Defence Statutory Bodies & Commissions/Committees Closing in 16 days TDR #56500446

Tender For Repair / Maintenance Of Centrifugal Pumps, Booster Pump, Monoblock Pump And Starter At Parade Ground, Kabul Line And Adjoining Pump Houses Area In The Area Of Age (U) W/S-Ii Under Ge (U) Water Supply Delhi Cantt-10

Issued by Statutory Bodies & Commissions/Committees · New Delhi, Delhi
Tender Value
45 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
16 days left
EMD
90000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Centrifugal Pumps, Booster Pump, Monoblock Pump And Starter At Parade Ground, Kabul Line And Adjoining Pump Houses Area In The Area Of Age (U) W/S-Ii Under Ge (U) Water Supply Delhi Cantt-10

BOQ

Name of Work:- REPAIR / MAINT OF CENTRIFUGAL PUMPS, BOOSTER PUMP, MONOBLOCK PUMP AND STARTER AT PARADE GROUND, KABUL LINE AND ADJOINING PUMP HOUSES AREA IN THE AREA OF AGE (U) W/S-II UNDER GE (U) WATER SUPPLY DELHI CANTT-10
Sl. No. Item Description
1Demolition of cement concrete unreinforced, in ground floor or pavings below or above ground level from foundation of pump sets including removal of debris from site complete all as specified and as directed .
2M&L for PCC 1:2:4 type B-1 using 20 mm graded mechanically crushed stone aggregates as in foundation, sub base or mass concrete complete all as specified and as directed.
3Labour for Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out electric motor of following capacities from base plate of pump set after opening the nuts, bolts etc and transporting the motor to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed. (Note :- (i) If the contractor fails to repair the motor and pump within seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor. (ii) The contractor will open the Induction Motor/Pump at site only to assess the exect nature of reqpair required and material to be replaced.
45-15 HP
520-30 HP
640-50 HP
760-75 HP
890-125 HP
9Labour for opening the electric induction motor of following capacity including taking down/out the burnt winding wire , cleaning the slots, rewinding the motor with super enamalled copper winding wire of existing gauge ,weight etc. including all other insulating material to make it functional complete all as specified and as directed .(Note:- Copper winding wire of approprioate guage will be measured in supply only)
105-15 HP
1120-30 HP
1240-50 HP
1360-75 HP
1490-125 HP
15Supplying and Fixing in replacement of Motor Terminal Box of following capacity.
165-15 HP
1720-30 HP
1840-50 HP
1960-75 HP
2090-125 HP
21Supplying and Fixing in replacement of Motor Terminal Connection Plate of following capacity
225-15 HP
2320-30 HP
2440-50 HP
2560-75 HP
2690-125 HP
27Supplying and Fixing in replacement of CI Sleeve on Bearing Housing of following capacity
285-15 HP
2920-30 HP
3040-50 HP
3160-75 HP
3290-125 HP
33Supply and Fixing in replacement of Motor Cooling Fan as per site requirement for any size of motor made of PVC/ Aluminium complete.
34Supply and Fixing in replacement of PVC cooling pipe with bush and addeptor complete.
35Supply and Fixing in replacement of Brass air cock as per site requirement complete all as specified and directed.
36Labour for Disconnecting and De-coupling the Centrifugal pump of following capacity from foundation after opening /cutting the rusted nuts, bolts etc including transporting the pump to workshop for repair and back, re-installed at existing position after repair and providing new MS nuts, bolts,packing flange etc including testing complete all as specified and as directed. (Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.)
375-15 HP
3820-30 HP
3940-50 HP
4060-75 HP
4190-125 HP
42Opening the centrifugal pump of following capacity, repairing the same by replacing the unserviceable spare parts including machining work and re-assembling the same in original position complete all as specified and as directed.(Note:- Spare Parts required shall be measured & paid spaerately.)
435-15 HP
4420-30 HP
4540-50 HP
4660-75 HP
4790-125 HP
48Supply Only in replacement of spare parts for Centrifugal pump of 5-15 HP Capacity.
49CI Impeller
50Pump shaft SS (AISI-410)
51CI Casing wearing (Neckring)
52CI interstage ring
53CI stuffing box bush
54CI Gland Plate
55Eye bolt with nut
56CI Shaft sleeve
57Gasket Packing Set
58Gland packing champion
59Impeller key
60coupling key
61water liquid deflector
62CI bearing cartridge DE/NDE
63CI bearing plate
64Coupling nut
65MS Stud with nut
66Labour only for Remetling of pump shaft, turning and balancing
67Supply Only in replacement of spare parts for Centrifugal pump of 20-30 HP Capacity.
68CI Impeller
69Pump shaft SS (AISI-410)
70CI Casing wearing (Neckring)
71CI interstage ring
72CI stuffing box bush
73CI Gland Plate
74Eye bolt with nut
75CI Shaft sleeve
76Gasket Packing Set
77Gland packing champion
78impeller key
79coupling key
80Water liquid deflector
81CI bearing cartridge DE/NDE
82CI bearing plate
83Mechanical Seal
84coupling nut
85MS Stud with nut
86Labour only for Remetling of pump shaft, turning and balancing
87Supply Only in replacement of spare parts for Centrifugal pump of 40-50 HP Capacity.
88CI Impeller
89pump shaft SS (AISI-410)
90CI Casing wearing (Neckring)
91CI interstage ring
92CI stuffing box bush
93CI Gland Plate
94Eye bolt with nut
95CI Shaft sleeve
96Gasket Packing Set
97Gland packing champion
98Impeller key
99coupling key
100water liquid deflector
101CI bearing cartridge DE/NDE
102CI bearing plate
103Coupling nut
104MS Stud with nut
105Labour only for Remetling of pump shaft, turning and balancing
106Supply Only in replacement of spare parts for Centrifugal pump of 60-75 HP Capacity.
107CI Impeller
108pump shaft SS (AISI-410)
109CI Casing wearing (Neckring)
110CI interstage ring
111CI stuffing box bush
112CI Gland Plate
113Eye bolt with nut
114CI Shaft sleeve
115Gasket Packing Set
116Gland packing champion
117Impeller key
118Coupling key
119Water liquid deflector
120CI bearing cartridge DE/NDE
121CI bearing plate
122Coupling nut
123MS Stud with nut
124Labour only for Remetling of pump shaft, turning and balancing
125Supply Only in replacement of spare parts for Centrifugal pump of 90-125 HP Capacity.
126CI Impeller
127pump shaft SS (AISI-410)
128CI Casing wearing (Neckring)
129CI interstage ring
130CI stuffing box bush
131CI Gland Plate
132eye bolt with nut
133CI Shaft sleeve
134Gasket Packing Set
135Gland packing champion
136impeller key
137coupling key
138water liquid deflector
139CI bearing cartridge DE/NDE
140CI bearing plate
141coupling nut
142MS Stud with nut
143Labour only for Remetling of pump shaft, turning and balancing
144Supply only in replacement of water seal/ Oil seal for any size of pump complete all as specified and directed.
145Supply only in replacement of Oring set for any size of pump
146Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out monoblock pump set capacity upto 10 HP from foundation/base plate of pump set after opening the nuts, bolts etc and transporting the pump to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed . (Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.)
147Opening the monoblock motor and pump upto capacity 10 HP , taking down/out the burnt winding wire and cleaning the slots including rewinding the monoblock motor with super enamelled copper winding wire of existing gauge ,weight etc. and repairing the pump by replacing the unserviceable spare parts including machining work and re-assembling the same in original position including all other insulating material complete all as specified and as directed.(Note :- Copper winding wire of appropriate gauge and spare parts of pump shall be measured and paid separetely.)
148Supply Only in replacement of spare parts for Monoblock pump of upto 10 HP Capacity.
149CI Impeller
150Mechanical Seal
151Water Seal
152GM Shaft sleeve
153Gland packing sheet
154water liquid deflector
155impeller Nut
156MS Stud with nut
157Disconnecting of electrical connections from panel board including disconnecting the cable leads from the motor terminal box and taking down/out dewatering motor pump vertical type/ centrifugal pump set from underground sump or from base plate of capacity upto 2.5 HP after opening the nuts, bolts etc and transporting the pump to workshop for repair and back, re-installed after repair including testing complete all as specified and as directed .(Note:- Copper winding wire and spare parts of motor and pump shall be measured and paid separetely. (Note :- If the contractor fails to repair the motor and pump within the seven days given to him the same will be got repaired through other agency by calling spot quotation at his risk and cost. This shall be in addition to penalty as mentioned in clause 7.1 of Particular Specification. The decision of the Accepting officer in this regard shall be final concluding and binding on the contractor.)
158Opening of dewatering motor and pump/ centrifugal pump set of capacity upto 2.5 HP including taking down/out the burnt winding wire , cleaning the slots ,rewinding the motor with super enamelled copper winding wire of existing gauge ,weight etc. and repairing the pump by replacing the unserviceable spare parts including machining work and re-assembling the same in original position including all other insulating material complete all as specified and as directed.(Note :- Copper winding wire of appropriate gauge and spare parts of pump shall be measured and paid separetely).
159Supply Only in replacement of spare parts of upto 2.5 HP Capacity dewatering motor and pump/ centifugal pump set .
160CI Impeller-501/503
161Maintenance kit -501/503
162Cable kit with float switchfluid level controller-501/503 SE
163Suction plate
164Plug for motor cable
165Installation kit-ama porter 500
166stainless steel rotor sleeve
167stainless steel rotor shaft -410
168Remetailing of rotor & turning/grinding
169GM suction ring
170Prrof jointing of submersible cable
171CI suction chamber
172Repairing of stamping of stator
173Mechanical seal set
174O ring set
175Insulation kit
176Supplying and assembling super enamelled copper winding wire of appropriate gauge suitable upto 125 HP capacity Motor complete all as specified and directed.
177Supply and Fixing in replacement of Ball bearing No 6305 or equivalent as per sample complete all as specified and as directed.
178Supply and Fixing in replacement of Ball bearing No 6306 or equivalent as per sample complete all as specified and as directed.
179Supply and Fixing in replacement of Ball bearing No 6307 or equivalent as per sample complete all as specified and as directed.
180Supply and Fixing in replacement of Ball bearing No 6308 or equivalent as per sample complete all as specified and as directed.
181Supply and Fixing in replacement of Ball bearing No 6309 or equivalent as per sample complete all as specified and as directed.
182Supply and Fixing in replacement of Ball bearing No 6310 or equivalent as per sample complete all as specified and as directed.
183Supply and Fixing in replacement of Ball bearing No 6311 or equivalent as per sample complete all as specified and as directed.
184Supply and Fixing in replacement of Ball bearing No 6312 or equivalent as per sample complete all as specified and as directed.
185Supply and Fixing in replacement of Ball bearing No 6313 or equivalent as per sample complete all as specified and as directed.
186Supply and Fixing in replacement of Ball bearing No 6314 or equivalent as per sample complete all as specified and as directed.
187Supply and Fixing in replacement of Ball bearing No 6315 or equivalent as per sample complete all as specified and as directed.
188Supply and Fixing in replacement of double Ball bearing No 3307 complete all as specified and as directed.
189Supply and Fixing in replacement of double Ball bearing No 3309 complete all as specified and as directed.
190Supply and Fixing in replacement of double Ball bearing No 21309 complete all as specified and as directed.
191Supply and Fixing in replacement of Roller bearing NU-313 complete all as specified and as directed.
192Supply and Fixing in replacement of Roller bearing NU-314 complete all as specified and as directed.
193Supply and Fixing in replacement of Roller bearing NU-316 complete all as specified and as directed.
194Supply and Fixing in replacement of Roller bearing NU-318 complete all as specified and as directed.
195Supply and fixing spare tyre for coupling type as under, after taking down/out as existing at site complete all as specified and as directed.
196type TC/P/011
197type TC/P/013
198type TC/P/014
199type TC/P/015
200type TC/P/017
201type TC/P/018
202Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 5-20 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed. (Note:- (i) Number plate and other details on the motor will NOT be painted and must be kept neat and clean while painting. (ii) Painting will be done by hand brush and No spray gun will be used while painting in site.)
203Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 25-50 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed. (Note:- (i) Number plate and other details on the motor will NOT be painted and must be kept neat and clean while painting. (ii) Painting will be done by hand brush and No spray gun will be used while painting in site.
204Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 60-75 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed. (Note:- (i) Number plate and other details on the motor will NOT be painted and must be kept neat and clean while painting. (ii) Painting will be done by hand brush and No spray gun will be used while painting in site.
205Material and labour for painting Two coat of synthetic enamel paint as per existing pattern or scheme, on centrifugal pump & motor of any capacity rating 90-125 HP, Scratching the rusted and suction/ delivery pipeline including NRV and sluice valve, MS Base channel including preparation of surfaces by scratching and removing the rust complete all as specified and as directed. (Note:- (i) Number plate and other details on the motor will NOT be painted and must be kept neat and clean while painting. (ii) Painting will be done by hand brush and No spray gun will be used while painting in site.
206Supply and Fixing in replacement MS base channel of size as exists including cutting, welding and making hole including applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
207Supply and fixing bearing plate bolt of size 8 mm dia , 100 mm long after taking down/out plate as existing at site complete all as specified and as directed.
208Supply and Fixing in replacement of MS foundation bolts with nuts and washers, size 20mm dia , 250 mm long complete all as specified and as directed.
209Supply and fixing in replacement 3 pole power contactor type ML-1.5, 415 Volts, 50 HZ range 25 Amps complete all as specified and as directed.
210Supply and fixing in replacement 3 pole power contactor type ML-2, 32 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
211Supply and fixing in replacement 3 pole power contactor type ML-3, 40 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
212Supply and fixing in replacement 3 pole power contactor type ML-4, 70 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
213Supply and fixing in replacement 3 pole power contactor type ML-6,110 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
214Supply and fixing in replacement 3 pole power contactor type ML-10, 200 Amps, 415 Volts, 50 HZ complete all as specified and as directed.
215Supply and fixing in replacement of Thermal Overload Relay ML-1 10 to 16 complete all as specified and as directed.
216S & F in replacement of Bimetal over load relay type MN 2, relay range 14-23 Amp complete all as specified and as directed.
217S & F in replacement of Bimetal over load relay type ML 2/3, relay range 20-32 Amps complete all as specified and as directed.
218S & F in replacement of Bimetal over load relay type ML 2/3, relay range 28-42 Amps complete all as specified and as directed.
219S & F in replacement of Bimetal over load relay type MN 5, relay range 45-75 Amps complete all as specified and as directed.
220S & F in replacement of Bimetal over load relay type ML 5, relay range 66-110 Amps complete all as specified and as directed.
221S & F in replacement of Bimetal over load relay type MN-12, CT operated relay range 90-150 Amps complete all as specified and as directed.
222Supply and fixing in replacement Amp Meter Analog type 0 to 60 Amp of size 96 x 96 mm complete all as specified and as directed.
223Supply and fixing in replacement Amp Meter Analog type 0 to 100 Amp of size 96 x 96 mm complete all as specified and as directed.
224Supply and fixing in replacement Amp Meter Analog type 0 to 200 Amp of size 96 x 96 mm complete all as specified and as directed.
225Supply and fixing in replacement of Indicating light RYB LED type complete all as specified and as directed.
226Supply and fixing in replacement Amp meter selector switch complete all as specified and as directed.
227Supply and fixing in replacement Volt meter selector switch complete all as specified and as directed.
228Supply and fixing in replacement Amp Meter Digital type of size 96 x 96 mm complete all as specified and as directed.
229Supply and fixing in replacement Volt Meter digital type of size 96 x 96 mm complete all as specified and as directed.
230Supply and fixing in replacement FRLS PVC insulated industrial grade copper conductor wire of following size, 1100 volts complete all as specified and as directed.
2314.00 sqmm, single core
2326.00 sqmm, single core
23310.00 sqmm, single core
23416.00 sqmm, single core
23525.00 sqmm, single core
23635.00 sqmm, single core
23750.00 sqmm, single core
238Supply and fixing in replacement PVC insulated FRLS round sheathed copper conductor wire of 2.5 Sqmm, 3 core, 1100 volts complete all as specified and as directed.
239Supply and fixing in replacement of Thermal contactor type MNX-18, in electric panel of motor complete all as specified and as directed.
240Supply and fixing in replacement of Thermal contactor type MNX-25 in electric panel of motor complete all as specified and as directed.
241Supply and fixing in replacement of Thermal contactor type MNX-32 in electric panel of motor complete all as specified and as directed.
242Supply and fixing in replacement of Thermal contactor type MNX-40 in electric panel of motor complete all as specified and as directed.
243Supply and Fixing in replacement Electronics Timer 3-30 seconds, Type ST100, 415 volts, complete all as specified and as directed.
244Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 100 Amps with breaking capcity 16 KA , 415 volts, complete all as specified and as directed.
245Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 160 Amps with breaking capcity 25 KA , 415 volts, complete all as specified and as directed.
246Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 200 Amps with breaking capcity 36 KA , 415 volts, complete all as specified and as directed.
247Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 250 Amps with breaking capcity 36 KA , 415 volts, complete all as specified and as directed.
248Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 400 Amps with breaking capcity 50 KA , 415 volts, complete all as specified and as directed.
249Supply and fixing in replacement moulded case circuit breakers (MCCB), 3 pole, 630 Amps with breaking capcity 50 KA , 415 volts, complete all as specified and as directed.
250Supply and fixing in replacement of fully automatic star delta starter type complete siutable for 10 HP
251Supply and fixing in replacement of fully automatic star delta starter type complete siutable for 30 HP
252Supply and fixing in replacement of fully automatic star delta starter type complete siutable for 50 HP
253Supply and fixing in replacement of fully automatic star delta starter type complete siutable for 75 HP
254Supply and fixing in replacement of fully automatic star delta starter type complete siutable for 125 HP
255Supply and Fixing in replacement Automatic phase sequence correctot suitable for 51-75 HP with sheet metal encloser and indicator lamp output/input, suitable for 3 Phase electric motor with Automatically protection against single phaseing voltage, unbalanced and low/High voltage with time delay.
256Supply and Fixing in replacement Automatic phase sequence correctot suitable for 76-100 HP with sheet metal encloser and indicator lamp output/input, suitable for 3 Phase electric motor with Automatically protection against single phaseing voltage, unbalanced and low/High voltage with time delay.
257Supply and fixing in repair copper terminals lugs (Thimbles) ring type medium duty for following items :-
25816 mm
25925 mm
26035 mm
26150 mm
262Supply and fixing, install, test and commissioning of LT Feeder pillar box outdoor type totally enclosed with front and rear opening hinged doors with canopy sloped top projected and raised platform of suitable sizes weather dust vermin proof made out of 3.15mm thick CRCA sheet, factory made (CPRI approved manufacturer) powder coated painted as approved colour, copper bus bar suitable for 3 phase 4 wire LT, AC, 50Hz, 433 volts, 350 Amps capacity RYBN insulated with sleeved insulation complete with multifunctional meter LED type by showing Amps, volts, frequency etc along with suitable size of CT on outgoing, indicating lamp RYB, complete internal wiring with suitable size of PVC insulated copper conductor cable, including cable glands and lugs for incoming and out going LT cables as per required sizes, PCC platform made out of 1:2:4 type B1 and pedestal of 30 cm height from GL with suitable nut, bolts, washers etc., all as specified and directed for suitable to in and including accomodate the following items and all as specified and directed by dismantling exisiting unserviceable LT panel complete. (a) 01 x 200A 36 KA 4 Pole - Incoming MCCB's (b) 02 x 63A 25 KA 3 Pole - Outgoing MCCB's (c) 01 x 63 Amps 3 Phase Auto Phase Sequence Corrector(d) 02 x Thermal Over load relay - outgoing (e) 02 x ST 100 Timer - outgoing(f) ML2 FASD (Heavy duty 35 HP relay range 13-21 A) - 02 Nos for outgoing(Note :- Contractor shall be take approval of Accepting Officer for panel drawing before fabrication work.)
263Supply and fix in Replacement of Earthing complete with galvanised iron earth plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of the plate not less than 1.5mtr below normal ground level, connected to galvanised iron strip 32 x 6mm as earth continuity conductor connected to earth plate by means of GI light bolt nuts, check nuts and washers of including providing earth wire protection pipe GI light grade 40mm bore from earth plate to main switch board/panel, watering pipe 40mm bore GI pipe medium grade with wire mesh and funnel at top, earth pit of PCC in 1:2:4 type B-1, with RCC cover 1:2:4 type B-0 using MS TMT 8mm dia @ 150 c/c both way with suitable handle, angle iron frame made out of angle iron of size 40 x 40 x 4mm, including adequate quantity of charcoal dust and salt in alternate layers all around the earth plate, including excavation and earth work in any type of soil complete all as per electrical plate No 3 of SSR Part-I (2009) connected to earthing test point including test point made out of 40 x 3mm GI flat iron, all as specified and indicated including testing on completion, including taking down old unserviceable earthing, for machinery/ equipment installed at power house/sub station complete all as specified and directed.
264M & L for earthing in replacement GI plate 60×60cm ×3.15mm thick electrode and 32x6mm galvanised strip as earthing lead thick buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level, connected to copper strip of size 25x4mm as earth lead by means of bolts, nuts and washers madeout of copper or tinned brass and protection GI pipe of 40mm dia all as specified and testing complete including earthwork, PCC chamber, RCC chamber cover with handle GI watering pipe 20mm dia, GI funnel with wire mesh, magnesium sulphate, salt, charcoal, lugs etc and method of earthing shall be as per plate No :3 of SSR part -I.
265An amount of Rs 2,34,079.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56500446
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 45 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Centrifugal Pumps, Booster Pump, Monoblock Pump And Starter At Parade Ground, Kabul Line And Adjoining Pump Houses Area In The Area Of Age (U) W/S-Ii Under Ge (U) Water Supply Delhi Cantt-10
Basic Detail
Tender No GE/WS/Token No-34 OF 2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 08 Aug 2026
Finance
Tender Value 45 Lakhs
Tender Fee 500
EMD 90000
Exemption Available
Document List
a0caa59d-a1ba-43f4-8647-116d30747c5c.html
BOQ_872440.xls
tender.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 16 days
Aug 08, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 18 days

Tender Documents

Download All (ZIP) ↓
html

a0caa59d-a1ba-43f4-8647-116d30747c5c.html

xls

BOQ_872440.xls

pdf

tender.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail