Science and Technology Statutory Bodies & Commissions/Committees Closing in 1 days TDR #56497723

Tender For Construction Of Twin Chamber Acoustic Material Testing And Utility Building Including Electrification For Atf Division, Nwtc, Belur Campus, Csir-Nal, Bengaluru - 5600037

Issued by Statutory Bodies & Commissions/Committees · Bengaluru Urban, Karnataka
Tender Value
1.21 Crore
Estimated cost
Bid Submission
23 Jul 2026
1 days left
EMD
2.43 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Bengaluru Urban → Karnataka
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Twin Chamber Acoustic Material Testing And Utility Building Including Electrification For Atf Division, Nwtc, Belur Campus, Csir-Nal, Bengaluru - 5600037

BOQ

Name of Work:-
Sl. No. Item Description
1EARTH WORK
2Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lif upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil.
4Excavating trenches by mechinical / manual means of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, for all depth, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soilPipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 and for all lif.
6CEMENT CONCRETE (CAST IN SITU)
7Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
8Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth1:3:6 (1 Cement : 3 coarse sand (zone-III) : derived from natural sources: 6 graded stone aggregate 20 mm nominal size derived from natural sources)
9Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth1:4:8 (1 Cement : 4 coarse sand (zone-Ill) derived from natural sources: 8 graded stone aggregate 40 mm nominal size derived from natural sources)
10Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:1:2:4 (1 Cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources)
11REINFORCED CEMENT CONCRETE
12Centering and shuttering including strutting, propping etc. and removal of form for Foundations, footings, bases of columns, etc. for mass concrete
13Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
14Centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform
15Centering and shuttering including strutting, propping etc. and removal of form forLintels, beams, plinth beams, girders, bressumers and cantilevers
16Centering and shuttering including strutting, propping etc. and removal of form forColumns, Pillars, Piers, Abutments, Posts and Struts
17Centering and shuttering including strutting, propping etc. and removal of form forWeather shed, Chajjas, corbels etc., including edges
18Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).Suspended floors, roofs, landings, beams and balconies (Plan area to be measured)
19Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
20Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
21Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum
22Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth levelConcrete of M25 grade with minimum cement content of 330 kg /cum
23CLADDING WORK
24Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels.Granite stone slab of colour black, Cherry/Ruby redArea of slab over 0.50 sqm
25Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work
26Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete.
27Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
28WOOD AND P. V. C. WORK
29Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood
30Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
31Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured).
32Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
33Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).
34Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete.
35Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.Twin rubber stopper
36Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds.Three track three panels sliding window with two glazed & one wire mesh panels with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body.Using R3 series with frame (98 mm & above) x (40 mm & above) & both glazed and fly screen sash (30 mm & above) x (55 mm & above) with zinc alloy (zamak) powder coated handle on every glazed panel along with multi-point locking system. (Height upto 1.8m).
37Providing and fixing factory made uPVC glazed/wire mesh windows/ doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and lnline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for (i) Sites with basic wind speed > 45 m/sec as per IS 875 — Part 3 (ii) Sites with structure height more than 20m for all wind speeds. Fixed window/ ventilator with mullion /transom.Using R3 series with frame (55 mm & above) x (45 mm & above) & mullion (55 mm & above) x (65 mm & above). (Height upto 2.5 metre)
38STEEL WORK
39Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
40FLOORING
41Providing and laying Vitrified tiles in floor in diferent sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.Glazed Vitrified tiles Matt/Antiskid finish of sizeSize of Tile 600 x 600 mm
42Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
43FINISHING
4420 mm cement plaster of mix:1:4(1 cement: 4 fine sand)
4520 mm cement plaster of mix:1:4(1 cement: 4 coarse sand)
466 mm cement plaster of mix:1:3(1 cement :3 fine sand)
47Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete.
48Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm)
49Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer's specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work
50Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work
51French spirit polishing :Two or more coats on new works including a coat of wood filler
52Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.Two coats
53Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
54Dismantling and Demolishing
55Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.Nominal concrete 1:3:6 or richer mix (including equivalent design mix)
56Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
57Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.In cement mortar
58Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge :In cement mortar
59Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :Of area 3 sq. metres and below
60Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead.
61Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of:G.S. Sheet
62Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
63ROAD WORK
64Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-in-charge. (The panel shuttering work shall be paid for separately). (Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately).
65SANITARY INSTALLATIONS
66Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board510x1040 mm bowl depth 250 mm
67Providing and fixing CP Brass 32 mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.
68Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe32 mm dia
69WATER SUPPLY
70Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.20 mm nominal dia Pipes
71Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings and fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia Pipes
72Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :25 mm nominal bore
73Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length15 mm nominal bore
74Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
75Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms.15 mm nominal bore
76Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:893115 mm nominal bore
77Providing and fixing PTMT grating of approved quality and colour.Circular typeCircular type100 mm nominal dia
78DRAINAGE
79Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design:180x150 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 5
80Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete :For pipes 100 to 250 mm diameter
81Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 455x610 mm and 45 cm deep for single pipe line :With common burnt clay F.P.S. (non modular) bricks of class designation 5
82Extra for depth beyond 45 cm of brick masonry chamber :For 455x610 mm sizeWith common burnt clay F.P.S. (non modular) bricks of class designation 5
83ALUMINIUM WORK
84Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
85Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete.Upto 5 mm depth and 5 mm width
86WATER PROOFING
87Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
88Providing and applying fibre reinforced elastomeric liquid water proofing membrane with resilient acrylic polymers having Sun Reflectivity Index (SRI) of 105 on top of concrete roof in three coats @10.76 litre/ 10 sqm. One coat of self-priming of elastomeric waterproofing liquid (dilution with water in the ratio of 3:1) and two coats of undiluted elastomeric waterproofing liquid (dry film thickness of complete application/system not less than 500 microns). The operation shall be carried out after scrapping and properly cleaning the surface to remove loose particles with wire brushes, complete in all respect as per the direction of Engineer- in-Charge.
89MARKET RATE ITEMS
90Provinding Precast Cement concrete solid block masonry including hoisting and setting in position with cement mortar 1:6 (Cement :6 Coarse sand) Completed as per the direction of Engineer in charge as per site condition
91Providing & laying in position cement concrete 1:5:10 ( 1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) of 100mm thick and with cemenet concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stone aggregate 20mm nominal size) of 50mm thick and top finished with 12mm thick cement mortar 1:4 ( 1 cement: 4 fine sand ) including a floating coat of neat cement for plinth protection concrete.
92Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.160 mm diameter
93Providing and fixing on wall face unplasticised Rigid PVC moulded fittings/accessories for conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. Elbow 160 mm diameter
94Providing and fixing on wall face unplasticised Rigid PVC moulded fittings/accessories for conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. shoe 160 mm diameter
95Providing and fixing on wall GI Clamps with bracket for the 160mm dia rainwater Pipes including anchor bolts etc,complete as per direction of engineering in charge.
96Providing and fixing fly proof stainless steel grade 304 wire gauge, to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm all complete.
97Providing and fixing Stainless steel handles 1.20m long and outer dia 25mm with SS screws etc. complete as per direction of Engineer-in-charge
98Extra for providing labrota Granite finish over the Polished granite As per the direction of Engineer in charge.
99Providing and fixing under counter top wash basin with 65mm extension body waste coupling ,pressmatic pillar cock and wash basin (parryware make) including making good the walls wherever required. White vitreous china wash basin size 430X550X190
100Providing and Fixing PVC Multi trap (floor trap) of approved quality and make and confirming to ISI specifications including construction CC1:2:4 as directed by Engineer-in-charge.
101Providing and fixing CPVC Control valve 25 mm nominal bore as per the direction of Engineer in charge
102Providing and fixing CPVC Union 25mm nominal bore as per the direction of Engineer in charge
103Providing and fixing PVC/SWR pipes for sewer lines - Type :B of ISI :13592 approved by CPWD specifications of approved make and quality with all necessary specials such as collars, elbows, bends, tees, doors Y's etc., using jointing ring with solutions for necessary scaffolding etc., complete with all lead and lift and as directed by the enginner in charge. 110mm dia
104Providing and fixing PVC/SWR pipes for sewer lines - Type :B of ISI :13592 approved by CPWD specifications of approved make and quality with all necessary specials such as collars, elbows, bends, tees, doors Y's etc., using jointing ring with solutions for necessary scaffolding etc., complete with all lead and lift and as directed by the enginner in charge. 75mm dia
105ELECTRICAL ITEMS
106Laying and fixing of one no PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of Upto 35 sq.mm (clamped with 1mm thick saddle) size on wall surface as required.
107Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq.mm size in the existing RCC/HUME pipe as required.
108Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm size in the existing masonry open duct as required.
109Supplying and laying of size 63 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
110Supplying and laying of size 120 mm dia DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.
111Supplying and making end termination with brass compression gland and aluminium lugs for size 4 X 16 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
112Supplying and making end termination with brass compression gland and aluminium lugs for size 4 X 50 sq. mm of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
113Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
114Supplying and laying 25mm X 5mm GI strip at 0.5 m below ground as strip earth electrode including connection / terminating with nut, bolt, spring washer etc. (jointing shall be done by overlapping and with two sets of brass bolts, nuts, spring washers spaced at 50 mm).
115Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
116Supplying and fixing 6 way , Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, marking of circuits, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
117Supplying and fixing of 4 way (4 + 12), Double door surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, provision for mccb incomer, common neutral link, earth bar, blanking plates, din bar for mounting MCBs, marking of circuits (but without MCBs and incomer) as required .
118Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A \\"C\\" curve, SPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required
119Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A \\"C\\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
120Supplying and fixing 25A rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required
121Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
122Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Triple pole in the existing MCB DB complete with connections, testing and commissioning etc. as required.
123Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required.
124Supplying and fixing of the following sizes of medium-class PVC conduit, along with necessary accessories, installed on surface/metal truss with heavy-duty bar saddles, including cutting the wall (where required) and making good the same, complete as required.20mm
125Supplying and fixing of the 25mm sizes of medium-class PVC conduit, along with necessary accessories, installed on surface/metal truss with heavy-duty bar saddles, including cutting the wall (where required) and making good the same, complete as required.
126Supplying and drawing 3 x 1.5 sq. mm sizes FRLS PVC insulated Copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
127Supplying and drawing 3 x 2.5 sq. mm sizes FRLS PVC insulated Copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
128Supplying and drawing 3 x 4.0 sq. mm sizes FRLS PVC insulated Copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
129Supplying and fixing 2 Module (75mmX75mm) size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
130Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.3 Module (100mmX75mm)
131Supplying and fixing 6 Module (200mmX125mm) size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required.
132Supplying and fixing 5/6 A modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate as required. .
133Supplying and fixing 15/16 A SP modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate as required. .
134Supplying and fixing 3 pin 5/6 A modular socket on the existing modular plate & switch box including connections but excluding modular plate as required.
135Supplying and fixing 6 pin 15/16A modular socket on the existing modular plate & switch box including connections but excluding modular plate as required.
136Supplying and fixing Telephone/network(RJ45 IO) modular socket on the existing modular plate & switch box including connections but excluding modular plate as required.
137Supplying and fixing modular 2M Stepped Fan regulator on the existing modular plate & switch box including connections but excluding modular plate as required.
138Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
139Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, ceiling rose, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(group c)
140Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. (Group-C)
141Installation, Testing, Commissioning of ceiling/surface fittings(LED) of all sizes and shapes , complete with all accessories including connections with 3C*1.5 sq.mm copper Flexible cable as etc. as required.
142Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 210 CM/min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, speed control compatible for modular electronic type fan regulator and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. including fixing fan hook in ceiling Complete as required.
143Supplying, Installation, Testing & Commissioning of LED Down light of 12 watt -15 watt, System lumen efficacy ≥120 lm/Watt square Type Powder coated die cast /Extruded aluminium Body including trim material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,frequency 50/60 hz, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% ,P. F.≥0.95, IP20, CRI >80 , CCT 5700°K , Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor cable and earthing etc. as required. System lumen efficacy ≥120 <135 lm/Watt output . Shape size and CCT shall be as approved by Engineer-in Charge as per requirement.
144Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
145Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray \\"bends\\" (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with two numbers GI Suspenders i/c base of suitable size GI angle, GI bolts & nuts, fastner etc as required.
146Installation of exhaust fan up to 450 mm sweep in the existing opening, including making good the damage, connection, testing, commissioning etc.as required.
147Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes.
148Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of LED street light fitting on pole including bending the pipe to the required shape, 2 no's 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required.
149Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
150Erection of metallic pole of Above 4.5 Meter and up to 6.5 Meter length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required.
151Supplying, drawing, Installation, Testing and commissioning of 2 Run of cable CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/PVC trunking, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force: 11.5Kg etc. complete as required.
152Supplying, Installation, Testing and commissioning of Copper Patch Cords of length 1m (3ft) CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
153Supplying, Installation, Testing and commissioning of Copper Patch Cords of length 3m (10ft) CAT6A Patch Cord should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
154Supplying Installation Testing and Commissioning of 24 port Cat6 Patch Panel loaded. Must be of 1U height with clear label holders and white label with the panel.24 Ports Cat-6 Patch Panel should have ETL/UL verification program certificate for compliance with ANSI/TIA-568.2-D etc. complete as required.
155Supplying and fixing of 15U rack size Wall Mount Rack having Fixed Structure with 0.8mm CRCA Sheet, completely knocked-down condition (CKD) Shape, Vertical Mounting Rail 1.6 mm with 'U'Marking, Minimum 2 cable entry/exit provision at Top and bottom with rubber protection, Front 5mm Toughened Glass with lock, wall mounting kit, Powder coated Color- RAL- 7035, complied with UL & RoHS, 2 x 6 sockets 16A power distribution units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1 number, etc. complete as required.
156Supply, install, testing & commissioning of 3 KVA online UPS with with single phase to single phase operating with input MCB,L+N+E, 230V,50HZ,power factor 0.9 lag.output Parameters: Power:3000VA/2400W,Voltage -230V(±1%),Double Conversion Type, Pure sine wave, Frequency Regulation - 50HZ(±1%),Transfer Time-Mains to Battery is Zero Millisec, Transfer Time – Inverter to Bypass -Synchronisation Mode is 4msec, Voltage THD <=2% for Linear Load, <=4% for Non Linear Load, Output Efficiency >90.00% at Full Load, Overload capacity 110% for 10minute (Load test & Back up test to be conducted at site), 120% for 15Sec ,Crest Factor 3:1 Output Power Factor >=0.8 lagBattery:Battery Type SMF Battery ,Voltage 12VTotal VAH Minimum of 1872 VAH and required DC bus bar voltage. DC Link Used to interconnecting of Batteries, Rack for Batteries and UPS. Communication & Management:Interface Ports DB-9, RS232,smart slot, usb.Control Panel Multifunction LCD status and Control Console having Automatic Bypass and Forced Air cooling . Indications: LCD Display Input Voltage/Output voltage/load level/Battery Level/Battery Mode/AC Mode/Bypass/Fault, Alarm Audible and Visible Alarms for Battery mode, Battery low, Overload and fault occurrence.Mains Input Under voltage and Overvoltage Cut-off.
157Supply of 36W to 40W, 240V, suspended type 1 feet * 4 feet length minimum colour temperature 5700 deg kelvin with luminous efficiency of 120 lumen/watt, internal surge protection of 2.5 KV with Short & Open circuit protection, P.F.≥0.95, IP20, CRI >80, complete set with suitable driver in powder coated CRCA housing, protected from dust and insects as required.
158Supply of 50W, AC 240V,frequency 50hz,IP65,IK08, flood light LED fitting with colour temperature 5700 deg kelvin with luminous efficiency of 120 lumen/watt , internal surge protection of 2.5 KV with Short & Open circuit protection, P.F.≥0.95, CRI >80, complete set with suitable driver in die-cast aluminium powder coated housing, protected from dust and insects as required
159Supply of 7W to 12W,240 V, Mirror light, colour temperature of 5700 deg kelvin, internal surge protection of 2.5 KV with Short & Open circuit protection surface mounted LED fitting complete set with suitable driver with inbuilt protection in polycarbonate housing, protected from dust and insects as required.
160Supply of 45W , AC 240V,frequency 50hz,IP65, Building light LED fitting with colour temperature 5700 deg kelvin with luminous efficiency of 120 lumen/watt , internal surge protection, CRI >80, complete set with suitable driver in die-cast aluminium powder coated housing, protected from dust and insects as required.
161Supply and fixing of 400 mm sweep metal body wall mounted fan with speed regulator, 1400 RPM suitable for operation on 230 V,50hz single phase supply.
162Supply of exhaust fan 300 mm sweep size metal body with bracket blades complete ,minimum Air Delivery 600 CFM,900 RPM suitable to operation on 230 V,50hz single phase supply.
163Supply of 4C X16 sq. mm Aluminium armoured Cable Aluminium conductor 1.1kV grade XLPE insulated, PVC sheathed, armoured/ unarmoured UG cable in one length as per IS : 7098 (Pt-1) 19888.
164Supply of 4C X6 sq. mm Aluminium armoured Cable Aluminium conductor 1.1kV grade XLPE insulated, PVC sheathed, armoured/ unarmoured UG cable in one length as per IS : 7098 (Pt-1) 19888.
165Supply of 1C X 10 sq. mm Copper Unarmoured multistand Flexible Wire(Green colour) 1.1kV grade XLPE insulated, PVC sheathed, armoured/ unarmoured UG cable in one length as per IS : 7098 (Pt-1) 19888.
166Supplying and making end termination with brass compression gland and aluminium lugs for 4C*6 Sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
167Supplying and fixing of following rating, 240V, 10 kA, SP 5-32A rating, \\"D\\" Curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
168Supplying and fixing of SPN 5-32A rating, \\"D\\" Curve rating, 240V, 10 kA, following curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
169Removing and dismantling of existing electrical installations consisting of (a) tube-light fittings 20 Nos,(b) old wiring/cables on surface for a total length of 100 meters (c) socket outlets, 15 Nos (d) MCB DBs, 2 Nos, and shifting of all dismantled materials to the stores as directed by site engineer.
170Supplying and fixing of FRP Box 200mmX140mmX95mm size (nominal size) on surface with hinged door with suitable grounding copper bar link with holes / bakelite 4 way connector fitted inside the box etc. as required.
171Supply and installation of Timer for light control Manual Switching ON / Automatic / OFF Daily Switching dial with capitive segments, Clock Precision +/- 5 Min for the daily time switch -10deg to +55degC Operating temparature and with Suitable SP 6 amp MCB,selector switch and 8 Way Bakelite connector and all required accessories and wiring complete, fixed in the FRP box of dimension (200x140x95 mm) as required.
172Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for 4C x 6 sq.mm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
173Supply and drawing of Cat 6 UTP armoured Cable Consists of PE Insulated 23AWG Solid Bare Annealed Copper Conductors, twisted 4pair stranded over Cross PE Separator filler, Inner sheath, GI wire Armour and Outer black Polyethylene Sheath in the existing PVC trunk/HDPE pipe as required
174Supplying and fixing of 105X50 mm Snap on Trunking sizes of DLP PVC snap on/mini trunking along with finishing accessories on surface as required.
175Supply and Erecting of 600 mm length X 600 mm width X 600 mm depth RCC chamber with covers as required.
176Supply,installation,testing and commissioning of maintenance free earthing with GI dual pipe of 2000mm long (min)75mm dia as outer pipe with (min) 45mm dia of inner pipe of 80-100 microns galvanized, filled with highly conducting metallic compounds with the permanent sealing at both the ends and lead terminal of 50 X 8 mm size at the top the length of the electrode shall be 2000 mm excluding the lead terminal and the length of the lead terminal at the top shall be 100 mm. To ensure the moisture content and electrical conductivity, resistance lowering grounding minerals shall be filled around the electrode (min 25kgs). Heavy duty weather proof plastic earth pit chamber with cover of dimension 250mm dia (top), 330mm dia(bottom) and 260mm (height) shall be used, Numbering of pit and measured value shall be written with weather proof painting or snickering.
177Supply,installation,testing and commissioning of maintenance free earthing with copper single pipe of 2000mm long (min)45mm dia pipe with thickness of 1.6 to 1.8mm, filled with highly conducting metallic compounds with the permanent sealing at both the ends and lead terminal of 50 X 8 mm size at the top, the length of the electrode shall be 2000 mm excluding the lead terminal and the length of the lead terminal at the top shall be 100 mm. To ensure the moisture content and electrical conductivity, resistance lowering grounding minerals shall be filled around the electrode (min 25kgs). Heavy duty weather proof plastic earth pit chamber with cover and locking facility of dimension 254mm dia (top), 330mm dia(bottom) and 260mm (height) shall be used, Numbering of pit and measured value shall be written with weather proof painting or snickering. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56497723
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 1.21 Crore
LAST DATE 23-07-2026
Authority
Authority Name Council Of Scientific And Industrial Research
Work Description Tender for Construction Of Twin Chamber Acoustic Material Testing And Utility Building Including Electrification For Atf Division, Nwtc, Belur Campus, Csir-Nal, Bengaluru - 5600037
Basic Detail
Tender No NAL/07/EBU-B/2026-27
Bidding Type Tender
Location
City Bengaluru Urban
State Karnataka
Key Dates
Publish Date 16 Jul 2026
Submission Date 23 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 1.21 Crore
Tender Fee 1000
EMD 2.43 Lakhs
Exemption Not Available
Document List
1cb2cadc-e004-4fb9-9448-94ad769243e5.html
20260716152449.pdf
20260716152739.pdf
20260716153018.pdf
AcceptenceLetters.pdf
BOQ_331971.xls
D1.pdf
D2.pdf
D3.pdf
D4.pdf
D5.pdf
Tenderdocument.pdf
Tendernotice_1.pdf
UL.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 23, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 1 day
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 2 days

Tender Documents

Download All (ZIP) ↓
html

1cb2cadc-e004-4fb9-9448-94ad769243e5.html

pdf

20260716152449.pdf

pdf

20260716152739.pdf

pdf

20260716153018.pdf

pdf

AcceptenceLetters.pdf

xls

BOQ_331971.xls

pdf

D1.pdf

pdf

D2.pdf

pdf

D3.pdf

pdf

D4.pdf

pdf

D5.pdf

pdf

Tenderdocument.pdf

pdf

Tendernotice_1.pdf

pdf

UL.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders