Tender For Providing Of Otm Accn For Civil Admin Section At Af Stn Mohanbari
Tender Value
43.50 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
6 days left
EMD
87000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Dibrugarh → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Providing Of Otm Accn For Civil Admin Section At Af Stn Mohanbari
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 23-Jul-2026 | Revised BOQ | BOQ | 05-Aug-2026 |
BOQ
| Sl. No. | Item Description |
| 1 | Surface excavtion in soft/ loose soil n.exc 30 cm in depth and averaging 15 cm deep and getting out complete all as specified and directed. |
| 2 | Excavtion in trenches, n.exc 1.5 mtr wide and n.exc 1.5 mtr in depth for foundations, etc or for shafts,wells, cesspits, manhole, pier holes, etc n.exc 10 sqm on plan and n.exc 1.5 mtr in depth in soft/ loose soil and getting out complete all as specified and directed. |
| 3 | Excavating in post holes (or similar holes) each n.exc 0.5 Cum getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in soft/loose soil complete all as specified and directed. |
| 4 | Excavating in trenches, n.exc 1.5 m wide and exc 1.5 mtr depth beyond the first 1.5 mtr depth for foundation etc complete all as specified and directed. |
| 5 | Returning ,filling in ,including spreading ,levelling ,watering and well ramming in layers not exceeding 25 cm in depth complete all as specified and directed. |
| 6 | Removal of excavted soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and directed. |
| 7 | M&L for plain cement concrete 1:4:8 type D2 using 40 mm graded aggregate crushed stone aggregate as in foundations/mass concrete complete all as specified and directed. |
| 8 | M&L for RCC M25 (nominal mix ) as in foundations ,footing,plinth beams complete all as specified and directed. |
| 9 | M&L for RCC M25 (nominal mix ) as in columns and roof beam complete all as specified and directed. |
| 10 | Use and waste of formwork to sides of concrete foundations, footings, sides and soffits of foundations (if any) of foundation and plinth beams and similar work ,verticalor to batter for rough finished surfaces complete all as specified and directed. |
| 11 | Use and waste of formwork to sides and soffits of floors or roof beams, beam haunching, girders, bressummers, lintels, cantilevers, shelves including supports. Overhangs, etc splays between floors and beams for flat fair finished surfaces complete all as specified and directed. |
| 12 | Use and waste of formwork to sides of pillars, posts,struts, piers, columns and stanchionsfor fair finished surfaces complete all as specified and directed. |
| 13 | M&L for TMT steel bars ,as in reinforcement, 10 mm dia and over, cut to length, bent to shape required, including cranking, hooking ends and blinding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed. |
| 14 | All as item No 13 above herein before but 8 mm dia and over upto and including 10 mm dia as in stirrups ,spacers and blinders etc complete all as specified and directed. |
| 15 | M&L for Fe410-W(Gde-250)quality B roof truss (framed), trussed, prulins, crane gantries, rails, and fasteining and heavy bracket framing (beams, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed. |
| 16 | M&L for girder or single stanchion, built up of one beam or channel section with flange plates, caps, bases, splices, angle brackets, cleats and other connections complete all as specified and directed. |
| 17 | M&L for mild steel bolts of 20 mm dia purpose made with hexagonal or square head one end and serewed other end or screwed both ends, each serewed end to end fitted with washers and one hexagonal or squarre nut, exc 30 cm long complete all as specified and directed. |
| 18 | S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of camouflage pattern having tensile strength of 550 mpa as in roof covering/ ridge/ cladding to wall, fixed with self tapping screw (heavy duty) with in built washers and neoprene and EDPM washers, in roofs, walls etc complete all as specified and directed. |
| 19 | S&F for pre painted galvalume aluminium zinc coating GI based corrugated steel sheet .50 mm thick of camouflage pattern having tensile strength of 550 mpa as in ridges, hips, valley gutter, drip or straight fastening etc fixed with self tapping screw etc complete all as specified and directed. |
| 20 | M&L for brick work with sub class 'B' bricks(old size), straight or curved on plan exceeds 6m mean radius,built in cement motor 1:4 complete all as specified and directed. |
| 21 | M&L for rendering 15mm thick in cement motor 1:4 on other than fair faces of brick work or concrete sur faces even and smooth without using extra cement complete all as specified and directed. |
| 22 | M&L for Rendering 10mm thick in cement motor 1:6 on fair faces of brick work or concrete sur faces even and smooth without using extra cement complete all as specified and directed. |
| 23 | Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface for plinth protection/ under floor complete all as specified and directed. |
| 24 | M&L for 75 mm thk plain cement concrete Type C-2, 1:3:6 (using 40 mm graded aggregate)in plinth protection complete all as specified and directed. |
| 25 | M&L for 100 mm thk plain cement concrete TypeD-2 1:4:8 (using 40 mm graded aggregate) as in paving/ under floor complete all as specified and directed. |
| 26 | M&L for Preparation of new steel Surfaces of any description, over 10cm in width or girth,of any description and applying two coats of synthentic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 27 | S&F for vitreous china urinal, half stall type, white complete urinal bowl type or half stall pattern basin only including connection to flushing pipe and outgoing pipe fixed in repairs complete all as specified and directed. |
| 28 | S&F for Health faucet (abs body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtre long flexible tube and ABS wall hook including making connection and fixed in position complete all as specified and directed. |
| 29 | Providing and fixing false ceiling of Non asbestos fiber cement board /designer tile prepainted (high pressure steam cured ) of 4mm thick (as per IS: 14862:2000 type B catagory -3) of size 595x595mm and any one of the design (cascade or electra) in true horizontal level. Suspended on and including inter locking metal grid of hot dipped galvanized steel section (galvanized @120gms both side inclusive and black painted groove on all T webs) consisting of main T runner with suitably spaced joints to get required length and 24x38 mm made of 0.3mm thick sheet spaced at 1200mm c/c and cross T of size 24x38 mm made of 0.3mm sheet 1200mm long spaecd between main T at 600mm c/c to form a grid of 1200x600mm and secondary cross T of length 600mm and size 24x38mm made of 0.3mm thick sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and wall angle of size 24x24x0.40mm and laying false ceiling tiles in the grid including required cutting/making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc.Main T runners to be suspended from trusses/ceilings using suitable suspension arrangement as per manufacturers instructions/literature. GI adjustable wire of 4mm dia with galvanized butterfly level clips spaced at 1200mm c/c along main T bottom exposed width of 15mm of all T section of 4mm dia GI wire shall be pre-painted with with polyster paint and black painted groove at centre of size 4mm depth and 4.5mm width, all complete at all heights as per direction of Engr-in-charge. Note : The exposed/ visible surface of metal surface frame work shal be powder coated of mim 40 micron |
| 30 | S&F for Solid PVC Door Frame of size 50x47mm made out of 5.0mm Plain Colour PVC Sheet reinforced with Mild Steel Square Tube and fixing in Opening complete all as specified and directed. |
| 31 | M&L for Factory Made Solid Panel PVC Door Shutter 30mm thick (Style) Plain Colour (Ivory shade) consisting of Frame made out of Mild Steel Tubes for Top and Bottom Rails, Mild Steel Frame shall be covered with heat moulded wood grain PVC ‘C’ Channel having a PVC Sheet Strip of 20mm width stuck inside with Solvent Cement for Stiles and Wood Grain PVC Sheets for Top Rail, Lock Rail & Bottom Rail on either Side and as gap insert for Top Rail & Bottom Rail, Panelling of Wood grain PVC Sheet to be fitted in the Mild Steel Frame welded/sealed to the Stiles and Rails with suitable 5mm thick x 15mm wide PVC Sheet Beading used inside Stiles and Rails and decorative PVC Beading of 10mm x 10mm (90°) and jointed together with Solvent Cement and fixing in the Frame and hanging/ fixing with and including Stainless Steel Hinges, complete all as specified and directed.Note : Butt Hinges will be Measured and Paid Separately. |
| 32 | M&L for Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminium Ventilator Frame having Frame of Section 100x44mm of thickness 1.6mm Shutters of Section 32x15mm (with and including Half Portion fixed Glazed Shutter and Rest Half Portion Louvered with Glazed Shutter) including Stainless Steel Wire Mesh, Rubber Gasket for Securing the Glass 5.5mm thick Figured Glass, Aluminium Grill and necessary Aluminium Mongery and Handles including necessary Locking Arrangement complete all as specified and directed. |
| 33 | M&L for Powder Coated (Minimum thickness of Powder Coating 50 Micron) Aluminum Sliding Windows 2-Tracks with 2 Sliding Shutters with Extrusions Aluminum of following Sections including Jointing Cleats, Glazing Clips, Rubber Packaging, Snap Beading and other necessary Aluminium Builders Hardware as required, complete all as specified and as directed :- A. FRAME :-(i) Top and Side Member for 2 Track Frame of Size 61.85x31.75x1.5mm (Weighing 0.784 KG/RM), Model No. 20829 of Make : Jindal or equivalent.(ii) Bottom Rail of Frame for Sliding of Size 61.85x31.75x1.5mm (Weighing 0.909 KG/RM), Model No. 20830 of Make : Jindal or equivalent.B. SHUTTER :-(i) Top and Bottom Rail of Sliding Shutter of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20736 of Make : Jindal or equivalent.(ii) Side of Sliding Shutter with Handle and Self Locking Arrangement, Section of Size 40x18x1.5mm (Weighing 0.547 KG/RM), Model No. 20738 of Make : Jindal or equivalent.(C) Sliding Shutter to be provided with 5.0mm thick Sheet Glass.(D) Aluminum Diamond Grill 6.5mm thick with Mat Finished fixing on Wall/ Wooden Chowkat/ Aluminium Frame with suitable Size of Aluminum 'U' Channel and Steel Chromium Plated, Screw with Rawel Plug with following Details :- (i) Aperture Size of Aluminum Grill 67x84mm. (ii) Cord Dimension 7.0x5.8mm. (iii) Plate thickness 3.0mm.(E) Stainless Steel Wire Cloth, 0.36mm Nominal Dia of Wire and Average Width of aperture 1.40mm and fixed with Stainless Steel Wire Staples/ Clip/ Aluminium Flat |
| 34 | M& L for powder coated aluminium door frame with shutter of section 100 mm x 45 mm thickness of sheet 16 gauge , partially glazed and panelled lock rail/ bottom rail of shutter 100 mm x 45 mm top rail 80 mm x 45 mm including necessary jointing cleats glazing clips, rubber packing anodized aluminium including necessary fittings and aluminium mongeries i.e. 150 mm long two Nos aluminium handles 02 nos ,200 mm long aluminium tower bolt hinges with each leaf , rubber gasket for securing the glass and 3 nos 100mm long butt hinges with each leaf including 5.5 mm thick tinted glass PVC panelling including mortice lock grills in glazed portion etc complete all as specified and directed. |
| 35 | S&F for Aluminium anodised Barrel Tower Bolt, 150mm long, Extruded Section complete all as specified and directed. |
| 36 | S&F for Aluminium Alloy anodized sliding door bolt 250mm long with Hasp Staple (Bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section and fixed complete all as specified and directed. |
| 37 | S&F for 75mm size (as approved) stainless steel Butt Hinge and fixing to PVC door shutter complete all as specified and directed. |
| 38 | S&F for 150mm long Aluminium Handle, Cast type, anodised, Extruded and fixed complete all as specified and directed. |
| 39 | S&F for Mild Steel Curtain Rod/ Harrison Rail 20mm Dia, Chromium Plated with Brackets, Stops, Rollers, fixed on Walls and Fixed-in-repairs complete all as specified and directed. |
| 40 | M&L for Joint Free Non-Skid Ceramic Coloured Tiles 7.0mm to 8.0mm thick (Rectangular or Square), Area of Each Tile exc. 0.06 Sqm but not exc. 0.11 Sqm (1st quality) in Floors, Set and Jointed in Neat Cement Slurry and Pointed in Coloured Cement to match the Tile, laid over and including Screed or Screed Bed 15mm thick in cement mortar 1:6 complete all as specified and directed. |
| 41 | M&L for glazed ceramic coloured/ printed tiles 450x300x7.0mm thick in vertical surfaces i.e. dado, skirting, etc, set in neat cement slurry and pointed in coloured cement to match the tile, fixing over and including screed or screed bed 10mm thick in cement mortar 1:4 complete all as specified and directed. |
| 42 | M&L for green marble work 18mm to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match the shade of marble including grinding and polishing, fixing over and including 20mm thick cement screed bed in cement mortar 1:6 complete all as specified and directed. |
| 43 | M&L fo preparing new plastered surfaces on walls, applying 1.5mm thick wall care putty including cutting/ rubbing down to obtain an even and smooth surface, applying two coats of distemper oil emulsion (as approved) over a coat of alkali resistant priming paint complete all as specified and directed. |
| 44 | M&L for preparing newly plastered surfaces of walls and applying two coats of acrylic based weather coat exterior grade emulsion paint (any tinted) in camouflage primer (as specified by manufacturer of paint) including cleaning drops from joinery, glasses, electrical fittings and washing floors, etc complete all as specified and directed. |
| 45 | S&F for CPVC Pipe 32mm outer dia, SDR 11 & plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed. |
| 46 | S&F for Brass elbow suitable for CPVC pipe 32mm outer dia, SDR 11 complete all as specified and directed. |
| 47 | S&F for Brass tee suitable for CPVC pipe 20mm outer dia, SDR 11 complete all as specified and directed. |
| 48 | S&F for Male Brass threaded adaptor (MTA/ MBTA) suitable for CPVC pipe 32mm outer dia, SDR 11 complete all as specified and directed. |
| 49 | S&F for Female Brass threaded adaptor (FTA/ FBTA) suitable for CPVC pipe 32mm outer dia, SDR 11 complete all as specified and directed. |
| 50 | S&F for Union suitable for CPVC pipe 32mm outer dia, SDR 11 complete all as specified and directed. |
| 51 | S&F for Bib Tap 15mm bore (dia) cast copper alloy, chromium plated, fancy type with crutch or butter-fly handle, screwed down, screwed for Iron pipe or for brass ferrule and fixed-in-repairs complete all as specified and directed. |
| 52 | S&F for Pillar Tap 15mm bore (dia), cast copper alloy chromium plated, fancy type, with capstan heads, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed-in-repairs complete all as specified and directed. |
| 53 | S&F for Stop Valve 15mm bore (dia), cast copper alloy, chromium plated, fancy type with long shank and cup (Concealed type), screwed down, high pressure, with crutch or butter-fly handle, screwed both ends for iron pipe or for unions and fixed-in-repairs complete all as specified and directed. |
| 54 | S&F for 20mm bore (dia) gun metal globe/ gate valve with iron wheel head, screwed both ends for iron pipe and fixed-in-repairs complete all as specified and directed. |
| 55 | S&F for PTMT ball valve 20mm bore (dia), having weight not less than 210 Grams, high pressure with epoxy coated aluminium rod and high density plastic ball, screwed for iron pipe complete all as specified and directed. |
| 56 | S&F for Vitreous China wash down water closet pan (pedestal pattern), white including connections to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe incl seat cover etc complete all as specified and directed. |
| 57 | S&F for PVC flushing cistern 10 Litre capacity white, low level, valveless, syphonic action type, ISI marked with inlet, ball valve, float and handle, a pair of cast iron brackets erecting stand duly painted, including PVC flush pipe 32mm or 40mm bore (dia) of low or high density with PVC long bend, cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 and fixed-in-repairs complete all as specified and directed. |
| 58 | S&F for Vitreous China White Wash Hand Basin 550x400mm, flat back or angle back type with brass chromium plated waste fitting 32mm bore (dia) and PVC waste pipe 32mm or 40mm bore (dia) of low or high density, a pair of cast iron brackets or erecting stand duly painted, cutting and pinning in ends, making good disturbed surfaces in cement mortar 1:3 but excluding taps, chain, plug & porcelain stopper and fixed-in-repairs complete all as specified and directed. |
| 59 | S&F for PVC connection pipe 15mm in size and 450mm in length with PTMT nuts and fixed-in-repairs complete all as specified and directed. |
| 60 | S&F for looking mirror size 600x450mm, 5.5mm thick selected quality glass, bevelled edge, mounted on 4.0mm thick PVC Sheet with PVC/ PTMT frame, fixed to wooden plug with brass chromium plated screws and fixed-in-repairs complete all as specified and directed. |
| 61 | S&F for tubular towel rail 20mm dia, brass chromium plated, D-type, 600mm long between flanges with bracket (one pair) and fixed-in-repairs complete all as specified and directed. |
| 62 | S&F for 75mm bore (dia) PVC (SWR) Floor Trap with chromium plated grating, plain including jointing to waste pipe with solvent cement and fixed-in-repairs complete all as specified and directed. |
| 63 | S&F for 100mm dia (Minimum weight 25 Grams) PTMT grating doom complete all as specified and directed. |
| 64 | S&F for 110mm bore (dia) PVC (SWR) pipe, single socketed, in any length with rubber ring joints, fixing to walls or laid on floors with clamps complete all as specified and directed. |
| 65 | S&F in repar 75mm bore (dia) PVC (SWR) Bends (any radius) and jointing with solvent cement complete all as specified and directed. |
| 66 | S&F for 75mm bore (dia) PVC (SWR) junction, single (single T), equal or unequal with access door and jointing with solvent cement complete all as specified and directed.as directed. |
| 67 | S&F for 75mm bore (dia) PVC (SWR) pipe, single socketed, in any length with rubber ring joints, fixing to walls or laid on floors with clamps complete all as specified and directed. |
| 68 | S&F for 110mm bore (dia) PVC (SWR) bends (any radius) and jointing with solvent cement complete all as specified and directed. |
| 69 | S&F for 110mm bore (dia) PVC (SWR) junction, single (Single T), equal or unequal with access door and jointing with solvent cement complete all as specified and directed. |
| 70 | S&F for 500 Litres rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part 1 complete all as specified and directed. |
| 71 | M&L for cement concrete 1:2:4 (20 mm graded stone aggregates) in lintels upto 1.50 Mtr clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, parapets and railings upto 600 mm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering. Slightly rounded or chamfered angles and throating, finishing all exposed faces of concrete including use and waste of formworkas required / ordered complete all as specified and directed. |
| 72 | M&L for Sand filling and/ or Sand Cushioning average 50mm thick under floor or interlocking paver blocks, etc including watering (if required) and consolidation complete all as specified and directed. |
| 73 | M&L for Machine pressed Pre-cast concrete interlocking paver block 60 mm thk of M-35 Grade, with grey cement and pigment of any shape and size (as ordered), conforming IS-15658-2006 complete all as specified and directed. |
| 74 | M&L for Screed bed or bedding layer of mortar 15mm thick for laying floor finishes in cement mortar 1:6 complete all as specified and directed. |
| 75 | M&L for virified ceramic coloured tiles tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not excwwding 0.38 Sqm, in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed. |
| 76 | Supply only integral water proofing compound complete all as specified and directed. |
| 77 | S&F for CPVC Pipe 25mm outer dia, SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed. |
| 78 | S&F for Brass Elbow suitable for CPVC pipe 25mm outer dia, SDR 11 complete all as specified and directed. |
| 79 | S&F for Brass Tee suitable for CPVC Pipe 25mm outer dia, SDR 11 complete all as specified and directed. |
| 80 | S&F for Male Brass threaded adaptor (MTA/ MBTA) suitable for CPVC pipe 25mm outer dia, SDR 11 complete all as specified and directed. |
| 81 | S&F for Female Brass threaded adaptor (FTA/ FBTA) suitable for CPVC pipe 16mm outer dia, SDR 11 complete all as specified and directed. |
| 82 | S&F for Union suitable for CPVC pipe 25mm outer dia, SDR 11 complete all as specified and directed. |
| 83 | S&F for SGSW gully trap square mouthed 100mm size set in PCC (1:3:6) type C1 block measuring 450mm and 100mm thick bed concrete and jointing to drain pipe in cement mortar (1:1) including 100x150mm high PCC kerb in (1:2:4) type B1 with CI perforated grating 150 x 150mm bituminous coated including Demolition of existing SGSW gully trap including PCC kerb etc and disposal of waste/ sludge complete all as specified and directed. |
| 84 | S&F for 150mm bore dia PVC (SWR) pipe, Minimum 6kg/Cm sq including all fittings, laid in trenches complete all as specified and directed. |
| 85 | M&L for precast reinforced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slab of manholes, septic tank etc, set in cement mortar (1:4) including necessary form, moulds etc and including taking out/removal of existing unserviceable cover slab from manholes /septic tank complete all as specified and directed.Note :- Reinforcement shall be measured and paid separately. |
| 86 | S&F for any dia bore PVC (SWR) vent cowl complete all as specified and directed. |
| 87 | M&L for treating the bottom and sides of excavation at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 88 | M&L for treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface (Area of the sub structure in contact with backfill to be measured) complete all as specified and directed. |
| 89 | M&L for treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed. |
| 90 | M&L for treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed. |
| 91 | M&L for treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed. |
| 92 | M&L for consealed conduit point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with all accessories (including cutting chases & making good the disturbed surface to its original specification) including modular metal flush box, including size 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor cable as earth continuity conductor connected to main switches/DB's or common earth dolly complete all as specified and directed for the following :- |
| 93 | Description all as per item No 92 here in before but for one Ceiling Fan / exhaust fan point controlled by one, one way switch and regulator complete all as specified and directed. |
| 94 | Description all as per item No 92 here in before but for one 3 point 5 Amps switch socket outlet point controlled by one switch on the same board complete all as specified and directed. |
| 95 | Description all as per item No 92 here in before but for one 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board complete all as specified and directed. |
| 96 | Description all as per item No 92 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point incl running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified and directed. |
| 97 | S&F for ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and directed. |
| 98 | S&F for modular swith 6/10 Amp one module complete all as specified and directed. |
| 99 | S&F for modular swith 16 Amp one module complete all as specified and directed. |
| 100 | S&F for modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and directed. |
| 101 | S&F for modular socket 6/16 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and directed. |
| 102 | S&F for modular fan regulator 120W 230 volts AC 50 Hz 2 modules complete all as specified and directed. |
| 103 | S&F for white cover plate with frame 3 module complete all as specified and directed. |
| 104 | S&F for white cover plate with frame 6 module complete all as specified and directed. |
| 105 | S&F for white cover plate with frame 8 module complete all as specified and directed. |
| 106 | S&F for LED lights fitting 1 X 20 W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Crompton, Cat part No : TCS-109-20-65-SL-DP-NWH equivalent Havells cat Part No : LUMILINETRENDBS20WLED865SPCWH. |
| 107 | S&F for recess mounted slim compact aluminium die-cast, edge lit panel, round fixture with opal diffuser and separate electronic driver 15 watt, 230 Volt, 50 Hz including lamp, connection wire, suitable modification in existing false ceiling board and connecting up with 3 core flexible copper conductor cable of suitable size and length complete all as specified and directed. Make : Crompton, Cat part No : CDR-205-15-57-SL-NWH equivalent Havells cat Part No : INTEGRANXTDLR15WLED857S. |
| 108 | S&F for Lamp holder with 7 watt LED bulb PVC / polycarbonate type with back plate straight or angular, 230 volts suitable for batten fitting complete all as specified and directed. Make : Havells Cat Part No LHLDDDBNIY2T007 equivalent Crompton Cat Part No : LED7WNDFWB2SCDL. |
| 109 | S&F for LED building security light fitting 25 Watt, 230 Volt AC,with suitable bracket and clamp, nut bolts, outdoor type with high pressure die cast aluminum housing and heat resistant with driver, lamp, surge protection device, and corrosion resistant including thermal management in multipole optics, having IP 65/66 protection and connecting up with 3 core flexible copper conductor cable of suitable size and length complete all as specified and directed. Make : Crompton, Cat part No : ERP-427-25-57-HL2LM-NBK equivalent Havells cat Part No : ENDURASUNDOWNSL25WLED765PASYBOPC. |
| 110 | S&F for copper wound ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V,1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Energy efficient, five star rated, with brushless direct current motor (BLDC) complete with mounting arrangment as per site requirement and connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed. |
| 111 | S&F for copper wound exhaust fan, steel body AC single Phase. 230V of size 300m sweep, 900/950 RPM, heavy duty, steel metallic body type with, blades, and frame and louvers complete with mounting arrangment as per site requirement and connecting wire up to nearest ceiling rose in flexible PVC pipe complete all as specified and directed. |
| 112 | M&L for sub main wiring with 2 run of 2.5 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 2.5 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit complete all as specified and directed.Note : (i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length). |
| 113 | M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts grade with stranded copper conductor including one run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unsv sub main, complete all as specified and as directed.Note :(i) PVC non rigid nonmetallic conduit shall be measured & paid separately under relevant item of this Schedule ‘A’.(ii)Two run of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length). |
| 114 | S&F for sheet metal enclosure MCB DB TPN double door type AC 415 V 4 way with 200 Amps rated bus bar, vertical/horizantal type complete all as specified and directed. |
| 115 | S&F for MCB, Single pole & neutral,5 to 32 amps, 240 volts, ‘C’ curve, 10KA complete all as specified and directed. |
| 116 | S&F for MCB, Single pole, 5 to 32 amps, 240 volts, ‘C’ curve, 10 KA complete all as specified and directed. |
| 117 | S&F for Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\\"S/lsolators complete with complete all as specified and directed. |
| 118 | S&F for sheet metal enclosures with socket two pin and earth plug top and MCB SP-20 Amp 230 volt complete all as specified and directed. |
| 119 | M&L for earthing complete with galvanised steel earth plate 600mm x 600mm x6.3mm thick electrode and 4mm galvanised iron wire as earthing lead burried directly in ground vertically (earth pit not less than 2.25mir deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, the earth plate surrounded by adequate quantity of charcoal dust and common salt to a packed thickness of 15 cm on all sides connected to Gl wire 4mm as earth lead by means of bolts, nuts, check nuts and washers (including welding) of galvanised iron or steel and connected to main switch board /DB/ test point at the other including necessary earth work in any type of soil, returning filling in and removal of surplus soil, concrete pit in PCC (1:3:6) type C1, pre cast RCC 1:2:4 type BI cover slab 54cm x 54cm x 5cm reinforce with 8mm dia bar TMT @150mm centre to centre both ways with one handle for lifting made out 8mm dia MS bar with wire mesh funnel, 20mm GI tubing medium grade for watering and 15mm Gl tubing light grade for protection including testing on completion all as shown in Electrical Plate No 3 of SSR Part-l complete all as specified and directed. |
| 120 | Supply, laying, jointing & testing in trenches or passing through pipe, 1100 volts grade, XLPE insulated PVC bedded, galvanized steel strip or wire armoured LT electric power UG cables, heavy duty with stranded aluminium conductor of cross sectional area 25 sqmm 4 core with and including all fixing & connecting accessories such as Alluminium cable lugs, cable gland, nut, bolts, washer etc complete all as specified and directed. |
| 121 | Excavation in trenches in soft/ loose soil n.exc 1.5 metre wide and n.exc 1.5 Mtr in depth and getting out for taking up / laying under ground electric cable complete all as specified and directed. |
| 122 | Supply and laying sub class B bricks of size 23cm x 115 cm x 7.5cm for protection of UG cable with width equal to length of bricks as mechanical protection laid dry and flat complete all as specified and directed. |
| 123 | M&L for 40 mm bore steel tubing light grade ISI marked for protection of cable including necessary joints complete all as specified and directed. Material and labour laying well burnt old size bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 23, 2026
11:30 IST
Tender Published
Tender notice published.
Completed
Aug 05, 2026
18:00 IST
Corrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
Upcoming · 6 daysAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender