Tender For Tender For Providing Rolling Shutter, Prepainted Sheet Roofing & Painting Work, electrical installation Wiring In Control Room Building & Providing And Fixing Of Stanvac 1311 Insulkote Class-A High Build-High Breakdown Voltage Epoxy Insula
Tender Overview
Project Description
Tender for Tender For Providing Rolling Shutter, Prepainted Sheet Roofing & Painting Work, electrical installation Wiring In Control Room Building & Providing And Fixing Of Stanvac 1311 Insulkote Class-A High Build-High Breakdown Voltage Epoxy Insulation Coating In Control Room Building At 33/11 Kv Sub-Station Namhol Under Electrical Division Hpsebl Bilaspur
BOQ
| Sl. No. | Item Description |
| 1 | Providing Rolling shutter, prepainted sheet roofing & painting work at 33/11 KV Sub-Station Namol under Electrical Division HPSEBL Bilaspur. |
| 2 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar. |
| 3 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand) : 3 graded stone aggregate 20 mm nominal size. |
| 4 | Steel reinforcement for R.C.C. work including straightening, cutting bending, placing in position and binding all complete above plinth level. Mild steel and Medium Tensile steel bars. |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for all heights ;- Lintels, beams, plinth beams, girders, bressumers and cantilevers . |
| 6 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 7 | Providing and fixing M.S. BP Sheet 1.66mm to 2mm thick in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-charge (Base members of steel work shall be measured & paid separtely). |
| 8 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 9 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 1518 microns using self drilling/ self tapping screws complete Ridges plain (500 - 600mm). |
| 10 | Providing and fixing M.S. BP Sheet 1.66mm to 2mm thick in eaves board/facia/soffits/ceiling including cutting, fixing and welding to steel roof members and applying a coat of red lead primer complete as per the instruction of Engineer-in-charge (Base members of steel work shall be measured & paid separtely). |
| 11 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work. |
| 12 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454- part 1 and M.S. top cover of required thickness for rolling shutters. 80x0.90 mm M.S. laths with 0.90 mm thick top cover. |
| 13 | Repair to plaster in patches of 2.50 sqm and under and 10 to 15 mm thick i/c cutting the patch in square shape and replastering the surface of the wall including disposal of rubbish to the dumping ground with in a lead of 20 m and with CM 1:4 (1 CEMENT: 4 SAND) |
| 14 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : Water thinnable cement primer. |
| 15 | Distempering with 1st quality acrylic distember (Ready mix) having VOC content less than 50 grams/ litre of approved brand and manufacture to give an even shade : Old work (one or more coats). |
| 16 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two Coats. |
| 17 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : One or more coats on old work. |
| 18 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty : Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/sqm) |
| 19 | Lettering with black Japan paint of approved brand and manufacture. |
| 20 | Providing EI wiring in Control Room Building of 33/11KV S/Stn Namhol under Electrical Sub-Division HPSEBL Namhol |
| 21 | Wiring for light point/exhast fan point/ call bell point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in surface / heavy class PVC conduit having wall thicness minimum 2mm, with modular swithch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Make ; - ANCHOR, KEI, PLAZA its equivalant. |
| 22 | Group C |
| 23 | Wiring for twin control light point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable in heavy class PVC conduit having wall thicness minimum 2mm, 2 way modular swithch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc as required. Make ; - ANCHOR, KEI, PLAZA its equivalant. |
| 24 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 3 pin 5*6amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. Make ; - ANCHOR ROMA CLASIC, ANCHOR by PANASONIC or its equivalant. |
| 25 | Supplying and fixing suitable size GI box with modular plate and cover in FRLS on surface or in recess, including proving and fixing 6 pin 5*6amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch, connection etc. as required. Make ; - ANCHOR ROMA CLASIC, ANCHOR by PANASONIC or its equivalant. |
| 26 | Supplying and fixing following modular switch/socket on the exising modular plate 7 switch box including connection but excluding modular plate etc. as required. Make: - ANCHOR ROMA CLASIC, L&T. or its equivalent. |
| 27 | 5Amp modular switch |
| 28 | 5 amp modular socket |
| 29 | Providing and installation of stationary storage type Electrical water heater (Geyser) of various sizes by mean of expension bolts with nuts and washer, including embedding of expension bolts in the wall making good the damages, electrical connection , testing etc. complete as required: Make USHA (Model Mist 25 ltr), Bajaj, Record or its equivalent as approved Engineer in charge. |
| 30 | Wiring for circuit/ sub main wiring along with earth wire with the following size of FRLS PVC insulated copper conductor, single core cable in surface/recessed heavy class PVC condute having wall thickness 2.0mm as required ANCHOR, KEI, PLAZA or its equivalent. |
| 31 | 2x1.5sq.mm +1x1.5sq.mm earth wire |
| 32 | 2x4 sq.mm +1x4 sq.mm earth wire |
| 33 | 4x4 sq.mm +2x4 sq.mm earth wire |
| 34 | 2 x 10 Sq. mm. + 1x 6 Sq. mm earth wire |
| 35 | Provinding, installation, testing and commissioning of BLDC ceiling fan (5 star rating), including wiring the down rods of standard length (up to 30CM) with 16/0.20mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required |
| 36 | Ceiling Fan 1200mm sweep |
| 37 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make: - Anchor ( Roma classic), L&T(Entice). Legrand(Myrius) or its equivalent as approved by Engineer-in-charge. |
| 38 | Provinding, installation, exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: Make: - USHA, BAJAJ, CROMPTON or its equivalent as approved by Enginner-in-charge. |
| 39 | Exhaust Fan, Linght duty, (Domestic)300mm sweep |
| 40 | Provinding and fixing of IP20LED fixture of 18 watt +/- 1W LED Surface Mounted Downlighter Squre/ Round Shape with minimum system lumen efficency of 100Im/W with Polycarbonate housing, pressure die cast heat sink and P.F. > 0.95 with THD < 10%, CRI 80. The LED shall be tested with LM 80-08 standard with useful life of 50000 Hrs. at L70. The LEDs used in the luminaire shall have CCT of ANSI Bin 5700K with CRI of minimum 80. The Input voltage range shall be 150V to 270V, 50/60 HZ complete with all accessories, including connections, testing and commissioning etc. as required complete in all respects. |
| 41 | Provinding installetion, tesiting and commissioning of Glazed LED 10Watt Batten 600mm long ( Mirror Light) High quality design aluminum extruded decorative end caps asper best satisfaction of Engineer-in-charge. Make: - Wpro Cat No. L20-111-XXX-65NE3), Jaquar, Wipro, Philips or equivalent make with five ear warranty or its equivalent or as approved by Engineer-incharge. |
| 42 | Supplying and fixing LED street light 25 Watts,LED street light made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP OPENING seperate driver compartment with IP65 protection and impact resistance of IK07, Havells make having Ordering code LHETBXU7PA6S025 complete with connections, testing, commisioning etc as required. Havells, Philips, K-lite. |
| 43 | Supplying and fixing wireless Ding Dong bell suitable for single phase,230V complete as required. Make:- Anchor or its equivalent as approved by Engineer-in-charge. |
| 44 | Supplying and fixing batten/angle holder including connection etc. as required. Make: - Anchor or its equivalent as approved by Engineer-in-charge. |
| 45 | Supplying and fixing 6 amps to 32 amps rating, 240/415 volts, 10kA, :C: curve, miniature circuit breaker suitable for inductive load of following poles in the miniature circuit breaker suitable for inductive load of following poles in the existibg MCB DB complete with connections, testing and commissioning etc. as required. Make: - ANCHOR, L&T, LEGRAND or its equivalent as approved by Engineer-in-charge. Single pole. |
| 46 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: - ANCHOR, L&T, LEGRAND or its equivalent as approved by Engineer-in-charge. |
| 47 | 63 amp. |
| 48 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, power painted including earthing etc. as required. ( but without MCB/RCCB/Isolator) ANCHOR UNO, L&T, LEGRAND or its equivalent as approved by Engineer-in-charge. |
| 49 | 12 way, Double door. |
| 50 | providing and fixing of stanvac 1311 insulkote Class-A High Build-High Breakdown voltage epoxy insulation coating in control room building of 33/11KV S/Stn Namhol under Electrical Sub-Division HPSEBL Namhol. |
| 51 | Providing and fixing of stanvac 1311 insulkote Class-A High Build-High Breakdown voltage epoxy insulation coating smooth glossy finish in all respect , in place of ground matting in control room building of 33/11KV S/Stn Namhol. Dielectric Strength 34.1 KV BDH. Thicknesss : 2.5 mm Qty. : 30 Sq. M. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
TodayBid Opening Date
Technical bids will be opened and evaluated.
TodayTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender