Tender For Special Repairs To Leaky Roof, Flooring, Doors, Windows And Water Supply Arrangements In Hsc At Kottaiyur In Tiruvannamalai District.
Tender Value
7.77 Lakhs
Estimated cost
Bid Submission
31 Jul 2026
0 days left
EMD
7770
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tiruvannamalai → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Special Repairs To Leaky Roof, Flooring, Doors, Windows And Water Supply Arrangements In Hsc At Kottaiyur In Tiruvannamalai District.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and Clearing away and carefully stacking materials for reuse for pressed tiles and weathering course etc., complete complying with standard specifications and as directed by the departmental officers |
| 2 | Dismantling and Clearing away and carefully stacking materials for reuse for terracing work in roof or floor etc., complete complying with standard specifications and as directed by the departmental officers |
| 3 | Dismantling and Clearing away and carefully stacking materials for reuse for Floor finish and dadooing walls in cement mortar with mosaic tiles / glazed tiles / cuddapah slabs etc., complete complying with standard specifications and as directed by the departmental officers |
| 4 | Dismantling and Clearing away and carefully stacking materials for reuse for Doors & windows including removal of frames, hinges and fastenings etc., complete complying with standard specifications and as directed by the departmental officers |
| 5 | Dismantling and Clearing away and carefully stacking materials for reuse for brick or stone masonry in cement mortar walls under 3m height etc., complete complying with standard specifications and as directed by the departmental officers |
| 6 | Dismantling and Clearing away and carefully stacking materials for reuse for RCC by manual / by using deploying machineries etc., complete complying with standard specifications and as directed by the departmental officers |
| 7 | Clean removal of Cement plaster from walls etc., complete complying with standard specifications and as directed by the departmental officers |
| 8 | Earth work open excavation by manual means in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the excavated earth with a lead of 10 mts. within the compound in places shown by the departmental officers and clearing and levelling the site, etc., complete complying with standard specification and as direct ed by the departmental officers. |
| 9 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers. -Mixing by manual means |
| 10 | Plain Cement Concrete 1:2:4 (one cement, two crushed stone sand and four hard broken stone jelly) using 20mm jelly for wearing coat including laying, compacting, finishing and curing, etc., complete as per standard specificatins and as directed by the departmental officers.- Mixing by manual means |
| 11 | Plastering with Cement Mortar 1:5 (One cement and Five Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 12 | Weathering course in brick jelly lime concrete using broken brick jelly of size 20mm uniform gauge in pure slaked lime (no crushed stone sand to be used) to the proportion of brick jelly to lime being 32:12.5 by volume and laid over the RCC roof slab in a single layer of required slope and finished by beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime jaggery water, etc., complete as per standard specification and as directed by the deparmental officers. |
| 13 | Finishing the top of roof with one course of machine pressed tiles of size 230 x 230 x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Crushed stone Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers |
| 14 | Supplying and fixing in position best approved of BIS quality PVC rain water down fall pipes having a pressure of 4 kg. / sq.cm including cost of necessry PVC shoe, PVC bend, cast iron gratings of required diameter and special clamps, brass screws, nails, etc., and fixing of cast iron gratings at junction of parapet and the RCC roof slab including finishing neatly etc., complete. The rate shall be inclusive of cast of removable cast iron grating. The PVC pipe shall be fixed in wall with special type of \\"U\\" clamp at the centre of the pipe line in addition to those for more than 3.0 metre pipe length, etc., complete complying with standard specification. 110mm dia |
| 15 | Flooring with ceramic tiles of following size 305 x 305 x 8mm and variety conforming to IS 15622 laid over cement mortar bed of 20 mm thick in cement mortar 1:3 (One Cement and Three crushed stone Sand) with required Cement Slurry and Mortar Plasticizer including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. /sq.m. etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 16 | Dadooing walls with printed design colour glazed tiles of size 300 x 450 x 8mm best approved quality, white / colour glazed tiles conforming to IS 15622 of following sizes in Cement Mortar 1:2 (One Cement and Two crushed stone sand),10 thick with Mortar Plasticizer and pointing the joints with Water Resistant Tile Epoxy Grout at the rate of 0.27 Kg. / sq.m. neatly in all floors, curing, etc., complete complying with standard specification and as directed by the departmental officers.(The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 17 | Paving the floor with best quality Stain Free Nano Polish Vitrified Tiles 600 x 600 x 8mm of size and variety conforming IS 15622 with water absorbtion less than 0.08% of approved colour and shade laid over cement mortar bed of 20mm thick in cement mortar 1:3 (one cement and three crushed stone sand) with required Cement Slurry and Mortar Plasticizer in all floors and the top pointed with Water Resistant Tile Epoxy Grout etc., complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Executive Engineer before use on works) |
| 18 | Brick work in Cement Mortar 1:3 (One Cement and Three Crushed Stone Sand) using best quality Burnt Clay Brick of size 9” x 4 3/8” x 2 3/4” with class designation of 7.5 conforming to IS 1077-1992 for foundation and basement including Cost of Mortar Plasticizer curing, etc.,complete complying with standard specification and as directed by the departmental officers. Brickwork shall be done as per IS 2212-1991 adopting English Bond generally. Other type of bond shall be done as directed by the Executive Engineer in charge. For Foundation and Basement |
| 19 | Plastering with Cement Mortar 1:3 (One cement and Three Plastering sand), 12mm thick in all floors including mortar plasticizer at 200ml per 50Kg of cement used, curing etc. complete complying with standard specification and as directed by the departmental officers. |
| 20 | Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. 50mm thick Slab (using 20mm HBGS Jelly) |
| 21 | Supplying, fabricating and placing in position Mild Steel / Ribbed Tor Steel reinforcement grills of all variety like HYSD/CTD/TMTand all grade like Fe 500, Fe550D, Fe 500 D etc., for all RCC works as per design given including cost of steel reinforcement and G.I. binding wire, wastage etc. complete complying with standard specification and as directed by the departmental officers.(Contractor has to make his own arrangements for the supply of steel reinforcement and binding wire) for Foundation and basement |
| 22 | Supplying and fixing Mild Steel grills for windows, ventilators including priming coat of best approved quality red oxide primer etc., complete complying with standard specification. |
| 23 | Supply and installation of two-track sliding uPVC windows with integrated fly mesh shall utilize uPVC profile sections with an outer wall thickness of 2.30mm (±0.2mm), featuring an outer frame of 92mm x 52mm x 52mm, a shutter of 66mm x 42mm x 50mm, an interlock of 45mm x 36mm, a glazing bead of 24.5mm x 16mm, and a fly mesh shutter of 66mm x 30mm.All profiles of frames, sash, and mullion shall be reinforced, where required, with 1mm thick GI steel sections. Each window will be equipped with various security devices, such as touch locks or crescent locks, along with nylon rollers and an aluminium track for smooth operation, all supplied as per requirements, compliant with relevant specifications, and as directed by departmental personnel.The windows shall incorporate 5mm thick Plain or Pinhead glass, held securely by TPE (Grey) weather-sealed gaskets. All corners and mullion joints of the frame and sash are to be mitred cut and fusion welded without any mechanical joints, with all welded joints neatly trimmed and finished with a grooved nib to ensure the final products are free from sharp edges.The complete window units shall be fixed into pre finished openings by drilling and fastening through the outer frame using high-quality fasteners, and silicon sealant will be applied to fill the gap between the wall and window frame for a leak-proof installation and complete finish etc., Complete and as directed by the department officers. |
| 24 | Manufacturing supplying and fixing of Fully Panelled steel door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames, stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat sandwitching the C.R. sheet in between additional stiffeners with 18x5mm M.S. flat is provided diagonally at the rear side of the shutter. 3nos. of Steel Parliament Hinges of Size 125mm x 150mm in case of single leaf and 6nos. of Steel Parliament Hinges of Size 125mm x 150mm in double leaves shutter to be provided. 6nos. of holdfasts 200 mm in length made of angle section spliced at the ends are welded to the outer frames of the door. Tower bolts 3 nos, one at the top, one at lock rail(Inner) and the other at the bottom are provided 1no. Aldrop is provided at lock rail section in the door 2 Nos of 200mm handle are to be provided. One rotaing locking arrangements for the inner side of the door and additional provision for locking arrangements for lock is provided on the rear side of the door at an appropriate place. Incase of double leaf door M.S.Flat 32 x 3mm at 1.1Kg/m is provided on the one shutter t conceal the gap between the two shutters.at an appropriate place in the door. A tie bar is provided at the bottom of the frame to prevent twisting of frame during transportation and fixing. All members are given a coat of red oxide primer as directed by the departmental officers. The rate includes cost of all materials, labour charges, transportation to site of work, loading, un loading and all other incidental charges etc., complete complying with standard specification and as directed by the departmental officers. - Single leaf |
| 25 | Fabricating, Supplying and fixing in position Mosquito net arrangements of Openable type. The Outer frame shall be made with Powder coated Aluminium Natural colour matt finish Aluminium Hollow section of size 31mmx40mmx1.55mm. The Vertical center Mullion made with Aluminium Hollow section of size 55mmx11mmx1.55mm.The Horizontal and Vertical Aluminium Hollow section Shutter frame of size 31mmx13mm with a thickness of 1.55mm. The Mid Horizontal Aluminium Hollow section frame provided in the shutter with a size of 10mmx11mmx1.55mm. The Epoxy coated Stainless Steel 304 grade wire mesh with dia of 0.19mm shall be provided for Net. The U shaped Aluminium handle provided in the each shutter with a size of 19mmx26mm.The Connection Mechanism between Shutter and Outer frame that enables opening the Mosquito net. The Mosquito net arrangement should be fixed to the window with 100% packing with Screws, Silicon packing all around the frames with including cost of all materials, labours, power consumption required for fabrication, drilling holes in RCC column/wall, masonry walls, Window frames, wherever necessary with drills to the required extent and make good to the original conditions after fixing and also as directed.All the Aluminium sections are to the powder coated with matt finish under electrically controlled conditions in accordance with relevant IS Code etc.complete complying with standard specification and as directed by the departmental officers. |
| 26 | Manufacturing, supplying and fixing of cupboard shutter using country wooden (kongu) frame of 100 m x 32 mm thick for outer frame horizontal and vertical members. The shutter frame of size 75 x 32 mm of country wooden scantling (Horizontal 3 nos., Vertical 2 nos., of each shutter) with 12 mm thick both side prelaminated particle board (exterior grade) shutter. The shutter are fixed to the frame with requied 6 nos., of SS hinges of 100 x 30 mm 2 nos., ‘D’ type alumium hadle 100 mm 2 nos., of aluminum tower bolts 75 x 10 mm 2 nos., of cupboard lock etc., the country wooden frame shall be painted two coats with synthetic enamel paint over one coat of wooden primer. The prelaminated particle board and furniture fittings used should be got approved by the Executive Engineer before use on works. The cost is inclusive of aluminum handle, tower bolts, SS hinges, screws, nails, and required further fittings and painting the frame and inner side of prelaminate shutter etc., complete complying with standard specification and as directed by the departmental officers. |
| 27 | Distempering the old wall and ceiling two coats with best oil bound distember of approved quality including preparation of surface, the rate includes cost of brushes, high scaffolding arrangements, neat finishes, etc., complete complying with standard specification and as directed by the departmental officers. |
| 28 | Painting old Plastered Wall Surface with two finishing coats of ready mixed Exterior Emulsion of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 29 | Painting Old iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with Two coats of best approved first quality and colour of synthetic enamel paint in all floors etc., complete complying with standard specification and as directed by the departmental officers.(The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 30 | Painting Old wood work with Two coat of synthetic enamel ready mixed paint of approved quality and colour in all floors etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 31 | Painting new iron works such as steel doors, windows, ventilators, window bars, balustrades etc., with two coats of best approved first quality and colour of synthetic enamel paint over the existing red oxide priming coat in all floors excluding cost of priming coat etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 32 | Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting, and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3(2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. - External water supply - above ground level. 25mm dia UPVC Pipe |
| 33 | Supplying, laying and jointing UPVC pipes of Class 5 (having working pressure of 10 kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety of the following dia including cutting, and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3(2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges, etc., complete complying with standard specifications. The UPVC pipes shall be got approved by Executive Engineer before use on works. - Internal water supply - above ground level. 25mm dia UPVC Pipe |
| 34 | Supplying and fixing in position first quality and approved variety of Gun metal Gate Valve / Wheel Valve with BIS make of the following dia including cost of shellac, thread balls, etc., complete complying with standard specifications (for both internal and external water supply arrangements). The valves to be used on work shall be got approved by the Executive Engineer before use on work. 25mm dia Gun Metal Gate Valve |
| 35 | Supplying UPVC Specials (with working pressure 10 kg / sq.cm) in water supply arrangements (both in internal and external water supply arrangements) etc., complete complying with standard specification. (The UPVC specials should be got approved by the Executive Engineer concerned before use on works.) |
| 36 | 25mm dia UPVC Elbow |
| 37 | 25mm dia UPVC Tee |
| 38 | 25mm dia UPVC Union |
| 39 | 25mm dia UPVC Bend |
| 40 | Supplying and fixing in positon Indian Water Closet (Oriya type) of size 580 x 440mm white glazed earthern ware of approved quality and brand with \\"P\\" or \\"S\\" trap conforming to BIS with crushed stone sandcushion and forming flooring alround the closet using 40mm broken brick jelly in lime concrete 1:2:5 (One lime, Two crushed stone sandand Five brick jelly) 100mm thick and finishing the top to the required slope and including giving necessary connection to PVC pipes (including the cost of 110mm dia PVC pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof / floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officers. (The water closet should be got approved by the Executive Engineer before use on works). |
| 41 | Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level |
| 42 | 110mm dia PVC Soil / Waste Pipe |
| 43 | Supplying and fixing in position best quality and approved make Indian made white glazed earthernware wash hand basin of size 550 x 400mm (without pedestal) with a pair of cast iron brackets, including cost 15mm dia brass CP pillar tap, 32mm dia \\"B\\" class GI waste pipe with rubber plug and chain, 15mm dia GM wheel valve, 15mm brass nipple, 15mm dia nylone connection, 32mm dia CP brass waste coupling including fixing of wash basin using CI brackets on to the wall in position with TW plugs and screws, rubber washers, white lead and giving necessary water supply connection and painting the brackets with two coat of painting over a priming coat of anti-corrosive paint including testing for leakages etc., complete complying with standard specification and as directed by the departmental officers. (The wash hand basin and specials should be got approved by the Executive Engineer before use on works). |
| 44 | Supplying and fixing in position 15mm dia brass CP screw down tap (heavy duty) of approved make conforming to BIS specifications and quality including cost of shellac, thread, etc., complete complying with standard specification and including cutting and threading wherever necessary. (Taps should be got approved by the Executive Engineer before use on the works) |
| 45 | Supplying, fixing of cylindrical vertical notational polyethene water storage tank of 1000 litres capacity confirming to IS 12701 / 96. The tank is meant of outer (or) indoor, use complete with removable hnged top locking arrangements and to make provision to fix with simply pipelines necessary man hole with cover and including all PVC specials, plugs, screws, nails to fix the tank etc., and the tank should be fixed firmly as directed. The rate shall inclusive of all materials labour, conveyance, hoistings and fixing charges etc., (The water tank should be got approved by the Executive Engineer before use on works by the departmental officers) |
| 46 | Supplying and fixing in position of 1.00 HP monoblock pumpset of approved quality and make as per ISI specification of size 45 x 50mm including fixing on suitable pedstel with one number of bed bolt cement concrete the pumpset confirm to ISI starter three phase of 1440 RPM with suitable foot valve etc., including wiring from panel board to mortar and fixing including delta starter, main switch capacitor with board etc, complete The motor and pump should be got approved by the Executive Engineer. |
| 47 | Supplying and fixing Solid PVC Door Shutters using 19 Gauge 19mm MS square tubes for styles and outer frames. 15mm MS square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC Sheets. Shutter using 5mm thick solid PVC Sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, lock rail and bottom rail shall be 75mm x 30mm. The over all size of frames shall be 50mm x 45mm with suitable rabate for housing the shutter.Solid panel PVC door with frame |
| 48 | Providing soak-pit with 900 mm dia RCC well ring 300 mm height 3 nos. and covered with RCC cover slab including necessary excavation for placing well rings and connecting to inspection chamber for the collection of sewage from toilet etc., complete complying with standard specifications |
| 49 | Supplying and fixing Medium Density Fibre board (SBG I) of exterior grade of following type with thickness conforming to IS 12406 / 2003 with necessary adhesive and C.P. screws, including fixing of aldrops, tower bolts, hinges and lock strike plates, putty, fevical, varnish for T.W. lipping with thinner colouring agent etc., The rate includes cost of materials and cost for furniture fittings such as 3 nos SS 304 Grade Parliament Hinges of required Size (125mm x 150mm), 1 no Alu. aldrop 250 x 16mm, 2no Alu. tower bolt of 300x12mm and 1 no Alu. tower bolt of 200x12mm, 2 Nos Alu. Handles, 1 no door stopper with rubber bush incase of Single leaf door, cost of labour charges for fixing in position etc., complete. All Aluminium furniture fittings are to be anodised with matt finish under electrically controlled condition in accordance with ISI specification 1868/1968 for anodic film thickness of not less than 15 microns, The rate is inclusive cost of fevical and fixing charges, transportation, loading, unloading and all other incidential charges, handling charges etc., complete complying with standard specification and as directed by the departmental officers - Single leaf. Type : Both side Pre laminated including external lipping with Kiln dried soft wood of 35mm thick thickness: |
| 50 | Painting new wood work with two finishing coats of synthetic enamel ready mixed paint of approved quality and colour over one coat priming coat in all floors including the cost of primer etc., complete complying with standard specification and as directed by the departmental officers. (The make, quality and colour of paint should be got approved by the Executive Engineer before use on works.) |
| 51 | Supplying and fixing position PVC Nahani Trap of size 100x75mm with best PVC gratings of approved brand and quality, fixed over a bed of brick jelly lime concrete 1:2:5 (One part of lime, two part of M-Sand and five part of 40mm gauge brick jelly) and finished with Cement Mortar 1:3 (One Cement, Three M-Sand) including dismantling masonry works wherever found necessary and making good the dismantled portions to the original condition and giving connection to the PVC pipes, etc., complete complying with standard specification. (The Nahani Trap should be got approved by the Executive Engineer before use on works) |
| 52 | Supplying fixing and errecting of steel roof trusses and roof truss purlins fixing for PPGL sheet roofing using MS. square tube of size 50x50x4.50 mm raffter, Tie angles and MS square tube of size 50x50x4.50mm for sturts and MS plat of size 12 mm thick for fixing PPGL sheet. The purlins using MS square tube of size 38x38x4.05 mm shall be properly anchored to the supporting super structure and fixed in concrete at wall and spacing of purlins are to be arranged to use the standard size or sheet and spacing should not execeed 1680 mm and free over hang at eves should not be more than 400 mm, the cleats shall be wellded to the trusses firmly and fixed on the down stream side of purlins. The ridge purlins fixed at 77 to 115 mm away the apex of the roof. The trusses shall have welded joints only at all guessets plate junctions except gussets at bottom chords to have bolts and nuts to permit transportation of trusses as directed. The foundation anchor bolts of trusses will be fixed in concrete at wall in bed blocks and well cured, labour for erection of trusses of approved quality transportation, priming coat for all members, cutting, bending, and welding etc., The trusses should be connected at bottom 1 / 3 part by steel tie angles and with top and bottom wind bracings as per design given. The chord of the trusses of bottom channel should suitablely cambered. The truss and purlins should be given priming coat of Rex Oxide primer of approved quality including labour for erection, transportation, wellding etc., complete complying with standard specification. |
| 53 | Supplying , fixing and roofing with colour galvalume sheet of 0.47mm thick with all necessary accessories such as J/V bolt and nuts of suitable length with suitable bitumen washers complete complying with standard specification and as directed by the departmental officers. |
| 54 | GST @ 18% Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 31, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender