Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Manufacturing Unit; Unloading, Installation, And Hook Up Of Fat Iat Plate Cooler And Bfw Preheater And Hook-Up Of Intermediate Absorption Tower (Iat
Tender Overview
Project Description
Bids Are invited for Repair, Maintenance, And Installation Of Plant/ Systems/Equipments (Version 2) - Manufacturing Unit; Unloading, Installation, And Hook Up Of Fat Iat Plate Cooler And Bfw Preheater And Hook-Up Of Intermediate Absorption Tower (Iat) In Sap And Cna Plan.. - Lump Sum Charges For Unloading Of The Bfw Preheater Along With Spares. Charges Forcrane Required For The Job Are Inclusive. , Lump Sum Charges For Complete Job Of Replacement Of Bfw Preheater In Sap Plant Asper Scope Of Work. Charges Are Inclusive Of:• Scaffolding Erection And Removal.• Cutting Of The Required Ducts/Pipelines / Structure.• Opening And Box-Up Of The Required Flanges/Manholes.• Spading / Blinding Of Flanges And Removal Of Spades / Blinds And Final Box-Up As Perthe Above Scope Of Work.• Removal Of The Bfw Preheater And Installation Of New Bfw Preheater In Position.This Also Includes Charges For Crane Required For Replacement Of Exchangers.• Loading / Unloading And Shifting Of The Piping, Structural Steel And New Bfwpreheater From Stores / Expansion Yard To Sap Plant.• Loading / Unloading, Weighing And Shifting Of The Removed Old Bfw Preheater Fromsap Plant To Expansion Yard.• Charges For Truck / Trailer And Crane Required For Loading / Unloading And Shifting Ofthe Piping, Structural Steel And Bfw Preheatercharges For Crane Required For Installation Of The Pipelines And Structures. , Charges For Fabrication Of Ss Ducting (Ss304); Size: 40 (Root Run And Hot Pass Will Be Intig Welding And Subsequent Fill-Up Passes Will Be In Arc Welding) (Charges Are Inclusiveof Scaffolding, Dye Penetrant Testing Of The Root Run And Final Run) , Lump Sum Charges For Unloading Of The Fat Plate Cooler Along With Spares. Charges Forcrane/Hydra Required For The Job Are Inclusive. , Lump Sum Charges For Complete Job Of Installation Of Fat/Iat Plate Cooler In Sap Plantas Per Scope Of Work. Charges Are Inclusive Of:• Installation Of New Fat Plate Cooler In Position. This Also Includes Charges Forcrane/Hydra Required For Installation Of Exchangers.• Loading / Unloading And Shifting Of The Piping, Valves And Structural Steel From Stores/ Expansion Yard To Sap Plant.• Charges For , Hook Up Of Iat With Crane/Hydra In Contractor Scope. , Fabrication And Erection Of Ss304 Ducting , Cutting And Removal Of Ss304 Duct , Installation Of Acid Distributors And Candles (Which Includes Installation Of Cast Irontrays(03 Nos.) ,Cast Iron Distribution Header And Iat Candles (09 Nos). , Erection Of Ms Ptfe Pipelines , Fabrication And Erection Of Cs/Ss Pipelines (Size: 1 To 6 ) , Replacement Of Valves (Cs/Ss/A20/Msptfe)150# , Up To 2 , 3 To 6 , 8 To 10 , Structural Repair And Replacement
BOQ
| Sl. No. | Item Title | Item Description |
| 1 | Lump sum charges for unloading of the BFW preheater along with spares. Charges forcrane required for the job are inclusive. | Lump sum charges for unloading of the BFW preheater along with spares. Charges forcrane required for the job are inclusive. |
| 2 | Lump sum charges for complete job of replacement of BFW preheater in SAP Plant asper scope of work. Charges are inclusive of:• Scaffolding erection and removal.• Cutting of the required ducts/pipelines / structure.• Opening and box-up of the required flanges/manholes.• Spading / blinding of flanges and removal of spades / blinds and final box-up as perthe above scope of work.• Removal of the BFW preheater and installation of new BFW preheater in position.This also includes charges for crane required for replacement of exchangers.• Loading / Unloading and shifting of the piping, structural steel and new BFWpreheater from Stores / expansion yard to SAP Plant.• Loading / unloading, weighing and shifting of the removed old BFW preheater fromSAP Plant to expansion yard.• Charges for truck / trailer and crane required for loading / unloading and shifting ofthe piping, structural steel and BFW preheaterCharges for crane required for installation of the pipelines and structures. | Lump sum charges for complete job of replacement of BFW preheater in SAP Plant asper scope of work. Charges are inclusive of:• Scaffolding erection and removal.• Cutting of the required ducts/pipelines / structure.• Opening and box-up of the required flanges/manholes.• Spading / blinding of flanges and removal of spades / blinds and final box-up as perthe above scope of work.• Removal of the BFW preheater and installation of new BFW preheater in position.This also includes charges for crane required for replacement of exchangers.• Loading / Unloading and shifting of the piping, structural steel and new BFWpreheater from Stores / expansion yard to SAP Plant.• Loading / unloading, weighing and shifting of the removed old BFW preheater fromSAP Plant to expansion yard.• Charges for truck / trailer and crane required for loading / unloading and shifting ofthe piping, structural steel and BFW preheaterCharges for crane required for installation of the pipelines and structures. |
| 3 | Charges for fabrication of SS ducting (SS304); size: 40” (Root run and hot pass will be inTIG welding and subsequent fill-up passes will be in arc welding) (Charges are inclusiveof scaffolding, Dye Penetrant testing of the root run and final run) | Charges for fabrication of SS ducting (SS304); size: 40” (Root run and hot pass will be inTIG welding and subsequent fill-up passes will be in arc welding) (Charges are inclusiveof scaffolding, Dye Penetrant testing of the root run and final run) |
| 4 | Lump sum charges for unloading of the FAT plate cooler along with spares. Charges forcrane/Hydra required for the job are inclusive. | Lump sum charges for unloading of the FAT plate cooler along with spares. Charges forcrane/Hydra required for the job are inclusive. |
| 5 | Lump sum charges for complete job of installation of FAT/IAT plate cooler in SAP Plantas per scope of work. Charges are inclusive of:• Installation of new FAT plate cooler in position. This also includes charges forcrane/Hydra required for installation of exchangers.• Loading / Unloading and shifting of the piping, valves and structural steel from Stores/ expansion yard to SAP Plant.• Charges for | Lump sum charges for complete job of installation of FAT/IAT plate cooler in SAP Plantas per scope of work. Charges are inclusive of:• Installation of new FAT plate cooler in position. This also includes charges forcrane/Hydra required for installation of exchangers.• Loading / Unloading and shifting of the piping, valves and structural steel from Stores/ expansion yard to SAP Plant.• Charges for |
| 6 | Hook up of IAT with crane/hydra in contractor scope. | Hook up of IAT with crane/hydra in contractor scope. |
| 7 | Fabrication and erection of SS304 ducting | Fabrication and erection of SS304 ducting |
| 8 | Cutting and removal of SS304 duct | Cutting and removal of SS304 duct |
| 9 | Installation of acid distributors and candles (which includes installation of cast irontrays(03 Nos.) ,cast iron distribution header and IAT candles (09 nos). | Installation of acid distributors and candles (which includes installation of cast irontrays(03 Nos.) ,cast iron distribution header and IAT candles (09 nos). |
| 10 | Erection of MS PTFE pipelines | Erection of MS PTFE pipelines |
| 11 | Fabrication and erection of CS/SS pipelines (Size: 1” to 6” ) | Fabrication and erection of CS/SS pipelines (Size: 1” to 6” ) |
| 12 | Replacement of valves (CS/SS/A20/MSPTFE)150# | Replacement of valves (CS/SS/A20/MSPTFE)150# |
| 13 | Up to 2” | Up to 2” |
| 14 | 3” to 6” | 3” to 6” |
| 15 | 8” to 10” | 8” to 10” |
| 16 | Structural repair and replacement | Structural repair and replacement |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender