Educational and Research Institute Government Departments Closing in 9 days TDR #56511386

Tender For Development Of Infectious Diseases Research And Diagnostic Laboratory (Irdl) In Medical Lab Building (5Th Floor) At Aiims Nagpur

Issued by Government Departments · nagpur, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
30 Jul 2026
9 days left
EMD
2.10 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
nagpur → Maharashtra
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Development Of Infectious Diseases Research And Diagnostic Laboratory (Irdl) In Medical Lab Building (5Th Floor) At Aiims Nagpur

BOQ

Name of Work:- Development of Infectious Diseases Research and Diagnostic Laboratory (IRDL) in Medical Lab Building (5th floor) at AIIMS Nagpur
Sl. No. Item Description
1Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
2Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
3Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles 10 mm to 25 mm
4Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
51:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
6Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
7Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
8Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
9Providing 12 mm cement plaster of mix : (1:6) (1 cement: 6 sand)
10Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand)
11Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
12Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm
13Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite work
14Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For fixed portion Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
15For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) : Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron)
16Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board onforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer in-charge. Pre-laminated particle board with decorative lamination on both sides
17Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
18Providing and fixing ISI marked S.S. tower (Barrel type) with necessary screws etc. complete and as per the directions of Engineer-In-Charge. (250 x 10 mm)
19Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
20Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with Isl, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete (Make Godrej or equivalent)
21Providing and fixing \\"H\\" type Stainless Steel (304 grade) stain finished pull handle of approved fixing accessories, wood and metal doors. The pull handles should have supporting washer with raised bevelling on the outer surface, SS 304 grade.
22Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete
23Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
24Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturer's specification. Two or more coats on new work
25Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead as directed by Engineer-in-charge
26Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. - Size of Tile 600x600 mm Wall and Cladding Works
27Providing and fixing mineral fibre false ceiling tiles (supply of 595*595 mm tiles of approved make), exisiting ceiling tiles grade to be fixed if damaged
28Providing & fixing false ceiling at all height including providing & fixing of framework made of special section, power pressed from M.S. sheets and galvanised with zinc coating of 120 gms/ sqm (both side inclusive) as per IS : 277 and consisting of angle cleat of size 25mm wide x 1.6mm thick with flanges of 27mm and 37mm, at 1200mm c/c, one flange fixed to the ceiling with dash fastener 12.5mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25 x10 x0.50mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I chanels 45 x15 x 0.90mm running at the spacing of 1200 mm c/c, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having lips of 10.5mm, at 450mm c/c, shall be fixed in a direction perpendicular to G.I intermediate channel with connecting clip made out of 2.64mm dia x 230mm long G.I wire at every junction, including fixing perimeter channels 0.50mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/ partitions with the help of Rawl plugs at 450mm centre, with 25mm long dry wall screws @ 230mm interval, including fixing of Calcium Silicate Board to ceiling section and perimeter channels with the help of dry wall screws of size 3.5 x25mm at 230mm c/c, including jointing & finishing to a flush finish of tapered and square edges of the board with recommended jointing compounds, jointing tapes,finishing with jointing compounds in three layers covering up to 150mm on both sides of joints and two coats of primer suitable for boards, all as per manufacture's specification and also including the cost of making opening for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specificaton and direction of the Engineer in charge but excluding the cost of painting with: 8 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process
29Providing and fixing Permanently Static Dissipative pressed homogeneous vinyl flooring (EN 649) ,anti static, wear layer thickness is 2mm (EN429), PVC Vinyl flooring having Carbon backing a with total weight 3000 g/m2 (EN 430), XR PUR (polyurethane reinforced) ,Abrasion group P:≤4,0mm, residual indentation approx. 0,02 mm, castor wheel test qualified, dimensional stability ≤0.40%,static electrical charge < 2kv, good resistance of scratch, slip, chemical and fire, doesn’t favor in growth of fungi. Electric resistance is as per EN 1081 and ESD approved. Restorable properties. Available in rolls. 100% recyclable. Low VOC emission after 28days of installation (lower than ≤100μg/m3). Non Directional in Design. The flooring should be laid on the .05 mm thick copper grid having grid of the size of 1mtr x 1 mtr.The grid is connected with earth point
30Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :610x460 mm bowl depth 200 mm (making Connection from Existing line including drain and supply of water inlet and outlet required all pipes and fittings, tools and acessories complete)
31Providing and fixing C.P. Sink Cock with regular Swinging Spout (Table mounted model) of approved quality conforming to IS standard and as per the directions of Engineer-in-charge. Code FLR-CHR-5357N of Jaquar or other equivalent make
32Providing and fixing C P brass waste coupling 32 mm size half threaded with 80 mm height with fittings of approved quality, make and design as per the directions of Engineer-in-Charge (Make Jaquar - ALD-709 or equivalent)
33Providing and fixing in position under counter and overhead Storage cabinets made with 25 x 50 mm MS pipe with insert Wooden Batta and shutter & Shelf made in 0.8 mm thick CRCA sheet, all epoxy polyster powder coated. Including all fixtures, fasteners and locking arrangement system, etc complete as per approved shade and colour including concealed (Zero Crank) hinge of approved quality for with stainless steel screws complete : (Make Hattich/ godrej or Equivalent) & fixing bright /matt finished 125 mm Stainless Steel handles of approved quality & make with necessary screws etc all complete.
34Providing & fixing of Stainless steel static Pass Box in walls / granite surface / Aluminnium work including making good the wall / filling of gaps in bet aluminium section etc complete as per direction of engineer in charge.Size 230 X 230 X 295 mm (ID)/400 X 400 X 400 mm (OD)
35Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. 200 A,36KA,FPMCCB
36Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 50 sq. mm (35 mm)
37SITC of MCCB Drawout Enclosure Panel along with all accessories
38SITC of 50 sq mm 4 core Aluminium Armoured Power Cable along with all accessories
39SITC of 200 A Bus bar box along with all accessories
40Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way (4 + 24), Double door
41Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. For 8 way, Double door TPN MCBDB
42Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 A
43Supplying and fixing following rating, double pole,(single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
44Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
45Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
46Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
47Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
48Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
49Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
50Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS/HFFR PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire
51Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required. Group C
52LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm) 36 watt
53LED Panel light 2x2 ft. (System lumen efficacy ≥105 <120 lm/Watt)Supplying, installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
54Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
55Supply, Installation, Testing & Commissioning (SITC) of 4.0 TR Ceiling Mounted 4-Way Cassette Type Inverter Air Conditioner of minimum 3-Star BEE rated, complete with indoor and outdoor units, high-efficiency inverter compressor, copper condenser and evaporator coils, built-in condensate drain pump, wireless remote controller, washable air filters, factory-charged R-32 / R-410A refrigerant with PCB of both IDU & ODU should be in mettalic box for fire protection, power contactors of suitable rating complete as required by Engineer in charge. and all standard accessories at existing false ceiling complete as required by Engineer in charge.
56Supply, Installation, Testing & Commissioning (SITC) of 2.0 TR Ceiling Mounted 4-Way Cassette Type Inverter Air Conditioner of minimum 3-Star BEE rated, complete with indoor and outdoor units, high-efficiency inverter compressor, copper condenser and evaporator coils, built-in condensate drain pump, wireless remote controller, washable air filters, factory-charged R-32 / R-410A refrigerant with PCB of both IDU & ODU should be in mettalic box for fire protection, power contactors of suitable rating complete as required by Engineer in charge. and all standard accessories at existing false ceiling complete as required by Engineer in charge.
57supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.52 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations with OEM standards of VRV/VRF air conditioning system complete.
58supplying, laying/fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.88 mm dia (OD) for liquid line/suction line supply and return piping of suitable gauge (hard copper pipe for liquid main line and soft copper pipe for refrigerant) along with necessary supports, hangers, clamps,vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19mm thick elastomeric nitrile rubber along with application of multicoating of VRV/VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultraviolet radiations withOEM standards of VRV/VRF air conditioning system complete.
59Providing, laying, testing and commissioning of 4 Core × 2.5 sq.mm FRLS PVC insulated , PVC sheathed, 1100 V grade copper conductor cable conforming to IS 694/ IS 1554, laid on surface/in existing cable tray/conduit, with plug top complete with necessary fixing accessories, glands, lugs, ferrules, dressing and termination as required.
60Outdoor standfabrication :-Supply, fabricationand erection of angle/channel/flat iron stand, hanging arrangement for air conditioning machines & ducts etc, back/ support clamps or other similar work etc. including nut bolts of required size, making holes, fabrication,welding, cutting, etc. and painting with one coat of red oxide paint & two coat of enamel paint as required as per specification.
61Drain piping :-Providing and fixing of CPVC, 6Kg/cm2 drain water piping of 32mm diameter with fittings, support and insulated with 6mm thick closed cell elastomeric nitrile rubber insulation complete as per
62Supplying and installation following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastener etc as required. 225 mm width X 50 mm depth X 1.6 mm thickness
63Supplying, installation, balancing and commissioning of factory fabricated GSS sheet metal rectangular/ round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, bends, transitions, reducers, end caps, collars etc as required complete in all respect in confirmation to IS : 655 and approved drawings and specifications of following sheet thickness complete as required. factory fabricated 1.0 mm GSS sheet metal rectangular ducting as per IS 655-2006
64Supplying and fixing of following thickness duly laminated aluminium foil of mat finish closed cell Nitrile rubber (Class \\"O\\") insulation on existing duct after applying suitable adhesive for Nitrile rubber. The joints shall be sealed with 50 mm wide and 3 mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Nitrile rubber Insulation - 25 mm
65Supplying, Fixing, installation, testing and commissioning of supply air diffusers of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required.
66Supplying, Fixing, installation, testing and commissioning of Return air diffusers of powder coated aluminium without volume control dampers with anti smudge ring & removable core in confirmation to SMACNA/IS and as per specifications complete etc. as required. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56511386
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 30-07-2026
Authority
Authority Name All India Institute Of Medical Sciences
Work Description Tender For Development Of Infectious Diseases Research And Diagnostic Laboratory (Irdl) In Medical Lab Building (5Th Floor) At Aiims Nagpur
Basic Detail
Tender No 29/AIIMS/NAG/ENGG/26-27
Bidding Type Tender
Location
City nagpur
State Maharashtra
Key Dates
Publish Date 16 Jul 2026
Submission Date 30 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 2.10 Lakhs
Exemption Available
Document List
BOQ_964483.xls
Tendernotice_1.pdf
5f963d79-9d6f-41fb-ad5a-bd53ebf1ed9e.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 30, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 9 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_964483.xls

pdf

Tendernotice_1.pdf

html

5f963d79-9d6f-41fb-ad5a-bd53ebf1ed9e.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders