Tender For Repair Of Plaster/Rcc At All Heights Of Departments In Zone F At Iit Roorkee
Tender Value
Ref. Documents
Estimated cost
Bid Submission
10 Aug 2026
17 days left
EMD
20000
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair Of Plaster/Rcc At All Heights Of Departments In Zone F At Iit Roorkee
BOQ
| Sl. No. | Item Description |
| 1 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement: 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregae 20 mm nominal size derived from natural sources). |
| 2 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 3 | Suspended floors, roofs, landings, balconies and access platform |
| 4 | Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 5 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 6 | Weather shade, Chajjas, corbels etc., including edges |
| 7 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level. |
| 8 | Thermo-Mechanically Treated bars of grade Fe-500D or more |
| 9 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : |
| 10 | Cement mortar 1 :4 (1 cement : 4 coarse sand) |
| 11 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor Vlevel. |
| 12 | Cement mortar 1 :4 (1 cement :4 coarse sand) |
| 13 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 14 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 15 | Hot finished welded type tubes |
| 16 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. |
| 17 | Galvanised M.S. Wire gauze with 0.63 mm dia wire and 1.4 mm aperture on both sides |
| 18 | Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides |
| 19 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with |
| 20 | 4.0 mm thick glass panes |
| 21 | 5.5 mm thick glass panes |
| 22 | Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design : |
| 23 | In 75x75 mm deep chase |
| 24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. |
| 25 | 75 mm diameter |
| 26 | 110 mm diameter |
| 27 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion |
| 28 | Coupler |
| 29 | 110mm |
| 30 | Single pushfit Coupler : |
| 31 | 110mm |
| 32 | Single tee with door |
| 33 | 75x75x75 mm |
| 34 | 110x110x110 mm |
| 35 | Single tee without door |
| 36 | 75x75x75 mm |
| 37 | 110x110x110 mm |
| 38 | Bend 87.5° |
| 39 | 75 mm bend |
| 40 | 110 mm bend |
| 41 | Shoe (Plain) |
| 42 | 75 mm Shoe |
| 43 | 110 mm Shoe |
| 44 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers |
| 45 | Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. |
| 46 | Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand): |
| 47 | Flush / Ruled/ Struck or weathered pointing |
| 48 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. |
| 49 | With cement mortar 1:4 (1cement: 4 coarse sand) |
| 50 | Renewing glass panes, with putty and nails wherever necessary including racking out the old putty: |
| 51 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/Sqm) |
| 52 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/Sqm) |
| 53 | Renewing glass panes, with wooden fillets wherever necessary |
| 54 | Float glass panes of nominal thickness 4 mm (weight not less than 10kg/Sqm) |
| 55 | Float glass panes of nominal thickness 5 mm (weight not less than 12.5kg/Sqm) |
| 56 | Refixing old glass panes with putty and nails. |
| 57 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge |
| 58 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. |
| 59 | In cement mortar |
| 60 | Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured): |
| 61 | From brick work in cement mortar |
| 62 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead. |
| 63 | Dismantling steel work manually/ by mechanical means in built up sections without dismembering and stacking within 50 metres lead as per direction of Engineer-in-charge |
| 64 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : |
| 65 | 75 to 80 mm dia pipe |
| 66 | 100 mm dia pipe |
| 67 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 68 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. |
| 69 | Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of EngineerIn-charge complete in all respect. |
| 70 | SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer |
| 71 | Water proofing treatment of RCC sunshade with Zycosil/equivalent water proofing Solution (1 litre of Zycosil/equivalent & 20 litres of water stirred f irst & 2 litres of Zycoprime/equivalent added and stirred (total 23 litres)) till it meets the saturation level and testing as per RILEM or by water drops test in which water drops do not absorb but drops remain or rolls. |
| 72 | Providing, mixing and applying 12 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. |
| 73 | Providing, mixing and applying 15 mm thick ready mix cement plaster of approved make as per specifications and directions of Engineer-in-charge. |
| 74 | Brick work with old bricks (supplied free of cost at our stores) in superstructure above plinth level up to floor V level in cement mortar 1:6 (1 cement : 6 coarse sand) |
| 75 | Half brick masonry with old bricks (supplied free of cost at our central stores) in superstructure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand) masaonry with old bricks (1:4 cm) etc. complete in all respects as per directions of EIC |
| 76 | For Calculation purpose Only |
| 77 | Sub Total (A) Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 10, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender