Power Government Departments Closing in 10 days TDR #56504805

Tender For Execution Of Deposit Works, Including The Supply, Erection, Installation, Testing, And Commissioning Of Materials/Equipment For The Construction Of 33/11 Kv Sub-Stations, 33 Kv & 11 Kv Overhead Line, Laying Of 33 Kv And 11 Kv Underground X

Issued by Government Departments · Jaipur, Rajasthan
Tender Value
19.44 Crore
Estimated cost
Bid Submission
31 Jul 2026
10 days left
EMD
38.88 Lakhs
Bank guarantee accepted
Document Fee
2950
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jaipur → Rajasthan
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Execution Of Deposit Works, Including The Supply, Erection, Installation, Testing, And Commissioning Of Materials/Equipment For The Construction Of 33/11 Kv Sub-Stations, 33 Kv & 11 Kv Overhead Line, Laying Of 33 Kv And 11 Kv Underground Xlpe Cable, Construction Of 33 Kv Bay, 11 Kv Bay And Shifting Of 33 Kv & 11 Kv Line, Metering Under Baran Circle On Turnkey Basis Against Tw/Tn-627.

BOQ

Name of Work:- Execution of deposit works, including the Supply, Erection, Installation, Testing, and Commissioning of materials/equipment for the construction of 33/11 KV sub-stations, 33 KV & 11 KV overhead Line, laying of 33 KV and 11 KV underground XLPE Cable, construction of 33 KV Bay, 11 KV Bay and shifting of 33 KV & 11 KV line, Metering under Baran circle on turnkey basis against TW/TN-627.
Sl. No. Item Description
1The rate of supply of item is inclusive of Freight and insurance at site including loading & unloading.
2PCC Poles 9 mtr long 200 Kg
3PCC Poles 9 mtr long 400 Kg
433 KV D/C Lattice Structure (42' ungalvanised with 3 Nos. 33 KV cross arm (Channel))
5ACSR DOG Conductor
6ACSR Rabbit Conductor
733 KV 3C X 300 Sqmm. HT XLPE Cable
811 KV 3C X 185 Sqmm HT XLPE Cable
933 KV 3C X 300 Sqmm. Outdoor CABLE JOINTING KITS
1011 KV 3C X 185 Sqmm Outdoor CABLE JOINTING KITS
1133/11 KV GSS Structure Set Complete (Rural)
1233 KV Line DP Set
1311 KV Line DP Set
1433 KV 630 Amps. Isolators with PI (W/o EB)
1533 KV 630 Amps. Isolators with PI (With EB)
1611 KV 400 Amps. Isolators with PI (Without EB)
1733 KV Horn Gap Fuse Set with Post Insulator
1811 KV Horn Gap Fuse Set with Post Insulator
1912 KV Outdoor VCB Kiosks
2036 KV Outdoor VCB Kiosks
2133 KV Disc Insulator 45 KN B&S Type
2233 KV Disc Insulator H/W Set for 45 KN B&S Type
2311 KV Disc Insulator 45 KN T&C Type
2411 KV Disc Insulator H/W Set for 45 KN T&C Type
2533 KV Pin Insulator
2633 KV Galvanised MS Forged Pin
2711 KV Pin Insulator
2811 KV Galvanised MS Forged Pin
29G.S. Stay Sets 20X2400 MM
3033 KV Stay Insulator
31G.S. Stay Sets 16X1800 MM
32G.S. Stay Wire 7/10 SWG
3311 KV Stay Insulator
34Stay Set Clamps suitable for 9mtr. Long PCC Poles
351.8 Mtr. Channel Bracket with clamp
361.4 Mtr. Channel Bracket with clamp
37G.S. Earthwire 8 SWG
38G.S. Earthwire 6 SWG
39MS Rod Type Earthing Set with wire and clamp
40PG Clamp for ACSR DOG Conductor
41M.S. Channel 100X50X6 MM
4211 KV CT-PT Set 200/5 Amps.
43Danger Plates
445 MVA 33/ 11 KV Power Transformer
45G.S. Stay Wire 7/8 SWG
46Control Cable 12C X 2.5 Sqmm
47LT PVC Insulated PVC Sheathed Cable (Armoured) 2C X 4 Sqmm.
48M. S. Flat 50 X 6 mm
4930 KV Station type surge arrestor
509 KV Station type surge arrestor (LA)
5111/0.4 KV DISTRIBUTION TRANSFORMER 25 KVA THREE PHASE WITH M&P BOX (AL WOUND)
52PG Clamp for ACSR Rabbit
5333 KV S/C Lattice Structure (36' ungalvanised with 1 No. 33 KV cross arm (Channel))
54HTTVM With Voltage Profile Features
55LT DISTRIBUTION KIOSKS 200 AMP. SUITABLE FOR 63/100 KVA DISTRIBUTION TRANSFORMERS
56LT AERIAL BUNCHED CABLE (PVC SHEATTHED) 1C X 25 + 25 SQ. MM. (BARE MESSENGER)
57Conducting route survey as per approved route map and pegging of route with tee off point section point & double pole locations.
58Grass cutting and surface dressing including removal of unwanted/rubbish plants with roots from open ground/yard and other Nigam premises with stacking of grass/plants at desired place near the ground.
59Levelling of ground
60Levelling of ground above 30 cm. to 90 CM. depth with tractor and T&P required as per condition of ground including removal of rubbish plants from ground & marking of boundary with lime powder. (Including all lead & lifting)
61Trimming of tree branches/plants manually/ by machine and preparing route approchases for proposed line.
62Excavation of pit in ordinary rock which does not require blasting/murrad (in Jodhpur discom) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
63(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
649 Mtr/ 1.2mx0.6mx1.50 m deep
65(B) Lattice Tower /Size of pit
6612.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
67(C) Stay set/Depth of pit
688'x 3/4\\" -0.75x0.5x1.6 m
696'x 5/8\\" -0.75x0.5x1.35 m
70Excavation of pit in Hard rock (Where blasting/drilling is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
71(A) Height of poles/R.S.Joist/M.S. Rail /Size of pit
729 Mtr/ 1.2mx0.6mx1.50 m deep
73(B) Lattice Tower /Size of pit
7412.8/12.6 Mtr/ 1.5mx1.5m x2.10 m deep
75(C) Stay set/Depth of pit
768'x 3/4\\" -0.75x0.5x1.6 m
776'x 5/8\\" -0.75x0.5x1.35 m
78Earth work excavation and foundation of platfrom of transformers and brakers including dressing of sides and ramming of bottoms. Liftup to 1.5 Meter including taking out the excavated soil and depositing and refilling of jhiri, watering and ramming and disposal of surplus excavated soil as directed with in a lead of 50 Meter.
79Hard soil mixed with boulders
80Providing and laying cement concrete including compaction etc, complete using stone aggregate 40 mm nominal size (hand broken) in foundation plinth excluding the cost of shuttering using 1 cement:5 sand:10 aggregate mix.
81The rates are all lead of cement, lime, ballast, sand, surkhi and grit etc. at site of work.
82For all concrete work coarse sand shall be used no extra will be paid.
83Concrete mix prepared by power driven mechanical mixer shall be used.
84Under exceptional coditions, where mechanical mixer and vibrator are not used (with the approval of Engineer Incharge reduced by 3% for mechanical mixer and 2% for Vibrator
85Thickness of the cement concrete should not exceeed 100 mm.
86Plaster on new surface on walls in cement, sand mortar 1:6 including racking of joint etc. complete fine finish 25 mm thick.
87The rates for complete work including racking of joints, curing, grinding, mixing and finishing T&P and scaffolding material and cost of material with all lead and lift.
88The rates cover protection of all place and things, requiring protection and cleaing such places and thing of all droppings and splashes of mortar etc.
89Cement concrete flooring grade 1:2:4 (1-cement :2- coarse sand :4-graded stone aggregate) rounding off edges etc. but excluding cost of nosing of steps etc. complete.
9025 mm thick with 12.5 mm thick nominal size aggregate.
9175 mm thick with 20 mm thick nominal size aggregate.
92The rates for all items inculde all form of work, laying, curing and finishing etc. The rates are for complete work at site, inclusive of all leads.
93The rates cover the preparation and cleaing of all places
94Masonry for foundation and plinth
95Randon Rubble stone masonry for foundation and plinth in cement sand mortar 1:6 (1 Cement : 6 Sand) including labour charges.
96Erection of all type of steel supports in the excavated pit in alignment after checking the same with plumb line including fixing of cross arms and top hamper before erecting the supports. The support should be grouted and muffed in cement concrete of ratio 1:3:6 as per item No. 5.7 the remaining portion of the pit will be back filled with soil. The cost muffing and grouting will be paid extra.
97Lattice Structure
98Erection &assembly of 2 Pole structures of steel supports or PCC poles in excavated pit in alignment after checking the same with plumb line. Including fixing of top bracing of M.S.Channels with pilot plates and clamps. The support is to be back filled with soil with proper ramming.
99PCC Poles 9 Mtr. Long(400 Kg.)/11Mtr.long
100PCC Poles 9 Mtr. Long(200 Kg.)
101Erection & fixing of G.I.Stay sets with anchor plates in excavated pit in required position and back filling with soil with proper ramming. The work includes fixing of stay clamps. Stay insulator with stay wire at both ends with proper tension. Size of stay set/stay wire
1028\\"x3/4\\" with 7/8 SWG stay wire
1036\\"x5/8\\" with 7/10 SWG stay wire
104Providing and laying of cement concrete in ratio 1:3:6 using 43 grade cement, river sand and 12 mm to 20 mm graded blast crusher broken in pit/foundation according to the size/type of supports/stay set including compaction/curing for 21 days in steel plates shuttering /farmer base.
105Supplying and laying of randum rubble stone boulder having weight not less than 20 kgs.
106Fixing of all type of fabricated material on erected supports with nut & bolts as per approved design & drawing of sub-station.
107Fixing and assembly of disc. point channel pair with pilot plates & clamps on erected double pole structure as per design.
10833 KV line
10911 KV line
110Fixing of 11kv B&S/T&C type disc insulator for 33kv lines (each unit consiting of 3 Nos. disc. & 1set of H/W) on terminal point including fixing of hardware and strips.
111Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 1 Nos. disc & 1 set of H/W) on terminal point including fixing of hardware and strips.
112Fixing of 11kv B&S/T&C type disc insulator of 11kv lines (each unit consiting of 2 nos. disc. & 1set of H/W) on terminal point including fixing of hardware and strips.
113Fixing of 33kv pin insulator with pins.
114Fixing of 11 KV pin insulator with pins.
115Fixing of danger plates on supports/structure
116Fixing of PG clamp of Dog /Racoon Conductor
117Assembly, Installation & commissioning of gang operated isolating switch on erected structure with setting for accurate operation including fixing of allied accessories completein all respect with post insulator and jumpering on both ends for connection with the system.
118(A) G.O. switch. with earthing blade.
11933kv G.O.switch
120(B) G.O. switch. without earthing blade.
12133kv G.O.switch
12211kv G.O.switch
123Assembly and installation of Horn Gap fuse set (set of 3 nos) on erected structure as per design, complete in all respect with post insulator including jumpering on both ends for connection with the system.
12433kv Horn Gap fuse set.
12511kv Horn Gap fuse set.
126Installation testing as per Nigams norm & commissioning of 11/0.4KV distribution transformer on erected supports including fixing of base channels as per requirment jumpering on HV & LV side, crimping of lugs/ clamping earth connections of body and neutral of transformer with wire /strip (as already provided with earthing ) complete in all respect.
12725 and 40 KVA
128Laying, jointing, stringing, tensioning and clamping of conductor with proper sag as directed, using bolted type hardware including binding on pin insulators, jumpering on section points with binding wire / P.G.clamps. Aluminium jointing sleeves will be used for jointing the conductor. The line must stand at proper voltage on charging.
129(B) IN RURAL AREA
130ACSR DOG
131ACSR RABBIT
132Laying, jointing, stringing, tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc. including proper binding at each end.
133(B) IN RURAL AREA
134G.I.Earth wire 6 SWG
135Earthing of line for all type of supports as per REC construction standards using Stay wire/GI wire with one pcs.of M.S.rod 20mm dia each 3 meter long and driving into earth by mechanical means as per approved design. Drawing & specification. (In case of PCC poles earthing must be connected with earthwire already available on PCC pole at bottom)
136Mesh earthing for 33/11 kv sub-station as per approved map & design using MS flat 50X6mm/MS road 20mm dia including laying of flat/rod at the depth of 0.65 Mtrs., welding & jointing at joints, structures & equipments etc. as under:
137Excavation of trench of 0.65 Mtrs. depth and 0.5 Mtr. width
138Ordinary rock (where blasting is not required).
139Preparation of spikes made of M.S Rod of 20 mm dia and 3 Mtr. length as per design and requirment to be driven in earth by mechanical means and Providing & fastening of suitable clamps with the M.S. Rod, connection of earth wire/stay wire/MS flat in clamp depending on type of soil:
140Where drilling is required
141Filling of trench with available excavated muck in layers of 20cm (Max.) consolidating each deposited layer by ramming & watering with lead up to 50 Mtr, and lift up to 1.5 Mtr.
142Painting of exposed portion of MS flat/rod with two coats of red-oxide primer and two coats of green enamel paint.including material.
143Erection of PCC poles in excavated pit in alignment after checking the same with plumb line as per approved design & drawing of 33/11kv sub-station. The pit should be back filled with the soil with proper ramming below 30cm ground level and then muffed above 15cm average ground level with cement concrete ratio1:3:6. The charges for muffing will be paid extra as per chapter code no 5.7.
144(B) IN RURAL AREA
145PCC Poles 9 Mtr. Long
146Laying / stringing of bus bar with ACSR Dog & jumper connection using tie rod, 33KV /11KV insulator strings, required hardware, P.G.clamps/T clamps etc. as per requirement including Y-connections at bus bar jumpering point as per the direction of engineer in-charge.
147ACSR DOG/RABBIT
148Supply, stacking & spreading of stone boulders 40 mm. Mono size. (Less voids 17%)
149Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization, filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.
15033 KV VCB/SF-6 Breaker
15111 KV OCB/KIOSK
152Installation of current/potential transformers on supporting structure including checking of wiring & conducting all pre-commissioning tests before energization & satisfactory operation in all respect (The CT/PT set will be tested by Discom).
15311 KV CT(1 set of 3 Nos.) OR PT Set
154Laying energisation & commissioning of underground cable for working voltage of 11 KV/33 KV Aluminium conductor, Power cable XLPE/PILCA armoured in RCC class NP-2 Non-pressure pipes of sizes mentioned against each refilling of earth in the remaining excavated area making necessary connection including testing etc. as required (It includes providing, laying & jointing RCC class NP-2 Non-pressure pipes conforming to IS:458 of approved make with collars, jointed with CM 1:20 depth of cable shall be 1.2 meter.
155(A) 33 KV Cable
1563x300 sq. mm in pipe of dia 300 mm
157Providing and fixing of G.I. Pipe of 150 mm diameter. B-Class (IS:1239 mark), at the starting and finishing point of 33 KV under ground cables and to lay & clamp vertically with the existing support including labour charges.
158Installation of metering points on 11 KV Out going feeder at 33/11 KV S/S.
159The installation work to be carried out as per drawing/design, under the supervision of concerned Assistant Engineer
160Mounting structure
161The requisite steel members will be supplied by contractor including the hardware. Contractor shall joint/weld the members to form the mounting structure as per drawing. Necessary tools, welding, machines, lifting devices etc. shall be arranged by contractor.
162Civil works
163Erection of lattices in alignment including excavation and concreting of structure foundation including cement, sand and grit 20 mm size (crusher broken) having ratio 1:3:6 and grit 40 mm size for ratio 1:5:10 and curing for period as required (21 days). Area of concreting will be as per the drawing.
164Metering Equipments:
165The requisite metering equipments (CTPT set, meter, meter box & suitable conductors for jumpers), will be provided by the concerned Assistant Engineer in healthy condition at site. The cables from CTPT set to meter box laid down in 50 mm GI pipe with suitable bends & nipples, shall be provided by contractor alongwith the consumable items such as PVC tapes, petroleum jelly etc. The cable should be PVC multi strand copper 4 core 2.5/4 Sq. mm ISI marked and firm & tight connections shall be made by suitable connector e.g. at CTPT sets by using clamps and at meter/TTB by suitable lugs etc. The CTPT sets so installed shall be earthed by means of the MS Flat (size 50x6 mm) by joining it with the nearest earthing available at the sub-station. Requisite earthing material shall be made available by the contractor.
166Meter:
167Meters should be fixed firmly inside the tamper proof box, as per drawing. All the meter fixture will be provided by contractor including all consumables.
168Meter Box
169The meter box shall be provided by the concerned Assistant Engineer. However, hardware or any other items required to fix the meter inside the meter box will be provided by contractor. The meter box will be fixed firmly with sufficient strength at a place as per drawing. The test terminal block (TTB) link type shall be provided by contractor in the meter box.
170Painting:
171All surfaces interior and exterior of lattice structure shall be white aluminum painted.
172Commissioning of Metering Equipments:
173Installed meters inside the box and metering equipments duly mounted on the mounting structure will be powered up by connecting load in the presence of the concerned Assistant Engineer who will arrange the necessary shut down. The completion certificate shall be furnised by contractor be filled accordingly. Since the work involves higher A.C. voltage level, the contractor shall take full care regarding safety norms, so as to avoid any accidental hazards.
174Painting with priming coats or ready mixed red-oxide paint 2 coats of approved make on steel works after cleaning with wire brush / sand paper. (including cost of red oxide)
175On new surface
176Painting with aluminium paint of approved brand and manufacturer to give an even surface. (including cost aluminium paint)
177On new works with two coats.
178Laying of 11 KV, XLPE, Cable (Aluminium conductor) underground as per relevant IS/JVVNL standards including excavation of 30 cm x 120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class beicks covering refilling soil in the remaining (Including fixing of G.I.Pipe of required size at both end with 3 Mtr projected above the ground surface & 0.3 Mtr. below ground level)
179a) 3x35 Sq mm to 3x185 Sq mm
180Installation of cable termination / straight through joints on 11KV Aluminium conductor XLPE /PILCA Cable with outdoor/ indoor termination end and /or straight through joint including required excavation / remoral/ fixing / refixing/ testing etc. as required
181A) (i) Outdoor end terminal 3x35 Sq mm to 3x185 Sq mm
182Laying of 33 KV XLPE Cable (Aluminium Conductor) underground as per relevant ISS / JVVNL standard including excavation of 30 cm width x120 cm deep trench in Kaccha land 25 cm thick under layer of sand. 'A' class bricks or concrete block covering refilling soil in the remaining portion and providing/fixing cable route indicators at every 30Mtr.of cable and at every turn.
183B) 3x240 Sq mm to 3x400 Sq mm
184Intallation of 33 KV Cable (XLPE) termination / straight through joints (Heat shrinkable type) as per manufacturer's kit guidance and direction including preparation of cable and testing refilling etc as required. (Including crimping of lugs) Including required excavation/ removal/ fixing/ reaffixing/ testing etc. as required.
185(i) Outdoor end terminal
186(ii) 3x240 Sq mm to 3x400 Sq mm
187Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
188(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
189(ii) When the road cutting is not permitted by the local administration.
190A) 33 / 11 KV 3C x 300 Sq.mm cable
191Fixing and assembly of disc.point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design.
19233 KV line
193Laying, testing termination of control cable 1100 volts PVC insulated including supply and installation of ferrules to designate various cores of control cables by terminal Nos. of identification including utilization of cable gland. The control cable should be clearly arranged in trenches avoiding crossings including clamping of control cable at regular interval and providing identify tags.
19412x2.5 Sq.mm.
195Installation of lightening arrestors on erected structure /support (1 nos) including connection with earth by wire /strip as required and jumpering etc.
196(A) sub-station type
19733 KV L.A. each
19811 KV L.A. each
1993 Nos. of earthing of 11/0.4 KV distribution transformer /sub-station with 3 pieces of M.S.Rod 20mm dia each 3 meter long and driving them into earth by mechanical means at a distance as per approved design & drawing & specification. The work includes flattening of top ends of M.S.rod drilling a hole of 9/16\\" dia. at flattened top and tightening of M.S.flat 50x6mm/25x3mm (having 3 hole 2ends and 1mm middle) with nuts and bolts with M.S.rods top end hole. The flat will also be welded with M.S.rod. The end will be connected to equipments as under in sequence.
200Laying of MS flat /MS rod in 0.65Mtr. deep excavated trench and welding of MS flat/rod continuosly with 100 mm overlaping for straight joint including coating of MS flat joints with molten bitumen and covering joint with bitumen impregnated tape to protect from rust.
201Shaping of MS flat for connecting the equipments with earthmesh. The work includes the welding of MS flat with equipments/structure and also with earth mesh. The work also includes coating of MS flat joint with molten bitumen and covering jointwith bitumen impregnated tape to protect from rust.
202Earthing of new 33/11 KV S/S with bentonite compound (including material) involving following activities.
203Digging of 10.5 ft. deep pit of 4 ' dia (approx 132 cu.ft)
204Supply of 2\\" G.I pipe with cap (including fabrication of 30 holes in the periphery of pipe)
205Making chamber for water pouring including cast iron manhole cover
206Supply cost of 200 kg bentonite compound with making slurry
207Supplu of black cotton soil approx 80 cu.ft.
208Connecting electrode with Mesh Earthing
209Erection of OCB/Kiosk/VCB complete with accessories including use of special tools & conducting all pre-commissioning test before energization, filling oil etc. complete in all respect with erection & grouting of structure (excluding civil works). The relays will be tested by Discom.
21011 KV VCB (Outdoor )
211Fixing and assembly of disc.point channel pair with pilot plates top hampers & clamps on erected single pole structure as per design.
21211 KV line
213Fixing of PG clamp of Weasel /Rabbit Conductor
214Fabrication of steel structures of M.S angle, M.S.channel & M.S.Flat including cutting, drilling and continunous welding joint as per design and drawing.
215Other steel items
216Excavation of pit in ordinary rock which does not require blasting/murrad (in Jodhpur discom) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
217(B) Lattice Tower /Size of pit
21811.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
219Excavation of pit in Hard rock (Where blasting/drilling is required) to erect various supports and stay sets including stacking of excavated muck from the edge of excavation/pit.
220(B) Lattice Tower /Size of pit
22111.4/10.8 Mtr/ 1.5mx1.5m x1.80 m deep
222Laying, jointing, stringing, tensioning and clamping of G.I.Earthwire continuosly on single/double pole by using earth clamps /nuts & bolts with washers and earth reel etc. including proper binding at each end.
223(B) IN RURAL AREA
224G.I.Earth wire 8 SWG
225Drawing of overhead ABC conductor (Areal bunched cable) on existing erected pole/support including laying. Jointing, stringing complete in all respect.
2261cX25 + 25 Sq mm
227Pipe Earthing for Power Transformer at 33 / 11 KV S/S:-Supply & erection of earthing electrode shall consist of G.I. Pipe 100 mm. of 3 Mtr Length. The electrode shall be buried as far as practicable 3 meters below ground level. Wherever possible, earth electrodes shall be located as near the water tap, water drain or near down take pipe. Earth electrodes shall not be installed in proximity to a metal fence. It shall be kept clear of the buildings foundations and in no case it shall be nearer than 2 meters from the outer face of the wall. The electrode shall be surrounded with layer of charcoal dust and salt mixture through out the length. The 100 mm GI pipe shall be provided with holes of 12 mm dia. drilled at 75 mm interval upto 2.5 meters length from bottom. The top of the pipe shall be provided with a G.I. threaded cap for watering the earth through a pipe. A Clamp with Pati of 12\\" of M.S. Flat of size 50X6 mm shall be fixed (Bolted) on the top edge of the pipe which in turn shall be connected to Neutral / Body of the Power Transformer through M.S. Flat size 50X6 mm. The G.I. cap over the GI pipe shall be housed in a masonry chamber, approximately 300 mm x 300 mm x 300 mm deep. The masonry chamber shall be provided with a RCC inspection cover resting over a RCC frame, embedded in masonry.
228Fabrication of steel structures of M.S angle, M.S. channel & M.S.Flat including cutting, drilling as per design and drawing.
22911/0.433 KV Substation Structure (185.83 Kg)
23033 KV Line D.P.sets (142.314 Kg)
23133/11 KV Rural Sub-Station Structure (4086.879 Kg)
232Wiring service line from LT Pole to meter of the consumer with 4 Sq.mm. T/C XLPE armoured cable of aluminium conductor confirming to IS (latest amendment) procured as per specification of Nigam and approved vendor of Jaipur Discom duly clipped/hocked and insulating tape complete in all respect.
233For Extra Loop (Ghera) to be provided near the pole on termination point and the length of cable along the pole for mounting of cable jointing kit.
23433 KV Cable:-
2353X240 Sq.mm to 3X400 Sq.mm
236Laying energisation & commissioning of underground cable for working voltage of 11 KV/33 KV Aluminium conductor, Power cable XLPE/PILCA armoured in RCC class NP-2 Non-pressure pipes of sizes mentioned against each refilling of earth in the remaining excavated area making necessary connection including testing etc. as required (It includes providing, laying & jointing RCC class NP-2 Non-pressure pipes conforming to IS:458 of approved make with collars, jointed with CM 1:20 depth of cable shall be 1.2 meter.
237(B) 11 KV Cable
2383x185 sq. mm in pipe of dia 250 mm
239Laying of 33 KV & 11KV XLPE cable without Road cutting i.e. through burrowing machine \\"VERMIER\\".(120 cm deep).Use of this technology must be restricted to the situation like:-
240(i) When the passages available for laying the proposed cable is totally a metal or cement concrete road.
241(ii) When the road cutting is not permitted by the local administration.
242B) 33 / 11 KV below 3C x 300 Sq.mm cable
243For Extra Loop (Ghera) to be provided near the pole on termination point and the length of cable along the pole for mounting of cable jointing kit.
24411 KV Cable:-
2453X35 Sq.mm to 3X185 Sq.mm Percentage BoQ BoQ_Ver3.0 Percentage Normal INR Only INR Select, At Par, Excess (+), Less (-) IOCL Tender Inviting Authority: SUPERINTENDING ENGINEER (TW), JVVNL, JAIPUR Name of Work: Execution of deposit works, including the Supply, Erection, Installation, Testing, and Commissioning of materials/equipment for the construction of 33/11 KV sub-stations, 33 KV & 11 KV overhead Line, laying of 33 KV and 11 KV underground XLPE Cable, construction of 33 KV Bay, 11 KV Bay and shifting of 33 KV & 11 KV line, Metering under Baran circle on turnkey basis against TW/TN-627. Contract No: JPD/SE(TW)/TW/TN-627 Name of the Bidder/ Bidding Firm / Company : ABSTRACT OF PRICE SCHEDULE FOR SUPPLY & ERECTION OF MATERIAL & EQUIPMENT(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
246Description
247Quoted rate in BOQ1- SUPPLY OF MATERIAL AND EQUIPMENT
248Quoted rate in BOQ2- ERECTION OF MATERIAL AND EQUIPMENT Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56504805
AUTHORITY Government Departments
TENDER VALUE 19.44 Crore
LAST DATE 31-07-2026
Authority
Authority Name Jaipur Vidyut Vitran Nigam Limited
Work Description Tender for Execution Of Deposit Works, Including The Supply, Erection, Installation, Testing, And Commissioning Of Materials/Equipment For The Construction Of 33/11 Kv Sub-Stations, 33 Kv & 11 Kv Overhead Line, Laying Of 33 Kv And 11 Kv Underground Xlpe Cable, Construction Of 33 Kv Bay, 11 Kv Bay And Shifting Of 33 Kv & 11 Kv Line, Metering Under Baran Circle On Turnkey Basis Against Tw/Tn-627.
Basic Detail
Tender No TW/TN-627
Bidding Type Tender
Location
City Jaipur
State Rajasthan
Key Dates
Publish Date 17 Jul 2026
Submission Date 31 Jul 2026
Open Date 04 Aug 2026
Finance
Tender Value 19.44 Crore
Tender Fee 2950
EMD 38.88 Lakhs
Exemption Not Available
Document List
5c2694c4-960e-4586-ac1e-c60a382300a8.html
627BDoc.pdf
BOQ_1023224.xls
Tendernotice_1 (29).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 10 days
Aug 04, 2026

Bid Opening Date

Technical bids will be opened and evaluated.