Housing Urban and Rular Development Government Departments Closing in 7 days TDR #56503392

Tender For Construction Of Residential Building And Re-Fencing Of Fodder Development Farm Lam (Block, A,B,C &D) Nowshera.

Issued by Government Departments · Rajouri, Jammu and Kashmir
Tender Value
4.69 Crore
Estimated cost
Bid Submission
01 Aug 2026
7 days left
EMD
9.38 Lakhs
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Rajouri → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Residential Building And Re-Fencing Of Fodder Development Farm Lam (Block, A,B,C &D) Nowshera.

BOQ

Name of Work:- Construction of Residential Building and Re-fencing of Fodder Development Farm Lam (Block, A,B,C &D) Nowshera.
Sl. No. Item Description
1Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: All kinds of soil.
2Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size)
3Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all work up to plinth level in 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate) 40mm nominal size crushed.
4Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
6Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
7Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
8Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°,landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse 1:1½:3(1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size).
9Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete
10Centering and shuttering including strutting, propping etc. and removal of form work for:
11Foundations, footings, bases for columns for mass concrete.
12Columns, pillars, piers, abutments, posts and struts
13Lintel, beams, plinth beams, girders, bressumers and cantilevers.
14Suspended floors, roofs, landings, balconies and access platforms
15Edges of slabs and breaks in floors and walls,Under 20 cm wide.
16Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand).
17Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five leveL.
18Providing and fixing M.S. grills of required pattern in frames of windows etc.with M.S. flats, square or round bars etc including priming coat with approvedsteel primer all complete.Fixed to openings / wooden frames with rawl plugs screws etc.
19Structural steel work in built up sections, trusses and framed work,including cutting, hoisting, fixing in position and applying a priming coat ofapproved steel primer all complete. Welded
20Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angles 40x40x6mm for diagonal braces
21Add for plaster drip course/grooves in plastered surface or moulding to R.C.C. projections
226 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand)
2312mm Cement plaster finished with a floating coat of neat cement of mix: 1 : 4 ( 1 cement : 4 fine sand)
2412 mm cement plaster of mix 1:6 ( 1 cement : 6 coarse sand)
2515mm Cement plaster on the rough side of single or half brick wall of mix 1 : 6 ( 1 cement : 6 fine sand)
26Providing and laying drain flooring / coping 50 mm thick with cement concrete 1:2:4 (1 cement:2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and curing complete
27Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For fixed portion Powder coated aluminum (minimum thickness of powder coated 50 microns)
28Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size includingnecessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Powder coated aluminum (minimum thickness of powder coated 50 microns)
29Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineerin- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm)
30Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc.complete as per architectural drawings and directions of engineer-incharge. Pre-laminated particle board with decorative lamination on both sides.
31Providing and fixing fly proof wire gauze to windows, clerestory windows and doors with M.S Flat 15x3 mm and nuts and bolts complete. Stainless steel (grade 304) wire gauze of 0.5mm dia wire and 1.4 mm aperture on both sides.
32Filling the gap in between aluminum frame and adjacent RCC/Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5mm width
33Providing and fixing Anodized aluminum grill (Anodized transparent or dyed to required shade according to IS: 1868 minimum anodic coating of Grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing windows frame with C.P. brass/stainlesssteel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved Anodized aluminum standard section around the opening, all complete as epr requirement and direction of Engineer-in-charge. (only weight of grill to be measured for payment)
34Providing and fixing aluminum extruded section body tubular type universalhydraulic door closer,(having brand logo with IS: 3564, embossed on the body,door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm),with double speed adjustment with necessary accessories and screws etc.complete :
35Providing and fixing aluminum sliding door bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with nuts and screws etc. complete 250x16 mm
36Providing and fixing aluminum tower bolts ISI marked anodized (anodiccoating not less than grade AC 10 as per IS : 1868) transparent or dyed torequired colour or shade with necessary screws etc. complete :
37200x10 mm
38150x10 mm
39100x10 mm
40Providing and fixing aluminium tower bolts lSI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete 125MM
41Providing and fixing aluminum casement stays, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
42Providing and fixing bright finished brass 100 mm mortice latch and lock with 6levers and a pair of lever handles of approved quality with necessary screws etc.complete.
43Providing and fixing aluminum hanging floor door stopper, ISI marked, anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete.Twin rubber stopper.
44Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm
45Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
46Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS : 15622(thickness to be specified by the manufacturer), of approved make, in all colours, shadesexcept burgundy, bottle green, black of any size as approved by Engineer- in-Charge, inskirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement :3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointingin white cement mixed with pigment of matching shade complete.
47Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) : Granite of any colour or shade (Area of slab upto 0.5 sqm) (16 mm thick)
48Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes channels, plates etc. including welding ,grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete ,including fixing the railingwith necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.).
49Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc.including machine polishing to edge to give high gloss finish etc. complete as per designapproved by Engineer-in-Charge. Marble Work
50Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 2 mm thick
51Wall Painting with acrylic emulsion paint of approved brand andmanufacture to give an even shade. Two or more coats on new work
52Finishing walls with textured exterior paint of required shade on New work (two or more coats applied @ 3.28 liter/10sqm) over and including base coat of exterior primer applied @ 2.20kg/10sqm
53Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mmnominal size well rammed and consolidated and grouted with fine sand including finishingthe top smooth and curing complete
54Providing and fixing PVC rain water pipes conforming to IS: 13592 Type A including jointing for Weep holes:
5575 mm diametre
56110 mm diametre
57Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Coupler
5875 mm diametre
59110 mm diametre
60Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Single tee with door
6175x75x75 mm
62110x110x110 mm
63Providing and fixing on wall face un-plasticized - PVC moulded fittings/accessories for un plasticized Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS : 5382 leaving 10 mm gap for thermal expansion Bend 87.5°
6475 mm bend
65110 mm bend
66Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectorsetc.This includes testing of joints complete as per direction of the Engineer-in-charge: Internal work concealed with clamps at 1.00 meter spacingincluding cutting the chases and making good the wall etc.
671216 (16mm OD) pipe
681620 (20mm OD) pipe
69Providing and fixing Polyethylene- Aluminum- Polyethylene (PE-ALPE) Composite Pressure Pipes conforming to IS: 15450, U.V. stabilized with carbon black having thermal stability for hot and cold water supply, capable to withstand temperature upto 80ºC, including all special fittings of composite material (engineering plastic blend and brass inserts wherever required) e.g. Elbows, tees, reducers, couplers and connectors etc.This includes testing of joints complete as per direction of the Engineer-in-charge: IExternal work including trenching and refilling etc.complete
7011216 (16mm OD) pipe
711620 (20mm OD) pipe
722025 (25mm OD) pipe
73Providing and fixing ball valve (brass) of approved quality, High or lowpressure, with plastic floats complete 25 mm nominal bore
74Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever), conforming to IS:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with ISI marked white solid plastic seat and lid.
75Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040mm bowl depth 250mm
76Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge.
77Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
78Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
79Providing and laying in position flow trap including all fittings, complete job
80Providing and laying in position P-trap including all fittings, complete job
81Providing and fixing uplasticized PVC connection pipe with brass unions 30 cm length 15 mm nominal bore
82Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete: Flexible pipe 32 mm dia
83Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet 150 mm diameter
84Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931
85Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms
86Providing and fixing 15 mm nominal bore C.P. brass angle valve forbasin mixer and geyser points of approved make conforming to IS : 8931
87Providing and fixing C.P. Brass extension nipple (size 15mmx50mm)of approved make and quality as per direction of Engineer-incharge.
88Providing and fixing PTMT soap dish holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106gms.
89Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200 mm wide with a minimum distance of 37 mm from wall face with concealed fittings arrangements of approved quality and colour, weighing not less than 88 gms.
90Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 453x357 mm
91Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fitting arrangement of approved quality and colour: 600 mm long towel rail with total length of 645 mm, 78 mm wide and effective height of 88 mm, weighing not less than 190 gms.
92Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing Tee, including cutting and threading the pipe etc. complete 25 to 40 mm nominal bore
93Providing and fixing PTMT extension nipple for water tank pipe, fittings of approved quality and colour 25 mm nominal bore, weighing not less than 62gms
94Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
95Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarsesand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floatingcoat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
96Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry brickhoney comb shaft with common burnt clay (non modular) bricks of classdesignation 7.5 bricks and S.W. drain pipe 100 mm diameter, 1.8 m longcomplete as per standard design.
97Pump capacity 180 LMP, at 30 M head (1 working + 1 standby) (Domestic water relift pump)
98Providing of structural design including soil investing test from approved consultancy and also to be vetted by the GCET/DIQC/IIT/NIT one job.
99Supplying at site Angle iron post & strut of required size including bottomto be split and bent at right angle in opposite direction for 10 cm lengthand drilling holes upto 10 mm dia. etc. complete.
100Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-incharge Made of G.I. wire of dia 4 mm
101Applying priming coat: With ready mixed red oxide Zinc Chromate primer of approved brand and manufacture on steel galvanized iron/steel works
102Painting with synthetic enamel paint of approved brand and manufacture to give an even shade. Two or more coats on new work
103Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
104Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group-A)
105Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
106Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1072 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1082 x 10 sq. mm + 1 x 6 sq. mm earth wire
1094 x 10 sq. mm + 2 x 6 sq. mm earth wire
110Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.
1113 x 1.5 sq. mm
1121 x 1.5 sq. mm
1133 x 2.5 sq. mm
1143 x 4 sq. mm
115Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
116Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1175/6 A switch
1183 pin 5/6 A socket outlet
11915/16 A switch
1206 pin 15/16 A socket outlet
121TV antenna Socket outlet
122Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
123Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required
124Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings).
125Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\"curve including connections, painting etc. as required.
126Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
1271 or 2 Module (75mm X 75mm)
1283 Module (100mm X 75mm)
1294 Module (125mm X 75mm)
1306 Module (200mm X 75mm)
1318 Module (125mm X 125mm)
13212 Module (200mm X 150mm)
133Supplying and fixing following size/ modules, PVC box in recess etc as required.
1341 or 2 Module (75mm X 75mm)
1353 Module (100mm X 75mm)
1364 Module (125mm X 75mm)
1376 Module (200mm X 75mm)
1388 Module (125mm X 125mm)
13912 Module (200mm X 150mm)
140Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten).
141Casing Caping 1\\"
142Casing Caping 3/4\\"
143Supply and erection of sheet metal Double Door Distribution Boards IP 43-IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, color-coded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO's/ RCCB's in the distribution board (For SP&N distribution board with provision DP MCB's/ RCCB's/ RCBO's as incomer and SP MCB's as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB's/ RCCB's/RCBO's as incomer and SP MCB's as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc.
1446 way ( 4+18), (Double door) (TPN type)
1458 way (4 + 24), Double door (TPN Type
146Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load and site requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted in existing distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above rating including making connections, testing etc. as required. OEM shall have submit NABL / CPRI / ERDA accrediated lab type test reports & All as per pre approved by Engineer in charge.
147Single pole 6/10/16/32 Amp
148Single pole and neutral 40 Amp
149Single pole and neutral 63 Amp
150Triple pole and neutral 40 Amp
151Triple pole and neutral 63 Amp
152S&F of Mirror light LED fitting with 9/11W LED lamp
153Supplying, installation, Testing & Commissioning of 18 watt LED Recessed/ surface Down lighter (Round/ square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80 , UGR (Unified Glare Rating) < 19, Flicker free (flicker should be below 5%), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends , CCT 3000°K / 4000°K / 5700°K / 6000°K / 6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be confirming to relevant BIS standards and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing Complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 and <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C)
154Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm)
155Supplying, installation, Testing & Commissioning of 18- 22 watt LED surface mounted Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
156Supplying and fixing of following electrical items suitable for operating on 240/230Volts AC, 50 Hz supply. including connections etc. as required.
157Ceiling fan 1200 mm sweep alongwith rod upto 1'-6\\" long (3 Star)
158Exhaust fan 300 mm size (Metalic)
159Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge. LED Street Light fixture with Minimum lumen output 8700 lm
160Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall be prefilled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded with BEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendly GI Electrode Earthing should be maintinance free and does not require regular manual addition of water . The earthing pit should be covered with PVC cover.
161Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
162Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
163Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover.
164Providing and fixing of 25 mm x 5 mm copper strip on surface or in recess for connections etc. as required.
165Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
166Supplying, Installation, Testing & Commissioning of inverter 2000 VA along-with 2 Nos. long tubular batteries 150 AH and trolly of suitable size.
167SITC of wall/free standing floor mounted dust and vermin proof compartmentalized cubical panel for electrical Works, made out of CRCA sheet. Other parameters required as per point(a) Thickness of sheet shall not be less than 1.6 mm up to 600 mm length/width of anycompartment and be of 2.0 mm above 600 mm. Load bearing structure shall be of 2.0 mm thick sheet supported by base M.S. channel if required. Side walls and cable alley compartment shaving bolted type doors with/without detachable extension type structure(b) Panel shall be duly treated for derusting in 7 tank process with de phosphating and withpowder coating of minimum 70 microns on both side of panel in desired shade The panel having PU/Neoprene rubber gasket of not less than 3mm thickness, required hardware, separate detachable gland plate M.S. base channel (min 75mm), hinged door with locking arrangement for equipment/switchgear c) Interconnection between bus bar and switch gears/cable shall be rigidly supported and made out by flexible copper wires (upto 125 amp) and by solid bus bar (> 125).(d) Only outer area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator CPRI Test certificates to be submitted) All as per pre approved by Engineer in charge.
168Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type, Adjustable type)
16963 Amp, 25 KA, FP MCCB ICU = 100% ICS
170ON Load Change Over Switch FP 100 amp. (Front operated)
171Aluminium Bus Bar 100 Amp set of 4 strips 18\\"
172Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc.
173Supplying & laying of PVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable)35 sq. mm 3.5 core
174Supplying, fixing & commissioning of vertical Storage Water Heater (Geyser) of followingcapacity along with PVC Pipes etc as required. (5 Star with 8 Bar Pressure)
17515 Ltr
17635 Lt
177Supplying & fixing of (RO + UV + UF mineral control with TDS control )
178Supplying and fixing of Phenolic Laminated Sheet 9\\" x 11\\" including cutting the space forswitches/socket etc.
179Supplying and fixing of Phenolic Laminated Sheet 9\\" x 6\\" including cutting the space forswitches/socket etc.
180Supplying and fixing of Phenolic Laminated Sheet 4\\" x 4\\" including cutting the space forswitches/socket etc.
181Supplying and fixing of Phenolic Laminated Sheet 11\\" x 13\\" including cutting the space forswitches/socket etc.
182Supplying and fixing of Phenolic Laminated Sheet 6\\" x 3\\" including cutting the space forswitches/socket etc.
183Carriage of material by Mechanical Transport including loading / unloading and stacking at site complete.
184Sand for an av. 108 Kms distance.
185Bajree/Stone aggregates below 40mm nominal size for an av.distance 48 Kms
186Bricks for an avg. lead of 124 kms distance Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56503392
AUTHORITY Government Departments
TENDER VALUE 4.69 Crore
LAST DATE 01-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Construction Of Residential Building And Re-Fencing Of Fodder Development Farm Lam (Block, A,B,C &D) Nowshera.
Basic Detail
Tender No e-NIT No. 11 of 2026-27 Dated 16.07.2026
Bidding Type Tender
Location
City Rajouri
State Jammu and Kashmir
Key Dates
Publish Date 17 Jul 2026
Submission Date 01 Aug 2026
Open Date 03 Aug 2026
Finance
Tender Value 4.69 Crore
Tender Fee 6000
EMD 9.38 Lakhs
Exemption Not Available
Document List
5e0cd9fb-66f4-45fb-b28b-ef44fed3dfea.html
BOQ_1031524.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 17, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 01, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Aug 03, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 9 days

Tender Documents

Download All (ZIP) ↓
html

5e0cd9fb-66f4-45fb-b28b-ef44fed3dfea.html

xls

BOQ_1031524.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders