Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56504377

Tender For Repair/Maintenance & Rerouting Of Lt Cables And Connected Items At arc-biannual rate contract Line, Abdul Hamid Vihar, Abdul Hamid Vihar Family Qtr, Arjan Vihar, Pratap Chowk Area, Mandir Marg, Ahpu, Tauras Enclave, Aepta, Station Road, Sh

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
46 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
15 days left
EMD
92000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair/Maintenance & Rerouting Of Lt Cables And Connected Items At arc-biannual rate contract Line, Abdul Hamid Vihar, Abdul Hamid Vihar Family Qtr, Arjan Vihar, Pratap Chowk Area, Mandir Marg, Ahpu, Tauras Enclave, Aepta, Station Road, Shopping Centre, Mynamati Lines, Balwan Lines, Assu And Adjoining Area In The Area Of Age (U) Elect Supply No. Ii, Under Ge (U) Elect Supply, Delhi Cantt-10

BOQ

Name of Work:- REPAIR/MAINTENANCE & REROUTING OF LT CABLES AND CONNECTED ITEMS AT BI LINE, ABDUL HAMID VIHAR, ABDUL HAMID VIHAR FAMILY QTR, ARJAN VIHAR, PRATAP CHOWK AREA, MANDIR MARG, AHPU, TAURAS ENCLAVE, AEPTA, STATION ROAD, SHOPPING CENTRE, MYNAMATI LINES, BALWAN LINES, ASSU AND ADJOINING AREA IN THE AREA OF AGE (U) ELECT SUPPLY NO. II, UNDER GE (U) ELECT SUPPLY, DELHI CANTT-10
Sl. No. Item Description
1Material & labour for excavation in trenches not exceeding 1.5 metre wide & not exceeding 1.5 meter in depth for foundation, laying of cable or pipe (where provided for protection of cable or fixing with poles and stays) and getting out in any type of soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and directed by the Engr-in-Charge.
2Material & labour for returning filling in, Including spreading, levelling, Watering and well ramming soil in layers not exceeding 25 cm thick complete all as specified and directed by the Engr-in-Charge.
3Material & labour for removal excavated material (i.e. soil) from site to a distance n. exc 50 mtrs away and depositing where directed at a level n. exc. 1.5 mtr above the starting point complete all as specified and directed by Engr-in-Charge.
4Material and labour for river washed and screened, dry sand for filling in trenches below and around underground cables for cushioning of cables etc,complete all as specified and directed by the Engr-in-Charge. Note : Measurement shall be taken after punning down.
5S&F sub class B bricks having minimum compressive strength 75 Kg/ Sqcm laid in trenches for cable protection etc complete all as specified and directed by the Engr-in-Charge.
6All as per srl item No 5 here-in-before but using old bricks obtained under srl item No 1 here in before. complete all as specified and directed by the Engr-in-Charge.
7Supplying, laying, jointing testing and connecting in replacement of overhead lines/underground cables, XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, IS 7098 marked, suitable for LT 1100 Volt system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed by the Engr-in-Charge of following sizes:-Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately under respective items of schedule.
816 Sqmm 4 core
925 Sqmm 3.5 core
1035 Sq mm 3.5 core.
1150 Sq mm 3.5 core.
1270 Sqmm 3.5 core
1395 Sqmm 3.5 core
14120 Sqmm 3.5 core
15185 Sqmm 3.5 core
16240 Sqmm 3.5 core
17300 Sqmm 3.5 core
18Material & labour for boring of hole under road/pavement/hard standing or any other situation by manual means and suitable for passing of GI pipe 40 to 100 mm bore and making good both ends complete all as specified and directed by the Engr-in-Charge.
19Supply & fixing in replacement GI Pipe (light grade) with necessary accessories/ fittings for cable protections/pole for crossing of culverts/nallah complete all as specified and directed by the Engr-in-Charge of following bore sizes :-
20100mm
2180 mm
2250 mm
2340 mm
24Taking out faulty underground 1100 Volt LT cable of different sizes by excavation and removing bricks of any size and relaying in the same trenches or re routing after rectification of fault or replacing faulty portion of cable with new cable and removing of surplus soil and using new bricks as required complete all as specified and directed by the Engr-in-Charge.Note: (a) 1100 Volt LT cable & joints shall be measured and paid for seperately under respective items of schedule. (b) Retrieved old serviceable bricks will be laid in trenches for cable protection. If extra bricks and sand required at site shall be measured and paid separately under respective items of BOQs.(c) Excavation and earth work will be measured and paid for seperately under respective items of schedule.
25Supply, fixing and testing straight through joint heat shrinkable type with jointing kit suitable for cable PVC/XLPE insulated armoured heavy duty aluminium conductor 1100 Volts grade complete all as specified and directed by the Engr-in-Charge. for the following sizes :-
2616-25 Sqmm x 3.5 core/ 4 core
2735-50 Sqmm x 3.5 core
2870-95 Sqmm x 3.5 core
29120-150 Sqmm x 3.5 core
30185 -240 Sqmm x 3.5 core
31Suplying and laying as replacement in sub station fixing 3.3 to 11 KV electrical insulation mat of size 5 mtr x 1 mtr x 2.5 mm thick specification as per IS 15652 2006 complete all as specified and directed by the Engr-in-Charge.
32Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swaged poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc complete all as per manufacturer's instructions and complete all as specified and directed by the Engr-in-Charge. NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
33Taking down unservicable RCC/ steel tubular poles of any type and supply & installing steel tubular swan neck poles type 410 SP-31 (9 mtr long) of approx wt.147 kg conforming to IS 2713 (Part-II), complete with cast iron/MS plate 6mm thick and of size 300x300mm, final taper, pole cap, bolts, nuts, washers & screw etc including excavation, earth work, PCC foundation,PCC coping,GI pipe for cable protection etc complete all as per manufacturer's instructions and complete all as specified and directed by the Engr-in-Charge.NOTE:- The unit rate in this item is deemed to be included the cost of exacavation and earth work in any type of soil,PCC foundation 1:4:8 type D-2 , PCC coping 1:2:4 type B-1 as in steel tubular pole The steel pole shall be painted by bituminious paint total length inside and up to planting depth outside and remaining portion of pole painted with two coat of aluminium paint over a coat of red oxide complete all as specified and directed.
34Supply & fixing in replacement of KIOSK box wheather proof including made out of one piece mounted SMC base and door pole mounted hinged door size 333x233x120mm out side and 300x200x105mm inside dimensions comprising of aluminium bus bar 4 strips for 3 phase and neutral with 6 Amps MCB SP including embossing/painting of danger notice on front face of KIOSK box body complete all as specified and directed by the Engr-in-Charge.
35Supply, installing, testing and commissioning in replacement of factory made and tested Bus bar chamber outdoor type with canopy made out of 3.15 mm CRCA MS sheet, and 40x40x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, with apron for cable entry closing locking arrangement ,of appropriate size with 4 Nos 500 Amps aluminium bus bar, RYB indication lamp and with 250 Amp MCCB, 4 pole, 36 KA, 415 Volt 50 Hz including excavation, earth work and platform for the Bus bar chamber with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for Bus bar chamber. The platform shall be such that it is of a height 45 cm above the nearest road level.complete all as specified and directed by the Engr-in-Charge.
36Supplying and installation in replacement factory made and tested (including CPRI type tested certified panel) Timer Panel board, cubical, outdoor type, platform mounted, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and minimum 32x32x5mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front opening type, closing locking arrangement including power wiring with 10 Sqmm PVC insulated solid, copper conductor FRLS cable, IS-694 marked, 1100 volts grade and internal wiring with 1.5 Sqmm copper conductor and comprising of the following :-(i) MCCB 3 pole , 32 Amps,50 Hz,415 Volts, 16 KA, with thermal magnetic release - 01 No (ii) 3 Pole power contractor, 32 A, AC, 3 Phase -01 Nos (iii) Astronomical Time switch , 240 Volt AC , 50 Hz -01 Nos(iv) Auto /manual selector switch -10 No(v) Aluminium bus bar 100 Amps, 4 strip 3 phase and neutral 415 volts, 50 Hz, duly insulated with heat shrinkable PVC sleeves- 01 SetPlatform for the timer panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level.
37Material & labour for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed by the Engr-in-Charge.
38Material and labour in replacement Retro Reflective installation sign boards of size 12 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 9.00 meter above ground level on stainless steel heavy duty pipe of size 80mm bore embaded 75 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx75cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by the Engr-in-Charge. Please Enable Macros to View BoQ information
39Material and labour in replacement Retro Reflective installation sign boards of size 12 feet x 4 feet fabricated out of 16 gauge MS sheet frame duly welded/riveted with MS square pipe of size 25mm x25mm at height 9.00 meter above ground level on stainless steel heavy duty pipe of size 80mm bore embaded 75 CM in PCC 1:2:4 type B 1 block of size 45cmx45cmx75cm including necessary excavation and earth work .The steel portion of the board shall be painted in stove enameled paint and the front & back of the frame shall be overall sheathed with blue colour base painter adhesive tape. The wiriting matter will be in English language on both sides with reflective adhesive painter tapes complete all as specified and directed by the Engr-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56504377
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 46 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair/Maintenance & Rerouting Of Lt Cables And Connected Items At arc-biannual rate contract Line, Abdul Hamid Vihar, Abdul Hamid Vihar Family Qtr, Arjan Vihar, Pratap Chowk Area, Mandir Marg, Ahpu, Tauras Enclave, Aepta, Station Road, Shopping Centre, Mynamati Lines, Balwan Lines, Assu And Adjoining Area In The Area Of Age (U) Elect Supply No. Ii, Under Ge (U) Elect Supply, Delhi Cantt-10
Basic Detail
Tender No GE ELECT/TOKEN-21/2026-2027
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 46 Lakhs
Tender Fee 500
EMD 92000
Exemption Not Available
Document List
a2789aa1-ad2b-4d7d-81cf-0b1c9afbd0a8.html
BOQ_872526.xls
TD21.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 17 days

Tender Documents

Download All (ZIP) ↓
html

a2789aa1-ad2b-4d7d-81cf-0b1c9afbd0a8.html

xls

BOQ_872526.xls

pdf

TD21.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders