Housing Urban and Rular Development Government Departments Closing in 10 days TDR #56509699

Tender For Special Repairs To 30 Bed Roof Leakage, Ot Roof Leakage In Primary Health Centre At Thadikarankonam In Kanniyakumari District.

Issued by Government Departments · Kanniyakumari, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2026
10 days left
EMD
20000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kanniyakumari → Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Special Repairs To 30 Bed Roof Leakage, Ot Roof Leakage In Primary Health Centre At Thadikarankonam In Kanniyakumari District.

BOQ

Name of Work:- Special Repairs to 30 Bed roof leakage, OT roof leakage in Primary Health Centre at Thadikarankonam in Kanniyakumari District.
Sl. No. Item Description
1Dismantling, clearing away and carefully stacking materials useful for re-use for any thickness of Weathering course pressed tiles etc complete
2Clean removal of Cement plaster from walls etc complete.
3Chipping the concrete and roughening the surfaces etc complete.
4Thorough scrapping of old plastered surfaces etc., complete Complying with stabndard specification.
5Plain Cement Concrete 1:2:4 (one cement, two crushed stone Sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.
6Re-roofing with old machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
7Re-roofing with new machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
8Re-Pointing with old machine pressed tiles in Cement Mortar 1:3 (One Cement and Three crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers
9Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers.
10Special ceiling plastering and finishing the exposed surface of all RCC items of work such as slabs, beams, sunshades, facia, canopy slab, staircase waist slab, landing slab etc., with Cement Mortar 1:3 (One Cement and Three Plastering Sand) 10mm thick including mortar plasticizer at 200ml per 50Kg of cement used , hacking the surfaces and curing, etc., in all floors complying with standard specification and as directed by the departmental officers
11Painting Old Plastered Wall Surface with Two finishing coats of ready mixed Exterior plastic Emulsion paint of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
12Painting Old Plastered Wall Surface with Two finishing coats of ready mixed interior plastic Emulsion paint of approved quality and colour over the existing wall in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
13Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.)
14Supply & fixing of WPC door shutter, extruded as a single core board with rigid WPC compound with the thickness of 25mm (+/- 1mm) & minimum Bulk Density of 550 KG/Cub.Mt. & shore hardness of 55. The door shall be a plain matt board as decided by the Engineer in-Charge of the department. The WPC door shall be fixed onto the Aluminium “G” type channel with Wheel and the door shall have 2 Hooks in SS, 2 Handles 4” in SS (Sliding door) etc., complete and as directed by the departmental officers.
15Supplying and fixing in position Glazed steel ventilator with Side/Central hung shutters( Two Leaves) frames and made shutter frame made out of steel section conforming to IS 7452 /1990.The outer frame made out of z section (F7D) of size 33 x22 x3 mm conforming to IS 7452/1990.The mullions are made out of (F4B) section of size 46x25x3 mm and conforming to IS7452/1990.The shutters are individual and each of them can be operated separately.Sash bars are made of T section (T2) of size 25 x 22 x 3mm 2 nos of sturdy hinges and one number of handle cum latch of special type are fixed are each openable shutter with suitable opening in left for its easy operation, one member of adjustable strings with fixing brackets of sufficient length are provided for each shutter 4 nos of 40 x 40 x 3 mm angle hold fast 200mm length are welded with the frame at appropriate point M.S Square bars of 12 mm dia is welded to the inner face of the ventilator at equal intervals not exceeding 10 cm spacing 3mm pin headed glass is used for Glazing with good quality anf fixed with 15 x 12 mm teak wood beadings with screws for fixing .The shutters are to open outside. All the section are given with one coat of red oxide primeretc., complete complying with standard specification.The sample of materials and fittings shall be got approved by the departmental officers before use on work.The rate shall inclusive of cost all materials labour charges one coat of primer,weld charges, including cost of welding electrodes,transportation to site work, loading,unloading and incidental charges etc., complete complying with standard specification and as directed by the departmental officers
16Supplying and laying of Interlocking Paver Block Stone 60mm thick Over a base layer of crushed stone dust filling including Cost of materials laying and Labour charges etc complete complying with the standard specification and as directed by the departmental officers.
17Supplying and fixing in position white glazed European Water Closet of best quality and approved make with 100 mm \\"P\\" or \\"S\\" trap connecting with CI pipe of 100mm dia / PVC pipe of 110mm dia, double flapped rigid PVC black seat and seat cover with CP brass hinges including cost of white cement, cement for packing, spun yarn, teak wood plugs, brass screws, etc., including supplying and fixing 10 litres capacity PVC / 12.5 litres capacity porcelin low level flushing tank with a pair of CI brackets, etc., complete with all fittings such as 15mm brass ball valve with polythene float with brass handle, union, coupling connected by means of 40mm white PVC flush hand using Indian adopter joint including all internal fittings..such as 15mm brass connections, 15mm GM wheel valve, 15mm brass nipple (2 Nos.), 15mm nylon connection, TW plugs, screws and also giving necessary connection to the PVC pipe including cost of 600mm length of 110mm dia PVC pipe and painting the CI brackets with 2 coats of approved paint over one coat of red oxide primer, dismantling the masonry and re-doing the dismantled masonry to original condition etc. complete complying with standard specifications. (The EWC and flushing tank wiht all accessories should be got approved by the Executive Enginer before use on works)
18Supplying and fixing in position 15mm dia brass CP Screw down tap / Pillar tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works)
19Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 110mm dia pipe
20Towards charges for painting letters of size 1.50 x 0.75m base coat over Tamil & English letters changes to all materials, scaffolding and labour charges etc complete.
21GST Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56509699
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 31-07-2026
Authority
Authority Name public works department
Work Description Tender For Special Repairs To 30 Bed Roof Leakage, Ot Roof Leakage In Primary Health Centre At Thadikarankonam In Kanniyakumari District.
Basic Detail
Tender No e-Tender Notice No. 2(4) / C.8.1 / 230M / 2026-27 Dt.14.07.2026
Bidding Type Tender
Location
City Kanniyakumari
State Tamil Nadu
Key Dates
Publish Date 16 Jul 2026
Submission Date 31 Jul 2026
Open Date 31 Jul 2026
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 20000
Exemption Not Available
Document List
5e31a5c7-bb83-4e13-b79f-363a2e2eddc3.html
BOQ_824940.xls
TD20Thadikkarankonam.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Jul 31, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 10 days

Tender Documents

Download All (ZIP) ↓
html

5e31a5c7-bb83-4e13-b79f-363a2e2eddc3.html

xls

BOQ_824940.xls

pdf

TD20Thadikkarankonam.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders