Tender For Repair/ Maintenance Of To Perimeter Security Lights And Allied Services At Khundru, Khanabal, Khunmoh And Khreuh & Sher-E-Shali Grn Under Ge 861 Ews.
Tender Value
47 Lakhs
Estimated cost
Bid Submission
08 Aug 2026
16 days left
EMD
94000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Anantnag → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/ Maintenance Of To Perimeter Security Lights And Allied Services At Khundru, Khanabal, Khunmoh And Khreuh & Sher-E-Shali Grn Under Ge 861 Ews.
BOQ
| Sl. No. | Item Description |
| 1 | Supply & Fixing in replacement LED Flood light fitting 30 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires with IP66 protection complete as per manufacturer's instructionsand complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Flood Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED Flood light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light Flood fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. |
| 2 | All as per serial item Ser No 1.00 here -in- before but Flood light fitting 50 Watt. |
| 3 | All as per serial item Ser No 1.00 here -in- before but Flood light fitting 70 Watt. |
| 4 | All as per serial item Ser No 1.00 here -in- before but Flood light fitting 200 Watt. |
| 5 | Supply & Fixing in replacement LED Security street light fitting 35 Watt 230 V AC outdoor type, energy saving and environment friendly light fitting with electronic gear housed with high pressure die cast aluminum housing LED street light luminaires complete with IP66 protection including all accessories complete all as specified and directed by Engineer-in-Charge. Notes:-(a) Contractor has to furnish a replacement warranty of 02 years for LED Light fittings complete including from the certifiy date of completion of CA. The product will be replaced free of cost in the following case :-(i) Manufacturing defects.(ii) Failure due to mechanical and electrical impact. (iii) Drop in lumen (or lux at 1 m) below 90% of clamied values of lumen(or lux at 1 m) of the LED /Luminaries. (b) All LED light must meet the provision laid down in IS - 16101, 16102 Part -I/II,16103 Part -I, 16104,16105,16106, 16108/2012 and 15885 Part -II / Section 13. (c) Scope of work shall include LED Light fittings walls/ceiling which includes needful T & P and required accessories etc if any, complete including making connection, testing etc complete. No extra payment is admissible on these account. (d) Cable for connection from pole to street light shall be measured and paid seperately under appropriate item of Schedule 'A' BoQ. |
| 6 | All as per item Serial no 5.00 here -in- before but LED street light fitting 60 Watt. |
| 7 | Supply and fixing in replacement of Security light bracket, 1.50 metres long, fabricated from 40 mm dia light-grade galvanised iron pipe, formed with a 30° bend, with and including flat iron clamps of size 40 mm × 6 mm, complete with suitable nuts, bolts and washers for securely fixing and bracing the bracket in position; the complete bracket and clamps duly painted with two coats of silver-coloured synthetic enamel paint over one coat of red oxide primer, including all necessary cutting, bending, drilling, fabrication, fixing and making good, complete all as specified and directed by the Engineer-in-Charge. |
| 8 | Supply & fix in replacement junction box of size 300mm x 300mm x 250 mm made with MS Sheet 1.6mm thick, front door openable with fixing screw , painting with two coats of synthetic enamel power coated paint over with and including one coat or red oxide zinc chrome primer , with and including 04 Nos. aluminium bus bars of size 25mm x 3mm mounted on epoxy based post insulators and drilled holes for connection , wih and including 01 No. MCB SP 06 amps 10 KA , 'C' curve , with and including magnetic lock system all as required and fixed to poles with and including using MS strip of size 32mm x 6mm and nuts & bolts of required size all as required at site complete all as specified and as directed by Engineer-in-charge. |
| 9 | Supply and Fixing in replacement outdoor-type SMC junction box of size 170 mm × 170 mm × 105 mm, made of one-piece moulded SMC, complete with hinged door (right- or left-hand opening) and fixed base, securely mounted on the pole with suitable fixing arrangement; provided with single electrolytic aluminium bus bars for phase and neutral, duly supported on FRP insulators, cut-outs, suitable cable inlet and outlet arrangements and provisions for cable connections, with and including one No. SP MCB, 6 Amp, ‘C’ curve 10 KA, for control of pole light, together with all necessary internal wiring, connections and accessories, complete all as specified and directed by the Engineer-in-Charge. |
| 10 | Taking out old unservicable Steel tubular pole with and including embeded portion of PCC foundation with and including Material and Labour Steel tubular poles type 410 SP-31 (9.00mtr long) complete with cast iron base plate, finial, taper plug, bolts nuts & screws complete all as specified including internal surface of steel tubular pole through out and external surface up to planting depth shall be painted with bituminous paint and remaining external surface shall be treated with two coats of aluminium paint over a coat of red oxide zinc chromate primer complete and painting upto 1.5 mtr with alternate layer of yellow & black including marking Sr No of the poles , with and including excavation and earth work such as excavtion, returing filling ,removal and form work compete all as specified and as directed by Engineer-in-charge. Notes:- 1. The rate of Necessary earthwork , such as excavtion, returing filling ,removal and form work is included in this item . Nothing shall be paid extra on this account.2. Cement concrete work shall be measured and paid seperately in respective items of Schedule 'A' BoQ. |
| 11 | Supply & fix in replacement Rigid non-metallic grade PVC conduit of size 20 mm dia, exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc, complete all as specified and directed by Engineer-in-Charge. |
| 12 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and as directed by Engineer-in- charge. |
| 13 | Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and not exceeding 1.5 m in depth and getting out in any type of soil ( Except soft/loose soil ) complete all as specified and as directed by Engineer-in- charge. |
| 14 | Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 m tr and not exceeding 3.00mtr depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, cable, pipes etc. not exceeding 10 sqm on plan and exceeding 1.5 mtr and not exceeding 3.00mtr depth and getting out in any type of soil ( Except soft/loose soil ) complete all as specified and as directed by Engineer-in- charge. |
| 15 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick, in any type of soil complete all as specified and as directed by Engineer-in-Charge. |
| 16 | Removing excavated material/soils to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.5 mtr above the starting point, complete all as specified and as directed by Engineer-in-Charge. |
| 17 | Material and Labour sand cushioning, with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and as directed by Engineer-in-Charge. (Note:- Punned thickness shall be considered for payment purpose) |
| 18 | Supply and laying Best quality, locally available, sub class ‘B’ burnt clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed by Engineer-in-Charge. |
| 19 | Supply and Laying in replacement GI tubing 40mm bore Light grade with all fittings such as clamps laid in trenches or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'. |
| 20 | Supply and Laying in replacement GI tubing 50mm bore light grade with all fittings such as clamps laid in trenchs or fixed on wall along pole including fixing arrangement , nut bolts, clamps etc.complete for protection of electic cable / strip complete all as specified and as directed by Engineer - in charge. Note : Excavation and earth work shall be measured and paid seperately under appropriate items of Schedule'A'. |
| 21 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 50 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 22 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 35 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 23 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 24 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 25 Sqmm 3.50 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 25 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 10 Sqmm 2 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 26 | Supply and laying or fixing or laid in trenches/ ducts/ through pipes/ in floors / under roads/ hard standing /along poles and testing LT cable XLPE, PVC insulated screened, bedded, galvanised steel strip or wire armoured cable (heavy duty) 1100 volt grade with aluminium conductor having cross sectional area 16 Sqmm 4 core conforming to IS-7098 (Part-I -1988) complete all as specified and as directed by Engineer-in-Charge. (Excavation and earth work, sand cushioning & GI pipe shall be measured and paid for separately) |
| 27 | Material and labour in replacement for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 25mm x 4mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) Earth continuity of GI strip 25mm x 4mmincluding protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 28 | Material and Labour in replacement for Earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6 mm thick burried directly in ground to depth of pit not less than 2.25 m below normal ground level with top edge of the plate not less than 1.5 m below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal / coal dust and common salt filling in alternate layers and connected to galvanised earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of GI or steel including GI protection pipe 15mm dia light grade upto the extent of 7.5 metre and connecting to earthing test point, main switch board including GI pipe 20 mm dia medium grade for watering, MS funnel and bringing out the watering pipe upto 30 cm above the normal ground level plugged at top including all fitting including PCC earth pit with PCC 1:2:4 type B-1 using 20mm graded stone aggregate and RCC pit cover including necessary earthwork and excavation in any type of soil complete all as specified as shown in electrical plate No 3 of SSR Part-I and testing on completion. Note:- (i) Earth continuity of GI wire 4 mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 29 | Supply and fixing in replacement of automatic street-light control switch, complete with infrared sensor-based nature switch and Voltage Monitoring System (VMS), operating on ambient light (lux) levels, including suitable power contactors, MCBs and supporting terminals, all housed in a pole/wall-mountable enclosure made of rust-proof, electric-shock-proof, termite-proof and fire-retardant (FR) grade special moulding compound conforming to IP-54 protection. The contactors, MCBs, terminals and internal circuit wiring shall be suitably rated to control a total connected load of 25 kW, equally distributed over three phases, 415 Volts AC, including all necessary interconnections, wiring, glands, lugs, fixing arrangements and accessories, complete all as specified and directed by the Engineer-in-Charge. |
| 30 | Supply, fixing and laying in replacement and/or drawing through existing pipes/conduits, two runs of 6.00 sq mm single-core, stranded aluminium conductor, FRLS PVC-insulated, unsheathed cable, 1100 Volts grade,ISI Marked conforming to IS 694, including all necessary connections, complete all as specified and directed by the Engineer-in-Charge. Notes:-(i) two runs of 6.00 sq mm single-core, stranded aluminium conductor, FRLS PVC-insulated, unsheathed cable, 1100 Volts grade,ISI Marked shall be measured as one length. |
| 31 | Supply, fixing and laying in replacement and/or drawing through existing pipes/conduits, two runs of 4.00 sq mm single-core, stranded aluminium conductor, FRLS PVC-insulated, unsheathed cable, 1100 Volts grade,ISI Marked conforming to IS 694, including all necessary connections, complete all as specified and directed by the Engineer-in-Charge. Notes:-(i) two runs of 4.00 sq mm single-core, stranded aluminium conductor, FRLS PVC-insulated, unsheathed cable, 1100 Volts grade,ISI Marked shall be measured as one length. |
| 32 | Supply, fixing and laying in replacement and/or drawing through existing pipes/conduits, two runs of 1.5 sq mm single-core, stranded aluminium conductor, FRLS PVC-insulated, unsheathed cable, 1100 Volts grade,ISI Marked conforming to IS 694, including all necessary connections, complete all as specified and directed by the Engineer-in-Charge. Note:-(i) Two runs of 1.5 sq mm single-core, stranded aluminium conductor, FRLS PVC-insulated, unsheathed cable, 1100 Volts grade,ISI Marked shall be measured as one length. |
| 33 | Material & Labour for PCC 1:4:8 , Type - D2, using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 34 | Material & Labour for PCC 1:3:6 , Type C2 , using 40mm graded stone aggregates using 40mm graded stone aggregates as in foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material & Labour for PCC 1:2:4 type B1 using 20 mm graded stone aggregates as in lintel upto 1.5m clear span, cills, steps; seismic and other similar bends, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and thelikeincluding weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. |
| 36 | Material and Labour for Boring of holes under road, pavement, hard standing by using ultra sounding technique suitable for 0.4 mpa working pressure trenchless technology , with and including Galvanised Iron light grade 100 mm dia pipe all as specified and directed by Engr-in-Charge. Note: The rate of Galvanised Iron light grade 100 mm dia pipe is included in this item and nothing shall be paid extra on this account |
| 37 | Supplying and fixing in replacement 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including4mm suspension wire, one twin core cable flat or circular of size 10 sqmm complete all as specified and directed by Engineer-in-Charge. |
| 38 | Supply and fixing in replacement two single core 2.5 Sqmm FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked complete all as specified and directed by the Engineer-in-Charge. Note:-(i) Two runs of 2.5 Sqmm single core FRLSH PVC insulated unsheathed with multistranded copper conductor cable 1100 volts grade ISI Marked shall be measured as one length. |
| 39 | Supply and fixing in replacement 3-core, 1.5 sq mm, 1100-volt grade, FRLS PVC insulated and PVC sheathed, stranded copper conductor round flexible cable, drawn through steel tubular street-light pole and street-light arm for connection from junction box to LED street-light luminaire, including making connections at both ends with suitable lugs, ferrules and all necessary accessories, complete all as specified and directed by the Engineer-in-Charge. |
| 40 | Supply and fixing in replacement MCB SP 6 to 32 Amps, 230 volts , AC supply , rupturing capacity not less than 10KA,' C' Curve ,ISI Marked, with and including necessary attachment , thimbles etc complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply and fixing in replacement MCB SPN 32 Amps 10 KA 'C' curve 240V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge. |
| 42 | Supply and fixing in replacement MCB SPN 40 Amps 10 KA 'C' curve 240V AC, 50 Hz ,ISI Marked, with and including necessary attachment , thimbles etc. complete all as specified and directed by Engineer-in-charge. |
| 43 | Taking down existing security light fitting carefully from 9-metre/11-metre-high poles, security walls, security fencing and high-mast installations at any height, for repair, checking of internal wiring and rectification of faults, and refixing the same in position after completion of repairs, including testing and commissioning, complete all as specified and directed by the Engineer-in-Charge. |
| 44 | Material and labour for scraping and removing existing old paint, rust, scale and other foreign matter from the entire exposed surface of steel tubular poles, not exceeding 9 metres in height above ground level, including street-light arms / brackets, by means of wire brushes and other suitable tools, preparing the surfaces , with and including applying two coats of aluminium paint over with and including and applying one coat of red oxide zinc chrome primer , including marking pole numbers with synthetic enamel paint complete all as specified and directed by the Engineer-in-Charge. |
| 45 | Material and labour for scraping and removing existing old paint, rust, scale and other foreign matter from the surfaces of LT panel boards of any size, including thorough surface preparation and spray painting with two coats of synthetic enamel paint of approved colour, including masking and protection of all meters, instruments, indicators, switches and other fittings during painting and cleaning the same on completion, complete all as specified and directed by the Engineer-in-Charge. |
| 46 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 4 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 47 | Supply and fixing in replacement sheet metal enclousers made out of CRCA mild steel sheet , IP-43 protection, flush mounted with metal door, powder coated DB SPN 8 way 230 V AC with 200 Amp rated copper bus bar, Double Door, dust and vermin proof suitable for incorporation of MCBs / MCCBs/ Isolators etc.conforming to IS/IEC-61439-2:2011, BS-5484 complete all as specified and directed by Engineer-in-charge. Notes: (i)MCBs / MCCBs/ Isolators shall be measured and paid seperately under appropriate items.(ii) The rate of 200 Amps copper bus bar is included in this item and nothing shall be paid extra on this account. |
| 48 | Material and labour for painting PCC poles, including brackets and fittings, by thoroughly scrubbing and removing old and deteriorated paint, preparing the surfaces and applying two coats of cement-based paint, including providing alternate white and black colour strips up to 1.5 m height with two coats of synthetic enamel paint and painting the pole number in white lettering on a black background, complete all as specified and directed by the Engineer-in-Charge. |
| 49 | Supply and Fixing Bush Bar chamber of size 60cm x 60cm x 45 cm suitable of 3 phase 433 volts outdoor type made out of 3.15 mm thick M S sheet painted with two coats of synthtic enamel paint over with and including one coat of red Oxide zinc chrome primer , with 200 Amps rated aluminium busbar (4 Nos) PVC sleeves and colored (Red, yellow, blue & black) with locking arrangements , with and including angle iron stand of suitable size made with angle iron 40mm x 40mm x 6mm frame and legs grouted in PCC foundation 1:2:4 type B-1 using 20mm graded stone aggregates alongwith all necessary cable connections, lugs and cable galnd with and including two coats of synthtic enamel paint over one coat of red Oxide zinc chrome primer complete all as specified and as directed by Engineer-in charge: |
| 50 | Cutting and Trimming of trees branches from electric over head lines and clearing of 2 meter distance horizontal and vertical from outer edge of conductor including removing cut branches 50 Mtr (minimum) away from the place all as directed by Engr-in- Charge. Notes: 1. Contractor will ensure shut down on the feeder in writing before commencement of work on electrical lines2 Length of Each span shall be considered for measurment 40.00mtr. if the length of span less than 40.00mtr payment shall be made on the proportional rates as quoted by contractor for 40.00 mtr each span. |
| 51 | Supply and Fixing in replacement Electronic driver suitable for LED security light 25/30 watt as per required at site complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply and Fixing in replacement Electronic driver suitable for LED security light 45/48/60 watt as per required at site complete all as specified and directed by Engineer-in-Charge. |
| 53 | Dismantling and taking out insulators of any type and any size complete all as specified and directed by Engineer-in-Charge. |
| 54 | Taking down old unserviceable ACSR conductor of assorted sizes from existing overhead lines, including disconnection and removal from poles, complete all as specified and as directed by the Engineer-in-Charge.Notes:(a) The dismantled material shall become the property of the contractor and shall be removed from site accordingly. No credit shall be passed, and no payment shall be admissible towards the value of dismantled material or for any labour involved in its handling, stacking or transportation.(b) Underground cable and allied works shall be measured and paid for separately under relevant items.” |
| 55 | Dismantling and taking out cross-arms of M.S. channel or angle sections etc of any type/ size complete all as specified and directed by Engineer-in-Charge. |
| 56 | Dismantling GI Wire of any size and any type complete all as specified and directed by Engineer-in-Charge. |
| 57 | Supply , Fixing , commissioning and Testing Fabricated Factory made LT panel board CPRI approved outdoor type, double door, floor mounted of size 1.25 mtr x 1.2mtr x 0.45mtr suitable for 415 volts, 3 phase, 4 wire, 50HZ, AC supply system having bus bar chamber with insulated aluminiumr bus bars of rating 400 Amps for neutral, installed on porcelain insulators. The panel should be dust and vermin proof IP-54 class protection and made with 3.15 mm thick MS sheet duly epoxy powder coated , with and including 40mm x40mm x 6mm thick MS angle iron frame work, powder coated finis front opening type, back opening, including internal wiring with PVC insulated solid copper conductor cable, IS 694 marked, 1100 volts grade of appropriate size (but not less than 4.0sq mm), PCC work in 1:2:4 type B-1, using 20mm graded stone aggregates and comprising of the following :-Incoming:-(a) MCCBs 4 pole, 415 volts grade, 160 Amps rating and 35KA rupturning capacity, adjustable thermal setting No.- 01Outgoing:-(a) MCCBs 4 pole, 415 volts grade, 125 Amps rating and 25 KA rupturning capacity, adjustable thermal setting : 03 Nos.(b) MCB SPN 63 Amps 240 Volt and 10 KA rupturning capacity \\"C\\" Curve -06 Nos. (c) Voltmeter electronic, digital type, with selector switch 0-500 volts, AC, 50 Hz - 1 No.(d) Ammeter electronic, digital type, 0-400 amps, AC, 50 Hz - 1 No.(e) Current transformer200/5 amps rating, AC, 50 Hz - 3 Nos.(f) Phase indication LED lamps - 3 Nos. Note: Make and complete detailed drawings of the LT Panel shall be submitted to and approved by the GE prior to procurement / manufacture . The panel shall be executed strictly as per approved drawings and specifications complete all as specified and as directed by Engineer-in-charge. |
| 58 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6 buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including earth continuity GI strip 32mm x 6mm (upto test point from earth plate i.e. 7.5m min) by means of GI bolts/nuts/washersand including protected by 15mm dia GI light grade protection pipe from earth plate to test point, including making of test point. Earth plate shall be surrounded by packed layer of char coal/coke & salt all around bottom and top with alternative layer. 20mm GI mediumt grade pipe for watering (should be 10cm above GL) and including socket, plug, funnel, wire mesh, RCC cover and (including steel for cover) PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil , returning filling and disposal of surplus soil to a distance not exceeding 50m, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and and as directed by Engineer-in-charge. Note:- (i) Earth continuity of GI strip 32mm x 6mm including protection pipe up to 7.5 mtrs from earth electrode will be included in unit rate, complete all as specified and directed. (ii) The rate of earth work in soft/loose soil i.e. excavation, returing filling and removal, form work is included in this item and nothing shall be paid extra on this account. (iii) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (iv) The earth testing arrangement should be done by the contractor as per direction of Engineer-in-charge. |
| 59 | Taking down old unserviceable service cable/underground (UG) cable of any size, including removal of unserviceable bricks/PCC cable covers, complete all as specified and as directed by the Engineer-in-Charge.Notes:(a) Earth work such as excavation, returning filling and removal shall be measured and paid for separately under relevant items of Schedule 'A' BoQ..(b) Where new/old cable is laid along the same alignment/location, earth work such as excavation, returning filling and removal shall be measured and paid only once. No duplicate measurement shall be admissible in this regard. |
| 60 | Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender from total amount of Schedule 'A'/BOQ Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 08, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 16 daysAug 11, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 19 daysTender Documents
Download All (ZIP) ↓
Disclaimer