Supply Of 1) EXPANDABLE CORPECTOMY DEVICE - SYSTEM, 2) BONE FILLER DEVICE, 3) FENESTRATED ADAPTER, 4) NEURO SPINE ANTIMICROBIAL PROTECETION DRAPE SET & 5) DISTRACTABLE ANTERIOR SPACER DL 14DIA 16-25MM-L
Tender Overview
Project Description
Supply Of 1) expandable corpectomy device - system, 2) bone filler device, 3) fenestrated adapter, 4) neuro spine antimicrobial protecetion drape set & 5) distractable anterior spacer dl 14dia 16-25mm-l , srphc82364100-neuro spine antimicrobial protecetion drape set consists of lap rotomy drape-1no,fluidshield mask with visor-4nos,fluidshield face masks without visor-1 no,back table cover reinforced-2nos. unit:set [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82364090-fenestrated adapter - should be compatible with fenestrated s crews to reduce the risk of cement leakage. should be compatible with bone filler device for cement injection. should create channel for cement filling. should have the approval of drug controller general of india. should have us iso or bis or fda or ce approval [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82364080-distractable anterior spacer dl 14dia 16-25mm-l: should be mad e up of titanium. should be mri compatible. should be supplied with cage, two hole plate an d two screws. suitability as per iso/bis/ce/cdsco approval. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82364085-expandable corpectomy device - system should offer a variety of centerpiece diameters and modular end caps that afford surgeons the flexibility neede d to operate paitents through a lateral, anterior or posterior-lateral approach. system s hould have kyphotic/ lordotic end cap options. system should have a release mechanism t hat allows implant to be adjusted or removed in any surgical approach . system should ha ve centerpieces with diameter from 13mm to 19mm with height ranging from 16 to 124mm. s ystem should also have 1.2mm incremental expansion with self locking feature. system sh ould have a self locking mechanism that eliminates the need for placing a set screw durin g surgery and also allow flexbility of placing the bone graft after implant insertion. sys tem should have color coding for ease of use. system should be regisistered with drug c ontroller general of india. suitability as per iso or bis or fda or ce or cdsco approval. un it:set [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82364087-bone filler device - should be compatible with fenestrated scre ws system. should contain luer lock which will connect with syringe for the delivery of bone cement into the fenestrated screw system. should comprise of outer and inner style t for injecting the cement. inner stylet should contain calibration to measure cement vol ume . bone filler device should have capacity to hold atleast 1.5cc of cement. it should be compatible with kyphon cement mixture.should have approval of drug controller general of india. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
BOQ
| Sl. No. | Item Description |
|---|---|
| 1 | SRPHC82364100-NEURO SPINE ANTIMICROBIAL PROTECETION DRAPE SET CONSISTS OF LAP ROTOMY DRAPE-1NO,FLUIDSHIELD MASK WITH VISOR-4NOS,FLUIDSHIELD FACE MASKS WITHOUT VISOR-1 NO,BACK TABLE COVER REINFORCED-2NOS. UNIT:SET [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 2 | SRPHC82364090-FENESTRATED ADAPTER - SHOULD BE COMPATIBLE WITH FENESTRATED S CREWS TO REDUCE THE RISK OF CEMENT LEAKAGE. SHOULD BE COMPATIBLE WITH BONE FILLER DEVICE FOR CEMENT INJECTION. SHOULD CREATE CHANNEL FOR CEMENT FILLING. SHOULD HAVE THE APPROVAL OF DRUG CONTROLLER GENERAL OF INDIA. SHOULD HAVE US ISO OR BIS OR FDA OR CE APPROVAL [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 3 | SRPHC82364080-DISTRACTABLE ANTERIOR SPACER DL 14DIA 16-25MM-L: SHOULD BE MAD E UP OF TITANIUM. SHOULD BE MRI COMPATIBLE. SHOULD BE SUPPLIED WITH CAGE, TWO HOLE PLATE AN D TWO SCREWS. SUITABILITY AS PER ISO/BIS/CE/CDSCO APPROVAL. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 4 | SRPHC82364085-EXPANDABLE CORPECTOMY DEVICE - SYSTEM SHOULD OFFER A VARIETY OF CENTERPIECE DIAMETERS AND MODULAR END CAPS THAT AFFORD SURGEONS THE FLEXIBILITY NEEDE D TO OPERATE PAITENTS THROUGH A LATERAL, ANTERIOR OR POSTERIOR-LATERAL APPROACH. SYSTEM S HOULD HAVE KYPHOTIC/ LORDOTIC END CAP OPTIONS. SYSTEM SHOULD HAVE A RELEASE MECHANISM T HAT ALLOWS IMPLANT TO BE ADJUSTED OR REMOVED IN ANY SURGICAL APPROACH . SYSTEM SHOULD HA VE CENTERPIECES WITH DIAMETER FROM 13MM TO 19MM WITH HEIGHT RANGING FROM 16 TO 124MM. S YSTEM SHOULD ALSO HAVE 1.2MM INCREMENTAL EXPANSION WITH SELF LOCKING FEATURE. SYSTEM SH OULD HAVE A SELF LOCKING MECHANISM THAT ELIMINATES THE NEED FOR PLACING A SET SCREW DURIN G SURGERY AND ALSO ALLOW FLEXBILITY OF PLACING THE BONE GRAFT AFTER IMPLANT INSERTION. SYS TEM SHOULD HAVE COLOR CODING FOR EASE OF USE. SYSTEM SHOULD BE REGISISTERED WITH DRUG C ONTROLLER GENERAL OF INDIA. SUITABILITY AS PER ISO OR BIS OR FDA OR CE OR CDSCO APPROVAL. UN IT:SET [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 5 | SRPHC82364087-BONE FILLER DEVICE - SHOULD BE COMPATIBLE WITH FENESTRATED SCRE WS SYSTEM. SHOULD CONTAIN LUER LOCK WHICH WILL CONNECT WITH SYRINGE FOR THE DELIVERY OF BONE CEMENT INTO THE FENESTRATED SCREW SYSTEM. SHOULD COMPRISE OF OUTER AND INNER STYLE T FOR INJECTING THE CEMENT. INNER STYLET SHOULD CONTAIN CALIBRATION TO MEASURE CEMENT VOL UME . BONE FILLER DEVICE SHOULD HAVE CAPACITY TO HOLD ATLEAST 1.5CC OF CEMENT. IT SHOULD BE COMPATIBLE WITH KYPHON CEMENT MIXTURE.SHOULD HAVE APPROVAL OF DRUG CONTROLLER GENERAL OF INDIA. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 22 daysTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender