Tender For Internal & External annual repair & maintenance of Of T. E. Building, Bodla, Ba Agra.
Tender Value
2.11 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
2 days left
EMD
4222
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Agra → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Internal & External annual repair & maintenance of Of T. E. Building, Bodla, Ba Agra.
BOQ
| Sl. No. | Item Description |
| 1 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : |
| 2 | 1:2:4 (1 cement : 2 coarse sand(zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 3 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 4 | Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: |
| 6 | 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 7 | Repairing of Aluminium door shutter with frame for smooth operation including taking out door with frame, dismembering aluminium door sections, taking out panelling, reassembling the door shutter with required aluminium cleats /iron flat /iron angle with screws, rivets & refixing the available panelling in position with snap beading thereafter refixing the shutter in position with necessary fixtures including pivots , necessary screws etc,all complete as directed by the Engineer In charge. (a) Single or Double Shutter up to 3.00 Sqm area |
| 8 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 9 | (i)Single socketed pipes. |
| 10 | 110 mm diameter |
| 11 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. |
| 12 | Bend 87.5° |
| 13 | 110 mm bend |
| 14 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. |
| 15 | 110 mm |
| 16 | Grading roof for water proofing treatment with |
| 17 | Cement mortar 1:4 (1cement : 4 coarse sand) |
| 18 | Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer-in-Charge. |
| 19 | 15 mm cement plaster on rough side of single or half brick wall of mix : |
| 20 | 1:6 (1 cement: 6 coarse sand) |
| 21 | White washing with lime to give an even shade: |
| 22 | New work (three or more coats) |
| 23 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer, of required shade and colour all complete : |
| 24 | New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre |
| 25 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 26 | New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 27 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 28 | Two or more coats on new work. |
| 29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 30 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and of required shade and colour complete to give and even shade. |
| 31 | Old work (one or more coats) |
| 32 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. |
| 33 | One coat. |
| 34 | White washing with lime to give an even shade : |
| 35 | Old work (one or more coats) . |
| 36 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 37 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : |
| 38 | One or more coats on old work. |
| 39 | Finishing walls with Acrylic Smooth exterior paint of required shade : |
| 40 | Old work (One or more coat applied @ 0.90 ltr/10 sqm). |
| 41 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-harge. |
| 42 | With cement mortar 1:4 (1cement: 4 coarse sand). |
| 43 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 44 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/sqm). |
| 45 | Flush pointing with cement mortar 1:3 (1 cement : 3 fine sand) mixed with 2% of integral water proofing compound by weight of cement for flat tile bricks on top of mud phaska : |
| 46 | With F.P.S. brick tiles |
| 47 | Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, including marking the date of cleaning on the side of tank body with the help of stencil and paint and disposing of malba, all complete as per direction of Engineer-in-Charge. (The old date already written on tank should be removed with paint remover or black paint and if date is not written with the stencil or old date is not removed deduction will be made @ Rs. 0.10 per litre if during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account) |
| 48 | Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150mm dia upto 300mm dia for all depth. |
| 49 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 50 | 10 litre capacity - White |
| 51 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. |
| 52 | Flexible pipe |
| 53 | 32 mm dia |
| 54 | Providing and fixing PTMT bib cock of approved quality and colour. |
| 55 | 15mm nominal bore, 86 mm long. Weighing not less than 88 gms. |
| 56 | Providing and fixing PTMT angle stop cock 15 mm nominal bore. Weighing not less than 85 gms. |
| 57 | Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. |
| 58 | 15 mm nominal bore with 45 cm length. |
| 59 | Cleaning of terrace / spouts / khurras / canopies / blocked chajjas including removal of algae, fungal element etc., by iron brush, broom, bleaching powder etc, and removing leaves, grass, dust, rubbish and other deposited and accumulated material etc.,also disposal of rubbish to dumping ground up to a lead of 50m.,all complete as per direction of E-I-C. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 25, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 2 daysJul 28, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 5 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender