Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56504355

Tender For Internal Periodical & Repair / Replacement Of Doors, Cabinets With Wpc Shutter, Fittings And Misc B/R Work At Rrrc Including Repair / Replacement Of Unsv Electrical Fitting & Fixtures And Maiint Of Distribution Boards With Mcb, Mccb, Sub M

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
50 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
16 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Internal Periodical & Repair / Replacement Of Doors, Cabinets With Wpc Shutter, Fittings And Misc B/R Work At Rrrc Including Repair / Replacement Of Unsv Electrical Fitting & Fixtures And Maiint Of Distribution Boards With Mcb, Mccb, Sub Main Wirings Etc At Jcos/Or Md Accn Of Ichhamati Line At Rrrc Under Ge (Central) Delhi Cantt-10

BOQ

Name of Work:- INTERNAL PERIODICAL & REPAIR / REPLACEMENT OF DOORS, CABINETS WITH WPC SHUTTER, FITTINGS AND MISC B/R WORK AT RRRC INCLUDING REPAIR / REPLACEMENT OF UNSV ELECTRICAL FITTING & FIXTURES AND MAIINT OF DISTRIBUTION BOARDS WITH MCB, MCCB, SUB MAIN WIRINGS ETC AT JCOs/OR MD ACCN OF ICHHAMATI LINE AT RRRC UNDER GE (CENTRAL) DELHI CANTT-10
Sl. No. Item Description
1Taking down cement plaster of any description on brick stone or concrete walls surfaces including raking out joints hacking for keys scrubing down with water etc up to 10m height complete all as specified and directed.
2M&L for rendering 10mm thick in CM 1:6 other than fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete.
3M&L for rendering 5 mm thick in CM 1:4 on ceiling other than fair faces of brick work or concrete surfaces finished without using extra cement complete.
4M&L for Preparation of new surfaces (Plastered or un-plastered) of walls and applying two coats of oil bound distemper over one coat of wall care putty complete all as specified.
5M&L preparing newly plastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
6Taking down chowkhat or frame not exceeding 1.5 sqm each with shutter (without taking off shutter from the frame)
7Taking down chowkhat or frame exceeding 1.5 Sqm each and not exceeding 4 Sqm each sqm each with shutter (without taking off shutter from the frame)
8Taking down shutters of any description not exc 2 Sqm each.
9M&L Mild steel frame work as in door chowkhats with angle iron welded together ends of angle shouldered and fixed to opening and welding 3 Nos mild steel butt hinges 100 mm size, and 6 nos hold fasts made out of FI 25x3 mm 30 cm long for fixing of chowkhats( Butt hinges paid sep) all as spd.
10S&F 35 mm thick 2nd class hard wood glazed and skelton shutter devided into square with plain, chamferred or rounded sash bar and fitted with cut and mitred beads for securing glass, size of members as per SSS Part - I section 8 clause 8.24 (b).
11S&F Factory Made single extruded WPC (Wood Polymer Composite) Solid door/window/Ceosetory windows & other frames/ chowkat of size 65x 125 mm comprising of virgin PVC polymer of K value 50-60 (Suspension Grade), calcium carbonate and natural fibers( wood powder/ rice husk/ wheat husk) and non toxic additives ( max toxicityindex of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face & 1100 N Edge), min compressive strength of 58N/sqmm and resistance to flame of class A category with property of being termite/ borer proof, water/ moisture proof and fire retardant and fixed with MS Holdfast/ lugs/SS dash fasteners of required dia and length complete as per direction of Engr in charge.Note: For WPC solid door/windows frames,minus 5mm tolerance in dimension i.e depth and width of profile dimension on plus side shall be acceptable but no extra payment on this account shall be made.
12S&F Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of EngineerIn- Charge. (Note: stainless steel butt hinges and necessary S.S screws shall be paid separately)complete all as specified and directed.
13S&F Floor door stopper of aluminium alloy body and tongue, overall length of cover plate 150 mm , anodized, with hard drawn steel spring, fixed to shutters, complete all as specified and as directed.
14M&L aluminium alloy powder coated door including frame and channel of section (Door frame single grove 101.6mm x44.45 mm x2.1,shutter top section 47.62mm x44.45x1.95mm thick shutter bottem vertical section 85 mm x44.45 mm x1.80mm yhick ,shutter middle section 83.50mm x 44.45 mm x1.80mm thick shutter glazing clips weighing not less than 0.097 kg/Rm as directed and approved by GE and as per IS specification including provn of 5.5mm thick tinted glass/12mm thick thick prelaminated particle board as required including alu handle 150 mm ,tower bolt 150 mm ,floor spring heavy duty \\"SAMRAT\\" ,looking arrangement \\"GODREJ\\" rubber gasket and door stopper complete all as specified and directed.
15M&L aluminium alloy powder coated windows including aluminium coated frames, silding track frame and bottom weighing not less than 1.015 kg/Rm ,sides and top not less than 0.826 kg/Rm double revated and 0.55 kg/Rm for window shutter with one fixed glazed shutter and two nos glazed/gauged shutter silding type with aluminium sectins as per series-A (15mm) 3 track of jindal section number for silding windows with framed shutter including aluminium allow powder coated snap type beads handles with locking arrngement spring action and glazing clips joint cleats rubber gaskets etc inclding provision of 5.5 mm thick tinted frosted glass of superior quality and stainless steel jail including all standard fittings complete all as specified and directed
16S&F aluminium ventilator partly glazed/ gauzed including including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. provision for fixing the exhaust fancomplete all as specified and as directed
17Servicing and greasing of aluminium door including replacement nut , screws rubber gaskets, pivot, taper clip etc including taking down carefully of door shutter for replacing unserviceable parts/components by new parts /components for smooth functioning of door and refixing the same in existing opening/position, complete, all as specified and directed.
18S & F in repair Steel window (Factory made) double rebate, with side hung, shutter incl hinges, tower bolt, steel handle and peg stay complete with glaze and gauge shutters (both are complete) devotailed or welded including making good to cutting holes with PCC 1:2:4 and complete finishing to cill and jamb corners with plaster and match all as specified
19S & F in repair mild steel framed work such as grillsn gratings, etc, with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders freamed balusters, walk ways, railings, framework of watertanks and similar work including aldrop and hinges holdfast etc conforming to Fe 290. Gde-E-165.
20Cutting holes in Cutting holes in brick walls in mud mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 complete, all as specified and directed.
21S&F aluminium body hydraulically Door closer regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed as in repairs complete, all as specified and directed.
22S&F MS butt hinges medium weight 100 mm size fixed with MS screws.
23S&F aluminium anodised barrel tower bolt extruded section 150 mm long and fixed with MS screws.
24S&F 150 mm extruded aluminium alloy handle anodised fabricated type and fixed with mS screws.
25S&F 300 mm extruded section aluminium alloy anodised, sliding door bolt with hasp and staple and fixing clip of sheet and fixing bolt and nut.
26M & L for preparation of new or previously untreated wooden surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer
27S & F in repair stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm complete all as specified and directed.
28Taking up or down Galvanised steel tubing and connections, including cleaning for re-fixing, bore of tubing 15mm
29Taking up or down Galvanised steel tubing and connections, including cleaning for re-fixing, bore of tubing 20mm
30Supply and fix galvanized steel tubing, 15 mm bore medium grade all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors compsite fitting such as (Nipple, Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc complete all as directed.
31Supply and fix galvanized steel tubing,20 mm bore medium grade all fittings and short tube pieces, fixed complete to walls and ceilings or laid in floors compsite fitting such as (Nipple, Elbow, Tee, Socket, Reducer, Bushing, Step over bends, End cap, End Plugs etc complete all as directed.
32Supply and fix in repair figured glass pin head type 4mm thick ordinary quality and glazing with oil putty in squares not exc 0.5 sqm in each pane fixed with oil putty or wooden beads including provision of glazing pins/ spring clips wherever necessary, complete all as specified
33M&L providing and applying the plaster with single component ready to use repair mortar (SMART CARE REPAIR MORTAR or equivalent) capable of applying 15mm average thickness in single layer and finishing with trowel with a bond coat: SBR polymer (@ 10% of cement weight) modified cementious bond coat @ 2.2 kg cement/Sqm of surface area mixed with specified portion of AP SMARTCARE or equivalent Repair Polymer including taking down existing roof treatment of any type and also taking down cement plaster on brick/concrete surfaces, including raking out joints, hacking for key, scrubbing down with water etc., to receive further treatment, complete all as specified land as directed. Make: Asian Paints or equivalent in Sikka, Fosroc and STP Ltd.Note: The application shall be executed on any type of surface and on horizontal/Vertical areas.
34M&L providing and applying Smartcare Dampproof, a fibre reinforced elastomeric liquid water proofing membrane formulated with reinforcing acrylic fibers having Sun Reflectivity Index (SRI) of 105 on horizontal/vertical surfaces of roof/wall/chajas in multiple coats @2.0 litre/sqm. Primary [coat is self-priming coat of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1, damp proof : water) and other coats to be applied undiluted. The coating needs to be reinforced with 40 GSM geotextile/fibre, to sandwiched between 2nd & 3rd coat of coating. The application shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes complete in all respect as per the direction of Engineer-in-Charge.Make: SmartCare Damp Proof of Asian Paints or equivalent in Berger/ Nerolac/STP Ltd.Notes: (1) The work shall be executed through authorised applicator of manufacturer only.(2) Authrised Applicator shall be approved by GE before starting of work.(3) All materials shall be procured directly form manufacturer. The purchase voucher shall be produced to the Engineer-in-Charge for his verification of material.Engineer-in-Charge shall deface the original purchase vouchers.(4) Guarantee: The contractor shall furnish a written guarantee for the effectiveness of the water proofing treatment for a period of Eight years in favour of the GE. A sum equivalent to 2.5% (Two point Five Percent) of the cost of water proofing treatment shall be retained by the Govt from the contractor's dues as security deposit. The contractor may, however, furnish a fixed deposit receipt in lieu from a Schedule bank pledged in favour of Garrison Engineer.
35M & L for PCC 40 mm thick (Avg thickness) type B-0, 1:2:4 (using 12.5mm graded stone aggregate) as in roof complete all as specified and directed.
36Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete incl fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
37M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through existing PVC conduit with conduit accessories including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuity and fabricated branded modular metal flush box/M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate/3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc, all as specified and as directed for the followings:-
38One light/fan point controlled by one way switch
39One bell/buzzer point controlled by one bell push
40One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
41One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
42All as per item No 37 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
43M&L point wiring with PVC insulated FRLS 1100 Volts unsheathed cable 1.5 Sqmm multistranded copper conductor and drawing concealed in wall & including rigid PVC conduit FRLS, medium grade ,ISI marked ,terminal box of 1.6 mm thick and 3 mm thick hylam sheet cover/Modular cover for terminal boxes also including porvision of earth wire PVC insulated FRLS 1100 Volts unsheathed 1.5 sqmm stranded copper conductor single core cable connected to common earth dolly the following :
44One light/fan point controlled by one way switch
45One bell/buzzer point controlled by one bell push
46One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
47One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
48All as per item No 39 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
49M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
50M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
51M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
52M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
53M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
54M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
55M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
56M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
57M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
58M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge.
59M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge.
60M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
61M&L in replacement socket outlet 5 pin 6 Amp flush button type complete all as specified and directed by Engineer in charge.
62M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
63M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
64M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
65S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
66M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'B' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
67Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 20 Watts, lifetime of 25000 burning hours with 70% of its initial lumen maintained, Power Factor not less than 0.90, colour temperature-6500K, IP-20 protected, voltage range-180 to 240 Volts AC, temperature range 0 to 50 Degree C and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and directed.
68Supply and fix LED batten luminaire surface mounted, 2 feet system wattage of 10 Watts, lifetime of 25000 burning hours with 70% of its initial lumen maintained, Power Factor not less than 0.90, colour temperature-6500K, IP-20 protected, voltage range-180 to 240 Volts AC, temperature range 0 to 50 Degree C and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting complete all as specified and directed.
69Supply and fix LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, with a life class of 25,000 burning hours, Power Factor not less than 0.90, driver with voltage range 180-270V, Temperature range 0 to 50 Deg, colour Temperature-6000K, including connecting up with necessary PVC sheathed 3 core 1.5 sqmm copper conductor flexible wire fixed complete all as specified and directed.
70S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge.
71Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, life time of 25000 burning hours, 6500K colour temperature,Power Factor not less than 0.90, Driver with voltage variation range-180 to 240 Volts AC, including connecting up with PVC sheathed 3 core 1.5 Sqmm copper conductor flexible wire fixed complete all as specified and directed.
72Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge.
73Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
74Supply and fix MCB DB SPN 12 way Horizontal, IP-43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete all as directed by Engineer -in- Charge.
75Supply and fix MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar, neutral link earth link complete all as directed by Engineer -in- Charge.
76Supply and fix in repair MCB SPN 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
77Supply and fix in repair MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
78Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge.
79Supply and fixing Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
80Supply and fixing Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
81Supply and fix wall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
82S & F water heater storage type (Geyser) vertical type with suitable size of fastner and incl provision and connecting up of SS braided pipe with adopter for inlet and outlet water connection, having adjustable knob for temperature control and inner tank material of superior glass lined tank and outer body material ABS with high pressure with standing capacity upto 8 bar pressure complete all as specified of capacity 25 ltr having heating element 2 KW and not less than 5 star rating with minimum two year warrant on product. Note : old unservicable geyser will be deposoted in MES yard. conversion against low rating to 5 star rating.
83Supply and fixing ceiling fans complete with blade, down rods, with remote and accessories rated speed not less than 330 RPM, 230 V, 1200 mm sweep, air delivery not less than 220 CMM, BEE five star rated voltage range 140 - 280 volts with brushess direct current motor (BLDC) all as specified and directed by Engr in Charge. (Against BLDC converson). Old fan deposited to MES yard.
84Supply and fix in repair MCCB 125 Amps, FP 415 volts 16KA , 4 Pole, 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
85Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with double door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
86S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed.
87Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit or casing capping of suitable size on walls all as specified and as directed.
88Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through drawn through and including 25 mm dia non metallic rigid PVC conduit in walls all as specified and as directed.
89Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 10 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit in walls all as specified and as directed.
90S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
91S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
92S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
93S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
94S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
95M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
96M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
97M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
98M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge. Length of wire of each roll is not less than 90 mtr.
99Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
100Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 150 cm long with brass nuts and rubber washers complete all as specified and directed.
101Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
102Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
103M & L for opening up the winding of ceiling fan 1200/1400 mm sweep any make any type and rewinding with super enamelled copper winding wire after inserting super enamelled insulating material binding it with insulating tape etc completely and varnishing well including drying completely. Replacement of worn out / unserviceable capacitor bearing , bush , safety pins, nuts, bolts, washers , rubber bush with ceiling fan clamp, cable PVC flexible 23/0076 and testing the ceiling fan after re-fixing of the blades to the entire satisfaction of Engineer-in-Charge.
104Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
105S&F LED 2 X 2 ft backlite surface mounted fitting 36 Watts not less than 3200lm with Metallic CRCA powder coated body with high efficiency opal/PMMA diffuser with system efficacy > 80 lm/W, CRI>70, color temperature >5700k, IP 20, Power factor<0.90, life time of 25000 burning hours , Ambient temperature 0 to 50 DegC, Voltage variation range of 180-270 V and surge protection of 2.5 KV including necessary fixing arrangementsfixed complete all as specified and directed.
106S&F not less than 35 Watt High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP-66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall complete as specified and directed.
107Schedule of Credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56504355
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Internal Periodical & Repair / Replacement Of Doors, Cabinets With Wpc Shutter, Fittings And Misc B/R Work At Rrrc Including Repair / Replacement Of Unsv Electrical Fitting & Fixtures And Maiint Of Distribution Boards With Mcb, Mccb, Sub Main Wirings Etc At Jcos/Or Md Accn Of Ichhamati Line At Rrrc Under Ge (Central) Delhi Cantt-10
Basic Detail
Tender No GE/TOKEN-43/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Available
Document List
BOQ_872601.xls
Tendernotice_1.pdf
tenderpage.pdf
83308ed2-bbca-4f18-85b0-397e8e0af7c9.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days