubular towel rail 600mm long between the flanges and 20mm dia complete all as specified and directed. |
| 45 | S&F in repair bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers, complete all as specified and directed. |
| 46 | S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 47 | S&F as in repairs.Vitreous China wash down water down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) including Plastic water closet seat, black, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified and directed. |
| 48 | S & F in repair Vitreous china squatting pan of pattern Orissa Pattern of size 580x 440 mm white with PVC ‘P’ or ‘S’ trap , front or back inlet but excluding flushing cistern and flush pipe including placing in position in floor and embedded in cushion of PCC type E2 ( 1:5:10, using 40 mm graded stone aggregates), and finishing the top surfaces to match with the existing flooring as in repairs (bore 110 mm) complete all as specified and directed. |
| 49 | S & F in repair PVC (Plastic polymer Cistern) valve less, Syphonic action type, flushing cistern of capacity 10 litres, low level, white with inlet, ball valve, manually operated with one PVC ball valve horizontal plunger type including provision of 32mm PVC flush pipe of required length and making connections complete all as specified and directed. |
| 50 | S&F in repairs Vitreous China bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating,and Union for discharge pipe. with grating and union for discharge pipe all as specified and directed. |
| 51 | S&F spreader for Urinal with all necessary fittings complete all as specified and directed. |
| 52 | S & F in repairs to 600mm long PVC flexible Waste pipe to WHB/urinals/Sink complete all as specified and directed. |
| 53 | S&F in repair for PVC connections 15mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 54 | S&F in repair PVC (SWR) pipes 110 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 55 | S&F in repair PVC (SWR) pipes 75 mm dia single socketed in any length with rubber ring joints fixed to walls/ floor complete including clamps for securing pipe complete all as specified and directed. |
| 56 | S&F in repair PVC (SWR) vent cowl 110mm dia complete all as specified and directed. |
| 57 | S&F in repairs PVC (SWR) bend with access door of 110mm bore complete all as specified and directed. |
| 58 | S&F in repairs PVC (SWR) bend with access door of 75mm bore complete all as specified and directed. |
| 59 | S&F in repair PVC (SWR) 110mm dia in junction single, (Single T) equal or unequal complete all as specified and directed. |
| 60 | S&F in repair PVC (SWR) 75mm dia in junction single, (Single T) equal or unequal complete all as specified and directed. |
| 61 | S & F in repair 75mm dia of outlet PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. |
| 62 | S&F in repair 20 mm dia Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 63 | S & F 1000 litres capacity double layer, rotational molded, polythene (white colour), tripple layer water storage tank, ISI Marked (Cylindrical vertical with closed top),colour white , hoisted and fixed on roof in position, including all fitting such as connection pieces with GI tank nipple for inlet, outlet, washout and overflow etc and including dismantling existing water tank complete all as specified and directed. |
| 64 | S&F in repair for 20mm dia Ball cock valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 2 0 m m - 2 1 0 g m s ) complete all as specified and directed. |
| 65 | M&L for Pre cast RCC 1:2:4 type B1 using 20 mm graded stone aggregates as in cover slab for soakage well / manhole and similar works supported on walls set in cement mortar 1:6 complete all as specified and directed.Note:- Reinforcement steel shall be measured & paid separately. |
| 66 | M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including bending, and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 67 | Demolition of cement Concrete (RCC chimney/cover slabs) of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 68 | S&F 2nd class HW boarding 20mm thick fixed with nails as in eaves board planed one side with butt joint including dismantling boarding of any description complete all as specified and directed. |
| 69 | Taking down cement plaster in cement or cement lime mortar on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc, Including removal of debries out side MD land complete all specified and directed. |
| 70 | M&L for rendering 10 mm thick on concrete surface in cement mortar (1:6) as backing coat and 5 mm thick in CM 1:4 as finishing coat finishing the surface even and smooth without using extra cement, including mixing of water proofing compound as per manufacturer's instructions complete all as specified and directed. Note:- WPC shall be measured & Paid separately |
| 71 | M&L for 10mm thick plaster in cm (1:6) on fair faces of brick or concrete surfaces including finishing even & smooth without using extra cement complete all as specified and directed. |
| 72 | M & L for rendering 05 mm thick in CM 1:3 on ceiling surfaces of cement concrete and finished the surface even and smooth without using extra cement complete all as specified & directed . |
| 73 | Supply only water proofing compound (Powder) all as specified and directed. |
| 74 | M & L for preparation of new plastered/concrete surfaces of walls and applying two coats of Oil Bound Distemper of approved shade/tint over and including one coat of compatiable priming paint including applying 1.5 mm thick wall care putty complete all as specified and directed. |
| 75 | M & L for preparation of new plastered/concrete surfaces of ceiling, applying three coat of white wash complete all as specified and directed. |
| 76 | Material & Labour for preparation of new surface applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and also min. 1.5 mm thick exterior wall care putty on wall over new surfaces.,complete all as specified and directed. |
| 77 | Complete removal existing treatment and applying two coats of Oil Bound Distemper of approved shade/tint over and including one coat of compatiable priming paint including applying 1.5 mm thick wall care putty complete all as specified and directed. |
| 78 | M & L for preparation of old decorated surfaces (plastered or unplastered) of ceiling and applying two coats of white wash complete all as specified and directed. |
| 79 | Material & Labour for preparation of old surface applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm and also min. 1.5 mm thick exterior wall care putty on wall over old surfaces.,complete all as specified and directed. |
| 80 | M&L Precast PCC (1:3:6) type C1 (using 20mm graded agg) solid block masonry exc 10cm in width or girth and setting CM (1:6) including demolition of Precast cement concrete block walling in any position and Including removal of debries out side MoD land complete all as specified and directed. |
| 81 | Demolition of plain cement concrete (unreinforced) in ground floors and pavings not exc 15 CM thick below or above ground level complete all as specified and directed. |
| 82 | M&L for 75 mm thick PCC 1:3:6 Mix, type C2 (using 40mm graded crushed stone agg) as in plinth protection/path incl finishing even & smooth with using extra cement in, complete all as specified and directed. |
| 83 | M&L for 1:5:10 PCC (using 40mm graded agg) as in sunken floor incl finishing even & smooth with using extra cement including demolition of existing PCC, complete all as specified and directed. |
| 84 | M&L for PCC 1:3:6 type C2 (using 20mm graded aggregate) as in surface channels and drain or foundation mass concrete or path complete all as specified and directed. |
| 85 | Extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed. |
| 86 | S&F in repairs Chromium plated shower rose with or without swivel joints, any size, including fixing to steel pipe or union CP over head shower of size 125mm of approved make with CP shower arm for wall mounted showers flange complete all as specified and directed. |
| 87 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 88 | M&L Non-skid ceramic colour tiles 7 to 8 mm thick , (square/rectangular), area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in cement sand mortar 1:4 complete all as specified and directed. |
| 89 | M&L Glazed ceramic colour tiles of size 350 x 250 x 7mm thick in vertical wall etc set and jointed with neat cement slurry and pointed in white or colour cement to match with the colour of tile over and including 10 mm thick backing course in cement sand mortar 1:4 complete as specified and directed. |
| 90 | M& L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing and 20 mm thick screed bed in CM 1:3 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 91 | M& L for Kota stone slab 20-25 mm thick in riser of steps, skirting, dado and pillar laid over cement screed and jointed with 10 mm thick baking course in CM 1:4 including roughening surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust etc complete all as specified and directed. |
| 92 | S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 93 | S & F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of an colour having tensile strenngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of plain/corrugated steel sheeting any gauge, thickness in roof covering complete all as specified and directed. |
| 94 | S&F PVC gutter , Half Round, 180mm size complete all as specified and directed. |
| 95 | S&F in repairs Joint Bracket (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 96 | S&F in repairs Support Bracket, 180mm for PVC pipes (half round) complete all as specified and directed. |
| 97 | S&F in repairs Running Outlet (with 2 clamps), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 98 | S&F in repairs Stop End Outlet (with 1 clamp), 180mm for PVC pipes (half round) complete all as specified and directed. |
| 99 | S&F in repairs PVC Reducer, 180mmx110mm complete all as specified and directed. |
| 100 | Dismantiling of boarding any description fixed any position with frame work if fixed with screws complete all as specified and directed. |
| 101 | ML for anodised aluminium snap frame work for false ceiling complrising GI perimeter channel 0.55mm thick with main T-flange of 20mm and web of 30mm fixed to surrounding wall flange using nylon sleeves and ss screws and web 20mm each , crossed T with flange 20 mm and web 20 mm fixed to main T. main T is suspended from soffit at approx 1200 mm center to centre with GI wire of 6mm dia , cleat and steel expansion fasteners, GI frame shall be 600mmX600mm and laid/inserted 4mm thick nonasbestos fibre cement building board to aluminuim frame as in ceiling complete all as specified and directed. |
| 102 | S&F in repair stainless steel decorative pattern holder/end brackets suitable for drapery rod of 25 mm dia complete all as specified and directed. |
| 103 | S&F in repair stainless steel decorative pattern end support suitable for drapery rod of 25 mm dia complete all as specified and directed. |
| 104 | S&F in repair 25 mm dia stainless steel drapery rod not less than 1mm thick cut to size and fixed in position, including Standard screw complete all as specified and directed. |
| 105 | S&F 18/19 mm thick block boards grade 1 quality exterior grade commercial type, fixed with screws to timber frame/MS frame complete all as specified and directed. |
| 106 | S&F 0.90 mm thick decorative laminates type 1 of surface finish color and pattern as approved fixed with approved adhesive as per manufactures instruction complete all as specified and directed. |
| 107 | Taking down carefully aluminium/copper conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets LED battens etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified and directed. |
| 108 | Material and labour concealed point wiring for one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLSH cables in and including suitable size PVC conduit and fittings of medium grade, including pressed steel / PVC terminal switch boxes fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectional area multistranded copper conductor FRLSH PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. |
| 109 | All as per item No.108 above but One 3 pin 5 Amps socket out let points on independent board complete all as specified and directed. |
| 110 | All as per item No. 108 above but 5 Amp socket on same board with other switches complete all as specified and directed. |
| 111 | Material and labour point wiring for power point controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FR cables in and including 20 mm width or higher size PVCconduit and fittings of medium grade, including including pressed steel / PVC terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor FR PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. |
| 112 | Supply and fixing submain wiring for DBs/ Power Point, two single core ,4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. |
| 113 | Supply and fixing submain wiring for DBs/ Power Point, two single core ,6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade drawing in and Including suitable size PVC conduit (ISI marked) including 6 sqmm nominal cross sectional area multistranded copper conductor FR cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and directed. |
| 114 | Supply and fix socket outlets 2 in 1, 3 pin, 5/6 Amps flush type230/240 V complete all as specified and as directed. (For Same Board only) |
| 115 | Supply and fix Switch socket Combination 16A, 6 pin, 3 module 230 V complete all as specified and directed. |
| 116 | Supply and fix switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified and directed. |
| 117 | Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and directed. |
| 118 | Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and directed. |
| 119 | Supply and fix in repair Bldg security light fittings 35 watts, minimumm system lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and directed. |
| 120 | Supply and fix 18 W LED light fitting wall mounted batten 4'ft , extruded aluminium housing, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 20 watt,6000K including necessary connection complete all as specified and directed. |
| 121 | Re fixing serviceable LED batten obtained from Item No.107 here in before complete all as specified and directed. |
| 122 | Supply and fixing in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 123 | Supply and fix Vertical distribution board double door MCB TPN 4 way with IP 43 multiphase outgoing suitable for mounting 63 Amps MCB as incomer with Bus bars, Neutral links complete with all accessories complete all as specified and directed. |
| 124 | Supply and fix epoxy powder coated sheet metal enclosure for DBs, double door, Single pole and neutral 240 V, 12 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and directed. |
| 125 | Supply and fix MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. |
| 126 | Supply and fix MCB SPN 40 - 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. |
| 127 | Supply and fix MCB TPN 40 - 100 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection complete all as specified and directed. |
| 128 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 129 | Supply and fix exhaust fan, steel body AC single Phase. 230V of size 250mm sweep with, blades, and frame and louvers complete all as specified and directed. |
| 130 | Supply and fix Water heater storage type, vertical type wall mounted, electrically operated 230 V, 50 Hz of capacity 50 litres, heating element of 2 KW, Incoly 800 glass coated heating element, 4 year warranty, Inner tank finish and coating with feroglass dry powder technology, 2 units of PVC connection hot and cold water hose, BEE 5 star rated and 05 Year complete product Warranty complete all as specified and directed. |
| 131 | Supply and fix in repair table lamp wall mounted with lamp 7watt with all accessories including necessary connection complete all as specified and directed. |
| 132 | Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 25x4mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 4 daysBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 4 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender