Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56504438

Tender For Repair / Maintenance And Replacement Of Lt Panels, Lt Cables, Lt Distribution System, Bus Bar Chamber, Mccb, Acb, Change Over Switch, Earthing At Kabul Line, Baird Place, Kotwali Line, Cedz Office, Cda (Army) And Associated Area Of Age (Sl

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
49 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
16 days left
EMD
98000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance And Replacement Of Lt Panels, Lt Cables, Lt Distribution System, Bus Bar Chamber, Mccb, Acb, Change Over Switch, Earthing At Kabul Line, Baird Place, Kotwali Line, Cedz Office, Cda (Army) And Associated Area Of Age (Sldc) E/S Under Ge (U) Elect Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR / MAINTENANCE AND REPLACEMENT OF LT PANELS, LT CABLES, LT DISTRIBUTION SYSTEM, BUS BAR CHAMBER, MCCB, ACB, CHANGE OVER SWITCH, EARTHING AT KABUL LINE, BAIRD PLACE, KOTWALI LINE, CEDZ OFFICE, CDA (ARMY) AND ASSOCIATED AREA OF AGE (SLDC) E/S UNDER GE (U) ELECT SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Material and labour for excavation in trenches not exc. 1.5 m wide and not exc 1.5 mtr deep in soft loose soil for laying / taking up/ taking down of cables and getting out and leveling of bottom surface to required level complete all as specified and directed by Engineer- in- Charge.
2Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables and in substation ducts for cushioning of cables etc, complete all as specified and directed by Engineer- in- Charge. (Note -Measurement should be after punning down)
3S & F sub class B bricks having minimum compressive strength 75 Kg/ Sq cm laid in trenches for cable protection etccomplete all as specified and directed by Engineer- in- Charge.
4Material and labour for returning filling in, including spreading, levelling, watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by Engineer- in- Charge.
5Material and labour for removing excavated material (ie soil) from site to a distance n. exc 50 m away and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed by Engineer- in- Charge.
6Material and labour for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by Engineer- in- Charge.
7Supply and laying of GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size 80 mm dia complete all as specified and directed by Engineer- in- Charge.
8All as per item No 7.00 above but of size 50 mm dia complete all as specified and directed by Engineer- in- Charge.
9All as per item No 7.00 above but of size 40 mm dia complete all as specified and directed by Engineer- in- Charge.
10Supply, installation, testing and commissioning in replacement of factory made tested LT panel board of size not less than 1.4 mtr x 0.55 mtr x 1.6 mtr cubical double door compartment outdoor type leg mounted suitable for , 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating not less than 1.5 times of Incomer/ Outgoings MCCBs, installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 2.0 mm, 40X40X6 mm thick MS angle iron frame work, fixing of double doors shall be on MS hinges with anti-theft provision (the door can’t be removed from enclosure without cutting enclosure), powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated multisranded copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 2.5 sqmm) and comprising of the following including necessary brick work for platform of suitable size:- INCOMING :- (i) MCCB 4 pole, 400 Amps Thermal Magnetic and Adjustable type, 50 Hz, 415 Volts, 36 KA -1 No OUTGOING :- (i) MCCB 4 pole, 200 Amps, 50 Hz, 415 Volts, 25KA Adjustable Thermal and Adjustable Magnetic setting- 10 Nos (ii) Digital Voltmeter 0-500 V-01 No with selector switch (iii) Digital Ammeter with selector switch 300 Amps including suitable CT-01 Set (iv) LED Indicator lamp-1 set (1) Panel wiring complete with copper cable of suitable rating and size.
11All as item no-10.00 above (here in before) but as followings:-Panel size should not be less than 1.6 mtr x 0.55 mtr x 1.6 mtrINCOMING:- (i) MCCB 4 pole,400 Amps Thermal Magnetic and Adjustable type, 50 Hz, 415 Volts, 36 KA -1 No OUTGOING:- (i) On load change over switch of capacity 400 Amps, four pole, 415 volts, AC, 50 Hz - 01 No . (ii) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 25KA Adjustable Thermal and Adjustable Magnetic setting- 7 Nos (iii) Digital Voltmeter 0-500 V-01 No with selector switch (iv) Digital Ammeter with selector switch 300 Amps including suitable CT-01 Set (v) LED Indicator lamp-1 set (1) Panel wiring complete with copper cable of suitable rating and size.
12All as item no-10.00 above (here in before) but as followings:-Panel size should not be less than 1.6 mtr x 0.55 mtr x 1.6 mtrINCOMING:- (i) MCCB 4 pole, 400 Amps Thermal Magnetic and Adjustable type, 50 Hz, 415 Volts, 36 KA -1 No OUTGOING:- ii) MCCB 4 pole, 160 Amps, 50 Hz, 415 Volts, 25KA Adjustable Thermal and Adjustable Magnetic setting- 6 Nos (iii) Digital Voltmeter 0-500 V-01 No with selector switch (iv) Digital Ammeter with selector switch 300 Amps including suitable CT-01 Set (v) LED Indicator lamp-1 set (1) Panel wiring complete with copper cable of suitable rating and size.
13Supply, installation, testing and commissioning in replacement of factory made tested LT panel board cubical double door compartment outdoor type plate mounted suitable for 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating 1000 Amp installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 1.6mm, 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- INCOMING:- (i) ACB 4 pole, 1000 Amps Micro processor release manual drawout Adjustable type, 50 Hz, 415 Volts, 50 KA -1 No (ii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No (iii) Ammeter 0-800 Amp digital type with 3 way rotary selector switch - 01 No (iv) CT ratio 800/5 Amp class-1 ISI marked - 01 Set of three (v) Indicating lamp one set of three OUTGOINGS:- (i) MCCB 4 pole, 400 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting - 02 Nos (ii) MCCB 4 pole, 320 Amps, 50 Hz, 415 Volts, 35 KA Adjustable Thermal and Fixed Magnetic setting - 04 Nos Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimbles. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture.
14Supply, installation, testing and commissioning in replacement of factory made tested LT panel board cubical double door compartment outdoor type plate mounted suitable for 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating 1000 Amp installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 1.6mm, 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- INCOMING:- (i) ACB 4 pole, 1000 Amps Micro processor release manual drawout Adjustable type, 50 Hz, 415 Volts, 50 KA -1 No (ii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No (iii) Ammeter 0-800 Amp digital type with 3 way rotary selector switch - 01 No (iv) CT ratio 800/5 Amp class-1 ISI marked - 01 Set of three (v) Indicating lamp one set of three OUTGOINGS:- (i) MCCB 4 pole, 400 Amps, 50 Hz, 415 Volts, 35 KA Adjustable Thermal and Fixed Magnetic setting - 01 No (ii) MCCB 4 pole, 250 Amps, 50 Hz, 415 Volts, 35 KA Adjustable Thermal and Fixed Magnetic setting - 04 Nos Note: (i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimbles. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture.
15Supply, installation, testing and commissioning in replacement of factory made tested LT panel board cubical double door compartment outdoor type plate mounted suitable for , 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating 1000 Amp installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 1.6mm, 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- INCOMING:- (i) ACB 4 pole, 630 Amps Micro processor release manual drawout Adjustable type, 50 Hz, 415 Volts, 50 KA -1 No (ii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No (iii) Ammeter 0-800 Amp digital type with 3 way rotary selector switch - 01 No (iv) CT ratio 800/5 Amp class-1 ISI marked - 01 Set of three (v) Indicating lamp one set of three OUTGOINGS:- (i) MCCB 4 pole, 200 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 08 Nos (ii) MCCB 4 pole, 320 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 01 No Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Please Enable Macros to View BoQ information
16Supply, installation, testing and commissioning in replacement of factory made tested LT panel board cubical double door compartment outdoor type plate mounted suitable for , 415 volts 3 phase, 4 wire, 50 HZ AC supply system having bus bar chamber with insulated Aluminium bus bar of rating 1000 Amp installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and inner compartment 1.6mm, 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable IS 694 marked , 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size:- INCOMING:- (i) ACB 4 pole, 630 Amps Micro processor release manual drawout Adjustable type, 50 Hz, 415 Volts, 50 KA -1 No (ii) Voltmeter 0-500 V digital type with 3 way rotary selector switch - 01 No (iii) Ammeter 0-800 Amp digital type with 3 way rotary selector switch - 01 No (iv) CT ratio 800/5 Amp class-1 ISI marked - 01 Set of three (v) Indicating lamp one set of three OUTGOINGS:- (i) MCCB 4 pole, 200 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 08 Nos (ii) MCCB 4 pole, 320 Amps, 50 Hz, 415 Volts, 36 KA Adjustable Thermal and Adjustable Magnetic setting- 01 No Note:(i) All incoming and outgoing feeder shall be connected by cable through suitable size glands & thimples. (ii) The various feeders shall be indicated by 50mm size letters in synthetic enamel white paint. (iii) All MCCB should be connected to Bus bar directly through expended links (iv) All MCCB with adjustable protection for over load and short circuit and conforming to IEC60947/IS 13947/Pt. II/1993 (Latest Version). The MCCB should have Ics=100% Icu. The MCCBs shall have spreader links and barriers as standard feature of manufacture. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56504438
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance And Replacement Of Lt Panels, Lt Cables, Lt Distribution System, Bus Bar Chamber, Mccb, Acb, Change Over Switch, Earthing At Kabul Line, Baird Place, Kotwali Line, Cedz Office, Cda (Army) And Associated Area Of Age (Sldc) E/S Under Ge (U) Elect Supply Delhi Cantt-10
Basic Detail
Tender No GE ELECT/TOKEN-22/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 49 Lakhs
Tender Fee 500
EMD 98000
Exemption Not Available
Document List
42f3b3c0-0b7b-4d85-af88-78ee948967d4.html
BOQ_872541.xls
TD22.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

42f3b3c0-0b7b-4d85-af88-78ee948967d4.html

xls

BOQ_872541.xls

pdf

TD22.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders