Tender For Rate Contract For Electrical Maintenance Works In Cochin Shipyard Limited For The Year 2026-28
Tender Value
1.78 Crore
Estimated cost
Bid Submission
04 Aug 2026
17 days left
EMD
89085
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ernakulam → Kerala
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Rate Contract For Electrical Maintenance Works In Cochin Shipyard Limited For The Year 2026-28
BOQ
| Sl. No. | Item Description |
| 1 | SUPPLY - WIRING |
| 2 | Supply of material for wiring of light point/ fan point/ exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable in surface / recessed with 20mm medium class, ISI marked PVC conduit / casing and capping, with one way modular switch, modular plate, suitable size modular PVC/GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable (Green) etc. as required.Note: Upto 5Mtr length from Switch board to pointMake:Cable:Polycab/Lapp/Finolex/V-Guard/Havells/Helu/RR/ Gloster/Traco or any reputed makeSwitch&Socket: Myrius of Legrand/ Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 3 | Supply of material for wiring of twin control light point with 1.5 sq.mm FRLS PVC insulated, 650V, copper conductor single core cable in surface / recessed with 20mm medium class, ISI marked PVC conduit / casing and capping, 2 way modular switch, modular plate, suitable size modular PVC/GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated, 650V, copper conductor single core cable (Green) etc. as required.Note: Cost for one pointMake:Cable:Lapp/Finolex/V-Guard/ polycab/Helu/RR/GlosterSwitch & Socket: Anchor/MK/GM/ any substantially equivalent make only |
| 4 | Supply of material for wiring of circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V, copper conductor, single core cable in surface / recessed with 20/25/32mm medium class, ISI marked, PVC conduit/casing and capping as required.Make: Cable:Polycab/Lapp/Finolex/V-guard/Havells/Helu/RR/ Gloster/Traco or any reputed make or any substantially equivalent make only |
| 5 | 2x1.5 sq.mm + 1x1.5 sq.mm earth |
| 6 | 2x2.5sq.mm + 1x2.5 sq.mm earth |
| 7 | 2x4 sq.mm + 1x4 sq.mm earth |
| 8 | 2x6 sq.mm + 1x6 sq.mm earth |
| 9 | 2x10 sq.mm + 1x6 sq.mm earth |
| 10 | 2x16 sq.mm + 1x6 sq.mm earth |
| 11 | 4x2.5 sq.mm + 2x2.5 sq.mm earth |
| 12 | 4x4 sq.mm + 2x4 sq.mm earth |
| 13 | 4x6 sq.mm + 2x6 sq.mm earth |
| 14 | 4x10 sq.mm + 2x6 sq.mm earth |
| 15 | 4x16 sq.mm + 2x6 sq.mm earth |
| 16 | Supply of material for rewiring of light point/ fan point/ exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable as earth wire in existing surface/concealed, ISI marked PVC conduit including providing connections, dismantling of existing wiring etc. as required. Note: Upto 5Mtr length from Switch board to pointMake:Cable:Polycab/Lapp/Finolex/V-Guard/Havells/Helu/RR/ Gloster/Traco or any substantially equivalent make only |
| 17 | Supply of material for wiring of group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch) with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable with 20mm Medium class, in surface / recessed ISI marked PVC conduit/ casing and caping, and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable etc. as required. Note: Upto 5m length in between two adjacent points.Excluding the cost of first pointMake:Cable: Polycab/Lapp/Finolex/V-Guard/Havells/Helu/RR /Gloster/ Traco or any substantially equivalent make only |
| 18 | Supply of following size modular PVC box on surface mode as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 19 | 1 or 2 Module |
| 20 | 3 Module |
| 21 | 4 Module |
| 22 | 6 Module |
| 23 | 8 Module |
| 24 | 12 Module |
| 25 | Supply of following size modular GI box in concealed mode along with modular base & cover plate for modular switches as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 26 | 1 or 2 Module |
| 27 | 3 Module |
| 28 | 4 Module |
| 29 | 6 Module |
| 30 | 8 Module |
| 31 | 12 Module |
| 32 | Supply of following size Modular Switch on existing modular switch box/cover including connections etc. as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 33 | 1 Module, 1 Way, 5/6A |
| 34 | 1 Module, 1 Way, 15/16A |
| 35 | 2 Module, 1 Way, DP, 20A with indication |
| 36 | 2 Module, 1 Way, DP, 32A with indication |
| 37 | Supply of following size Modular Socket on existing modular switch box/cover including connections etc. as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 38 | 2 Module, 5 Pin, 6A |
| 39 | 2 Module, 3 Pin, 6/16A |
| 40 | 2 Module, 3 Pin, 25A |
| 41 | Supply of 100 Watt stepped electronic fan regulator (2M) on the existing box/cover including connections etc. as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 42 | Supply of modular blanking plate on the existing modular switch box excluding modular plate as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 43 | 1 Module |
| 44 | 2 Module |
| 45 | Supply of following Modular base & cover plate on existing modular PVC/GI box.Make:Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 46 | 1 Module |
| 47 | 2 Module |
| 48 | 3 Module |
| 49 | 4 Module |
| 50 | 6 Module |
| 51 | 8 Module |
| 52 | 12 Module |
| 53 | Supply of suitable size PVC/GI modular box with modular plate, cover, providing and fixing one number of 3 pin 5/6 A modular socket outlet (2M) and one number of 5/6 A modular switch (1M), including providing connections etc. as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 54 | Surface Mode |
| 55 | Concealed Mode |
| 56 | Supply of suitable size PVC /GI modular box with modular plate,cover, providing and fixing one number of 15/16 A modular socket outlet (2M) and one number of 15/16 A modular switch (1M). Including providing connections etc. as requiredMake: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 57 | Surface Mode |
| 58 | Concealed Mode |
| 59 | Supply of suitable size Gl/PVC box with modular plate, cover, providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets (2M) and 2 Nos. 5/6 A modular switches (1M), including providing connection etc. as required.Make: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 60 | Surface Mode |
| 61 | Concealed Mode |
| 62 | Supply of suitable size Gl/PVC box with modular plate, cover, providng and fixing 3 Nos. 3 pin 5/6 A modular socket outlets (2M) and 2 Nos. 5/6 A modular switches (1M) including providing connection etc. as required - Computer pointMake: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 63 | Surface Mode |
| 64 | Concealed Mode |
| 65 | Supply of suitable size GI/PVC boxes with modular plates, covers, 20/25A modular socket outlet (2M), 20/25 A Double pole modular one way switch (2M) at indipendent position excluding wiring-AC PointNote: Switch and socket shall be provided at independent locationMake: Myrius of Legrand/Opale of Schneider or equivalent Siemens/L&T or any substantially equivalent make only |
| 66 | Surface Mode |
| 67 | Concealed Mode |
| 68 | SUPPLY - DISTRIBUTION BOARDS AND SWITCH GEARS (MCCB, MCB, RCCB) |
| 69 | Supply of following way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on surface complete with 100A fully insulated tinned copper bus bar, shrouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 70 | 4 way |
| 71 | 8 way |
| 72 | 12 way |
| 73 | Supply of following way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on concealed mode complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 74 | 4 way |
| 75 | 8 way |
| 76 | 12 way |
| 77 | Supply of following way, horizontal type three pole and neutral (TPN), sheet steel, MCB double door distribution board , 415 V, on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar, earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 78 | 4 way(8 + 12 ) |
| 79 | 6 way (8 + 18 ) |
| 80 | 8 way (8 + 24 ) |
| 81 | 12 way (8 + 36) |
| 82 | 16 way (8 + 48 ) |
| 83 | Supply of following way, horizontal type three phase and neutral (TPN), sheet steel, 415 V MCB double door distribution board on concealed mode, complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator).Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 84 | 4 way(8 + 12 ) |
| 85 | 6 way (8 + 18 ) |
| 86 | 8 way (8 + 24 ) |
| 87 | 12 way (8 + 36) |
| 88 | 16 way (8 + 48 ) |
| 89 | Supply of following way, vertical type three phase and neutral (VTPN), sheet steel, 415V MCB double door distribution board on surface with dust protected,duly powder coated, inclusive of 100 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(without MCB and incomer) Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 90 | 4 way (8 + 12 ) |
| 91 | 8 way (8 + 24 ) |
| 92 | 12 way (8 + 36 ) |
| 93 | Supply of following way, vertical type three phase and neutral (VTPN) , sheet steel, 415 V, MCB double door distribution board on concealed mode, dust protected, duly powder coated, inclusive of 100 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(without MCB and incomer) Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 94 | 4 way (8 + 12 ) |
| 95 | 8 way (8 + 24 ) |
| 96 | 12 way (8 + 36 ) |
| 97 | Supply of following way, vertical type three phase and neutral (VTPN), sheet steel, 415 V, MCCB double door distribution board on surface mode, dust protected, duly powder coated, inclusive of 160 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(125/160A MCCB incomer type without MCB and incomer) Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 98 | 4 way (MCCB +3 x 4) |
| 99 | 8 way (MCCB +3 x 8) |
| 100 | 12 way (MCCB +3 x 12) |
| 101 | Supply of following way, vertical type three phase and neutral (VTPN) , sheet steel, 415 V, MCCB double door distribution board on concealed mode, dust protected, duly powder coated, inclusive of 160 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(125/160A MCCB incomer type without MCB and incomer) Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 102 | 4 way (MCCB +3 x 4) |
| 103 | 8 way (MCCB +3 x 8) |
| 104 | 12 way (MCCB +3 x 12) |
| 105 | Supply of single pole blanking plate in the existing MCB DB complete etc. as required.Make:Legrand, Schneider, Siemens, ABB, L&T/any substantially equivalent make only |
| 106 | Supply of cable end box (IP 43) suitable for following Single Phase and neutral (SPN) MCB DB on surface.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 107 | For 4 Way SPN DB |
| 108 | For 8 Way SPN DB |
| 109 | For 12 Way SPN DB |
| 110 | Supply of cable end box (IP 43) suitable for following Single Phase and neutral (SPN) MCB DB in concealed mode.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 111 | For 4 Way SPN DB |
| 112 | For 8 Way SPN DB |
| 113 | For 12 Way SPN DB |
| 114 | Supply of cable end box (IP 43) suitable for following TPN MCB DB on surface.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 115 | For 4 Way TPN DB |
| 116 | For 8 Way TPN DB |
| 117 | For 12 Way TPN DB |
| 118 | For 16 Way TPN DB |
| 119 | Supply of cable end box (IP 43) suitable for following TPN MCB DB in concealed mode.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 120 | For 4 Way TPN DB |
| 121 | For 8 Way TPN DB |
| 122 | For 12 Way TPN DB |
| 123 | For 16 Way TPN DB |
| 124 | Supply of cable end box (IP 43) suitable for three phase and neutral, Vertical (VTPN) MCB DB.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 125 | Surface Mode |
| 126 | Concealed Mode |
| 127 | Supply of cable end box (IP 43) suitable for three phase and neutral, Vertical (VTPN) MCCB DB.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 128 | Surface Mode |
| 129 | Concealed Mode |
| 130 | Supply of sheet steel enclosure for DP/TP/FP MCB complete with connections, testing and commissioning etc. as required.Make: Ekinox³ of Legrand, Acti-9 of Schneider or equivalent Siemens/ABB/L&T or any substantially equivalent make only |
| 131 | Surface Mode |
| 132 | Concealed Mode |
| 133 | Providing following rating and breaking capacity 3 Pole MCCB with Microprocessor based LSIG (Over load, Short circuit, Instantanious and Ground fault) release, Ics=100% Icu, Ue= 415VAC, in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make: L&T: D sine MCCB with MTX 2.0 release or equivalent Legrand/Schneider/Siemens/ABB or any substantially equivalent make only |
| 134 | 63A, 36 kA |
| 135 | 125A, 36 kA |
| 136 | 250A, 36 kA |
| 137 | 400A, 36 kA |
| 138 | 630A, 50 kA |
| 139 | Providing following rating and breaking capacity 4 Pole MCCB with Microprocessor based LSIG (Over load, Short circuit, Instantanious and Ground fault) release, Ics=100% Icu, Ue= 415VAC, in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.Make: L&T: D sine MCCB with MTX 2.0 release or equivalent Legrand/Schneider/Siemens/ABB or any substantially equivalent make only |
| 140 | 63A, 36 kA |
| 141 | 125A, 36 kA |
| 142 | 250A, 36 kA |
| 143 | 400A, 36 kA |
| 144 | 630A, 50 kA |
| 145 | Supply of 6/10/16/20/25/32A rating, 240/ 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens or any substantially equivalent make only |
| 146 | Single Pole |
| 147 | Double Pole |
| 148 | Three Pole |
| 149 | Four Pole |
| 150 | Supply of 40/50/63A rating, 240/ 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens or any substantially equivalent make only |
| 151 | Single Pole |
| 152 | Double Pole |
| 153 | Three Pole |
| 154 | Four Pole |
| 155 | Supply of following rating, double pole (single phase and neutral), 240 V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens or any substantially equivalent make only |
| 156 | 100 A |
| 157 | Supply of following rating, double pole (single phase and neutral), 240 V, RCCB, having a sensitivity current of 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens or any substantially equivalent make only |
| 158 | 100 A |
| 159 | Supply of following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens or any substantially equivalent make only |
| 160 | 100 A |
| 161 | Supply of following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens or any substantially equivalent make only |
| 162 | 100 A |
| 163 | Supply of Digital Astronomical time switch, 2M, din rail mount (suitable for MCB DB), 24Hrs, LCD with background lighting, 10A 1SPDT/2SPDT contact, 230VAC, 1phase, Automatic Summer/winter, ROM storage.Make: Legrand, Schneider, Siemens, L&T or any substantially equivalent make only |
| 164 | One channel |
| 165 | Two channel |
| 166 | FN Open Execution (Suitable for cylindrical/DIN fuse link)No. of poles : TPN/FP, Icu : 25kA/36kA/50kA, Ics : 100%, Ue : 415V AC 50Hz, Ui:690V, Uimp : 8kVMake: L&T or any reputed make |
| 167 | FN inSS EnclosureNo. of poles : TPN/FP, Icu : 25kA/36kA/50kAIcs : 100%, Ue : 415V AC 50Hz, Ui:690V, Uimp : 8kVMake: L&T or any reputed make |
| 168 | Supply of Junction Box, Material : Polycarbonate, IP 66 of following sizes for 3 phase power supply including connector as required |
| 169 | 1.5 - 4 sq.mm (130 x 180 x 77 Approx.) |
| 170 | 4 - 10 sq.mm (155 x 210 x 92 Approx) |
| 171 | LIGHT FITTINGS, FANS AND AIR CONDITIONING UNITS |
| 172 | Supply of 18/20W, 1700-2100 lumen output, 230V AC, single phase, 50 Hz, IP 20, 1200 mm length T8 LED tube with extruded aluminium/ polycarbonate body, inbuilt driver complete with pre wired, CRCA batten etc. as required. 18-20W LED/ CRCA batten Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 173 | Supply of surface mounted 1700-2100 lumen output, 230V AC, single phase, 50 Hz, 1200 mm length, T5 LED tube integral light fittings with extruded plastic body complete accessories including inbuilt LED drive, LED tube etc. as required.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 174 | 18-20W 4F/1200mm |
| 175 | 8-10W 2F/600mm |
| 176 | Supply of Integral LED street light luminaries, 230VAC, 1Ф, 50Hz comprising of epoxy power coated hsg, enclosed with glass cover in frame. Suitable for 50mm OD pipe, Ingress Protection IP66, luminus efficiency ≥120 lm/Watt, integral driver, inbuilt surge suppressor of 10 kV or above with complete accessories as required. Two year on site OEM warranty shall be provided at the time of delivery.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 177 | 45W LED for 5m height |
| 178 | 70-80W LED for 5m height |
| 179 | 90W LED for 12m height |
| 180 | 120W LED for 12m height |
| 181 | 150W LED for 12m height |
| 182 | 200W LED for 12m height |
| 183 | Supply of LED high bay luminaires 230VAC, 1Ф, 50Hz with integral driver, frame, totally enclosed aluminium PDC housing, toughened glass, Ingress Protection IP66, luminus efficiency ≥140 lm/Watt, round type, integral driver with complete accessories as required. Two year on site OEM warranty shall be provided at the time of delivery.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 184 | Supply of LED Flood light luminaires 230VAC, 1Ф, 50Hz comprising of epoxy power coated with IP 66 protection, PDC housing, heat resistant toughened glass, luminus efficiency ≥140 lm/Watt, integral driver with complete accessories as required. Two year on site OEM warranty shall be provided at the time of delivery.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 185 | 70-80W |
| 186 | 100-120W |
| 187 | 150-160W |
| 188 | 190-200W |
| 189 | 320-350W |
| 190 | Supply of 30W LED Wellglass luminaires 230VAC, 1Ф, 50Hz with IP 66 protection, Luminaire efficacy ≥140Lm/Watt, complete accessories as required. Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 191 | Supply of LED flameproof batten with T8 LED Tube, 18/20W for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP66 Protected. Test certificates and two year warranty certificate of the light fittings should be submitted at the time of delivery. Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 192 | Supply of 70W LED flameproof Wellglass For Gas/Vapor group of IIA , IIB & IIC and Zone 1 & 2. IP66 Protected. Test certificates and two year warranty certificate of the light fittings should be submitted at the time of delivery. Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 193 | Supply of 230VAC, 1Ø, LED modular surface/recess round/square Panel/Down light fitting with supporting bracket/chain complete accessories as required.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 194 | 6-10W |
| 195 | 12-15W |
| 196 | Supply of LED mirror light fitting with supporting bracket as required.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 197 | 9-14W |
| 198 | 15-18W |
| 199 | Supply of 600X600 mm, 230VAC, 1Ø, 34-36W LED light fitting with supporting brackets and chain as required. Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 200 | Supply of Light weight ,Sleek ,Aluminium & high Performance batten (20W) with Opal diffuser which provides smooth light distribution having Inbuilt occupancy sensor. Upto 10 mtr (Diameter) sensor coverage area.Mounting Height – upto10ft. 30% light output in case of non-occupancy. Suitable for surface mounting application.Make:Crompton/Havells/Bajaj/Philips/Wipro/Osram/LT or any substantially equivalent make only |
| 201 | Supply of Ceiling fan BLDC, 230V, 50Hz , 5 star rating complete accessories as required.1200 mm sweep, 28- 35 W (Remote Control) Make: Crompton/Bajaj/Usha/Atomberg/any substantially equivalent make only |
| 202 | Supply of 400 mm wall fan BLDC, 5 star rating, 230V, 50HZ, 30W, 1350-1500 rpm, 65-75 CMM, 45-57dB noise level, variable speed with ocsillation complete accessories as required. Make: Crompton/Bajaj/Usha/Atomberg/any substantially equivalent make only |
| 203 | Supply of BLDC exhaust fan shutter type, 230V, 50HZ, 20-30W/30-40W/30-40W, 1300 rpm, 250/500/850 CMM, 30-40db noise level, automatic shutter complete accessories as required.Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard or any substantially equivalent make only |
| 204 | 150mm sweep |
| 205 | 200mm sweep |
| 206 | Supply of exhaust fan shutter type, 230V, 50HZ, 20-30W/30-40W/30-40W, 1300 rpm, 250/500/850 CMM, 30-40db noise level, automatic shutter complete accessories as required.Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard or any substantially equivalent make only |
| 207 | 250mm sweep |
| 208 | Supply of exhaust fan -LD/HD, 230V, 50HZ, 40-60W/75-95W/75-100W, 1300 rpm, 1000/1900 CMM, 40-45db noise level, bird screen protection complete accessories as required.Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard or any substantially equivalent make only |
| 209 | 300 LD |
| 210 | 300 HD |
| 211 | Supply of BLDC Pedestal fan 400mm Sweep, variable speed with Oscillation, 230V, 50HZ, 35W, 76 CM/M Air Delivery complete accessories as required. Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard or any substantially equivalent make only |
| 212 | Supply of Pedestal fan 450mm sweep, variable speed with Oscillation, 230V, 50HZ, 100-120W/150-160W, 90/145 CM/M Air Delivery complete accessories as required. Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard or any substantially equivalent make only |
| 213 | Supply of industrial Air circulator with Oscillation, 230V, 50HZ, 3 Speed, 80-95W/175-185W, 150/280CMM complete accessories as required.Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard or any substantially equivalent make only |
| 214 | Wall mounted type 450mm sweep |
| 215 | Wall mounted type 600mm sweep |
| 216 | Pedestal type 450mm sweep |
| 217 | Pedestal type 600mm sweep |
| 218 | Supply of Voltage Stabilizer, Wall mounting, 230VAC, 1Phase, 50Hz.Make: Crompton/ Bajaj/ Usha/ Havells/ Almonard/V-Guard/ Microtek/ Everest/ Monitor/Bluebird or any substantially equivalent make only |
| 219 | Supply of 8mm thread rod for supporting cassette type Indoor unit / outdoor unit |
| 220 | Supply of copper tube of size 1/2\\" or 5/8\\" (Suction Line) and 1/4\\" or 3/8\\" (Liquid line) for interconnecting indoor and outdoor units as required. |
| 221 | Supply of 2HP/3HP/5HP DOL Motor Starters, 3Ø, 415V,50Hz, Overload Relay Range -2.4 to 9.3A, Contactor Type-C00N, Contactor Rating (AC-3)-16AMake:NAGLEN/NAHLEN/NAJLEN of BCH/ equivalent of Siemens/Schnieder/L&T or any substantially equivalent make only |
| 222 | Supply of 2HP/3HP/5HP Fully Automatic Star Delta Starter with NHD Contactor & Pneumatic Timers of following range, 3Ø, 415V,50Hz, Overload Relay Range -6A to 24A, Contactor Type-C00N, Contactor Rating (AC-3)-16A-25AMake:NASAJLEN/NASAKLEN/NASALLEN/NASAMLEN of BCH/ equivalent of Siemens/Schnieder/L&T or any substantially equivalent make only |
| 223 | 10HP/15HP |
| 224 | SUPPLY OF LT CABLE |
| 225 | Supply of one run Aluminium Conductor (solid upto 10 sq.mm & stranded for balance), XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type ST2 Outer Sheathed power cable of 1.1 kV grade (A2XWY) of following size as per IS-7098(part 1) 2011. (cost for 1 Meter)Make:Lapp/Finolex/V-Guard/Havells/Helukable/ RR/ Gloster/ Nicco/ Universal/ CCI/Ravin/ Torrent/ Traco/ Polycab or any substantially equivalent make only |
| 226 | Upto 3 core X 4 Sq.mm A2XFY |
| 227 | 3 core X 6 Sq.mm A2XFY |
| 228 | 3 core X 240 Sq.mm A2XFY |
| 229 | 3 core X 300 Sq.mm A2XFY |
| 230 | 3 core X 400 Sq.mm A2XFY |
| 231 | 3.5 core X 25 Sq.mm A2XFY |
| 232 | 3.5 core X 35 Sq.mm A2XFY |
| 233 | 3.5 core X 50 Sq.mm A2XFY |
| 234 | 3.5 core X 70 Sq.mm A2XFY |
| 235 | 3.5 core X 95 Sq.mm A2XFY |
| 236 | 3.5 core X 120 Sq.mm A2XFY |
| 237 | 3.5 core X 150 Sq.mm A2XFY |
| 238 | 3.5 core X 185 Sq.mm A2XFY |
| 239 | 3.5 core X 240 Sq.mm A2XFY |
| 240 | 3.5 core X 300 Sq.mm A2XFY |
| 241 | 3.5 core X 400 Sq.mm A2XFY |
| 242 | 4 core X 4 Sq.mm A2XFY |
| 243 | 4 core X 6 Sq.mm A2XFY |
| 244 | 4 core X 10 Sq.mm A2XFY |
| 245 | 4 core X 16 Sq.mm A2XFY |
| 246 | 4 core X 25 Sq.mm A2XFY |
| 247 | 4 core X 35 Sq.mm A2XFY |
| 248 | 4core X 50 Sq.mm A2XFY |
| 249 | 4 core X 70 Sq.mm A2XFY |
| 250 | 4core X 95 Sq.mm A2XFY |
| 251 | 4core X 120 Sq.mm A2XFY |
| 252 | 4core X 150 Sq.mm A2XFY |
| 253 | 4core X 185 Sq.mm A2XFY |
| 254 | 4core X 240 Sq.mm A2XFY |
| 255 | 4core X 300 Sq.mm A2XFY |
| 256 | 4core X 400 Sq.mm A2XFY |
| 257 | Supply of one run Copper Conductor, XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type Outer Sheathed power cable of 1.1 kV grade (2XFY) of following size as per IS-7098(part 1) 2011. (cost for 1 Meter)Make:Lapp/Finolex/V-Guard/Havells/Helukable/ RR/ Gloster/ Nicco/ Universal/ CCI/Ravin/ Torrent/ Traco/ Polycab or any substantially equivalent make only |
| 258 | 3 core X 1.5 Sq.mm 2XFY |
| 259 | 3 core X 2.5 Sq.mm 2XFY |
| 260 | 3 core X 4 Sq.mm 2XFY |
| 261 | 3 core X 6 Sq.mm 2XFY |
| 262 | 3 core X 10 Sq.mm 2XFY |
| 263 | 3 core X 16 Sq.mm 2XFY |
| 264 | 3 core X 25 Sq.mm 2XFY |
| 265 | 4 core X 1.5 Sq.mm 2XFY |
| 266 | 4 core X 2.5 Sq.mm 2XFY |
| 267 | 4 core X 4 Sq.mm 2XFY |
| 268 | 4 core X 6 Sq.mm 2XFY |
| 269 | 4 core X 10 Sq.mm 2XFY |
| 270 | 4 core X 16 Sq.mm 2XFY |
| 271 | 4 core X 25 Sq.mm 2XFY |
| 272 | Supply of flexible copper cable, solid/ stranded copper conductor, PVC insulated, core laid up, PVC tape/ PVC extruded innersheathed for multicore cables, unarmoured, extruded PVC type ST2 sheathed 650/ 1100 V grade as per IS 7098(part 1) 1988. (cost for 1 Meter)Make:Lapp/Finolex/V-Guard/Havells/Helukable/ RR/ Gloster/ Nicco/ Universal/ CCI/Ravin/ Torrent/ Traco/ Polycab or any substantially equivalent make only |
| 273 | 3 core X 2.5 Sq.mm YY |
| 274 | 3 core X 4 Sq.mm YY |
| 275 | 3 core X 6 Sq.mm YY |
| 276 | 3 core X 10 Sq.mm YY |
| 277 | 3 core X 16 Sq.mm YY |
| 278 | 3 core X 25 Sq.mm YY |
| 279 | 4 core X 2.5 Sq.mm YY |
| 280 | 4 core X 4 Sq.mm YY |
| 281 | 4 core X 6 Sq.mm YY |
| 282 | 4 core X 10 Sq.mm YY |
| 283 | 4 core X 16 Sq.mm YY |
| 284 | 4 core X 25 Sq.mm YY |
| 285 | 5 core X 2.5 Sq.mm YY |
| 286 | 5 core X 4 Sq.mm YY |
| 287 | 5 core X 6 Sq.mm YY |
| 288 | HT CABLE- SUPPLY & LAYING |
| 289 | Supply of stranded compact circular Aluminium conductor, conductor screened with extruded semi conducting component, XLPE insulated, insulation screened with extruded semi conducting component in combination with copper tape, Aluminium flat strip/ round wire armoured, and overall PVC ST2 sheathed 11 kV grade three core HT cable of following size in the existing RCC/HUME/METAL pipe as required. (conforming to IS:7098 part II 2011)Make:Lapp/Finolex/V-Guard/Havells/Helukable/ RR/ Gloster/ Nicco/ Universal/ CCI/Ravin/ Torrent/ Traco/ Polycab or any substantially equivalent make only |
| 290 | 95 Sq.mm |
| 291 | 120 Sq.mm |
| 292 | 150 Sq. mm |
| 293 | 185 Sq.mm |
| 294 | 240 Sq.mm |
| 295 | 300 Sq. mm |
| 296 | 400 Sq. mm |
| 297 | LT CABLE JOINTING AND END TERMINATION |
| 298 | Supply of brass single compression gland and Heavy duty Aluminium long barrel lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.( Including supply of gland and lugs as required )Make: Hex/Jainson/Commet or any substantially equivalent make only |
| 299 | 3x6 sq. mm (19mm) |
| 300 | 3x10 sq. mm (22mm) |
| 301 | 3x16 sq. mm (25mm) |
| 302 | 3x25 sq. mm (25mm) |
| 303 | 3x35 sq. mm (28mm) |
| 304 | 3x50 sq. mm (32mm) |
| 305 | 3x120 sq. mm (45mm) |
| 306 | 3x240 sq. mm (50mm) |
| 307 | 3x300 sq. mm (57mm) |
| 308 | 3x400 sq. mm (63mm) |
| 309 | 3.5 X 25 sq. mm (28mm) |
| 310 | 3.5 X 35 sq. mm (32mm) |
| 311 | 3.5 X 50 sq. mm (35mm) |
| 312 | 3.5 X 70 sq. mm (38mm) |
| 313 | 3.5 X 95 sq. mm (45mm) |
| 314 | 3.5 X 120 sq. mm (45mm) |
| 315 | 3.5 X 150 sq. mm (50mm) |
| 316 | 3.5 X 185 sq. mm (57mm) |
| 317 | 3.5 X 240 sq. mm (62mm) |
| 318 | 3.5 X 300 sq. mm (70mm) |
| 319 | 3.5 X 400 sq. mm (82mm) |
| 320 | 4 X 10 sq. mm (25mm) |
| 321 | 4 X 16 sq. mm (28mm) |
| 322 | 4 X 25 sq. mm (28mm) |
| 323 | 4 X 35 sq. mm (32mm) |
| 324 | 4 X 50 sq. mm (35mm) |
| 325 | Supply of brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required )Make: Hex/Jainson/Commet or any substantially equivalent make only |
| 326 | 3x4 sq. mm (19mm) |
| 327 | 3x6 sq. mm (19mm) |
| 328 | 3x10 sq. mm (22mm) |
| 329 | 3x240 sq. mm (50mm) |
| 330 | 3x300 sq. mm (57mm) |
| 331 | 3x400 sq. mm (63mm) |
| 332 | 3.5x25 sq. mm (28mm) |
| 333 | 3.5x35 sq. mm (32mm) |
| 334 | 3.5x50 sq. mm (35mm) |
| 335 | 3.5x70 sq. mm (38mm) |
| 336 | 3.5x95 sq. mm (45mm) |
| 337 | 3.5x120 sq. mm (45mm) |
| 338 | 3.5x150 sq. mm (50mm) |
| 339 | 3.5x185 sq. mm (57mm) |
| 340 | 3.5x240 sq. mm (63mm) |
| 341 | 3.5x300 sq. mm (63mm) |
| 342 | 3.5x400 sq. mm (70mm) |
| 343 | 4 X 2.5 sq. mm (19mm) |
| 344 | 4 X 4 sq. mm (22mm) |
| 345 | 4 X 6 sq. mm (22mm) |
| 346 | 4 X 10 sq. mm (25mm) |
| 347 | 4 X 16 sq. mm (25mm) |
| 348 | 4 X 25 sq. mm (28mm) |
| 349 | 4 X 35 sq. mm (32mm) |
| 350 | 4 X 50 sq. mm (35mm) |
| 351 | Supplying part of indoor/outdoor straight through cable joint with heat shrinkable cable jointing kit including heavy duty aluminium long barrel lugs and other end termination materials for following size of aluminium conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.Make: Denson/Raychem/3M/any substantially equivalent make only |
| 352 | 3/4 Core 16 sq. mm |
| 353 | 3/3.5/4 Core 25 sq. mm to 3/3.5 Core 50 sq. mm |
| 354 | 4 Core 35 sq. mm to 4 Core 50 sq. mm |
| 355 | 3/3.5 Core 70 sq. mm |
| 356 | 3/3.5 Core 95 sq. mm |
| 357 | 3/3.5 Core 120 sq. mm to 3/3.5 Core 185 sq.mm |
| 358 | 3/3.5 Core 240 sq. mm |
| 359 | 3/3.5 Core 300 sq. mm |
| 360 | 3.5 Core 400 sq. mm |
| 361 | HT CABLE JOINTING AND END TERMINATION |
| 362 | Supplying and making indoor/outdoor straight through cable joint with heat shrinkable cable jointing kit including heavy duty aluminium long barrel lugs and other end termination materials for following size of aluminium conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 11 kV grade as required.Make: Denson/Raychem/3M/any substantially equivalent make only |
| 363 | 3 Core 120 sq. mm |
| 364 | 3 Core 240 sq. mm to 3 Core 300 sq. mm |
| 365 | EARTHING |
| 366 | Earthing with copper earth plate 600 x 600 x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 meter long etc. with charcoal/ coke and salt as required.(Details of cost for one each) Make: Cape/Erico/Furse/OBO |
| 367 | Maintenance free Earthing -Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. Universal Clamp should be exothermic moulded along with earth rod. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have minimum 20 Kg of the total composite. If using chemical compound min 37.5 Kg is required. Polypropylene & Polyethylene Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 170mm with a weight bearing capacity of 50KN. Make:Cape/Erico/Furse/OBO |
| 368 | Supplying and laying 6 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 369 | Supplying and laying 8 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 370 | Supplying and laying 10 SWG Copper wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 371 | Supplying and laying 12 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 372 | Supplying and laying 14 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 373 | Providing and fixing 32x6 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 374 | Providing and fixing 25x6 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 375 | Providing and fixing 25x3 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 376 | Providing and fixing 32x6 mm GI strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 377 | Providing and fixing 50x6 mm GI strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 378 | Providing and laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3 mm solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. Needs to be installed 0.5 meter from earth. |
| 379 | Providing and laying copper bonded steel solid tape conductor 16mm diameter having 200Sq mm cross sectional area (if required 300Sqmm then 2 runs has to be considered) from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 32x6 solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. Needs to be installed 0.5 meter from earth. |
| 380 | MISCELLANEOUS ITEMS |
| 381 | Capacitor of ceiling fan / exhaust fan / pedestal fan / wall fan etc |
| 382 | Panel board painting |
| 383 | Steel work for panel maintenance |
| 384 | GI pipe as par IS/1239 ISI Marked C Class (heavy) |
| 385 | 32 mm dia G.I. Pipe |
| 386 | 50 mm dia G.I. Pipe |
| 387 | 80 mm dia G.I. Pipe |
| 388 | 100 mm dia G.I. Pipe |
| 389 | GI pipe as par IS/1239 ISI Marked C Class (medium) |
| 390 | 32 mm dia G.I. Pipe |
| 391 | 50 mm dia G.I. Pipe |
| 392 | 80 mm dia G.I. Pipe |
| 393 | Supply of cable ladder (aluminium) with all accessories as per technical specificationSpan: 300mmWidth: 300mmMaterial: Aluminium channel and Aluminium rod |
| 394 | Supplying of extra down rod of 19mm dia heavy gauge including painting etc. as required for ceiling fan |
| 395 | Checking, cleaning and refitting/dismantling of existing fans including supply and replacement of nut& bolt, lock pins, bush of ceiling fan |
| 396 | Painting of ceiling fan with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 397 | Providing stainless steel fan hooks on the ceiling by chipping and grouting |
| 398 | Checking and rectifying the defects in circuits, changing fuse base, carrier, connectors etc. in junction boxes / terminal boxes of streetlights. |
| 399 | SERVICE - WIRING |
| 400 | Wiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable in surface / recessed with 20mm medium class, ISI marked PVC conduit / casing and capping, with one way modular switch, modular plate, suitable size modular PVC/GI box and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable (Green) etc. as required.Note: Upto 5Mtr length from Switch board to point |
| 401 | Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated, 650V, copper conductor single core cable in surface / recessed with 20mm medium class, ISI marked PVC conduit / casing and capping, 2 way modular switch, modular plate, suitable size modular PVC/GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated, 650V, copper conductor single core cable (Green) etc. as required.Note: Upto 5Mtr length from Switch board to point |
| 402 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated, 650V, copper conductor, single core cable in surface / recessed with 20/25/32mm medium class, ISI marked, PVC conduit/casing and capping as required. |
| 403 | 2x1.5 sq.mm + 1x1.5 sq.mm earth |
| 404 | 2x2.5sq.mm + 1x2.5 sq.mm earth |
| 405 | 2x4 sq.mm + 1x4 sq.mm earth |
| 406 | 2x6 sq.mm + 1x6 sq.mm earth |
| 407 | 2x10 sq.mm + 1x6 sq.mm earth |
| 408 | 2x16 sq.mm + 1x6 sq.mm earth |
| 409 | 4x2.5 sq.mm + 2x2.5 sq.mm earth |
| 410 | 4x4 sq.mm + 2x4 sq.mm earth |
| 411 | 4x6 sq.mm + 2x6 sq.mm earth |
| 412 | 4x10 sq.mm + 2x6 sq.mm earth |
| 413 | 4x16 sq.mm + 2x6 sq.mm earth |
| 414 | Rewiring for light point/ fan point/ exhaust fan point/call bell point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable and 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable as earth wire in existing surface/concealed, ISI marked PVC conduit including providing connections, dismantling of existing wiring etc. as required. Note: Upto 5Mtr length from Switch board to point |
| 415 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point (without independent switch) with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable with 20mm Medium class, in surface / recessed ISI marked PVC conduit/ casing and caping, and earthing the point with 1.5 sq. mm FRLS PVC insulated, 650V, copper conductor single core cable etc. as required. Note: Upto 5 mtr length in between two adjacent points.Excluding the cost of first point |
| 416 | Fixing following size modular PVC box on surface mode as required. |
| 417 | 1 or 2 Module |
| 418 | 3 Module |
| 419 | 4 Module |
| 420 | 6 Module |
| 421 | 8 Module |
| 422 | 12 Module |
| 423 | Fixing following size modular GI box in concealed mode as required. |
| 424 | 1 or 2 Module |
| 425 | 3 Module |
| 426 | 4 Module |
| 427 | 6 Module |
| 428 | 8 Module |
| 429 | 12 Module |
| 430 | Fixing following size Modular Switch on existing modular switch box/cover including connections etc. as required. |
| 431 | 1 Module, 1 Way, 5/6A |
| 432 | 1 Module, 1 Way, 15/16A |
| 433 | 2 Module, 1 Way, DP, 20A with indication |
| 434 | 2 Module, 1 Way, DP, 32A with indication |
| 435 | Fixing following size Modular Socket on existing modular switch box/cover including connections etc. as required. |
| 436 | 2 Module, 5 Pin, 6A |
| 437 | 2 Module, 3 Pin, 6/16A |
| 438 | 2 Module, 3 Pin, 25A |
| 439 | Fixing of 100 Watt stepped electronic fan regulator (2M) on the existing box/cover including connections etc. as required. |
| 440 | Fixing modular blanking plate on the existing modular switch box excluding modular plate as required. |
| 441 | 1 Module |
| 442 | 2 Module |
| 443 | Fixing following Modular base & cover plate on existing modular PVC/GI box. |
| 444 | 1 Module |
| 445 | 2 Module |
| 446 | 3 Module |
| 447 | 4 Module |
| 448 | 6 Module |
| 449 | 8 Module |
| 450 | 12 Module |
| 451 | Fixing suitable size PVC/GI modular box with modular plate, cover, providing and fixing one number of 3 pin 5/6 A modular socket outlet (2M) and one number of 5/6 A modular switch (1M), including providing connections etc. as required. |
| 452 | Surface Mode |
| 453 | Concealed Mode |
| 454 | Fixing suitable size PVC /GI modular box with modular plate,cover, providing and fixing one number of 15/16 A modular socket outlet (2M) and one number of 15/16 A modular switch (1M). Including providing connections etc. as required |
| 455 | Surface Mode |
| 456 | Concealed Mode |
| 457 | Fixing suitable size Gl/PVC box with modular plate, cover, providng and fixing 2 Nos. 3 pin 5/6 A modular socket outlets (2M) and 2 Nos. 5/6 A modular switches (1M), including providing connection etc. as required. |
| 458 | Surface Mode |
| 459 | Concealed Mode |
| 460 | Fixing suitable size Gl/PVC box with modular plate, cover, providng and fixing 3 Nos. 3 pin 5/6 A modular socket outlets (2M) and 2 Nos. 5/6 A modular switches (1M) including providing connection etc. as required - Computer point |
| 461 | Surface Mode |
| 462 | Concealed Mode |
| 463 | Fixing of suitable size GI/PVC boxes with modular plates, covers, 20/25A modular socket outlet (2M), 20/25 A Double pole modular one way switch (2M) at indipendent position excluding wiring-AC PointNote: Switch and socket shall be provided at independent location |
| 464 | Surface Mode |
| 465 | Concealed Mode |
| 466 | DISTRIBUTION BOARDS AND SWITCH GEARS (MCCB, MCB, RCCB) |
| 467 | Fixing following way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator). |
| 468 | 4 way |
| 469 | 8 way |
| 470 | 12 way |
| 471 | Fixing following way, single pole and neutral (SPN), sheet steel, 230V MCB double door distribution board on concealed mode complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator). |
| 472 | 4 way |
| 473 | 8 way |
| 474 | 12 way |
| 475 | Fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB double door distribution board , 415 V, on surface complete with 100A fully insulated tinned copper bus bar, srouded neutral bar, earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator). |
| 476 | 4 way(8 + 12 ) |
| 477 | 6 way (8 + 18 ) |
| 478 | 8 way (8 + 24 ) |
| 479 | 12 way (8 + 36) |
| 480 | 16 way (8 + 48 ) |
| 481 | Fixing following way, horizontal type three phase and neutral (TPN), sheet steel, 415 V MCB double door distribution board on concealed mode, complete with 100A fully insulated tinned copper bus bar, srouded neutral bar earth bar, interconnections, powder coated including earthing etc. as required. (without MCB/ RCCB/ Isolator). |
| 482 | 4 way(8 + 12 ) |
| 483 | 6 way (8 + 18 ) |
| 484 | 8 way (8 + 24 ) |
| 485 | 12 way (8 + 36) |
| 486 | 16 way (8 + 48 ) |
| 487 | Fixing following way, vertical type three phase and neutral (VTPN), sheet steel, 415V MCB double door distribution board on surface with dust protected,duly powder coated, inclusive of 100 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(without MCB and incomer) |
| 488 | 4 way (8 + 12 ) |
| 489 | 8 way (8 + 24 ) |
| 490 | 12 way (8 + 36 ) |
| 491 | Fixing following way, vertical type three phase and neutral (VTPN) , sheet steel, 415 V, MCB double door distribution board on concealed mode, dust protected, duly powder coated, inclusive of 100 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(without MCB and incomer) |
| 492 | 4 way (8 + 12 ) |
| 493 | 8 way (8 + 24 ) |
| 494 | 12 way (8 + 36 ) |
| 495 | Fixing following way, vertical type three phase and neutral (VTPN), sheet steel, 415 V, MCCB double door distribution board on surface mode, dust protected, duly powder coated, inclusive of 160 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(125/160A MCCB incomer type without MCB and incomer) |
| 496 | 4 way (MCCB +3 x 4) |
| 497 | 8 way (MCCB +3 x 8) |
| 498 | 12 way (MCCB +3 x 12) |
| 499 | Fixing following way, vertical type three phase and neutral (VTPN) , sheet steel, 415 V, MCCB double door distribution board on concealed mode, dust protected, duly powder coated, inclusive of 160 A tinned copper bus bar for each phase, 2 nos. of common neutral link, 2 nos. of earth bar, din bar for mounting MCBs as required.(125/160A MCCB incomer type without MCB and incomer) |
| 500 | 4 way (MCCB +3 x 4) |
| 501 | 8 way (MCCB +3 x 8) |
| 502 | 12 way (MCCB +3 x 12) |
| 503 | Fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 504 | Fixing cable end box (IP 43) suitable for following Single Phase and neutral (SPN) MCB DB on surface. |
| 505 | For 4 Way SPN DB |
| 506 | For 8 Way SPN DB |
| 507 | For 12 Way SPN DB |
| 508 | Fixing cable end box (IP 43) suitable for following Single Phase and neutral (SPN) MCB DB in concealed mode. |
| 509 | For 4 Way SPN DB |
| 510 | For 8 Way SPN DB |
| 511 | For 12 Way SPN DB |
| 512 | Fixing cable end box (IP 43) suitable for following TPN MCB DB on surface. |
| 513 | For 4 Way TPN DB |
| 514 | For 8 Way TPN DB |
| 515 | For 12 Way TPN DB |
| 516 | For 16 Way TPN DB |
| 517 | Fixing cable end box (IP 43) suitable for following TPN MCB DB in concealed mode. |
| 518 | For 4 Way TPN DB |
| 519 | For 8 Way TPN DB |
| 520 | For 12 Way TPN DB |
| 521 | For 16 Way TPN DB |
| 522 | Fixing cable end box (IP 43) suitable for three phase and neutral, Vertical (VTPN) MCB DB. |
| 523 | Surface Mode |
| 524 | Concealed Mode |
| 525 | Fixing cable end box (IP 43) suitable for three phase and neutral, Vertical (VTPN) MCCB DB. |
| 526 | Surface Mode |
| 527 | Concealed Mode |
| 528 | Fixing of sheet steel enclosure for DP/TP/FP MCB complete with connections, testing and commissioning etc. as required. |
| 529 | Surface Mode |
| 530 | Concealed Mode |
| 531 | Fixing following rating and breaking capacity 3 Pole MCCB with Microprocessor based LSIG (Over load, Short circuit, Instantanious and Ground fault) release, Ics=100% Icu, Ue= 415VAC, in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 532 | 63A, 36 kA |
| 533 | 125A, 36 kA |
| 534 | 250A, 36 kA |
| 535 | 400A, 36 kA |
| 536 | 630A, 50 kA |
| 537 | Fixing following rating and breaking capacity 4 Pole MCCB with Microprocessor based LSIG (Over load, Short circuit, Instantanious and Ground fault) release, Ics=100% Icu,Ue= 415VAC, in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. |
| 538 | 125A, 36 kA |
| 539 | 125A, 36 kA |
| 540 | 250A, 36 kA |
| 541 | 400A, 36 kA |
| 542 | 630A, 50 kA |
| 543 | Fixing 6/10/16/20/25/32A rating, 240/ 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 544 | Single Pole |
| 545 | Double Pole |
| 546 | Three Pole |
| 547 | Four Pole |
| 548 | Fixing 40/50/63A rating, 240/ 415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 549 | Single Pole |
| 550 | Double Pole |
| 551 | Three Pole |
| 552 | Four Pole |
| 553 | Fixing following rating, double pole (single phase and neutral), 240 V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 554 | 100 A |
| 555 | Fixing following rating, double pole (single phase and neutral), 240 V, RCCB, having a sensitivity current of 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 556 | 100 A |
| 557 | Fixing following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 558 | 100 A |
| 559 | Fixing following rating, four pole (three phase and neutral), 415V, RCCB, having a sensitivity current of 100 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make: DX³ of Legrand/Acti 9 of Schneider/Exora of L&T/Equivalent Siemens |
| 560 | 100 A |
| 561 | Fixing Digital Astronomical time switch, 2M, din rail mount (suitable for MCB DB), 24Hrs, LCD with background lighting, 10A 1SPDT/2SPDT contact, 230VAC, 1phase, Automatic Summer/winter, ROM storage. |
| 562 | One channel |
| 563 | Two channel |
| 564 | Fixing of FN Open Execution (Suitable for cylindrical/DIN fuse link)No. of poles : TPN/FP, Icu : 25kA/36kA/50kA, Ics : 100%, Ue : 415V AC 50Hz, Ui:690V, Uimp : 8kV |
| 565 | Fixing of FN inSS EnclosureNo. of poles : TPN/FP, Icu : 25kA/36kA/50kA, Ics : 100%, Ue : 415V AC 50Hz,Ui:690V, Uimp : 8kV |
| 566 | Junction Box, Material : Polycarbonate, IP 66 of following sizes for 3 phase power supply including connector as required |
| 567 | 1.5 - 4 sq.mm (130 x 180 x 77 Approx.) |
| 568 | 4 - 10 sq.mm (155 x 210 x 92 Approx) |
| 569 | LIGHT FITTINGS, FANS AND AIR CONDITIONING UNITS |
| 570 | Installation of 18/20W, 1700-2100 lumen output, 230V AC, single phase, 50 Hz, IP 20, 1200 mm length T8 LED tube with extruded aluminium/ polycarbonate body, inbuilt driver complete with pre wired, CRCA batten etc. as required. 18-20W LED/ CRCA batten |
| 571 | Installation of surface mounted 1700-2100 lumen output, 230V AC, single phase, 50 Hz, 1200 mm length, T5 LED tube integral light fittings with extruded plastic body complete accessories including inbuilt LED drive, LED tube etc. as required. |
| 572 | 18-20W 4F/1200mm |
| 573 | 8-10W 2F/600mm |
| 574 | Installation of Integral LED street light luminaries, 230VAC, 1Ф, 50Hz comprising of epoxy power coated hsg, enclosed with glass cover in frame. Suitable for 50mm OD pipe, Ingress Protection IP66, luminus efficiency>= 135 lm/Watt, integral driver, inbuilt surge suppressor of 10 kV or above with complete accessories as required. Two year on site OEM warranty shall be provided at the time of delivery. |
| 575 | 45W LED for 5m height |
| 576 | 70-80W LED for 5m height |
| 577 | 90W LED for 12m height |
| 578 | 120W LED for 12m height |
| 579 | 150W LED for 12m height |
| 580 | 200W LED for 12m height |
| 581 | Installation of LED high bay luminaires 230VAC, 1Ф, 50Hz with integral driver, frame, totally enclosed aluminium PDC housing, toughened glass, Ingress Protection IP66, luminus efficiency ≥140 lm/Watt, round type, integral driver with complete accessories as required. Two year on site OEM warranty shall be provided at the time of delivery. |
| 582 | Installation of LED Flood light luminaires 230VAC, 1Ф, 50Hz comprising of epoxy power coated with IP 66 protection, PDC housing, heat resistant toughened glass, luminus efficiency >=140 lm/Watt, integral driver with complete accessories as required. |
| 583 | 70-80W |
| 584 | 100-120W |
| 585 | 150-160W |
| 586 | 190-200W |
| 587 | 320-350W |
| 588 | Installation of 30W LED Wellglass luminaires 230VAC, 1Ф, 50Hz with IP 66 protection, Luminaire efficacy ≥140Lm/Watt, complete accessories as required. |
| 589 | Installation of LED flameproof batten with T8 LED Tube, 18/20W for Gas/Vapor group of IIA & IIB and Zone 1 & 2. IP66 Protected. Test certificates and two year warranty certificate of the light fittings should be submitted at the time of delivery. |
| 590 | Installation of 70W LED flameproof Wellglass For Gas/Vapor group of IIA , IIB & IIC and Zone 1 & 2. IP66 Protected. Test certificates and two year warranty certificate of the light fittings should be submitted at the time of delivery. |
| 591 | Installation of 230VAC, 1Ø, LED modular surface/recess round/square Panel/Down light fitting with supporting bracket/chain complete accessories as required. |
| 592 | 6-10W |
| 593 | 12-15W |
| 594 | Installation of LED mirror light fitting with supporting bracket as required. |
| 595 | 9-14W |
| 596 | 15-18W |
| 597 | Installation of 600X600 mm, 230VAC, 1Ø, 36-40W LED light fitting with supporting brackets and chain as required. |
| 598 | Installation of Lightweight ,Sleek ,Aluminium & high Performance batten (20W) with Opal diffuser which provides smooth light distribution having Inbuilt occupancy sensor. Upto 10 mtr (Diameter) sensor coverage area. Mounting Height – upto10ft. 30% light output in case of non-occupancy. Suitable for surface mounting application. |
| 599 | Installation of Ceiling fan BLDC, 230V, 50Hz , 5 star rating complete accessories as required.1200 mm sweep, 28- 35 W |
| 600 | Installation of BLDC wall fan 230V, 50HZ, 30W, 1350-1500 rpm, 65-75 CMM, 45-57dB noise level, variable speed with ocsillation complete accessories as required. |
| 601 | 400 mm wall fan |
| 602 | Installation of BLDC exhaust fan shutter type, 230V, 50HZ, 13W/20W, 2000 rpm, low noise level, automatic shutter complete accessories as required. |
| 603 | 150mm sweep |
| 604 | 200mm sweep |
| 605 | Installation of exhaust fan shutter type, 230V, 50HZ, 20-30W/30-40W/30-40W, 1300 rpm, 250/500/850 CMM, 30-40db noise level, automatic shutter complete accessories as required. |
| 606 | 250mm sweep |
| 607 | Installation of exhaust fan -LD/HD, 230V, 50HZ, 40-60W/75-95W/75-100W, 1300 rpm, 1000/1900 CMM, 40-45db noise level, bird screen protection complete accessories as required. |
| 608 | 300 LD |
| 609 | 300 HD |
| 610 | Installation of BLDC Pedestal fan 400mm Sweep, variable speed with Oscillation, 230V, 50HZ, 35W, 76 CM/M Air Delivery complete accessories as required. |
| 611 | Installation of Pedestal fan, variable speed with Oscillation, 230V, 50HZ, 100-120W/150-160W, 90/145 CM/M Air Delivery complete accessories as required. |
| 612 | Pedestal type 450mm sweep |
| 613 | Installation of industrial Air circulator with Oscillation, 230V, 50HZ, 3 Speed, 80-95W/175-185W, 150/280CMM complete accessories as required. |
| 614 | Wall mounted type 450mm sweep |
| 615 | Wall mounted type 600mm sweep |
| 616 | Pedestal type 450mm sweep |
| 617 | Pedestal type 600mm sweep |
| 618 | Installation of Voltage Stabilizer, Wall mounting, 230VAC, 1Phase, 50Hz. |
| 619 | Installation of 2HP/3HP/5HP DOL Motor Starters, 3Ø, 415V,50Hz, Overload Relay Range -2.4 to 9.3A, Contactor Type-C00N, Contactor Rating (AC-3)-16A |
| 620 | Installation of 2HP/3HP/5HP Fully Automatic Star Delta Starter with NHD Contactor & Pneumatic Timers of following range, 3Ø, 415V,50Hz, Overload Relay Range -6A to 24A, Contactor Type-C00N, Contactor Rating (AC-3)-16A-25A |
| 621 | 10HP/15HP |
| 622 | LAYING OF LT CABLE |
| 623 | Laying and fixing of one run PVC insulated and PVC sheathed/ XLPE power cable of 1.1 kV grade of following size through metal /HUME pipe including excavation, laying of pipe and refilling the trench etc. as required . Required pipe will be supplied by CSL. |
| 624 | Upto 35 sq. mm |
| 625 | Above 35 sq. mm and upto 95 sq. mm |
| 626 | Above 95 sq. mm and upto 185 sq. mm |
| 627 | Above 185 sq. mm and upto 400 sq. mm |
| 628 | Laying and fixing of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size through the trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 629 | Upto 35 sq. mm |
| 630 | Above 35 sq. mm and upto 95 sq. mm |
| 631 | Above 95 sq. mm and upto 185 sq. mm |
| 632 | Above 185 sq. mm and upto 400 sq. mm |
| 633 | Laying and fixing of one run Aluminium/Copper Conductor, XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type Outer Sheathed power cable of 1.1 kV grade of following size in the existing RCC/ HUME/ METAL pipe as required. |
| 634 | Upto 35 sq. mm |
| 635 | Above 35 sq. mm and upto 95 sq. mm |
| 636 | Above 95 sq. mm and upto 185 sq. mm |
| 637 | Above 185 sq. mm and upto 400 sq. mm |
| 638 | Laying and fixing of one run Aluminium/Copper Conductor, XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type Outer Sheathed power cable of 1.1 kV grade of following size in the existing masonry cable trench as required. |
| 639 | Upto 35 sq. mm |
| 640 | Above 35 sq. mm and upto 95 sq. mm |
| 641 | Above 95 sq. mm and upto 185 sq. mm |
| 642 | Above 185 sq. mm and upto 400 sq. mm |
| 643 | Laying and fixing of one run Aluminium/Copper Conductor, XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type Outer Sheathed power cable of 1.1 kV grade of following size on wall surface as required (including supply of GI saddle/ M.S flat clamp, iron screw, fastener). |
| 644 | Upto 35 sq. mm |
| 645 | Above 35 sq. mm and upto 95 sq. mm |
| 646 | Above 95 sq. mm and upto 185 sq. mm |
| 647 | Above 185 sq. mm and upto 400 sq. mm |
| 648 | Laying and fixing of one run Aluminium/Copper Conductor, XLPE Insulated, Thermoplastic Tape Inner Sheathed, Armoured and Extruded PVC Type Outer Sheathed power cable of 1.1 kV grade of following size on existing cable tray as required (including supply of GI saddle/ M.S flat clamp, bolt & nut). |
| 649 | Upto 35 sq. mm |
| 650 | Above 35 sq. mm and upto 95 sq. mm |
| 651 | Above 95 sq. mm and upto 185 sq. mm |
| 652 | Above 185 sq. mm and upto 400 sq. mm |
| 653 | Laying of stranted copper conductor, XLPE/PVC insulated, core laid up, PVC tape/ PVC extruded innersheathed for 3/4 core, unarmoured flexible copper cable. |
| 654 | Upto 35 sq. mm |
| 655 | HT CABLE - LAYING |
| 656 | Laying of stranded compact circular Aluminium conductor, conductor screened with extruded semi conducting component, XLPE insulated, insulation screened with extruded semi conducting component in combination with copper tape, Aluminium flat strip/ round wire armoured, and overall PVC ST2 sheathed 11 kV grade three core HT cable of following size in the existing RCC/HUME/METAL pipe as required. (conforming to IS:7098 part II 2011) |
| 657 | 95 Sq.mm |
| 658 | 120 Sq. mm |
| 659 | 150 Sq. mm |
| 660 | 185 Sq.mm |
| 661 | 240 Sq.mm |
| 662 | 300 Sq. mm |
| 663 | 400 Sq.mm |
| 664 | LT CABLE JOINTING AND END TERMINATION |
| 665 | Making end termination with brass single compression gland and Heavy duty Aluminium long barrel lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 kV grade as required.( Including supply of gland and lugs as required ) |
| 666 | 3x6 sq. mm (19mm) |
| 667 | 3x10 sq. mm (22mm) |
| 668 | 3x16 sq. mm (25mm) |
| 669 | 3x25 sq. mm (25mm) |
| 670 | 3x35 sq. mm (28mm) |
| 671 | 3x50 sq. mm (32mm) |
| 672 | 3x120 sq. mm (45mm) |
| 673 | 3x240 sq. mm (50mm) |
| 674 | 3x300 sq. mm (57mm) |
| 675 | 3x400 sq. mm (63mm) |
| 676 | 3.5 X 25 sq. mm (28mm) |
| 677 | 3.5 X 35 sq. mm (32mm) |
| 678 | 3.5 X 50 sq. mm (35mm) |
| 679 | 3.5 X 70 sq. mm (38mm) |
| 680 | 3.5 X 95 sq. mm (45mm) |
| 681 | 3.5 X 120 sq. mm (45mm) |
| 682 | 3.5 X 150 sq. mm (50mm) |
| 683 | 3.5 X 185 sq. mm (57mm) |
| 684 | 3.5 X 240 sq. mm (62mm) |
| 685 | 3.5 X 300 sq. mm (70mm) |
| 686 | 3.5 X 400 sq. mm (82mm) |
| 687 | 4 X 10 sq. mm (25mm) |
| 688 | 4 X 16 sq. mm (28mm) |
| 689 | 4 X 25 sq. mm (28mm) |
| 690 | 4 X 35 sq. mm (32mm) |
| 691 | 4 X 50 sq. mm (35mm) |
| 692 | Making end termination with brass single compression gland and heavy duty tinned copper long barrel lugs for following size of copper conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required.( Including supply of gland and lugs as required ) |
| 693 | 3x4 sq. mm (19mm) |
| 694 | 3x6 sq. mm (19mm) |
| 695 | 3x10 sq. mm (22mm) |
| 696 | 3x240 sq. mm (50mm) |
| 697 | 3x300 sq. mm (57mm) |
| 698 | 3x400 sq. mm (63mm) |
| 699 | 3.5x25 sq. mm (28mm) |
| 700 | 3.5x35 sq. mm (32mm) |
| 701 | 3.5x50 sq. mm (35mm) |
| 702 | 3.5x70 sq. mm (38mm) |
| 703 | 3.5x95 sq. mm (45mm) |
| 704 | 3.5x120 sq. mm (45mm) |
| 705 | 3.5x150 sq. mm (50mm) |
| 706 | 3.5x185 sq. mm (57mm) |
| 707 | 3.5x240 sq. mm (63mm) |
| 708 | 3.5x300 sq. mm (63mm) |
| 709 | 3.5x400 sq. mm (70mm) |
| 710 | 4 X 2.5 sq. mm (19mm) |
| 711 | 4 X 4 sq. mm (22mm) |
| 712 | 4 X 6 sq. mm (22mm) |
| 713 | 4 X 10 sq. mm (25mm) |
| 714 | 4 X 16 sq. mm (25mm) |
| 715 | 4 X 25 sq. mm (28mm) |
| 716 | 4 X 35 sq. mm (32mm) |
| 717 | 4 X 50 sq. mm (35mm) |
| 718 | Making indoor/outdoor straight through cable joint with heat shrinkable cable jointing kit including heavy duty aluminium long barrel lugs and other end termination materials for following size of aluminium conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 1.1 kV grade as required. |
| 719 | 3/4 Core 16 sq. mm |
| 720 | 3/3.5/4 Core 25 sq. mm to 3/3.5 Core 50 sq. mm |
| 721 | 4 Core 35 sq. mm to 4 Core 50 sq. mm |
| 722 | 3/3.5 Core 70 sq. mm |
| 723 | 3/3.5 Core 95 sq. mm |
| 724 | 3/3.5 Core 120 sq. mm to 3/3.5 Core 185 sq.mm |
| 725 | 3/3.5 Core 240 sq. mm |
| 726 | 3/3.5 Core 300 sq. mm |
| 727 | 3.5 Core 400 sq. mm |
| 728 | HT CABLE JOINTING AND END TERMINATION |
| 729 | Making indoor/outdoor straight through cable joint with heat shrinkable cable jointing kit including heavy duty aluminium long barrel lugs and other end termination materials for following size of aluminium conductor, XLPE insulated, thermoplastic tape inner sheathed, armoured and PVC outer sheathed cables of 11 kV grade as required. |
| 730 | 3 Core 120 sq. mm |
| 731 | 3 Core 240 sq.mm to 3 Core 300 sq.mm |
| 732 | EARTHING |
| 733 | Earthing with copper earth plate 600 x 600 x 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2. 7 meter long etc. with charcoal/ coke and salt as required.(Details of cost for one each) |
| 734 | Maintenance free Earthing -Providing and fixing of maintenance free Earthing system comprises of molecularly bonded copper of 99.9% purity on low carbon steel of 3m length , having a diameter of 20mm with copper bonding thickness of 250 microns with with fault current withstand capability of 20 KA rms value for 1 second and I peak of 50 KA. Universal Clamp should be exothermic moulded along with earth rod. Earth enhancing mineral compound is used for improving the soil conductivity. The material shall be mineral inert to sub soil and shall not pollute the environment and non corrosive to earth rod. The material should have a resistivity less than 0.2 Ωm. It should be free from hazardous substances The mineral compound is required to have minimum 20 Kg of the total composite. If using chemical compound min 37.5 Kg is required. Polypropylene & Polyethylene Earth electrode inspection chamber with heavy duty cover should be used to cover the Earth Rod. The dimension shall be 170mmx 170mmx 170mm with a weight bearing capacity of 50KN. |
| 735 | Laying 6 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 736 | Laying 8 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 737 | Laying 10 SWG Copper wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 738 | Laying 12 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 739 | Laying 14 SWG Cu. wire at 0.50 meter below ground level / surface for conductor earth electrode, including connection/ termination with Cu. Lug etc. as required. |
| 740 | Fixing 32x6 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 741 | Fixing 25x6 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 742 | Fixing 25x3 mm Copper strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 743 | Fixing 32x6 mm GI strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 744 | Fixing 50x6 mm GI strip at 0.50 meter below ground level / surface from earth electrode, including connection/ terminating with S.S nut, bolt, spring washer, excavation and re-filling etc. as required. |
| 745 | Laying copper bonded steel solid round conductor 10mm diameter having 78 sqmm cross sectional area from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 25x3 mm solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. Needs to be installed 0.5 meter from earth. |
| 746 | Laying copper bonded steel solid tape conductor 16mm diameter having 200Sq mm cross sectional area (if required 300Sqmm then 2 runs has to be considered) from earth electrode directly in ground as required. copper coated steel, high corrosion resistant (if pure copper conductor 32x6 solid tape also can be used). Meets the requirement of (IS/IEC 62305) copper coating thickness of 100microns Should be tested and use exclusively for lightning protection earthing system and ring equipotential bonding. Needs to be installed 0.5 meter from earth. |
| 747 | MISCELLANEOUS ITEMS |
| 748 | Capacitor of ceiling fan / exhaust fan / pedestal fan / wall fan etc |
| 749 | Panel board painting |
| 750 | Steel work for panel maintenance |
| 751 | GI pipe as par IS/1239 ISI Marked C Class (heavy) |
| 752 | 32 mm dia G.I. Pipe |
| 753 | 50 mm dia G.I. Pipe |
| 754 | 80 mm dia G.I. Pipe |
| 755 | 100 mm dia G.I. Pipe |
| 756 | GI pipe as par IS/1239 ISI Marked C Class (heavy) |
| 757 | 32 mm dia G.I. Pipe |
| 758 | 50 mm dia G.I. Pipe |
| 759 | 80 mm dia G.I. Pipe |
| 760 | Installation of cable ladder (aluminium) with all accessories as per technical specificationSpan: 300mmWidth: 300mmMaterial: Aluminium channel and Aluminium rod |
| 761 | Fixing of extra down rod of 19mm dia heavy gauge including painting etc. as required for ceiling fan |
| 762 | Installation, testing and commissioning of ceiling fan, including removal and dismantiling of existing fan, wiring the down rods of standard length (upto 30 cm) with 2x1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and 1x1.5 sq. mm FRLS PVC insulated copper conductor single core cable (Green) as earth etc. as required. |
| 763 | Checking, cleaning and refitting/dismantling of existing fans |
| 764 | Checking, cleaning and refitting/dismantling of existing fans including supply and replacement of nut& bolt, lock pins, bush of ceiling fan |
| 765 | Painting of ceiling fan with one or more coats of spray painting with synthetic enamel paint of approved brand and manufacture to give an even shade. |
| 766 | Providing stainless steel fan hooks on the ceiling by chipping and grouting |
| 767 | Checking and rectifying the defects in circuits, changing fuse base, carrier, connectors etc. in junction boxes / terminal boxes of streetlights. |
| 768 | Cleaning of cable trenches |
| 769 | Labour charge for an electrician |
| 770 | Labour charge for a helper Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 04, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 17 daysAug 05, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 18 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender