Defence Statutory Bodies & Commissions/Committees Closing in 17 days TDR #56504422

Tender For Provision Of Deficient Swimming Pool Within Hqtnp Complex At Chennai:

Issued by Statutory Bodies & Commissions/Committees · Chennai, Tamil Nadu
Tender Value
6.06 Crore
Estimated cost
Bid Submission
06 Aug 2026
17 days left
EMD
6.28 Lakhs
Bank guarantee accepted
Document Fee
3000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Chennai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Provision Of Deficient Swimming Pool Within Hqtnp Complex At Chennai:

BOQ

Name of Work:- PROVISION OF DEFICIENT SWIMMING POOL WITHIN HQTNP COMPLEX AT CHENNAI:
Sl. No. Item Description
1SCHEDULE 'A' PART-I to SCHEDULE 'A' PART-XNote: Schedule 'A' Part-I to Part-X are prepriced by MES. Bidders shall insert their lump sum amount in green coloured field under Column 6 only.
2Lump Sum price worked out by the contractor for (BUILDINGS & STRUCTURES), as listed in SCHEDULE 'A' PART-I
3Lump Sum price worked out by the contractor for 'Site Clearance/Area Development/Earth Work/Excavation', as listed in Schedule 'A' Part-II
4Lump Sum price worked out by the contractor for 'ROAD /PATH/ CULVERT', as listed in Schedule 'A' Part-III
5Lump Sum price worked out by the contractor for 'AREA DRAINAGE, as listed in Schedule 'A' Part-IV
6Lump Sum price worked out by the contractor for 'SEWAGE DISPOSAL', as listed in Schedule 'A' Part-V
7Lumpsum price worked out by the contractor for 'COMPOUND WALL CUM OUTER RCC RETAINING WALL', as listed in Schedule 'A' Part-VI
8Lump Sum price worked out by the contractor for 'EXTERNAL ELECTRIFICATION, as listed in Schedule 'A' Part-VII
9Lump Sum price worked out by the contractor for 'INTERNAL WATER SUPPLY', as listed in Schedule 'A' Part-VIII
10Lump Sum price worked out by the contractor for 'INTERNAL ELECTRIFICATION', as listed in Schedule 'A' Part-IX
11Lump Sum price worked out by the contractor for 'EXTERNAL WATER SUPPLY', as listed in Schedule 'A' Part-X
12SCHEDULE 'A' PART-XI: (MISCELLANEOUS ITEMS):
13INTERNAL ELECTRIFICATION:
14S&F LED Security light fitting with tube 35W outdoor type with high pressure die cast aluminium housing and heat resistant luminiare complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics of IP 65/ 66 pre wired with 1.5 Sq mm copper conductor cable upto connector including 2 Mtr long GI Tubing Med grade 32 mm dia bend to shape fixing on wall with suitable MS brackets compelte all as specified and as directed.
15Point wiring with 1.5 Sq.mm. FRLS PVC insulated unsheathed copper conductor single core multi stranded 1100 Volts grade, ISI marking drawn through and including non metallic PVC rigid concealed conduit and conduit accessories medium grade, ISI marked, including modular metal flush box with and including modular white cover plate with frame for mounting modular switches/sockets/fan regulators etc. including one run of 1.5 Sq.mm. PVC insulated unsheathed copper cable for earth continuity, connected to earth dolly complete all as specified and directed for One light point controlled by one switch or One fan (Ceiling fan/Exhaust fan) point controlled by one switch or One 3 Pin socket outlet 5 Amps on independent board complete all as specified and as directed.
16All as per item No. 13 here-in-before but One 3 Pin socket outlet 5 Amps on the same board complete all as specified and directed.
17All as per item No. 13 here-in-before but One light point controlled by two, 2 way switches complete all as specified and directed.
18All as per item No. 13 here-in-before but One 3 pin socket outlet 15 Amps on independent board with 2.5 Sq.mm. FRLS PVC wire and one run of 2.5 Sq.mm. copper cable for earth continuity complete all as specified and directed.
19M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 25mm dia. with accessories complete with two runs of 6 Sq.mm. cable and one run of 6 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.
20M&L sub main wiring concealed type with PVC insulated FRLS copper conductor cable unsheathed for circuit along with earth wire including PVC rigid conduit medium grade 20mm dia. with accessories complete with two runs of 4 Sq.mm. cable and one run of 4 Sq.mm. earth wire complete with colour coding and making good the disturbed area complete all as specified and as directed.Note for Item Nos.17 & 18: Two runs of cable, one run of earth wire and one run of conduit will be measured as one unit.
21S& F LED bulb in B22 base 9 watt Environment friendly (Contains no Mercury, UV/IR free light) complete all as specified and as directed.
22Supply and Fix LED fittings with decorative box type with driver, holder, of capacity 1X 20W 220 V, 4 feet including LED tube light complete with all accessories internally pre-wired and connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified and directed
23Supply and fix LED light fitting mirror type with high out put diffuser 2 feet, 1X10 W 230v, suitable for Surface, Wall mounting, decorative type with driver, holder and LED lamp and all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed .
24Supply and fix ceiling fans, complete with three blade, down rod, accessories 230V,1200mm sweep, with Squirrel cage induction motor BEE 5 star rated with downrod of suitable suitable for fixing ceiling fan at specified height from floor level.Note: Colour of the fan will be decided by Engr -in - Charge including all acessories complete all as specified and as directed.
25Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450mm sweep heavy duty with, blades, frame and louvers all as specified and as directed.
26Supply and fix of exhaust fan, steel body AC single Phase. 230V of size 300mm sweep with, blades, frame and louvers all as specified and as directed.
27M & L for earthing complete with galvanised steel earth plate electrode 60cm×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to 4 mm GI wire as earthing lead by means of bolts, nuts, check nuts and washers of copper all as shown in electrical plate No.3 in SSR part 1 connected to earthing test point,including 20 mm GI pipe (Medium grade) for watering and 15 mm GI pipe (Medium grade) for protection of earth wire and etc.. including testing on completion ,PCC chambers in PCC1:3:6 type C1, RCC M25 type cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle GI funnel & wiremesh ,funnel,lugs and charcoal,salt etc all as applicable complete all as specified and as directed by the Engineer-in-Charge.
28Supply and fix Modular metal flush box 8 module complete all as specified and directed.
29EXTERNAL WATER SUPPLY:
30Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) of outer dia 90mm and PP-R plain fittings in trenches/walls/cellings or laying in floors complete including all fittings complete all as specified and as directed.
31Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) of outer dia 110mm and PP-R plain fittings in trenches/walls/cellings or laying in floors complete including all fittings complete all as specified and as directed.
32Supply and lay 3 layer ( inner antimicrobial, outer UV stabilized) ISI marked ,IS-15801, PP-R pipes SDR 11 (PN-10) of outer dia 63mm and PP-R plain fittings in trenches/walls/cellings or laying in floors complete including all fittings complete all as specified and as directed.
33Supply and fix Strainer Y type conforming to IS, size 80 mm (3”) dia complete all as specified and as directed.
34M & L flat submersible cable of size 6 sqmm X 3 core 84/0.3 (nos of conductor & dia of wire) for connection of pump to starter including making water pump connections etc complete confirming to IS 694-2010 complete all as specified and as directed.
35Supply and fix fully automatic electronic type star delta starter panel with voltmeter and ammeter ,selector switch ON/OFF indication, 3 phase 5 HP complete with Panel complete all as specified and as directed.
36Supply and Install complete submersible pump,5HP electric driven 415 V, TP suitable for openwell including PCC foundation complete all as specified and as directed.
37Supply and fix PPR Gate Valves (Brass Insert) of 90 mm bore complete all as specified and as directed.
38Supply and fix PPR Gate Valves (Brass Insert) of 110 mm bore complete all as specified and as directed.
39Supply and fix PPR Foot valves of 63 mm bore complete all as specified and as directed.
40Supply and fix PPR Ball Valves (Brass Insert) of 63 mm bore complete all as specified and as directed.
41Supply and fix PPR Non Return Valves of 90/110 mm bore complete all as specified and as directed.
42Supply and filling of metro water in initial time through water tanker to complete 860KL as per size of pool all as specified complete all as specified and as directed.
43M&L for brick masonary valve chamber of size 600mmx600mmx600mm ( internal size) by providing PCC 1:2:8 tyepe D2 foundation 100 mm thick brick work in CM 1:4 plastering 15mm thickin CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover complete excavation and lockeing arrangement and handle including painting steel surfaces with two coats of enamel paint over a coat of red oxide primer includingdismantling the existing damaged valve chamber and removing debris away from the premises etc complete all as specified and as directed.
44M&L for brick masonary valve chamber of size 1.0mx1.0mx1.0mm ( internal size) by providing PCC 1:2:8 tyepe D2 foundation 100 mm thick brick work in CM 1:4 plastering 15mm thickin CM 1:4 internal surfaces completely and external surfaces completely and external surfaces upto 150mm below GL, 75mm thick PCC 1:2:4 type B as in coping valve chamber cover made up of 40x40x5mm thick angle iron frame and 3.15 mm thick MS sheet cover complete excavation and lockeing arrangement and handle including painting steel surfaces with two coats of enamel paint over a coat of red oxide primer including dismantling the existing damaged valve chamber and removing debris away from the premises etc complete all as specified and as directed.
45EXTERNAL ELECTRIFICATION:
46Supply and fix weather proof looping in box PVC with outside dimension 160 x160x105 mm comprising of connector and MCB SP 6-32 A including mounting arrangements and lugs etc.complete all as specified and as directed. Make :Sintex/Hensel
47Supply , installation, testing and commissioning of Indoor LT panel board , CPRI Approved , made out of CRCA sheet 2 mm thick vermin proof factory made with 40 x 40 x6 mm MS angle/channel duly painted with two coats of synthetic enamel powder coated paint over a coat of metal primer with bus bar chamber comrising of high conductivity copper bus bar of capacity 500 Amps three phase and half the capacity for neutral including voltmeter, Ammeter selector switches, PCC foundatoin suitable to accommodate the following as specied and as directed.INCOMING(a) MCCB 415 V,160 A, 4 pole with electronic release Tharmal magnetic module with over load , short circuit and earth fault protection with earth module breaking capacity 25 KA- 01 Nos.(b)Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp complete and all as per standard pratice ---1 Job
48OUT GOING(a) MCCB 63 A, 415V , 4 pole with Tharmal magnetic module ,over load short circuit protection, breaking capacity 25 KA electronic release- 03 Nos (For filteration plant panel -01 , Submersible motor panel - 02 )(b) MCCB 40 A, 415V , 4 pole with Tharmal magnetic module ,over load short circuit protection, breaking capacity 25 KA electronic release - 05 No (Changing Rooms left wing -1 Nos., Changing Rooms right wing -1 Nos. Street light -01 Nos.,Spare -02 Nos) (c) Single Phase Preventer - 2 Nos. Note :-(i) All MCCBs / instruments / MCBs /Bus Bar shall be housed in a separate housing with on- off latches in the housing and Digital Panel Meter Multifunctional type for Amps, Volts, KWH, Power Factor and other parameters flush mounting with LED indication lamp for each outgoing complete and all as per standard pratice.
49Supply and fix new GI bracket made out of 25/32/40mm dia GI pipe length 1.2 mtr long bent to an angle 135 degree including two coats of aluminium paint over a coat of zinc chromate primer along with clamps, bolts, nuts etc complete all as specified.
50Supply and fix energy efficient LED security light fitting, 20 W or nearest higher wattage, 230V, IP66, with pressure die cast aluminium housing and integral electronic driver including all accessories internally pre wired complete all as specified and as directed.
51Supply and fix of Turin LED bollard light fitting 10 W or nearest higher wattage,230v,IP 66 to ensure sustainable suitable for Surface mounting, with integrated LED driver, etc. complete with all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable base freme ring or square of min 20 cm hight to fix the light all as specified and as directed.
52Supply and fix energy saving LED street light fittings, 45 Watts or nearest higher wattage, with in-built electronic driver, IP 66 class of protection with versatile pressure die-cast aluminium housing parts, pure polyester powder coated dark gray housing, toughened glass cover with silicon gaskets and energy efficient LED 5700K including all accessories complete all as specified and as directed.
53SWIMMING POOL
54Supply install test and commissioning of Factory made Vertical cylindrical type multi grade pressure sand filter capacity minimum 80 m3 / hour made from MS sheet suitable with size 2000 mm dia for working pressure 2.5 Kg/cm2 duly painted (inner & outer) with red oxide primer and two coats of epoxy paint complete with suitable size of inlet, outlet valves,NRVs, control valves for operation, back wash system including valve manifold, drain out facilities complete including frontal piping of 150 MS suitable sizes pipes for discharge of 80 M3 /hour / pressure rating 2.5 Kgf/cm2,fittings and filtration rate of 25 m3/hr ,including initial filling of filter media, as required for smooth function and operation all as per manufacturer”s recommendations,for swimming pool of 8,00,000 ltr capacity and turn over period of 5-6 hours. Note: 1. Rate quoted shall be inclusive of all type & size of UPVC/HDPE/MS frontal piping, control valves connected to the pressure filter and PCC foundation of suitable size as per manufacturers instructions 2. Piping up to pressure filter in-let & beyond out let of pressure filter and drain pipe shall be measured and paid separately.
55Supply, install, test and commissioning of Air Blower with suitable 3 Ph motor IE-2 rated , ISI marked required for filtration unit back wash process of suitable capacity but not less than 300 Cum /Hr , or as recommended by OEM for swimming pool.
56Supply install test and commissioning of Water circulation, Horizontal split casing end suction pump 415 V, 50 Hz, 1450 RPM suitable for pressure filter designed discharge capacity 80 m3 / hour @ 25 Mtr head having pump efficiency 65-75%, and suitable for filtration plant as per Sl No 47 above for ensuring turnover period 5-6.0 hour with suitable capacity prime mover. The pump shall be of cast iron body, bronze impeller, with mechanical seals, TEFC squirrel cage IE-2 induction motor, with M.S. Fabricated base plate, mounting channel frame, accessories and fittings like pressure gauges, Air release valve, drains, coupling, coupling guard etc including PCC foundation, vibration isolation arrangement complete all as specified in the particular specification. (2 working and one stand by)
57Supply install test and commissioning of chlorine dosing pump (venturi drive pump) 0 - 6 LPH with PP/PVC dozing tank capacity 150 Ltr - 2 Nos and piping for in let & out let connection complete with control valves, NRV,metering, electric cabling & copper wiring through suitable size PVC concealed conduit from Main control panel to Chlorine dosing pump complete all as specified and as directed.
58Supply install test and commissioning of Acid/alkali Dosing pump (venturi drive pump) 0 - 6 LPH with PP/PVC dozing tank capacity 150 Ltr with high speed stirrer and piping for in let & out let connection complete with control valves,NRV,electric cabling & copper wiring through PVC conduit from Main control panel to Acid/ alkalidosing pump complete all as specified and as directed.
59Supply, installation, testing and commissioning of Pool Drain (Drain-out Sump) of size 500 mm × 500 mm, fabricated from Stainless Steel Grade SS 304, complete with all necessary accessories and fittings.Make : lon exchange / Voltas / Eureka Forbes.
60Supply install test and commissioning of Pool Skimmers of size - 600 MM x 150 MM X 40 MM fabricated from Stainless Steel Grade SS 304, complete with all necessary accessories and fittings.Make - Ion exchange / Voltas / Eureka Forbes.
61Supply install test and commissioning of Pool Hair & lint cathcher size - 600 MM x 150 MM X 40 MM with mesh and handle fabricated from Stainless Steel Grade SS 304, complete with all necessary accessories and fittings.Make - Ion exchange / Voltas / Eureka Forbes.
62Supply and install Stainless steel ladders of Swimming pool made out of model stainless steel AISI-304 of width 500 mm with handrails and shall be 40 mm dia of stainless steel with non-slip of Pool ladder 3 steps all as shown on drg and all as dircted by E-in-Charge Make - Ion exchange /Voltas /Eureka Forbes
63Supply and install Stainless steel ladders of Swimming pool made out of model stainless steel AISI-304 of width 500 mm with handrails and shall be 40 mm dia of stainless steel with non-slip of Pool ladder 4 steps all as shown on drg and all as dircted by Engr-in-Charge. Make - Ion exchange /Voltas /Eureka Forbes
64Supply and install Stainless steel ladders of Swimming pool made out of model stainless steel AISI-304 of width 500 mm with handrails and shall be 40 mm dia of stainless steel with non-slip of Pool ladder 5 steps all as shown on drg and all as dircted by Engr-in-Charge. Make - Ion exchange /Voltas /Eureka Forbes
65Supply and install Over flow grating 300 mm x 300 mm wide shall be provided as shown in drawing with slope 1:200, towards balancing tank including Gratings and support profiles made in white UV stabilized PP of size wide complete all as specified and as directed. Make - Ion exchange /Voltas /Eureka Forbes
66Supply install test and commissioning of Trolley mounted suction sweeper with self priming electric driven pump set suitable for cleaning swimming pool capacity ,complete with PVC braided vacuum hose pipe of length minimum 30 Mt, 900 mm size Aluminium / bronze vacuum head, flexible copper cable from Main, PVC floats, wire rope and all connected accessories complete all as specified and as directed.
67S&F 18 inch long Nylon brush complete all as specified and as directed. Make : Ion Exchange India Ltd/Voltas /Eureka Forbes
68S&F Telescopic pole 4.8 Mtr long with extendible up 9 Mtr made of aluminium tubing complete complete all as specified and as directed.
69S&F Test Kit for PH & Residual chlorine complete all as specified and as directed.
70S&F Leaf rack made out of aluminium frame all as per sample complete all as specified and as directed.
71S&F Leaf skimmer made out of aluminium frame all as per sample complete all as specified and as directed. Please Enable Macros to View BoQ information
72S&F Leaf skimmer made out of aluminium frame all as per sample complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56504422
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 6.06 Crore
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Provision Of Deficient Swimming Pool Within Hqtnp Complex At Chennai:
Basic Detail
Tender No 88760
Bidding Type Tender
Location
City Chennai
State Tamil Nadu
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 6.06 Crore
Tender Fee 3000
EMD 6.28 Lakhs
Exemption Available
Document List
017e0cc5-0cfd-4914-8b66-115d302fa348.html
88760.pdf
BOQ_872622.xls
Revised_Drawing.rar
Sch.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 17 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 24 days

Tender Documents

Download All (ZIP) ↓
html

017e0cc5-0cfd-4914-8b66-115d302fa348.html

pdf

88760.pdf

xls

BOQ_872622.xls

rar

Revised_Drawing.rar

pdf

Sch.pdf

pdf

Tendernotice_1.pdf

Disclaimer