Tender For Special Repairs To Various Stores Under Ge Golconda
Tender Overview
Project Description
Tender For Special Repairs To Various Stores Under Ge Golconda- 2 Dismantling Asbestos Cement (Corrugated, Semi Corrugated, Etc.) Sheets In Roof Coverings Complete All As Specified And As Directed. 3 Dismantling Timber Scantling In Fillets, Rails, Posts, Rafters, Purlins, Etc. Under 40 Sq. Cm In Section Complete All As Specified And As Directed. 4 Dismantling Timber Scantling 40 Sqcm And Over In Section, In Any Position Complete All As Specified And As Directed. 5 S&F Rolled Mild Steel Sections As In Roof Trusses, (Framed), Trussed Purlins, Rails, Vertical Posts And Fastenings And Heavy Bracket Framing (Beam, Tee, Angle, Channel, Tubular Or Flat Section) Including Distance Pieces, Cleats Confirming To Fe-410-W (Grade E-250 Quality A) Complete All As Specified And As Directed. 6 S & F Pre- Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Steel Sheet 0.50Mm Thick Of A Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws As Specified Etc. Complete All As Specified And As Directed. 7 S&F Pre-Painted Galvalume Aluminium Zinc Coating Gi Based Plain Steel Sheet 0.50Mm Thick Of Any Colour Having Tensile Strength Of 550 Mpa As In Roof Covering/Cladding To Wall, Fixed With Self Tapping Screws Complete All As Specified And As Directed. 8 Dismantling Boarding, Any Description, Fixed In Any Position With Nails Complete All As Specified And As Directed. 9 Demolition Of Brick / Stone Masonry, Built In Lime Mortar Including All Quoins, Arches, Pillars, Etc., But Excluding Ashlar Facings, Dressed Stonework And Precast Concrete Articles Etc. Complete All As Specified And As Directed.
BOQ
| Sl. No. | Item Description |
| 1 | BOQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) File No 8135/E8 Tender Inviting Authority: GARRISON ENGINEER GOLCONDA Name of Work: SPECIAL REPAIRS TO VARIOUS STORES UNDER GE GOLCONDA Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of work Item Code / Make No or Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder including all TaxesRs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc. Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words Represent (%) Percentage having Above/ Below ( + or - denomination) the Lump sum pre price inserted by MES |
| 2 | Dismantling Asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings complete all as specified and as directed. |
| 3 | Dismantling timber scantling in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section complete all as specified and as directed. |
| 4 | Dismantling timber scantling 40 Sqcm and over in section, in any position complete all as specified and as directed. |
| 5 | S&F rolled mild steel sections as in roof trusses, (framed), trussed purlins, rails, vertical posts and fastenings and heavy bracket framing (beam, tee, angle, channel, tubular or flat section) including distance pieces, cleats confirming to Fe-410-W (grade E-250 quality 'A') complete all as specified and as directed. |
| 6 | S & F Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of a colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified etc. complete all as specified and as directed. |
| 7 | S&F Pre-painted galvalume aluminium zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed. |
| 8 | Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed. |
| 9 | Demolition of brick / stone masonry, built in lime mortar including all quoins, arches, pillars, etc., but excluding ashlar facings, dressed stonework and precast concrete articles etc. complete all as specified and as directed. |
| 10 | M & L brick work with fly ash bricks built in CM 1:6 with Fly ash bricks straight or curved on plan exc 6 mtr mean radius complete all as specified and as directed. |
| 11 | M&L for Cutting chases in brick wall, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 10 cm but not exc 20cm girth complete all as specified and as directed. |
| 12 | Taking down cement plaster on brick wall/stone wall, ceilings, sunken floors etc., racking out joints, hacking for key & scrubbing with water completely complete all as specified and directed. |
| 13 | M&L for rendering 15 mm thick in CM 1:6 (1 cement : 6 clear river sand) on fair faces of brick surfaces of walls finished the surface fair and even and smooth complete all as specified and as directed. |
| 14 | M&L for rendering 15mm thick in two coats first coat 10mm thick in CM 1:6 (1 cement : 6 clear river sand) and second coat is 5mm thick in CM 1:4 (1 cement : 4 clear river sand) with WPC on second coat on fair faces of brick surfaces of walls finished the surfaces even & smooth without using extra cement complete all as specified and as directed. (NOTE : - WPC will be measured and paid separately) |
| 15 | M&L 5 mm thick plastering in CM 1:3 finished even and smooth w/o using extra cement on concrete surface of ceilings complete all as specified and as directed. |
| 16 | M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper over a coat of alkali-resistant primer and 1.5 mm thick with wall care putty on plastered surfaces complete all as specified and as directed. |
| 17 | M&L for preparation of newly plastered surfaces and applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new wall surfaces complete all as specified and as directed. |
| 18 | M&L for preparation of new plastered surfaces of ceiling and applying two coats of oil bound distemper over a coat of alkali-resistant primer and 1.5 mm thick wall care putty on plastered surfaces complete all as specified and as directed. |
| 19 | M & L for complete removal of existing treatment and applying two coats of weather proof exterior grade paint on prepared surfaces of walls complete all as specified and as directed. |
| 20 | M & L for complete removal of existing treatment and applying 1.5mm thick white wall care putty to fill up the depression and rubbing with sand paper to achieve a levelled and smooth surface and applying two coats of oil bound distemper over a coat of alkali resistant primer on prepared surfaces of internal walls complete all as specified and as directed. |
| 21 | M & L for preparation of old decorated surfaces of plastered or unplastered including removing by brooming down all dust, dirt and all loose scales by steel wire brushing, scrapping down smoke, soots, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying one coat of Oil bound distemper on ceilings, white or tinted complete all as specified and as directed. |
| 22 | M&L for cleaning/removing all vegetation, bushes/small trees on vertical side of wall/chajja/slab of building and making good the surfaces with PCC 1:2:4 type B-0 (12.5mm graded stone aggregate) or rendering in CM (1:3) including removing spoils obtained to a distance not exc 50 metre and depositing complete all as specified and as directed. |
| 23 | Cutting & trimming of tree branches any girth and size touching to sewage lines and cleaning the distance 1.5 mtr both sides of overhead line with in a gap of span 40 mtrs each and removing the same cleaning the site complete all as specified and as directed. |
| 24 | M&L for Cleaning of roof/ terraces (non accessible) including removal of dirt, mud, debris, shrubs, grass (if any) etc. and disposing off the waste outside of cantonment complete all as specified and as directed. |
| 25 | Demolition of PCC in Roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work of any description n.exc. 15cm thickness (Un re-inforced) complete all as specified and as directed. |
| 26 | M&L for PCC 1:2:4 (with clear river sand) type B0 (using 12.5 mm graded stone aggregate) as in roof padding finished even and smooth using extra cement with WPC complete all as specified and as directed. (NOTE : Supply of WPC will be paid under the respective Item) |
| 27 | Supply only Integral Liquid Water Proofing Compound complete all as specified and as directed. |
| 28 | M&L for APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyester non wove fabric (weight not less than 150 gms/sqm laid over primed surface including bituminous primer conforming to IS -3384 applied @ 0.3 ltrs/sqm by forced application over finished with one coat of aluminium paint @ 100 ml/Sqm, 10 cm overlap fused uniformly by LPG torch flame, including screeding / rendering 10mm thick in cm 1:4 (1 cement : 4 clear river sand) on concrete surfaces of roofs, parapet etc. finishing to surfaces even and smooth without using extra cement and providing necessary slope with using WPC @ 2% by weight of cement complete including taking down existing roof treatment and cement plaster of any description, roughing, preparing the surface by cleaning the surface with wire brushing scrubbing down with water to receive new treatment complete all as specified and as directed. |
| 29 | Surface excavation in hard dense soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out complete all as specified and as directed. |
| 30 | Dismantling of stone slab and tiles of any description or thickness in floors, aprons laid , bedded and pointed any mortar complete all as specified and as directed. |
| 31 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified and as directed. |
| 32 | Demolition of PCC in ground floor or paving of any description n.exc. 15cm thickness (Un re-inforced) below or above GL complete all as specified and as directed. |
| 33 | M & L for cement concrete 1:4:8 Type D2 (using 40 mm graded stone aggregate and with clear river sand) in sub bases, floors and pavings etc.,complete all as specified and as directed |
| 34 | M & L for 20-25 mm thick, Machine cut kota stone slab flooring over 20 mm thick cement screed bed in cement mortar 1:6 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including mirror polishing complete all as specified and as directed. |
| 35 | M & L for Machine cut Kota stone slab 20-25mm thick in riser of steps, skirting, dado and pillar laid over 10mm thick rendering in CM 1:4 screed and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing etc. complete all as specified and as directed. |
| 36 | M&L non skid coloured ceramic tiles 7-8 mm thick (square/ rectangular ) area of each tile exc 0.11 sqm but n.exc 0.18 sqm in floors etc., set and jointed in neat cement slurry and pointed with white or coloured cement to match the surface, laid over and including 15mm thick screed bed or bedding in cement mortar (1:6),complete all as specified and as directed. |
| 37 | M&L Glazed ceramic tiles in vertical surface 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match , laid over and including 10mm thick rendering in cement mortar(1:4) as backing coat, complete all as specified and as directed. |
| 38 | M & L Granite (with minimal / no flecks) work (table rubbed and polished) 20 mm thick in steps, jambs, pillars, window-cills, cooking platforms, over 15 mm thick screed bed in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, etc. complete all specified and directed. |
| 39 | M&L chequered cement concrete tiles 25 cm x 25 cm x 25 mm thick with grey cement and pigment, machine pressed : set, jointed and pointed in neat cement slurry in floors including 15 mm thick screed bedding layer in CM 1:6 complete all as specified and as directed. Make : Ultra or Classic or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 40 | M&L 40 mm thick cement concrete type B1, 1:2:4 (using 20 mm graded stone aggregate) in sub floors, sub bases, floors and pavings etc. finished even and smooth with using extra cement complete all as specified and as directed. |
| 41 | Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets any thickness, including cover fillets and grids and S&F for true horizontal level 600x600mm panels false ceiling system using hot dipped galvanized steel sections exposed surface with pre-coated capping, Main Tee of size 24x32mm at every 1200mm c/c maximum, rotary stitched cross Tee of size 24x 27mm at every 1200mm c/c and wall angle of size 19x19mm fixed to perimeter wall. The complete grid is to be suspended at every 1200mm c/c in both directions by using 2mm dia pre straightened GI wire at every 1200mm interval at the main Tee using fine finished angular edge including 8-9 mm thick Gypsum boards of size 600x600 mm with rear side Aluminium fril and front side PVC lamination complete all as specified and as directed. |
| 42 | M & L preparation of new steel surfaces description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 43 | M & L preparation of new wood surfaces description over 10 cm in width or girth applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed. |
| 44 | S & F Mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc. complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing, Fe 410-W (Gde-E-250) quality-A,etc complete all as specified and directed. |
| 45 | Taking down,Chowkhats or frames not exc. 1.5 sq. m each, etc. complete all as specified and as directed. |
| 46 | Taking down chowkats or frames with shutters ( without taking of shutter) from frame area exc 1.5 but n.exc 4 Sqm each complete all as specified and as directed. |
| 47 | M&L 2nd class hard wood plain straight solid chowkats and frames wrought, framed, rounded, chamfered put together with glue pinned joints and making good the surfaces complete all as specified and as directed. |
| 48 | S & F for 40mm thick flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and as directed. |
| 49 | M&L for cement concrete 1:2:4 type BI using 20mm graded stone aggregate in bed block for hold fasts and coping including necessary form work weathering slightly rounded or chamfered angles and treating and making good the disturbed portion complete all as specified and as directed. |
| 50 | S&F Double Rebate windows made of pre-painted steel (Base steel as per IS 513 of 0.58mm thick “D” Quality galvanized as per IS 277 with zinc of 120 GSM). Primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer. Section for outer frame should be of 72x55mm, centre mullion should be of 72x50mm, section for fixed glass beading should be of 12x12mm and section for shutter should be of 47mm x 20mm. Outer frame & mullion sections to have rebate for glazed shutters, fly mesh and 20 mm provision for guard bars/ grills, fly mesh shutter section should be of 20x40mm. The sections are to be cut to length mitre joined with corner bracket. Centre mullions to be fixed with mullion cap, Glazed Shutter section cut to length and mitre joint with corner bracket having lipping to cover the corners. Elixir, NCL or equivalent stay, handles, 2nos of heavy duty stain less steel pivot hinges, 2no’s tower bolts shall be provided per shutter. The windows should be panelled with 4mm thick plain float glass and S.S. Mesh for fly mesh shutter (304 grade). Rubber Gaskets are provided all around the glass. The above frames should be fixed to the concrete/masonry wall by means of self expanding screws. Including 10mm square guard bars with 6” (152.4mm) pitch, complete for finished item of work complete all as specified and directed |
| 51 | Supplying and fixing of Fixed Louvered Ventilators made of pre - painted steel (base steel as per IS 513 of -0.58 mm thick 'D\\" quality, galvanized as per IS 277 with zinc of 120 GSM) primer coated with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with 5-7 microns thick alkyd backer, The section for louvered ventilators should be of 33 x 56 mm Box section paneled with 4 mm pinhead glass with Ethyl propylene Diamine monomer Gasket (EPDM) and the sections cut to length mitre joined with corner bracket . Corner brackets made of CRCA with Zinc Phosphate. The frames to be fixed to the concrete/masonry wall by means of self expanding screws including 10 mm square guard bars with 6\\" pitch complete for finished item of work complete all specified and as directed.(Make : NCL / ELIXIR METFORM PVT LTD or techno commercially equivalent make as listed in list of makes and as approved by GE. |
| 52 | S&F Factory made single extruded WPC (Wood Polymer Composite) solid door/ window/ Ceosetory windows & other Frames/ Chowkhat of size 45 x 70 mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/ cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modules of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/ moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge and complete all as specified and as directed. (M.S. hold fast/ lugs or SS dash fasteners shall be paid for separately). →Note: For WPC solid door/window frames, minus 5mm tolerance in dimension i.e. depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made |
| 53 | S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer in Charge and complete all as specified and as directed. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately) |
| 54 | S&F of Butt hinges medium weight cold rolled mild steel and fixed in 125 mm complete all as specified and as directed. |
| 55 | S & F 150 mm length of extruded aluminium alloy handles, fabricated type., anodized complete all as specified and as directed. |
| 56 | S & F 200 mm length of aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and as directed. |
| 57 | S & F 300 mm long Aluminium alloy, anodized, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and as directed. |
| 58 | Demolition of Concrete of any description and in any position not otherwise specifically provided for, cement concrete (reinforced), etc. complete all as specified and directed. |
| 59 | M&L for Reinforced cement concrete Type B1, 1:2:4 (20 mm graded stone aggregate) in slabs supported on walls, beams, landings, balconies, canopies, deck slabs and, shelves and similar works etc. complete all as specified and as directed. |
| 60 | M&L for Reinforced cement B1, 1:2:4 (20 mm graded stone aggregate) in chajjas complete all as specified and as directed. |
| 61 | M&L for Reinforced cement B1, 1:2:4 (20 mm graded stone aggregate) in Beams, cantilevers, bressummers and lintels complete all as specified and as directed. |
| 62 | M&L for Formwork to soffits of suspended slabs of thickness not exceeding 200mm such as roof slabs, floor slabs, landings and similar work as flat finishing to fair finished surface of concrete complete all as specified and as directed. |
| 63 | M&L for formwork to small surfaces such as cantilever ends, brackets, ends of steps, caps and bases of pilasters and the columns and the like finishing to fair finished surface of concrete complete all as specified and as directed. |
| 64 | M&L for mild steel TMT bars 6 to 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9mm dia complete all specified and as directed. |
| 65 | M&L in repair 18mm thick plywood, grade 1 (with BWR resin) with one face veneered decorative fixed with brass screws and cups to timber frame work complete all as specified and as directed. |
| 66 | S & F Continuous (piano) hinges, mild steel, bright finish or electro galvanized, Width of flaps (when open) in 30 mm etc. complete all as specified and directed. |
| 67 | S & F for stainless steel handles, fabricated type, anodized, Size of handle in 150mm,etc complete all as specified and directed. |
| 68 | S & F mild steel work as in Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts of size 25x3MM MS flat; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 410-0 or Fe 310-0 complete all as specified and as directed. |
| 69 | Excavation in trenches n.exc 1.50m wide and n.exc. 1.50 m depth and getting out in hard/dense soil complete all as specified and as directed. |
| 70 | S & F 110 mm bore PVC (SWR) pipe single socketed, in any length with rubber ring joints, laid in trenches or in floors or fixed to wall including dismantling of old unserviceable one complete all as specified and directed. |
| 71 | S & F in repair PVC (SWR) bends any radius 110 mm dia, complete all as specified and as directed. |
| 72 | S&F in repair 110 mm bore PVC( SWR ) bend with oval access doors complete all as specified and directed. |
| 73 | S&F in repairs PVC (SWR) Vent cowl 110mm dia complete all as specified and as directed. |
| 74 | S&F in repair 75 mm PVC Nahani/ floor trap plain with grating including jointing with solvent cement complete all as specified and as directed. |
| 75 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. exc 25 cm complete all as specified and as directed. |
| 76 | Removing excavated material exc. 250 m but n exc. 1.5km and depositing where directed complete all as specified and as directed. |
| 77 | M & L treating the soil along with the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron., etc. complete all as specified and as directed. |
| 78 | Material and labour for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; etc. laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all specified and as directed. |
| 79 | Taking out carefully copper/aluminium point wiring,Light,fan, bell,socket or power complete with all fitting, fixtures such as switch socket out let, ceiling rose ,holder ,regulator, DBs, refixing of fans etc. including making good the disturbed surface of wall/floors complete all as specified and as directed. |
| 80 | Taking down existing service wire of any description and size including supporting wire, etc. complete all as specified and as directed. |
| 81 | M & L for providing point wiring with 1.5 sq. mm (nominal area) single core PVC insulated FRLS unsheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metallic rigid PVC conduit medium grade with appropriate size with all fittings (ISI Marked) suitable for concealed / surface wiring on stone/brick, masonry walls, roof etc. including modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one way modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including making good the disturbed surfaces to match with the existing specification, complete all as specified & directed at site for one light controlled by one switch. |
| 82 | All as per item No.81 above but for one ceiling fan controlled by one switch & regulator. |
| 83 | All as per item No.81 above but for one 3 pin socket 6 Amp on independent board. |
| 84 | All as per item No.81 above but for one 3 pin socket 6 Amp on same board. |
| 85 | All as per item No.81 above but for One 3 pin 15 Amps switch socket outlet point on independent board with 4.0 sqmm PVC (FRLS) insulated unsheathed single core multi stranded copper conductor complete all specified and as directed. |
| 86 | Supply and fix Modular switch, single pole, one way, 6 Amps one module complete all as specified and directed. |
| 87 | Supply and fix Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and directed. |
| 88 | Supply and fix Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed. |
| 89 | Supply and fix Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed. |
| 90 | Supply and fix Ceiling rose surface bakelite three terminal / PVC / Polycarbonate / isolated body 65x50 mm, terminals 240 volts complete all as specified and directed. |
| 91 | Supply and fix modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed. |
| 92 | Supply and fix 20W,decorative, wall mounted, ultra slim, LED lighting fixture size (1224x 43x58)mm, 6500K with high lumen output, environmental friendly, energy efficient with electronic driver complete with all fixing arrangement including connection with twin twisted unsheathed PVC copper cable of suitable size etc., complete all as specified and as directed. |
| 93 | Supply and fixing LED BLDG Security Light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 66 protection including connection with twin twisted unsheathed PVC copper cable of suitable size along with suitable brackets with clamps, nuts and bolts complete all as specified and as directed. Makes: Havells Cat No. ENDURASUNDOWNSL35W LED765 PASYB OPC or techno commercially equivalent make in Philips/ Wipro/ Bajaj/ makes listed in list of makes as approved by GE. |
| 94 | S&F in repair LED light fittings, 1x10 watts bulk head luminaires, IP66 complete with all accessories and including connecting up with twin core twisted flexible PVC copper conduct cable of 23/0.0076 from ceiling rose complete all specified and as directed. |
| 95 | S&F in repair Factory made SPN 8 ways distribution board in sheet steel enclosure double door with suitable rated bus bar, 240 Volts suitable for housing RCBO SPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. |
| 96 | S&F in repair Factory made SPN 4 ways distribution board in sheet steel enclosure double door with suitable rated bus bar, 240 Volts suitable for housing RCBO SPN MCBs as incomer and SP MCBs as outgoing complete all as specified and as directed. |
| 97 | S&F in repair 240V, 10 KA 'C' curve MCB of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed at site. |
| 98 | Supply and fix in repair RCBOs SPN 32 Amp, 240 volts 50Hz AC supply, in the MCB DB Complete with connection testing and commissioning complete all specified and directed. |
| 99 | Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less1.5 mtrs below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point including necessary earth work, excavation PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber provision of PCC cover 40 mm thick 1:2:4 mm type B1, funnel with 20 mm dia medium grade GI pipe for water, 15mm dia medium grade protection pipe for GI earth lead, testing after completion complete all as specified and as directed. |
| 100 | S & F 1100 volts grade heavy duty cable PVC insulated aluminium conductor 16 Sqmm, served with inner sheathing of PVC sheathed in service connections suspended by insulating hangers not more than 1 meter including 4mm suspension wire, one twin core cable fiat or circular including taking down/dismantling of one complete all as specified and as directed. |
| 101 | S & F Mild steel rod for ceiling fans of 3 Feet to 5 Feet as per site requirement long duly screwed threads with check nuts & pin for celling fan complete all as specified and as directed |
| 102 | S & F hanging hooks for fixing the fans of suitable length complete all as specified and as directed |
| 103 | Taking down ceiling fan of any sweep, painting of ceiling fans with blades complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust and refixing of ceiling fan & connecting up including provision of cable from ceiling rose or connector to fan etc. complete all as specified and as directed. Total in Figures 0.0 0.0 INR Zero Only Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender