Tender For Repair/Maintainance/Replacement Of Water Pipe Line At Moude Road Area, Arjan Vihar, Carriappa Vihar Area, Pratap Chowk, Khyber Lines, Manekshaw Centre Pump House, Baird Place In The Area Of Age(U) Water Supply No-Ii, Under Ge(U) Water Supp
Tender Overview
Project Description
Tender for Repair/Maintainance/Replacement Of Water Pipe Line At Moude Road Area, Arjan Vihar, Carriappa Vihar Area, Pratap Chowk, Khyber Lines, Manekshaw Centre Pump House, Baird Place In The Area Of Age(U) Water Supply No-Ii, Under Ge(U) Water Supply, Delhi Cantt-10.
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 metre depth and getting out in any type of soil for taking out/laying of pipe complete all as specified and as directed |
| 2 | Returning filling in, including spreading, leveling, watering and well ramming in layers not exc. 25 cm thick complete all as specified and directed. |
| 3 | Removal of excavated material from site to a distance not exceeding 50 meters away and depositing where directed at a level not exceeding 1.5 meters above the starting point complete all as specified and directed. |
| 4 | Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-2 (with 40 mm graded aggregate) in foundations,filling and mass concrete complete including making good the existing surface complete all as specified and directed. |
| 5 | Taking up GI/CI/MS Pipes including all fitting of the following sizes as specified and directed by Engineer-in-Charge :- |
| 6 | 80 mm bore |
| 7 | 100 mm bore |
| 8 | 150 mm bore |
| 9 | 200 mm bore |
| 10 | Supply, laying jointing, testing of DI pipe with class-K-7 spigot socketed ends, conforming to IS-8329 laid in trenches including providing route indicators of suitable height and laying at spacing of @ 50m center to center at GL mentioning name of contractor, date of execution & CA No with name of work & rubber gasket (Tyton) joints with jointing material & route indicators of the following sizes including taking down of existing CI/DI pipe complete all as specified and directed by Engineer-in-Charge. Note 1: - Excavation & earth work shall be measured and paid seperately under respective items of BOQ.Note 2:- Contractors will provide route indicators mild steel body with top 150 mm plate 3mm thick and height not less than 300mm above finished GL at suitable intervals as directed by EIC. Cost of route indicators shall be deemed included in quoted unit rates.Note 3:- Layout plan for laying of DI pipe shall be given by EIC in writing. |
| 11 | 80 mm bore |
| 12 | 100 mm bore |
| 13 | 150 mm bore |
| 14 | 200 mm bore |
| 15 | Material and Labour for DI fittings/specials like MJ Collars, bends any type radius and angle, Tee pieces single branch 'Y' junction, double branch, cross(all sockets or socket and spigot) collars, DI connecting pieces one end flanged and other end spigot / socket, reducers / bell mouth pieces one end flanged and other end tapering as bell mouth for the size upto 250 mm dia bore. |
| 16 | Material and labour for Rubber Gasket Joint (Tyton Joint) including jointing material for DI/CI pipe of following size/bore :- |
| 17 | 80 mm bore |
| 18 | 100 mm bore |
| 19 | 150 mm bore |
| 20 | 200 mm bore |
| 21 | Material and labour including jointing and testing of cast iron sluice valves class PN-1.0 PD short body, conforming to IS:14846-2000, flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed.Note- (i) Flanged joints complete with jointing material shall deemend to be included in the unit rate of this item. |
| 22 | 80 MM bore |
| 23 | 100 MM bore |
| 24 | 150 MM bore |
| 25 | 200 MM bore |
| 26 | Supply and fixing jointing and testing of Cast Iron Non-Return Valve without bypass arrangement, swing type, confirming to IS-5312, flanged ends pressure rating PN 1.0 including taking out old unsv NRV from the existing place of following sizes:- Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.(ii) Genuine PV's & MTC of vavle be produced by contractor alongwith RAR for payment.) |
| 27 | 80 mm dia |
| 28 | 100 mm dia |
| 29 | 150 mm dia |
| 30 | Material and labour for run lead joint including jointing material for cast iron pipe of following size/bore :- |
| 31 | 80 mm bore |
| 32 | 100 mm bore |
| 33 | 150 mm bore |
| 34 | 200 mm bore |
| 35 | Supply and Laying of GI Pipe medium grade ISI mark including all fittings in old/new positios in trenches / wall / floor complete and making good the distributed surfaces as per existing as directed of following sizes. Cost of taking up of old steel tubing shall be deemed to be included in quoted unit rate.(Note:- Excavation and earth work will be measured and paid separately). |
| 36 | 15 MM bore |
| 37 | 20 MM bore |
| 38 | 25 MM bore |
| 39 | 40 MM bore |
| 40 | 50 MM bore |
| 41 | S&F Gun metal gate valve with iron wheel head screwed both ends for iron pipe and fixed ISI Marked as per IS 778 of following sizes including taking out unserviceable gate valve bore of pipe of following sizes complete all as specified and directed :- |
| 42 | 15 MM bore |
| 43 | 20 MM bore |
| 44 | 25 MM bore |
| 45 | 40 MM bore |
| 46 | 50 MM bore |
| 47 | Supply and installation of flanged ends strainer/dirt box, PN-10 with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. |
| 48 | 80 mm bore |
| 49 | 100 mm bore |
| 50 | 150 mm bore |
| 51 | 200 mm bore |
| 52 | Supply and installation of flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. |
| 53 | 50 mm bore |
| 54 | 80 mm bore |
| 55 | 100 mm bore |
| 56 | 150 mm bore |
| 57 | 200 mm bore |
| 58 | Supply and Fixing in replacement of CI Foot valve of following size , Flanged ends, Swing type opration with rubber sheet as per IS-4038 including taking out unserviceable of following sizes complete all as specified and directed by Engineer-in-Charge. Note :- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this items. |
| 59 | 100 MM bore |
| 60 | 150 MM bore |
| 61 | Construction of valves pit chamber having internal dismention 900mm x 900mm x 900 mm (internal height) using PCC (1:4:8)40 mm graded stone aggregate for foundation 15 cms thick, 23 cm thick wall in CM (1:4) 10 mm thick rendering all around the brick work with 1:6 cement mortar PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm thick MS top sheet cover with locking arrangement including 50 mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as specified and as directed by the Engineer-in-Charge |
| 62 | Supply & Fix float valve high pressure of PTMT with epoxy coated Aluminum rod and High density plastic Ball screwed for iron pipe , including taking out float valve of following sizes complete all as specified and directed by Engineer-in-Charge. |
| 63 | 15 MM bore |
| 64 | 20 MM bore |
| 65 | 25 MM bore |
| 66 | Material and labour for painting two coat of synthetic enamel paint as per existing pattern on pipe surface/header connection including preparation of surfaces by scratching and removing the rust, applying one coat red oxide primer complete all as specified and as directed |
| 67 | M&L for removing weeds and wild grass inside the installations using chemical spray and trimming trees and unwanted plants using petrol operated Tree/Grass cutting tools and dressing of the surface by scrapping high patches and filling low patches with the scrapping soil to give an even and neat look to the site and disposing off all the unwanted grass, bushes and debris all as directed by the Engineer-in-Charge. |
| 68 | Material and labour for MS works of any sizes of angles irons/flat iron/MS sheet works for U/S Sumps for making grills and stair steps etc. complete all as specified and directed by engr-in-charge |
| 69 | Demolation in concrete cement in ground floors and paving(Road cutting) not exc 15cm thickness (Below or above the ground level) all as per specified and as directed. |
| 70 | M & L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for including fair finish even and fair to exposed surfaces without using extra cement complete all as specified and as directed |
| 71 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoin jambs pillars etc. |
| 72 | Brick work in CM (1:4) with sub class 'B' bricks above ground level and not exceeding 1.5 mtr in height from ground level including footing complete all as specified and directed. |
| 73 | M&L Rendering 10 mm thick with cement plaster (1:4) on brick walls for finishing the surface fair and even complete all as specified and directed by engr-in-charge |
| 74 | M&L Machine pressed precast concrete interlocking paverblocks any shape and size confirming to IS 15658-2006 of 60 mm thick, M-40 Grade with grey cement and no pigments, over 25 mm thick sand cushioning complete all as specified and as directed. |
| 75 | Supplying, laying, jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes 8mm thick laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes :- (Note:- (i) MS Flanges incl fabrication work will be measured and paid separately.(ii) Excavation and earth work will be measured and paid separately. |
| 76 | 80 MM bore |
| 77 | 100 MM bore |
| 78 | 150 MM bore |
| 79 | Supply and fixing in replacement of MS flange, 16mm thick duly welded with flange joint including nuts bolts, washer, Rubber or fiber board gasket joint of following sizes:- |
| 80 | 80 MM bore |
| 81 | 100 MM bore |
| 82 | 150 MM bore |
| 83 | Supplying and fixing in replacement of Digital water level indicator for under ground/Semi underground water tank reservior in multistage (10 stages) length & features of alarm on low and high levels with indications including required cable to make it fully serviceable/funcional as directed by Engf-in Charge.Note:all connected item of indicator shall deemed to be included in quoted unit rate |
| 84 | M&L for free & Shrub prunning / trimming inside pump house permises.(Note:- Each Job includes all trees & Shrubs of one pump house.) |
| 85 | An amount of Rs 2,23,160.00 shall be deducted from BOQ on account of schedule of credit Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender