Tender For Repair And Rehabilitation Of Old Agri Godown And Eastern Portion Of South Facing Reinforced Cement Concrete Building To Differently Abled Intervention Centre In Cheranmahadevi Panchayat Union Office Premises
Tender Value
13.20 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
18 days left
EMD
13200
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tirunelveli → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Rehabilitation Of Old Agri Godown And Eastern Portion Of South Facing Reinforced Cement Concrete Building To Differently Abled Intervention Centre In Cheranmahadevi Panchayat Union Office Premises
BOQ
| Sl. No. | Item Description |
| 1 | Earthwork excavation and depositing on bank with an initial lead of 10m and lift of 2m in the following classification of soils as directed by TWAD Board officers. |
| 2 | Cipping of concrete and roughening the surface and cleaned away from the site including cost of all labour charges etc., complete.(Ref.:- PWD SOR 2024-2025, Annex III- Rates of works - Unique Code- W-0036 (Page-28)) |
| 3 | Dismantling the existing Brick/Stone masonry walls in cement mortar under 3m height and cleaned away from the site including cost of all labour charges etc., complete.(Ref.:- PWD SOR 2024-2025, Annex III- Rates of works - Unique Code- W-0015 (Page-27)) |
| 4 | Cement concrete 1:4:8 (one cement four sand and eight aggregates) using 40mm HBGS for levelling course for foundation including the cost of mixing concrete, ramming, curing etc., complete as directed by TWAD Board officers. |
| 5 | Filling the basement with EXCAVATED EARTH including cost and conveyance of all materials and all labour charges etc complete. |
| 6 | Brick work using country bricks of size 83/4\\"x41/4\\"x23/4\\" in cement mortar 1:5 (One cement and five sand) including curing neat finishing, etc., complete complying with standard specifiction. |
| 7 | Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three M.Sand) base mortar over the existing slab / floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg. / sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 8 | Paving the floor with pre-polished concrete anti-skid tiles (Required shape and design) of 20mm thick of approved quality and colour laid in Cement Mortar 1:3 (One Cement and Three crushed stone sand) 20mm thick and pointed with white cement mixed with colouring pigment at the rate of 0.40 Kg. / sq.m., curing, etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) Using anti-skid tiles (Observed Data) |
| 9 | Tactile Paver type of New tek BT Yellow colour Ceramic tiles of size 305x305x15mm for vision Impairment personProviding and filling the tile joint with epoxy grout with following specification |
| 10 | plastering with Cement Mortar 1:5 (One cement and Five sand), 12mm thick in all floors including curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 11 | Distempering the old walls and ceiling one coat with best oil bound distemper of approved quality including preparation of surfaces (the colour and quality should be got approved by the Executive Engineer before use) the rate includes cost of brushes, high scaffolding charges, neat finishing, cost of brushes etc., complete complying with standard specification and as directed by the Departmental Officer |
| 12 | Re Painting the walls with Two coats with first class quality Plastic Emulsion paint of approved colour over a priming coat including thorough scraping, clean removal of dirt. The rate includes cost of brushes, sand paper, plaster of parries, putty wherever required and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) S I No 358 |
| 13 | Painting the old iron works two coats with syntactic enamel paint of approved quality and colour including ordinary scraping using brushes and neat finishing etc., complete complying with standard specification and as directed by the Departmental Officer (the colour and quality should be got approved by the Executive Engineer before use) |
| 14 | Supply and fixing of Steel door and window cost and labour charges |
| 15 | Window W 0.90*1.30m |
| 16 | Door 2.30*2.30m |
| 17 | Providing, fabricating and fixing M.S. grills Windows, and ventilator,gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer. |
| 18 | Providing UPVC (Un-Plasticized Polyvinyl Chloride)Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of2.4mm. The window unit should be designed with allcorner joints mitred and fusion welded. Windowsshould be steel reinforced with 25 x 24 x 25mm steelreinforcement with a thickness of 1mm to havedimensional stability. The sash should be of 60 x102mm. The mullion should be of 60 x 74mm. Theprofiles should have co-extruded seals.Hardware: All the hardware like friction stays, handlesshould be screwed with self tapping screws. Thehandles, locks should be designed so that they cannotbe released from outside.Glazing: The window system should be glazed with5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length andwelded 45 degrees. The window should be designedsuch that the water drainage does not pass throughthe reinforcement chamber. The window systemshould be fixed directly to the plastered brick wallusing self expanding nylon plug and driving mselectroplated screws into plug |
| 19 | UPVC Window supplying and fixing UPVC ( Un-PLASTICIZED Polyvinyl chloride) windows of casement type (open) from the profile the size of outer frame 60mmx58mm and shutter profile are reinforcement with g/1mm 125GSM and 100% corrosion free, the profiles are multi chambered section with wall thick of 2mm. The EPDM rubber (black color) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power points locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed or plain glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. |
| 20 | Labour chrges for fixing of steel door of size |
| 21 | Labour chrges for fixing of steel window,ventilatore of size |
| 22 | Supplying and painting two coats new iron work such as steel doors ventilators, window bars etc., (WITHOUT PRIMER) |
| 23 | Supplying and fixing colour galvalume sheet roof of 0.47mm thickand steel tubular box section of 100x50x3mm of 1meter interval including priming coat fixing in position with all necessary accessories complete complying with standard specification and as directed by the departmental officers. |
| 24 | Making new truss using new mateials of 'L' angle of size 35x35x6mm including cutting the angle to the required length drilling holes wherever necessary for fixing the pipe purlins, rafters and fixing the post etc., complete. |
| 25 | Providing and fixing GYP board false ceiling and fixing with a new Gyp board False ceiling which includes 'U' shaped GI channels of size 25x25x0.5mm thick |
| 26 | Fabrication supply and fixing in position of Aluminium natural colour matt finish partition of wall |
| 27 | Wiring with 2 x 1.5 sq.mm. PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigidpipe on wall and ceiling with PVC accessories and with TW switch box and 5A FT switch with painting of suitable colourfor open PVC light point / fan point (for electronic regulator) (5 points per coil) (SD 18) |
| 28 | Wiring with 2 x 1.5 sq.mm PVC insulated SC unsheathed FRLS copper conductor of 1100V grade in suitable PVC rigid pipe on wall and ceiling with PVC accessories with 150 x 100 x 113mm TW switch box for 5A 3 pin non inter locking Wallsocket with 5A flush type switch with painting of suitable colour with continuous earth wire connection of 1.5 sq.mm copper wire for open PVC plug point (SD 36) |
| 29 | Wiring with 2 x 4 sq.mm. PVC insulated SC unsheathed FRLS copper conductor cable of 1100V grade in suitable pipe onwall and ceiling with PVC accessories with 150mm x 100mm x 113mm TW switch box for 15A 3 pin non inter locking wallsocket with 15A flush type switch with painting of suitable colour with continuous earth wire connection of 4 sq.mmcopper wire for open PVC power plug point SD 39 |
| 30 | Supply and run off 2 of 4 sqmm PVC insulated single core unsheathed copper conductor cable of 1100 V grade with ISI mark confirming to IS:694/1990 with continious earth connection by means of 1.50 sqmm PVC insulated single core unsheathed copper conductor cable confirming to IS:694/1990 in suitable PVC rigid pipe 1.8mm thick concealed in wall for mains including the cost of PVC pipes and specials, cables, cement, brass screws, T.W plugs, saddles and labour etc., complete in all respects as directed by the departemental officers. (derived from SD 57) |
| 31 | Supply and run of 1 of No.8 SWG GI wire for earth connection (SD74) |
| 32 | Supply and fixing for 9W LED BULB SD 80 |
| 33 | Supply and fixing of WT bulk head fitting with guard (Philips / Bajaj / Crompton / K-Lite) suitable for 15W CFL (SD83) |
| 34 | Supply and fixing of single box type 4'40 W flu fitting complete with copper choke and condensor with conduit pipe suspension from the ceiling with PVC unsheathed copper leads from terminals tot he fitting with tube SD88 |
| 35 | Supply and fixing of 4'40W twin box type fluorescent fittting complete with copper choke and condensor with conduitpipe suspension from ceiling with PVC unsheathed FRLS copper leads from terminals to the fitting with fluorescent Tubes SD 91 |
| 36 | Supply and fixing of 1200mm (48\\")sweep AC ceiling fan complete with stepped electronic 300W regulator with the existing down rod on the existing clamps. (SD 110) |
| 37 | Supply and fixing of 1400 mm (56\\") sweep AC ceiling fan complete with stepped electronic regulator with 300 mm down rod on the existing clamp (SD 111) |
| 38 | Supply and fixng of TNEB meter board suitable for 3 phase 200A service connection made up of suitable angle iron frame work of size 3 feet x 2 feet using angle iron of size 1-1/2\\" x 1-1/2\\" x 1/4\\" rigidly fixed on wall covered with hylem sheet of size 3 feet x 2 feet of 12mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos. 200A fuse units (500V), 1 No. neutral link, copper earth flat of size 1\\" x 1/4\\" with inter connection of EB meter to fuse units by 19/16 PVC insulated copper wire with earth connection complete SD 131 |
| 39 | Supply and fixing of 5A / 15A 3 pin combined flush type wall socket with 15A flush type switch on suitable TW Box (SD 136) |
| 40 | Supply and fixing of 5A / 15 A 3 Pin combined flush type wall socket with 15A flush type switch concealed in suitable MS Box in flush with wall and covered with 3 mm thick hylem sheet(SD 138) |
| 41 | Supply and fixing 16amps DP switch with metal clad(side handle) of 500 V with F & N on suitable teak wood Board of size 30cmx20cmx6 cm including necessary internal conection,earth connection etc.,complete (SD 142) |
| 42 | Supply and fixing of 20A Flush type Wall Socket 32A DP MCB complete set for AC Plug in flush with wall with earthconnection (For AC Plug) SD 144 |
| 43 | Supply and fixing of 32A TPNMC switch with suitable angle iron frame work with MS cable entry boxes with earth connection only (SD148) |
| 44 | Supply and fixing of horizontal type 4 way triple pole neutral MCB distribution board in sheet steel enclosure double door(metal) with 40A 4 pole MCB isolater as incoming and 12 Nos. 6A to 32A SP MCB as outgoing in flush with wall andmaking good of the concealed portion with earth connection. The MCBDB and MCB's should be with the ISI mark (likestandard make) SD 157 |
| 45 | Earthing as per the ISI specification with an earth electrode of 2.10 metre Class 'B' GI pipe of dia not less than40mm with copper earth plate of size 125mm x 50mm x 6mm with necessary funneling arrangements withnecessary masonry work and with 38mm RCC cover slab for the brick masonry (SD221) |
| 46 | Supply and fixing of 8 way single pole and neutral MCB sheet steel enclosure distribution board with doubledoor (metal) 1 No. 32A DP MCB as incoming and 6 Nos. 6A to 32A SPMCB outgoing in flush with wall andmaking good of the concealed portion with earth connection only. The MCB DB and MCB's should be with ISImark (like standard make) (SD 515) |
| 47 | Supply and fixing of 4 way Vertical Triple pole and neutral MCCB sheet steel enclosure distribution board ( with MCCBIncomer ) with double door (metal door ) with 1 No 160 A 4 P MCCB as incoming and 2 Nos 63A 3P MCB , 6 Nos 6A to 32A SP MCB as outgoing with suitable cable end box on wall with Earth connection only. Higher End SD 609 Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 17, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender