Tender For Repair And Renovation Work In Sivasagar Civil Hospital, Joysagar, Assam Under Assist Project
Tender Value
11.82 Crore
Estimated cost
Bid Submission
17 Aug 2026
16 days left
EMD
23.66 Lakhs
Bank guarantee accepted
Document Fee
20000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kamrup Metro → Assam
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair And Renovation Work In Sivasagar Civil Hospital, Joysagar, Assam Under Assist Project
BOQ
| Sl. No. | Item Description |
| 1 | SIVASAGAR CIVIL HOSPITAL |
| 2 | 2.0 SIVASAGAR CIVIL HOSPITAL |
| 3 | FIRE EXTINGUISHERS |
| 4 | Providing & Fixing of fire extinguishers with necessary accessories, stand, trolley, etc. 6 Kg ABC (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 ISI Marked portable fire extinguisher, 4.5kg CO2 type fire extinguishers complete in all respect including initial fill and wall suspension brackets & shall conform to IS 2878 or latest IS 6Kg DCP (Powder Type) Fire Extinguisher. In HP Mild Steel Cylinders ISI marked fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged with ABC powder (Mono Ammonium Phosphate) pressured by Nitrogen complete in all respects including wall suspension bracket and conforming to IS:15683 ISI marked (IS:15683) portable chemical fire extinguisher, Foam type capacity 9 liters with gun metal cap and nozzle and complete in all respects including initial fill and wall suspension brackets Supplying and installing at approved location approved make fire buckets (3nos./set) of 24 gauge galvanized steel sheet, standard 9 litre capacity and of round bottom shape, painted white inside and black on the bottom, inscribed with letters '' FIRE'' in black and gold with dry clean fire sand. The scope shall also include the stand for mounting the sand bucket. 5Kg. Clean Agent Ceiling Mounted Type Fire Extinguisher, Working Temperature -30°C to +60°C, Cylinder Testing Pressure 35 bar for 30sec., Operating Pressure 8 bar, Bulb Temp.68°C Standard, Area Coverage of 3x3 mtr., Propellant uses of Dry Nitrogen and type of Charge Clean Agent HFC-236fa (Including Internal Server & Ups Room .) |
| 5 | EARTHWORK |
| 6 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. All kinds of soil |
| 7 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 8 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. All kinds of soil |
| 9 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 10 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. |
| 11 | SAND FILLING |
| 12 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 13 | SOLING WORK |
| 14 | Dry brick on edge flooring in required pattern with bricks of class designation 7.5 on a bed of 12 mm mud mortar, including filling joints with Jamuna sand, with common burnt clay non modular bricks. |
| 15 | P.C.C WORKS |
| 16 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 17 | D.P.C work |
| 18 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 19 | RCC WORK |
| 20 | Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 21 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from naturalsources : 3 graded stone aggregate 20 mm nominal sizederived from natural sources) |
| 22 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 23 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement. All works upto plinth level Concrete of M25 grade with minimum cement content of 330 kg /cum All works above plinth and upto floor V level Concrete of M25 grade with minimum cement content of 330 kg /cum |
| 24 | Add for using extra cement in the items of design mix over and above the specified cement content therein. |
| 25 | FORMWORK |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete Walls (any thickness) including attached pilasters, butteresses,plinth and string courses etc. Suspended floors, roofs, landings, balconies and access platform Lintels, beams, plinth beams, girders, bressumers and cantilevers Columns, Pillars, Piers, Abutments, Posts and Struts |
| 27 | STEEL REINFORCEMENT |
| 28 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 30 | BRICKWORK |
| 31 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 32 | Brick work with common burnt clay modular bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 33 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand) |
| 34 | Providing and laying Autoclaved Aerated concrete (AAC) blocks masonrywith 150mm/ 230mm/ 300 mm thick with Grade-I AAC blocks of density551 to 650 kg/ cum conforming to IS: 2185 (Part 3) in super structure above plinth level up to floor V level with RCC band at sill level and lintellevel with approved block laying polymer modified adhesive mortar allcomplete as per direction of Engineer-in-Charge. (The payment of RCCband and reinforcement shall be made for seperately). |
| 35 | DOORS |
| 36 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). Second class teak wood |
| 37 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 30 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 38 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 plyveneering with vertical grains or cross bands and face veneers on bothfaces of shutters 35 mm thick including ISI marked Stainless Steel butt hinges with necessary scr |
| 39 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): Rectangular or square |
| 40 | Float glass panes of nominal thickness 5 mm (weight not less than 12.50 kg/sqm) |
| 41 | DOORS FITTINGS |
| 42 | Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete : 300x16 mm 250x16 mm |
| 43 | Providing and fixing ISI marked oxidised M.S. tower bolt black finish, (Barrel type) with necessary screws etc. complete : 100x10 mm |
| 44 | Providing and fixing ISI marked oxidised M.S. handles conforming to IS:4992 with necessary screws etc. complete : 125 mm |
| 45 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10 mm |
| 46 | Providing and fixing bright finished brass door latch with necessary screws etc. complete : 300x16x5 mm |
| 47 | Providing and fixing bright finished brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. |
| 48 | Providing and fixing bright finished brass handles with screws etc. complete: 125 mm |
| 49 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. |
| 50 | Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete. |
| 51 | Providing and fixing chromium plated brass handles with necessary screws etc. complete: 125mm |
| 52 | STRUCTURAL STEEL WORKS |
| 53 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes |
| 54 | Providing and fixing M.S. fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete. |
| 55 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 56 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 57 | ROOFING |
| 58 | Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275 gm/ m² |
| 59 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete. 0.63 mm thick with zinc coating not less than 275 gm/m² |
| 60 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer- in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 61 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) |
| 62 | PLASTERING |
| 63 | 20 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 64 | 12 mm cement plaster of mix 1:4 (1 cement: 4 coarse sand) 1:6 (1 cement: 6 coarse sand) |
| 65 | 15 mm cement plaster on the rough side of single or half brick wall of mix : 1:4 (1 cement: 4 coarse sand) 1:6 (1 cement: 6 coarse sand) |
| 66 | 12 mm cement plaster finished with a floating coat of neat cement of mix: 1:3 (1 cement: 3 fine sand) 1:4 (1 cement: 4 fine sand) |
| 67 | 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix : 1:4 (1 cement: 4 fine sand) |
| 68 | PUTTY AND PRIMER WORK |
| 69 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 70 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 71 | EXTERNAL PAINTING |
| 72 | Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm) |
| 73 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqmover and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) |
| 74 | INTERNAL PAINTING |
| 75 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats |
| 76 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats |
| 77 | WOOD AND STEEL PAINTING |
| 78 | Applying priming coat With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 79 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 80 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road markingb paint of superior make as approved by the engineer-in-charge, including cleaning the surface of all dirt, scales, oil, greas and other foreign materials etc. and lining out complete. New work (Two or more coats) |
| 81 | FLOORING & SKIRTING/ DADO |
| 82 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 83 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mm |
| 84 | GRANITE FLOORING |
| 85 | 62 mm thick cement concrete flooring with concrete hardener topping,under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top laye 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete |
| 86 | Providing and laying Polished Granite stone flooring and tread of steps in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent |
| 87 | ANTISKID TILES |
| 88 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Glazed Vitrified tiles Matt/Antiskid finish of size Size of Tile 600 x 600 mm |
| 89 | WALL TILES |
| 90 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. |
| 91 | SS RAILING |
| 92 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). |
| 93 | ALUMINIUM WINDOWS AND OTHER WORKS |
| 94 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) For fixed portion Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 95 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 96 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm) |
| 97 | Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays of approved quality with necessary stainless steel screws etc. to the side hung windows as per direction of Engineerin- charge complete. 205x19mm |
| 98 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Anodized (AC 15) aluminium tubular handle bar |
| 99 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 100 | PLINTH PROTECTION WORKS |
| 101 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed andconsolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 102 | WATER PROOFING |
| 103 | Repair of spalled concreteProviding and Applying a two component structural grade polymer modified reinstatement mortar Fosroc Renderoc S2 or equivalent up to a thickness of 20 mm over a epoxy rasin bonding agent Nitobond EP. The cured mortar shall achieve a compressive strength of 12 N/mm² in 1 day & 45 N/mm² in 28 days with Flexural strength 8 N/mm² in 28 days. Chloride diffusion coefficient shall be Nil after 24 hours when tested by Accelerated Electrochemical chloride ion diffusion test method and the depth of carbonation shall be Nil after 24 hours when tested by Accelerated carbonation test. In addition to this percentage of water absorption should be 0.45 after 24 Hrs in immersion test. |
| 104 | Epoxy GroutProviding and Sealing the cracks, in the concrete surface, after opening the cracks using suitable tools or saw cut in the crack, and cleaning the interior sides of the crack using sharp tools to remove all loose materials, using two component, high strength, non-sag, epoxy compound Nitobond PC 40 of fosroc make, inclusive of all Manpower, Material and Equipment. Injection Of Low Viscous Resin: BY Providing and grouting the cracks after fixing the injection ports at predetermine locations with the help of suitable injection grouting pumps at suitable pressures using two-component, high strength, low viscous epoxy injection resin system such as Conbextra EP 10 of Fosroc inclusive of Manpower, Material and Equipment\\". (Mode of measurement: Per litre of grout consumption. |
| 105 | Providing, Supplying, transporting materials, drilling holes by rotary hammer drill, dust removing, batching, mixing of resin and hardener, inserting & anchoring rebars of specified dia in existing concrete surfaces using polyester resin based anchoring grout like Fosroc Lokfix E75 or equivalent and necessary re baring of reinforcement steel up to 200mm depth( Cost of the reinforcement will be charged extra) 12 mm Dia |
| 106 | FALSE CEILING |
| 107 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) : 2011 (Board with BIS certification marks) |
| 108 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \\"T\\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \\"T\\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main T at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \\"T\\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main T runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. GI Metal Ceiling Lay in plain Tegular edge Global white color tiles of size 595x595 mm, and 0.5 mm thick with 8 mm drop; made of G I sheet having galvanizing of 100gms/sqm (both sides inclusive) and electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS: 2095 part I, of size 595x595 mm, having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48 mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. |
| 109 | DISMANTALING WORKS |
| 110 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Nominal concrete 1:4:8 or richer mix (i/c equivalent design mix) |
| 111 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 112 | Demolishing R.B. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. |
| 113 | Extra for cutting reinforcement bars manually/ by mechanical means in R.C.C. or R.B. work (Payment shall be made on the cross sectional area of R.C.C. or R.B. work) as per direction of Engineerin |
| 114 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar |
| 115 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : Of area 3 sq. metres and below |
| 116 | Dismantling cement asbestos or other hard board ceiling or partition walls including stacking of serviceable materials and disposal of unserviceable materials within 50 metres lead. |
| 117 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 118 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: |
| 119 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 120 | WIRE MESH |
| 121 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete. With 2nd class teak wood beading 62X19 mm |
| 122 | PU PAINT |
| 123 | Providing two coats of White cement putty, Epoxy based primer of Pro Epi Shield Floor Sealer (20 micron), Top coat Aqua green WB PU Finish White (60 micron) to fnishing including scaffolding, Brush, Roller, Sand Paper, Silk Roller & Carring charges etc. |
| 124 | HPL OT Door |
| 125 | Double Leaf HPL (Pre- Painted Galvanized Steel) Skin Insulated Clean Room Door with 44 mm Door thickness with HPL Skin on both sides with pressure injected High Grade PIR as Door Blade core material with Ano alu Door Frame, Rubber Gasket Non Particle Shredding Type Seal, Drop Seal, Double Insulated Glass Vison panel 300x300mm, Ball Bearing Hinges, Door Closer on active leaf, Door Lock and SS 304 Door Handle D-Type for smooth passage. Size : 1500×2100 mm |
| 126 | SIGNAGE |
| 127 | Steel Letter (Outdoor Quality)Specification: 304 Stainless Steel Letter with 20 Gauges. Thickness of the letter : 2.50 Inch Depth/ Raise Size Of Letter: 1.5 Inch (20'' Height X125Nos=2500 Inch) |
| 128 | Supplying and installing of in position the following type of sign boards made out of 3mm thick \\"Opaque\\" PVC foam board with computer cut, PVC reflective self adhesive vinyl painted foam board, complete with mirror fasteners. Signage with printed \\"IN CASE OF FIRE, USE STAIRS UNLESS INSTRUCTED OTHERWISE\\" of 1.5cm height letters in red with white back ground. The size of the board shall be 25cm x 30 cm and shall be fixed at the height of 2 mts. from finished floor near Manual call points. |
| 129 | Fire Exit signage- Double sided: 150 x 400Providing and fixing \\"Fire Exit\\" letters signage (with or without directional arrows as per signage plan, ref. by architect). Signage to be made of 3 mm thick foam board with edge to edhe self-adhesive, self luminiscent Forex or equivalent inyl stuck on it. Fix green vinyly to cover Forex vinyl leaving 6 mm border around edges with Exit letters cut-out. The exit letters shall be 150 mm height. Double side false ceiling suspended with chain look and hook. Unidirectional, printed both sides with sinle arrow or double arrow. |
| 130 | Supplying and installing of in position the following type of sign boards made out of 3mm thick \\"Opaque\\" PVC foam board with computer cut, PVC reflective self adhesive vinyle painted foam board, complete with mirror fasteners. Department wise marking |
| 131 | INTERNAL ROAD- PAVER BLOCK |
| 132 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 133 | Supplying and stacking at site. 63 mm to 45 mm size stone aggregate 53 mm to 22.4 mm size stone aggregate |
| 134 | Laying, spreading and compacting stone aggregate of specified sizes to WBM specifications in uniform thickness, hand picking, rolling with 3 wheeled road/vibratory roller 8-10 tonne capacity in stages to proper grade and camber, applying and brooming requisite type of screening / binding material to fill up interstices of coarse aggregate, watering and compacting to the required density . |
| 135 | Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 |
| 136 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. |
| 137 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). |
| 138 | INTERNAL WIRING |
| 139 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 140 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 141 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2x2.5 sq.mm + 1 x 2.5 sq.mm earth wire (For 6A Power Point looping & Switchboard to Switchboard looping) 2 x 4 sq.mm + 1 x 4 sq.mm earth wire ((For 6/16A Power Point looping) |
| 142 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 143 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. |
| 144 | Supplying and fixing of following sizes of medium class PVC conduit along with acessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20 mm 25 mm |
| 145 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 146 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A |
| 147 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 A switch 3 pin 5/6 A socket outlet |
| 148 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS: 374-2019), THO less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required |
| 149 | Supply and laying of 25mm X 5mm G.I. strip at 0.5 mtr below ground as strip earth electrode including connection/termination with GI Nut-Bolt & Spring Washer etc as required(Jointing Shall be done by overlapping and with 2sets of GI Nut-Bolt & spring washer spaced at 50mm) |
| 150 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 151 | Providing and fixing 6 SWG dia. G.I. wire on surface or in recessed for loop earthing as required |
| 152 | Supplying, installation, testing & commissioning of exhaust fans 300 mm. sweep. 230volt, 50Hz single phase A/C supply and complete with all standard accessories s (As per make list / atrchitect choice) |
| 153 | Supply, installation testing, commissioning of 20W LED TUBE LIGHT including Luminaire housing and all fixing acceessories (As per make list / atrchitect choice) |
| 154 | Supply, installation testing, commissioning of 12W surface/ recess MOUNTED DOWN LIGHT including Luminaire housing and all fixing acceessories (As per make list / atrchitect choice) |
| 155 | DIESEL GENERATOR |
| 156 | Supply, installation testing, commissioning of 300 KVA Silent DG set outdoor type complete with acoustic enclosure , fuel tank, fuel piping, engine directly coupled with alternator 3 - Phase 415V, 1500 rpm , 0.8 p.f. , 50Hz, engine control panel residential silencer, anti vibration mountings pad etc., charged battery with leads,earthing and first fill of oil and lubricants as per specifications . Including Liaison fees Necessary Statutory Approval from (NOC ‐ POWER UTILITY, DOE & PCB). Also includes supply, fabrication and errection of DG exhaust 150/200 mm dia MS piping including necessary rock wool insullation (64kg/m3), Al. cladding over the insullaion including silencer and necessary support , scaffolding arrangement . DG AMF panel also included |
| 157 | Supply & Installation of 100 KVA , 3P+N in/out, 415V system, 50HZ, Modular UPS ( 25 x 3 nos), Input Voltage range 400V +15%/-20% - 230V +15%/-20% , Output Voltage range -380, 400, 415V selectable, Low THD Double conversion efficiency up to 96.8%Efficiency in ECO mode up to 99%.Output power factor = 1Hot-swappable modules.Modular redundancy in N+1 configuration.Intelligence distributed between modules.UPS Power capacity upto 25KW x 3 moduleDecentralised by-pass.Reduced battery charging times. BMS compatible with open protocol communicable, remote monitoring interface, 30 mins backup ( for 50 KVA) with 12V SMF battery, built in redundancy with all accessories, Battery racks, interconnecting cables etc. |
| 158 | EXTERNAL ELECTRICAL |
| 159 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, refilling the trench etc as required. protective covering and 3 x 4 sq. Mm ( upto 35 sqmm) |
| 160 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as reauired. 3 x 4 sq. Mm ( upto 35 sqmm) additional cable |
| 161 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, \\"C\\" curve, minature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. single pole |
| 162 | Earthing with G.I. earth pipe 4.5mtr long,40mm dia including accessories and providing masonry encloser with cover plate having locking arrangement and watering pipe etc.with charcoal or coke and salt complete as required (IS : 3043-1987), (Panel earthing + Lightning protection) |
| 163 | Supply and laying of 25mm X 5mm G.I. strip at 0.5 mtr below ground as strip earth electrode including connection/termination with GI Nut-Bolt & Spring Washer etc as required(Jointing Shall be done by overlapping and with 2sets of GI Nut-Bolt & spring washer spaced at 50mm) |
| 164 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. Above 4.5 metre and upto 6.5 metre |
| 165 | LIGHTING FIXTURES |
| 166 | Supply & fixing of 30W LED street light Wipro LR02-331-XXX-57-XX or equivalent |
| 167 | Supply of decorative hot dipped galvanised mild steel step pole 6mtrs. height with grey powder finish. Compatible for street light. Window - Plasma cut & duly chamfered opening window of300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole ( Excluding civil work). Havells make or equivalent. |
| 168 | SUPPLY OF MV CABLES |
| 169 | Supply of XLPE insulated power cable (conforming IS-7098 Part-I) 1100 Volt grade, 1 core/2 core/3½ core/4 core ISI marked with alu. stranded /solid conductor 4 sq. mm. 3 core Cu. Arm. XLPE cable |
| 170 | TERMINATION OF MV CABLES |
| 171 | Supplying and making end termination with brass compression gland and copper lugs for following size of PVC insulated and PVC sheathed / XLPE copper conductor cable of 1.1 KV grade as required 4 sq. mm. 3 core Cu. Arm.XLPE cable |
| 172 | SUPPLY OF FEEDER PILLAR, OUTDOOR |
| 173 | Supplying, installation, testing & commissioning of cubical Feeder Pillar type double door, floor mounted, IP65, suitable for 415V, 3 Phase, 4 Wire 50 Hz AC supply system of suitable size fabricated in compartmentalized design from CRCA sheet steel of 2 mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing ,powder coating in approved shade, having 63 A capacity aluminium bus bars of high conductivity, Short circuit withstanding capacity of 16 KA, DMC / SMC bus bar supports, bottom base channel of MS section not less than 75 mm x 75 mm x 5 mm thick, entire panel shall have a common GI earth bar 25mm x 5mm at the rear with 2 Nos. earth stud, connections from main bus bar to switch gears with required size of copper conductor/single core cable and control wiring with 1.5 sq. mm. PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing and fixing of following switchgear and components complete as required. (I)Incomer1) 32 Amp, FP,10 kA MCB with -1 nos2) LED type phase indicating lamps with 2 Amps SP MCBs for Instrument Protection(II) Outgoing :-(i) ML 1.5 Contactor with control wiring and connector block etc. : 1 set(ii) Digital astronomical timer switch -1 No(iii) 10 Amp SP MCB, 10 KA - 12 Nos |
| 174 | INTERNAL PLUMBING |
| 175 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid |
| 176 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap White Vitreous China Surgeon type wash basin of size 660x460 mm with single 15 mm C.P. brass pillar taps with elbow operated levers ISI Marked |
| 177 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. |
| 178 | Providing and fixing stainless steel A ISI : 304 (18/8) kitchen sink as per IS : 13983 with CI brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required. Kitchen sink without drain board 610 x 510 mm bowl depth 200 mm |
| 179 | Providing and fixing C.P. brass chain and rubber plug complete for sink or wash basin: 32 mm dia |
| 180 | 15 mm C.P. brass tap with elbow operation lever |
| 181 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. [for Basin / Urinal / Sink waste] 40 mm dia 50 mm dia |
| 182 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms. |
| 183 | Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. |
| 184 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 : |
| 185 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 |
| 186 | Providing and fixing soil, waste pipes : Hubless centrifugally cast (spun) iron pipes epoxy coated inside & outside IS:15905 100 mm dia 75 mm diameter : vent pipes : |
| 187 | Providing and laying S&S centrifugally cast (spun) iron pipes (Class LA) conforming to IS - 1536 : (For RWP) 100 mm dia pipe 150 mm dia pipe |
| 188 | Providing and fixing M.S. holder-bat clamps of approved design to sand cast iron / cast iron (spun) pipes embedded in and including cement concrete blocks 10 x 10 x 10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including cost of cutting holes and making good the walls, etc. For 100mm diametre For 75mm diametre |
| 189 | Providing and Fixing shielded coupling for Hubless centrifugally cast iron pipe. 100 mm SS 304 grade coupling with EPDM Rubber gasket. |
| 190 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete. Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 100 mm dia |
| 191 | Providing and fixing plain bend of required degree. 100 mm dia |
| 192 | Providing and fixing double equal plain junction of required degree. 100x100x100x100 mm |
| 193 | Providing and fixing single equal plain junction of required degree : 100x100x100 mm |
| 194 | Providing and fixing double unequal plain junction of required degree : 100x100x75x75 mm |
| 195 | Providing and fixing single unequal plain junction of required degree : 100x100x75 mm |
| 196 | Providing and fixing double equal plain invert branch of required degree: 100x100x100x100 mm |
| 197 | Providing and fixing single equal plain invert branch of required degree : 100x100x100 mm |
| 198 | Providing and fixingHubless centrifugally cast (spun) iron terminal guard (slotted cowl) -100 mm dia as per IS 15905 |
| 199 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors : 100 mm inlet and 100 mm outlet Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 |
| 200 | Cutting holes up to 15x15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishing complete so as to make it leak proof. |
| 201 | Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 12.50 mm nominal size), including necessary plaster and pointing in cement mortar 1:4 (1 cement : 4 coarse sand). 100 mm 50 mm |
| 202 | Painting sand cast iron/centrifugally cast (spun) iron soil, waste vent pipes and fittings with paint of any colour such as chocolate, grey or buff, etc., over a coat of primer (of approved quality) for new work. 100mm diametre pipe |
| 203 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge 15 mm nominal dia Pipes 50 mm nominal dia Pipes |
| 204 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 205 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gms |
| 206 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore |
| 207 | WATER SUPPLY |
| 208 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.(Concealed Work) 15 mm nominal outer dia Pipes 20 mm nominal outer dia Pipes 25 mm nominal outer dia Pipes 32 mm nominal outer dia Pipes 40 mm nominal outer dia Pipes |
| 209 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm nominal dia Pipes 25 mm nominal dia Pipes 32 mm nominal dia Pipes 40 mm nominal dia Pipes 50 mm nominal dia Pipes 65 mm nominal dia Pipes |
| 210 | Providing and fixing ball valves (brass) of approved quality, High or Low pressure with plastic floats complete. 15 mm nominal bore 20 mm nominal bore 25 mm nominal bore |
| 211 | DISMANTALING WORK FOR PLUMBING |
| 212 | Disconnecting damaged overhead/terrace PVC water storage tank of any size from water supply line and removing from the terrace including shifting at ground level as per direction of Engineer-in-charge. |
| 213 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials i/c malba all complete as per directions of Engineer-in Charge |
| 214 | Dismantling 15 to 40 mm dia G.I. pipe including stacking of dismantled pipes (within 50 metres lead) as per direction of Engineer in-Charge. (a) Internal Work- Exposed on wall |
| 215 | Dismantling G.I. pipes (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge : 15 mm to 40 mm nominal bore Above 40 mm nominal bore |
| 216 | Dismantling C.I. pipes including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes & lead at site within 50 metre lead as per direction of Engineer-in-charge: Up to 150 mm diameter Above 150 mm dia up to 300 mm dia Above 300 mm diameter |
| 217 | Dismantling of flushing cistern of all types (C.I./PVC/Vitrious China) including stacking of useful materials near the site and disposal of unserviceable materials within 50 metres lead. |
| 218 | Dismantling of C.I. sluice valve including stacking of useful materials within a lead of 50 metres Up to 150 mm diameter Above 150 mm diameter |
| 219 | Over Head Tank Pump |
| 220 | Supply, installation & commissioning of 2 Nos.vertical Inline Multi Stage Centrifugal Pump for Clear Water Transfer with 50Hz, 380-415V, 2 Pole IE3 efficiency class motor (As per IEC standard). Pump shall be CI with CED quoted- Head & Base, SS 316 -Shaft and all other components will be with SS 304, Mechanical Seal (SiC vs SiC face) . Pump should have minimum 70% efficiency. (Motor Make-Siemens/ABB/Schnidler) Pump controller suitable for 2 Pumps (1W+1S) with LCD screen displays, phase loss protection (incoiming as well as for outgoing), Individual pump overload protection, individual pump under voltage protection, dryrunning protection without installing any float switch, memory function when power off and during recovery, visual and audio alarm for fault prompt, auto manual switch, and pump should operate based on the OHT water level and both pump should run together for high level. Panel should come with 2 Nos Float switch to work as per the sump water level. Flow Rate-17 m3/hr (1W+1S)Head-30m |
| 221 | Submersible Borewell Pump |
| 222 | Supply installation & Commissioning of submersible borewell pump with SS 304-Casing/Impeller/Shaft & Mechanical seal coupled with a 380-415V, 50Hz 2 Pole, Insulation Class-F, IP 68 Protected Rewindable Electric Motor. Pump efficiency whould not be less than 65%. Pump controller suitable for 1 Pump with LCD screen displays, phase loss protection (incoiming as well as for outgoing), Individual pump overload protection, individual pump under voltage protection, dryrunning protection without installing any float switch, memory function when power off and during recovery, visual and audio alarm for fault prompt, auto manual switch, and pump should operate based on the UGT water level. Panel should come with 1 No. Float switch to work as per the tank water level. Flow Rate Per Pump-13 m3/hr (1W+1S)Head-35m |
| 223 | PRIMARY RO PLANT |
| 224 | Supply ,Testing and Commissioning of Floor Mounted R.O. Plant capable to deliver Output water at TDS < 150 PPM . The Rate Should Include Complete items inclusive of Necessary PVC Storage Tanks, Valves, Membranes, Control Panels, Pipings, Pumps, Strainers, Supports and Other accessories .Backwash once a day. Vendor to consider pre filter reqirement , if any, based on water test at their own cost. Vendor to submit design details, p&ID and plan /section drawings along with membrane calculations for approval. Vendor to submit technical datasheet including membrane details. 50 LPH WITH All Accessories and Pumps, Filters, for Fitting on Floor as per approved OEM drawings |
| 225 | SUPPLY OF DX SPLIT TYPE AIRCONDITIONING SYSTEM Air-Cooled Split Air-conditioners for cooling only of capacity given below suitable for operation on 230 ± 10 % volt, 50 Hz, 1 phase AC supply. The system shall full charge of regrigerant gas and oil. The unit shall be suitable for cordless remote operation and as per specifications. Each air-conditioner shall consist of one outdoor unit and one indoor unit and other accessories as listed below.Air-cooled condensing unit (outdoor) comprising of hermetically sealed Rotary / Scroll type compressor, condenser coil, propeller fan etc. 3 Star Inverter Basic Price for Split AC i/c accessories, fittings, supports, Outdoor Stand, Voltage Stabilizer, ITC etc.1.5 TR, 3 star inverter type |
| 226 | REFRIGERATION PIPING SPLIT UNITS Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping forSplit AC system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given below for Suction and Liquid lines, all accessories as per specifications etc. as required : Copper Pipe for 6.4 mm dia (OD) (Soft drawn) with tube thickness .54 mm with 19 mm thick insulation Copper Pipe for 12.7 mm dia (OD) (Soft drawn) with tube thickness .64 mm with 19 mm thick insulation |
| 227 | CONDENSATE DRAIN PIPING SPLIT UNITS Providing and fixing in position the following pipes cut to required lengths and necessary fittings with insulation. 25 mm dia. PVC pipe |
| 228 | 70 KLD CAPACITY MBBR TYPE SEWAGE TREATMENT PLANT |
| 229 | Supply, Installation, Testing & Commissioning of 1 Nos. 70 KLD Packaged Sewege Treatment plant complete with Bar Screen,all Pumps, Valves, Tanks, Pipings and accessories and necessary associated Electrical Panel and Control and Monitoring system. (The Plant shall be semi automatic with a central Control panel fully pre/site wired and with all power and control cables to all pumps and equipment including all instrumentation, level switch STP Water Tertiary Treatment Plant Supplying, installation, testing & commissioning of Tertiary Plant . The Proposed WTP shall have following components in order to make the water reusable and pathogen free and safe for human and animals.Multi Grade Filter -7.5 Cum/HrActivated Carbon Filter - 7.5 Cum/ HrTreatiary Feed Pump of 7.5 m3/hr , 25 mts headDigital flow meter at the Final outlet Mandatory Inclusons in QuoteIntra Unit PipingsAll Valves, Stariners, Electro mechanical accessories as per SLD / Plan submitted for approval.MCC Panel common for STP & TERTIARY TREATMENT Design, fabrication, assembling, wiring, supply, installation, testing and commissioning of motor control centre fabricated out of 14 gauge CRCA sheet steel. Cable gland plates shall be provided on top as well as at the bottom of the panels. Panels shall be treated with all anticorrosive process before painting as per specifications with 2 coats of red oxide primer and final approved shade of powder coated paint. 2 Nos. earthing terminals shall be provided for 3 phase, 4 wire, 50 Hz supply system. manual selection switches . Also , Supply, installation, testing & commissioning of PLC Panel to make the system Complete |
| 230 | Grand Total STP + TERTIARY |
| 231 | 10 KLD CAPACITY TYPE EFFLUENT TREATMENT PLANT |
| 232 | Nature of Waste Water - Effluent from Labs etcDaily Effluent inflow at peak =10 M³/Day(Outlet of ETP is Discharged to STP Collection Tank)Influent CharacteristicpH - 6.5 - 8.5BOD - 500 mg/liter S. Solids - 250-450 mg/literCOD - 800-900 mg/literOil & Grease - 10 to 50 mg/literEffluent discharge standard after STP Tertiary:pH - 6.5 - 7.5BOD 5 - Less than 10 mg/literS. Solids - Less than 20 mg/literCOD - Less than 50 mg/literOil and Grease - Traces only |
| 233 | Effluent Treatment Plant shall include the supply, installation, testing & commissioning of the following items: |
| 234 | Supply, Installation, Testing & Commissioning of 1 Nos. Eflluent treatment plant 10KLD having lime, alum and polyelectrolyte dozing tanks ,Bar screen,Blower . Outlet of ETP to be connected to STP inlet chamber.This is also include Raw effluent feed pump of 2 setsMCC Control panel with cablesAll piping & valves |
| 235 | CCTV System |
| 236 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable |
| 237 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 238 | Supplying, installation, testing and commissioning of 32 channels CCTV NVR 2 SATAPORT Network Video Recorder with all accessories such as internet connection, 2x4tb Hard Disk etc. complete in all respect to use at site. |
| 239 | Supplying, installation, testing and commissioning of 2MP full HD 1080p dome IP CCTV camera with all accessories complete in all respect to use at site. |
| 240 | Supplying, installation, testing and commissioning of 2MP full HD 1080p bullet IP CCTV camera IP-66 with all accessories complete in all respect to use at site. |
| 241 | Supplying, installation, testing and commissioning of 16 port rack mountable POE switch complete with all accessories . |
| 242 | Supply, Installation, Testing & Commissioning of CAT6 UTP 24 port Patch Panel complete with all accessories complete. |
| 243 | Supply, Installation, Testing & Commissioning of CAT6 patch cord factory crimp cable for connecting RJ 45 including all required like connection etc at site. 1 metre |
| 244 | Supplying, installation, testing and commissioning of 42 inch LED Monitor with VGA and HDMI Ports complete with all accessories . |
| 245 | Central Management Software for Viewing, Multi-DVR management, supporting all cameras at one single screen and maximum Devices management, auto search configuration and status monitoring. |
| 246 | Public address system |
| 247 | Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. |
| 248 | Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. |
| 249 | Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm |
| 250 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 251 | Supplying installation, testing, programming and commissioning of Audio equipment, Reference Dynamic Vocal Microphone, highest audio Performance for stage and studio. |
| 252 | FIRE DETECTION SYSTEM |
| 253 | Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. |
| 254 | Supplying, installation, testing & commissioning of fault isolator complete with base as required. |
| 255 | Supplying, installation, testing & commissioning of addressable fire controll Module complete as required. |
| 256 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 257 | Voice Network System. |
| 258 | Supplying including Fitting & Fixing of RJ45 Computer /Data Socket( Category 5 ( MK or equivalent Schneider/ RR /Legrand) |
| 259 | Patch Cord Cat 6 UTP Gray 1m - Moulded SCHNEIDER/ LEGRAND or equivalent |
| 260 | Patch Cord Cat 6 UTP Gray 2m - Moulded SCHNEIDER/LEGRAND or equivalent make as approved by the Deptt.. |
| 261 | DIGILINKL/ LEGRAND OR equivalent 24 Port 10/100/1000Mbps Layer 2 stackable Switch with 4 Gigabit Combo Ports |
| 262 | TV System |
| 263 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet |
| 264 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mmX75mm) |
| 265 | DATA Network System. |
| 266 | 9U Rack Loaded SCHNEIDER/ LEGRAND or equivalent |
| 267 | Supplying installation, testing, programming and commissioning of video equipment, Mini Coax High−Resolution Cable , COAX CENTER CONDUCTOR: 28 AWG 7/36 tinned copper , |
| 268 | 4K Ultra HD Smart LED TV |
| 269 | MEDICAL GAS PIPELINE SYSTEM |
| 270 | SITC of 8 + 8 cylinder size main Oxygen manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used. |
| 271 | SITC of Fully Automatic Control Panel for Oxygen having constant flow output of over 1000 LPM or more at 55 to 60 psig Pressure as per specification |
| 272 | SITC of 6 + 6 cylinder size Emergency Back-up Oxygen manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used. |
| 273 | SITC of SEMI Automatic Control Panel for Emergency Oxygen Manifold having constant flow output of over 1000 LPM or more at 55 to 60 psig Pressure as per specification |
| 274 | Oxygen Flowmeter with Humidifier as per specification Range: 0 to 15 LPM Range: 0 to 5 LPM BPC Adapter for Ventilator & Anesthesia Workstation Oxygen Kit Conversion for connecting Anaesthesis Machine with Oxygen Gas Outlet |
| 275 | NITROUS OXIDE SYSTEM |
| 276 | SITC of 1 + 1 size main Nitrous Oxide manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used. |
| 277 | SITC of Semi Automatic Control Panel for Nitrous Oxide having constant flow output of over 450 LPM or more at 55 to 60 psig Pressure as per specification |
| 278 | SITC of 1 cylinder size emergency Nitrous Oxide back-up manifold (header bar), complete with middle frame with chain for individual cylinder along with high pressure copper tail pipes, Non Return Valve for every cylinder. All header racks and cylinder tailpipes should be 230 bar rated. Cylinder header racks for oxygen service shall be provided with connections for bull nose cylinder connections. Cylinder racks shall be manufactured from powder coated steel and shall be designed to securely support cylinders of varying diameters. Tailpipes shall have gas specific connections to the manifold header with threaded connections. Manifold header racks shall incorporate hard-seat, polymer-free non-return integral with each cylinder connection point to maintain system in the event of tailpipe fracture and prevent backflow of gas into the high pressure cylinders as per specification. Flexible tail pipes should not be used. |
| 279 | SITC of Preset Nitrous Oxide Pressure Regulator for Emergency Nitrous Oxide Manifold having constant flow output of over 150 LPM or more at 55 to 60 psig Pressure as per specification |
| 280 | Nitrous Oxide Kit Conversion for connecting Anaesthesis Machine with Nitrous Oxide Gas Outlet |
| 281 | SITC of MEDICAL VACUUM SYSTEM AS PER SPECIFICATION |
| 282 | Central Vacuum System Complete with Vacuum Pump, each havig 110 cfm PD with 10 Hp motor, Filter, Interconnecting Pipes, NRV, Auto Switch Gear Assembly, Exhaust Silencer and Line Filter etc. |
| 283 | Vacuum Tank 2000 Liters |
| 284 | Bacterial Filter with Drain Flask- 115 CFM FLOW RATE |
| 285 | Ward Vacuum Unit with Regulator, Collection Jar of 600 ml with Bracket as per specification |
| 286 | Theatre Vacuum Unit mounted on Trolley consisting of Vacuum Regulator with Gauge and 2 nos. of 2000 ml Polycarbonate Jar as per specification |
| 287 | LP Tube |
| 288 | SITC of COMPRESSED AIR SYSTEM AS PER SPECIFICATION |
| 289 | Compressed Air system complete with 2 nos. of Reciprocating Oil free, air cooled type, dust free, Base frame mounted Air Compressors with 10 HP Motors with Air filter 2 sets (Pre, Post and Activated Carbon) |
| 290 | Air receiver shall be of 1000 litres water capacity designed considering maximim working pressure of 10 bar(g). |
| 291 | Medical Breathing Air Dryer |
| 292 | Pressure Reducing Station for 4 Bar |
| 293 | SITC of Common Electrical Power Distribution Panel for Compressed Air System & Vacuum System as per specification complete with plant room wiring. |
| 294 | SITC of Distribution Copper Pipe as per EN 13348 - Lloyds Certified as per specification |
| 295 | 35 mm OD x 1.2 mm thick |
| 296 | 28 mm OD x 1.2 mm thick |
| 297 | 22 mm OD x 0.9 mm thick |
| 298 | 15 mm OD x 0.9 mm thick |
| 299 | 12 mm OD x 0.9 mm thick |
| 300 | SITC of Medical Gas Outlets / Terminal Units for mounting on Wall, Bed Head Panel & Ceiling Pendant as per specification |
| 301 | Front Loading Oxygen Outlets with probe |
| 302 | Front Loading N2O Outlets with probe |
| 303 | Front Loading Medical Air - 4 Bar Outlets with probe |
| 304 | Front Loading Vacuum Outlets with probe |
| 305 | SITC of Medical Gas Digital Area Alarm System as per specification |
| 306 | 4 - Gas (O2,N2O, Med Air-4 Bar & Vacuum) |
| 307 | 3 - Gas (O2, Air & Vacuum) |
| 308 | Area Valve Service Unit with Valve & Gauge as per specification |
| 309 | 4 Gas Service ( 35 x 28 x 28 x 22 mm) |
| 310 | SITC of Lockable Floor Isolation Valve with End Fittings as per specification |
| 311 | 12 mm |
| 312 | 15 mm |
| 313 | 22 mm |
| 314 | 28 mm |
| 315 | SITC of Medical Gas Tubing color coded throughout their length for Oxygen, Medical Air & Vacuum |
| 316 | FIRE RISER SYSTEM & INTERNAL HYDRANT SYSTEM |
| 317 | Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete Note : The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable code & standard before applying paint etc. complete 150 mm (Wet Risers for Hydrant) 80 mm (For Internal Landing valve Connection) 50 mm (Drain Down Comer) 25 mm (For Internal Hose Reel Drum Conection) |
| 318 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 150 mm (For Hydrant) 80 mm (For Internal Landing Valve) |
| 319 | Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Size : 150 mm |
| 320 | Supplying and fixing single headed internal hydrant valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required 63mm Single headed Hydrant Valve or Internal Landing Valve |
| 321 | Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required 63 mm RRL Hose 15mtr.length. |
| 322 | Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as shown in the drawing (or as approved by Architect) to house the hydrant valve, 15 mtr.x2 nos. hose & hose reel. The hose cabinet size is 1500 x 900 mm x 450 mm Hose Reel Drum having 40 mtr. Hose Reel Length |
| 323 | Providing, fixing and testing forged brass 25 mm dia screwed inlet single acting air release valve with 25 mm dia Ball Valve on inlet side and pressure gauge with 15 mm isolating cock / Valve. 25mm Air release valve as per IS:14845 ISI Marked |
| 324 | Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required GM Branch Pipe with NOZZLE |
| 325 | Supplying and fixing orifice plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. Orifice Plate |
| 326 | 25 mm nominal bore Ball Valve (for Internal HRD & ARV) |
| 327 | EXTERNAL HYDRANT |
| 328 | Excavations for pipelines in trench and pit in open areas where disposal or surplus earth is done along the alignment, including trimming and dressing sides, leveling of beds of trenches to correct grades, cutting joint holes, refilling consolidation and dewatering of refilling in 15 cm layers & restoration & unmettalled or unpaved surface to it's original condition. The rate including the cost of necessary timbering dewatering of drain water, diversion of traffic, night signals, fixing caution boars, watching fencing etc. Upto 1.5m depth in all classes of soil |
| 329 | ‘C’ class MS Pipe as per IS1239 for underground/over ground pipes with welded / flanged connection with saddles, supports (all with screwed/welded joints) as required including pipe of shorter lengths, tapering connecting pieces, short or long bends, specials like sockets, union nuts, elbows, reducers, plugs, Tees etc. Complete to make the system operative as required by LFA / TAC authorities the pipes will have to be laid and fixed in trenches. The work includes excavation in all types of soils and back filling, dewatering, etc., making holes in brick or RCC walls, slabs/ roofs and making good the damages by bringing to the original condition to the satisfaction of the Architect and painting two coats of approved shade(Post office red)of enamel paint over a coat of approved primer for overheads pipes and providing and fixing pyp kote (corrosion protection tape) including supply and application of pipe coating and spiral Wrapping for underground piping (wrapping should have overlap of 15 to 20 mm) etc. Complete as per ASTM standards/IS: 10221 for corrosion protection of pipes for the underground installation.Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure & as per latest applicable codes & standard before applying paint or pipe coating or wrapping etc. complete. OVER GROUND 150 mm dia. 100 mm dia. 80 mm dia. UNDER GROUND 150 mm dia. |
| 330 | Providing and fixing hydrant stand posts of 80 mm dia. With flanges and accessories and supply, fixing single headed 63 mm dia G.M. Hydrant Valve in the courtyard IS:5290 Including 2 coats of approved enamel paint (red) over a coat of primer, complete with 2.1/2” ‘Morris’ pattern instaneous couplings, etc. complete. Yard Hydrant : 63 mm |
| 331 | Providing & fixing 63mm dia RRL hose pipe as per IS 636 TYPE A TAC/ LFA approved of 15 mtr. standard length of approved pattern and size including gun metal male and female Coupling duly bound with copper wire etc. complete 63 mm RRL Hose 15mtr.length. |
| 332 | Supplying and fixing 4 way Fire Brigade service inlet of size 150 mm dia. with 4 No. 63mm (2.1/2\\") size GM male outlets ( bronze male coupling) including metallic cover of mild steel and glass front, indicator plates,150mm BFV, etc. complete 4 Way Fire Brigade service inlet |
| 333 | SITC of fire brigade draw out connection with 100 mm MS suction pipe & 100 mm dia foot valve. The scope shall also include required valves, piping, M.S cabinet as required 2 Way Fire Brigade draw out connection |
| 334 | Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominalsize), inside plastering 12 mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : 19.7.1.1 With common burnt clay F.P.S. (non modular)bricks of class designation 7.5 |
| 335 | Supply and installation, testing and commissioning of CI Butterfly Valves ( heavy ) conforming to BS 5155 ,PN1.0 tested to 1.5 times working pressure with necessary companion flanges, bolts, nuts, gasket packing, support and any other spares, including indicator for open and shut position as per fire practice etc complete. 150 NB 100 NB 80 NB |
| 336 | Non-Return Valve conforming to IS 5312 (swing type) or to API 594/598 (dual plate check type) with CI body & brass trim part, PN 1.0 having necessary companion flanges, CS hardwares. Gaskets, arrow indicating direction of flow, etc. complete. It shall be ISI Marked and approved make 150 NB 100 NB |
| 337 | Supplying & fixing 63 mm dia Gun Metal Short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required |
| 338 | Providing and laying non-pressure NP2 class (light duty) R.C.C. Pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : Hume Pipe : 300 NB |
| 339 | FIRE PUMPS & RELATED ACCESSORIES |
| 340 | Supplying, installation, testing and commissioning of Electric driven Main Fire Pump suitable for automatic operation and consisting of following, complete in all respects, as required Horizontal type, multistage, centrifugal, split casing pump with bronze impeller stainless steel shaft, mechanical seal at a flow of 2280 lpm at 70 m head against all losses complete. conforming to IS 1520.Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS-325.M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered with anti vibration pads. Pump - Motor : Discharge : 2850 LPM, Head : 70 mtr HYDRANT PUMPS+1 STAND BY |
| 341 | Supplying, installation, testing and commissioning of diesel engine driven stand-by fire pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Diesel Driven Pump) Horizontal type, multistage, centrifugal pump of cast of iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS 1520.Suitable HP, 1500 RPM water cooled with radiator, diesel engine conforming to relevant IS standard complete with auto starting mechanism, 12 /24 volts electric starting equipment, diesel tank, exhaust pipe extended upto 10 m outside pump house duly insulated with 50 mm thick glass wool with 1.0 mm thick aluminium sheet cladding, residential silencer, instruments and protection as per standard specification, stop solenoid for auto stop in the event of fault with audio indications, painted with post office red colour etc. as required.M.S fabricated, common base plate, coupling, coupling guard, foundation bolts etc. as required.Suitable cement concrete foundation duly plastered and with anti vibration pads. Pump - Motor : Discharge : 2850 LPM, Head : 70mtr (FOR STAND -BY PUMP) |
| 342 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. Pump - Motor: Discharge : 180 LPM, Head : 70 mtr. (FOR JOCKEY PUMP) |
| 343 | EARTHING |
| 344 | Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 345 | Supply, laying, connection and testing bare earthing conductor for inter-connecting the earthing stations and various equipment in built up trenches, walls/ceiling, buried in ground generally as specified and shown on the drawing complete Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) |
| 346 | CABLE END TERMINATION |
| 347 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 3½ X 95 sq. mm (45mm) |
| 348 | Supplying, installation testing and commissioning of the following Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as Note: The piping installation has to be put to hydraulic test to1.5 times the working pressure (for minimum 2 hrs.) before applying paint or pipe coating and wrapping etc. Complete Size : 250mm ( 6.3 mm thk IS 3589) Size : 200mm ( 6.3 mm thk IS 3589) Size : 150mm Size : 100 mm Size : 50 mm Size : 40 mm Size : 25 mm |
| 349 | Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange. Size : 200 mm |
| 350 | Supplying, fixing, testing & commissioning of double flanged Sluice Valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required Size : 200 mm |
| 351 | Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required Size : 200 mm Size : 150 mm Size : 100 mm Size : 50 mm Size : 40 mm |
| 352 | Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required Size : 200 mm Size : 150 mm Size : 40 mm |
| 353 | Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required. Pressure Switch |
| 354 | Supplying and fixing air vessel made of 250 mm dia, 8 mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade. |
| 355 | FIRE RISER SYSTEM & INTERNAL HYDRANT SYSTEM |
| 356 | Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. Internal Hose Cabinet |
| 357 | Providing and fixing TAC approved fire hose cabinet to house fire hydrant & hose, including all other related accerrories fabricated from M.S. sheet (16 Gauge) of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thick glass. Cabinet shall be powder coated & painted with post office red colour of size as mentioned in drawing (or as approved by the Architect) to house 15 mtr.x2 nos. hoses. The hose box size is 750 mm x 600 mm x 300 mm Hose Cabinet for External yard Hydrant |
| 358 | FIRE PUMPS & RELATED ACCESSORIES |
| 359 | MCC for Fire Pumps : Design, manufacture, supply ,installation, testing and commissioning of following Fire panel suitable for 415V, 3 phase, 4 wire, 50 hz power distribution system. The panel should be indoor, free standing, floor mounting, sheet metal clad, Cubicle, dead front, dust and vermin proof, compartmentalized design fabricated out of 14 SWG sheet steel complete with Cu busbars, a separate earth bus bar to be provided through out the length of the panel. The incoming and outgoing feeders shall be accommodated in a modular multitier arrangement, adequate size cable alley, painting, earthing numbering, damper plate etc. as required as per specifications and drawings and as per local Fire Authority requirement FIRE MCC PANEL |
| 360 | Supply, installation, testing and commissioning of 25 x 6 mm GI Equipotential bar of 500 mm length with suitable. junction box to connect earthing conductor from building earthing to the equipment. (With six knock outs for connecting the equipment earthing |
| 361 | CABLE |
| 362 | Supply, laying testing and commissioning of L.T. XLPE armoured / unarmoured cable confirming to IS : 7098 Part - II as per the description given below: (Note: Qty may vary +/- 15% as per actual work at site) 3.5 C x 95 Sq. MM. Al. XLPE ARM Cable (FIRE PANEL To Hydrant & Standby Pumps) 3.5 C x 2.5 Sq. MM. Cu. PVC Armored Cable (JOCKEY PUMP) 5 C x 2.5 Sq. MM. Cu. PVC Armored Cable |
| 363 | Installation of 3.5 C x 2.5 Sq. MM. Cu. PVC Armored Cable (JOCKEY PUMP) 5 C x 2.5 Sq. MM. Cu. PVC Armoured Cable |
| 364 | Providing and fixing Power wiring with 2 core x 1.5 sq.mm. PVC armoured copper cable for wiring pressure switches, etc. Including all required material and labour, terminations, etc. Complete. |
| 365 | Providing, installing testing & commissioning of Foot valve Size : 100 mm |
| 366 | 100 mm dial Pressure gauge with Syphon tubing, isolation valve & mounting accessories complete Range: 0 - 10 kg/sq.cm. Pressure Gauge : 0 - 10 kg/sq.cm. |
| 367 | Supply, installation, testing & commissioning of Rubber Bellows on discharge side of pump conforming to EJMA with all hardwares, companion flanges & gaskets, etc. Size : 200 mm Size : 150 mm Size : 50 mm Size : 40 mm |
| 368 | SITC of electronic type water level indicator with LED panel, with probe & all control wiring to operate the system automatic/manual & shall prevent the pump from dry running |
| 369 | Fire Man Axe with heavy insulated rubber handle tested to 20,000 volts as per IS:929 complete Fire Man Axe Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 17, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 17, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender