Defence Statutory Bodies & Commissions/Committees Closing in 19 days TDR #56497199

Tender For Repair And Maintenance Of Different Type Of Water Coolers, Desert Cooler, Air Conditioners, Refrigerators, Deep Freezers Including Misc Works Under Age E/M-Ii Of Ge (N) Mamun.

Issued by Statutory Bodies & Commissions/Committees · Pathankot, Punjab
Tender Value
30 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
19 days left
EMD
60000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Pathankot → Punjab
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Repair And Maintenance Of Different Type Of Water Coolers, Desert Cooler, Air Conditioners, Refrigerators, Deep Freezers Including Misc Works Under Age E/M-Ii Of Ge (N) Mamun.

BOQ

Name of Work:- REPAIR AND MAINTENANCE OF DIFFERENT TYPE OF WATER COOLERS, DESERT COOLER, AIR CONDITIONERs, REFRIGERATORS, DEEP FREEZERS INCLUDING MISC WORKS UNDER AGE E/M-II OF GE (N) MAMUN.
Sl. No. Item Description
1Taking down compressor unit carefuly from the water cooler of Cap 40/80 Ltr, any make and any cap, exchange it with latest new compressor of the same company, fixing sealed unit and charging of refrigerant gas (environment friendly) including testing the complete unit for required performance and smooth functioning for 24Hrs, complete all as specified and directed. Make : Emerson Copeland/ Voltas/ Sidwal/ Usha/Blue star Note: All Engineering works shall be carried out at MES E/M store yard.
2All as per Ser item No 1 here-in-before but of 60/120 Ltrs capacity.Make : Emerson Copeland/Voltas/Sidwal/Usha/Blue star
3All as per Ser item No 1 here-in-before but of 150/150 Ltrs capacity.Make : Emerson Copeland/Voltas/Sidwal/Usha/Blue star
4Replacement of Starting capacitor 80/100 Mfd for water cooler, complete all as specified and directed.
5Replacement of running capacitor 10/15 Mfd for water cooler, complete all as specified and directed. Make: Tibcon/EPCOS/Texla/Havells.
6Replacement of 15mm dia chromium plated push cock, inner & outer thread as per sample, complete all as specified and directed.
7Replacement of blower fan blade for water cooler suitable for 1/10HP & 1/35HP fan motor (as per sample) including nuts/bolts, complete all as specified and directed.
8Replacement of starting relay suitable for water coolers of any make and capacity, complete all as specified and directed . Make: Kirloskar/Sri Ram/Hi Tech/Technomech.
9Replacement of unserviceable blower motor 1/10HP for water cooler 60/120 & 150/150 ltrs capacity including nuts/bolts single phase, 230volt AC, complete all as specified and directed . Make: Universel/AUE/Airmaster
10Replacement of unserviceable blower motor 1/35HP for water cooler 40/80 Ltrs including nuts/bolts single phase, 230volt AC, complete all as specified and directed . Make:Universel/AUE/Airmaster
11Replacement of thermostat switch for water cooler, any capacity, complete all as specified and directed . Make: Renutral/Indofoss/Annapurna.
12Replacement of condensing coil (as per sample) suitable for Water Cooler of capacity 40/80, 60/120, 150/150 Ltrs including welding/soldering at site, complete all as specified and directed.
13Replacement of OLP of water cooler any cap, as per sample, complete all as specified and directed .
14Replacement of PVC connection pipe for water cooler any cap as per sample, complete all as specified and directed .
15Replacement of old unsv/burnt copper bound fan motor with frame, legs, nut and bolts including iron blade for desert cooler 1350RPM, 1/7HP single phase 220 volt 50 c/s, 375-450mm, fixing nut bolts of desert cooler and making necessary electrical connection and testing, complete all as specified.Make: Khaitan/Aristo/AirMaster/Cool home/BSI
16Rewinding of desert cooler fan motor of 1/7HP /1/8 HP single phase 3 speed with super ennamelled copper wire of appropriate gauge, insulating material complete after removing old burnt wire including servicing, change the unserviceable bush, shaft and testing after completion, complete all as specified and directed.
17Replacement of old unsv water lifting submersible pump for desert cooler single phase 220-240volts, 50Hz including connection lead, complete all as specifed and directed. Make: Khaitan/Aristo/AirMaster/Cool home
18Replacement of 3 way PVC water distributor for desert cooler (as per sample) including nuts and bolts suitable size & PVC elbow, complete all as specified and directed.
19Replacement of capacitor 4mfd for desert cooler (as per sample) and making all necessary electrical connection, complete all as specified and directed.
20Replacement of front grill complete with flexible louvers for circulating of air made out of 22gauge GI sheet for desert cooler of any make, size all as per site requirement including making holes, nuts and bolts for fixing, complete all as specified and directed .
21Replacement of three way speed control switch including 5/6 Amp switch rotary type for desert cooler (of make as per sample) and making all the necessary electrical connection, complete all as specified and directed .
22Replacement of side grill, rear, back grill for desert cooler made out 24 gauge GI sheet (ISI Marked) suitable for any make and any size of desert cooler all as per site requirement.
23Replacement of 15mm dia PVC float valve assembly with PVC float valve (as per sample) suitable for water cooler/desert cooler, complete all as specified and directed .
24Replacement of water tank for desert cooler made out 24 gauge GI sheet including suitable size of nuts & bolts for fixing arrangment of desert cooler, complete all as per sample all as specified and directed .
25Replacement of wooden wool pad set of suitable size as required at site for any type of desert cooler, complete all as specified and directed.
26Replacement of side pillar made out of 24 gauge GI sheet including suitable size of nut and bolts for fixing arrangement as per sample, complete all as specified and directed .
27Replacement of 15mm dia PVC pipe for desert Cooler (as per sample) as per site requirement and making necessary connection for free flow of water, complete all as specified and directed .
28Replacement of fan blade for desert cooler, any make and any size as per sample, complete all as specified and directed .
29Replacement of front patti for desert cooler, any make and any size all as per sample, complete all as specified and directed .
30Replacement of desert cooler body top, made of out 24 gauge GI sheet of suitable size including suitable size of nuts & bolts for fixing arrangement as per sample, complete all as specified and directed .
31Replacement of plug top 5/6 Amps, 230V with 1.5m long connection copper lead suitable for 5/6Amps socket for desert cooler, complete all as specified and directed.
32Taking down the aquaguard carefully from the site for servicing /cleaning including replacement filter, ultra violet rod, micro carbon sand, UV membrane , 15mm PVC pipe with nut bolts, washers complete refixing the aquaguard to its original position and testing, complete all as specified and directed.
33Replacement of capacitor 50+ 6Mfd, 6 /8 pin for window / split type AC, complete all as specified and directed.Make: Havells/Asian/Crompton Greaves/Texla.
34Scratching out of old paint by blower lamp, making the smooth surface incl denting of desert coolers. Applying two coats of synthetic enamel paint (spray painting) as per existing colour over one coat of red oxide primer, complete all as specified and directed.
35Taking down compressor unit carefully from window type AC of Cap 1.5 Ton of any make and exchange it with the new compressor suitable to the fixed in any make/Model of AC and tested by the company fixing of sealed unit and charging of refrigerant gas R-22/R-134a (environment friendly) including testing complete unit for required perfomance and smooth functioning for 24Hrs all as specified and directed. Note:. All Engineering works shall be carried out at MES E/M store yard in presence of Engr-in-Charge. Make : Emerson Copeland /Haier/ Whirlpool/ Voltas/ BlueStar/ LG.
36All as per Ser item No 35 here-in-before but for window type AC 2 Ton.Make : Emerson Copeland/ Haier/ Whirlpool/ Voltas/ BlueStar/LG.
37All as per Ser item No 35 here-in-before but of Split AC 1.5 Ton. Make : Emerson Copeland/ Haier/ Whirlpool/ Voltas/ BlueStar/ LG
38All as per Ser item No 35 here-in-before but of Split AC 2.0 Ton. Make : Emerson Copeland/Haier / Whirlpool /Voltas/ BlueStar/LG
39Replacement of electric blower motor double shaft having capacity 1/5HP/1/7HP for 1.5/2.0 Ton window type AC, complete all as specified and directed.Make : Airmaster /AUE/Universal
40Replacement of condensor coil suitable for window type AC 1.5/2.0 Ton (as per sample) including welding/soldering at site, complete all as spd and directed.
41Replacement of cooling coil suitable for window type AC 1.5/2.0 Ton (as per sample) including welding/soldering at site, complete all as specified and directed.
42Replacement of PCB circuit with remote suitable for window type AC 1.5/2.0 Ton (as per sample) including all electrical connections at site, complete all as specified and directed.
43Replacement of PCB circuit, display with remote suitable for Split type AC 1.5/2.0 Ton (as per sample) including all electrical connections at site, complete all as specified and directed.
44Replacement of indoor unit for split AC 1.5 Ton complete including PCB blower motor, swing motor and making all connections, complete all as specified and directed. Make: LG/Hitachi/Mitsubishi/Voltas
45Replacement of indoor unit for split AC 2.0 Ton complete including PCB blower motor, swing motor and making the all connections, complete all as specified and directed. Make: LG/Hitachi/Mitsubishi/Voltas
46Replacement of PVC front Grill suitable for window type AC 1.5/2.0 Ton at site, complete all as specified and directed.
47Replacement of reversible cycle valve including brazing with suitable size of cooper for window & split AC of any capacity, complete all as specified and directed.
48Replacement of AC wire connector including brazing with suitable for split AC and window AC of any capacity, complete all as specified and directed .
49Replacement of electric blower motor, single shaft for out door unit capacity 1/10HP for 1.5 Ton Split type AC, complete all as specified and directed.
50Charging Gas R-22 for AC 1.5/2.0 Ton any type including required brazing to pipe & connecting, complete all as specified and directed. (450gm gas in each Can)
51Replacement of cooling blower for Split AC 2.0/1.5 Ton as per sample, complete all as specified and directed.
52Replacement of condensing fan motor for Split AC as per sample, complete all as specified and directed.
53Replacement of copper pipe ½\\" including cutting, including brazing etc, complete all as specified and directed.
54Replacement of copper Pipe ¼\\" including cutting, including brazing etc, complete all as specified and directed.
55PVC insulated flexible copper conductor 3 core 4 Sqmm 1100volt grade, connected & testing, complete all as specified and directed.
56PVC flexible waste condesing drain out pipe for split AC suitable size, connetced and fixed properly on wall /floor etc, complete all as specified and directed.
57Servicing of AC window /split upto 1.5/2.0 Ton cap by means as cleaning & washing of AC with brushes /chemical etc. and change of filter etc. incl taking down and refixing in position of AC connected & testing, complete all as specified and directed.
58Replacement of outdoor unit for split AC 1.5 Ton complete with compressor, reversiblle cycle valve fan etc. complete including making the all connections and charging the gas, complete all as specified and directed. Make: LG/Hitachi/Mitsubishi/Voltas
59Replacement of outdoor unit for split AC 2.0 Ton complete with compressor, reversiblle cycle valve fan etc. complete including making the all connections and charging the gas, complete all as specified and directed. Make: LG/Hitachi/Mitsubishi/Voltas
60Angle iron frame works in repairs of size 25x25x4mm suitable for supporting of AC's & Desert Coolers, complete with grouting in wall palced on floor incl rollers on floors etc. Make good the disturbed surfacs to match as per existing including all necessary required of cement, sand, bricks etc, complete all as specified and directed.
61Taking down the compressor unit carefuly from the deep freezer upto capacity 350 Ltr capacity of any make and supply and fixed new compressor, fixing of sealed unit and charging of refrigerant gas R-134A (environment friendly) including testing the complete unit for required performance and smooth functioning for 24Hrs, complete all as specified and directed. Note :All machinery works will be carried out at E/M store yard under direction of Engr-in-charge.
62All as per Ser item No 61 here-in-before but capacity exc 350 Ltr but n.exc 500 Ltr.
63Replacement of starting relay suitable for deep freezers cap upto 500 Ltrs (as per sample), complete all as specified and directed.
64Replacement of thermostat switch suitable for deep freezer for cap uptp 500Ltr (as per sample), complete all as specified & directed.
65Replacement of blower motor for deep freezer 4x4 (as per sample), complete all as specified & directed.
66Replacement of voltage stabilizer copper bound 1 KVA to 3KVA, input voltage range 170 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage with accessories etc., complete all as specified & directed. Make- Blue Star/V Guard
67Replacement of voltage stabilizer copper bound 4 KVA to 5KVA, input voltage range 90 volt to 220volt and output voltage 220 volt to 230 Volt AC + 2% variation of voltage with accessories etc., complete all as specified & directed. Make- Blue Star/V Guard
68Taking down compressor unit carefully from the refrigerator of capacity 286/310 Ltr and S&F new inverter compressor, charging of suitable refrigerant gas (enivornment friendly) and testing complete unit for required performance and smooth functioning for 24Hrs complete all as specified & directed. Make: Whirlpool/LG/Samsung/Godrej.
69All as per Ser item No 68 here-in-before but of capacity 165/175 Ltr capacity
70Replacement of cooling coil assly suitable for refrigerator 286/ 310 Ltrs capacity (as per sample) including nuts/bolts with door assly, complete all as specified & directed.
71All as per Ser item No 70 here-in-before but suitable for 165Ltr/175Ltr/180 Ltr capacity refrigerator.
72Replacement of copper filter of any type of refrigerator & deep freezer (as per sample), complete all as specified & directed.
73Replacement of timer for double door refrigerator (as per sample), complete all as specified & directed.
74Replacement of biometer for double door refrigerator (as per sample), complete all as specified & directed.
75Replacement of blower motor for double door refrigerator (as per sample), complete all as specified & directed.
76Replacement of starting relay for refrigerator (as per sample), complete all as specified & directed.Make: Godrej/LG/Whirlpool/Heir.
77Replacement of thermostat switch suitable for refrigerator (as per sample), complete all as specified & directed.
78Replacement of OLP of refrigerator (as per sample), complete all as specified & directed.
79Replacement of pin valve of refrigerator, air conditioner, water cooler (as per sample), complete all as specified & directed.
80Charging of Gas R-134a (450gm gas in each can) for suitable summer appliances including required brazing to pipe & connecting complete all as specified & directed.
81Repair/rewinding and maint of voltage stabilizer of any make and capacity 4 KVA upto 5 KVA after disconnecting the voltage stabilizer from machine, rewinding with super enamalled copper of existing gauge including replacement of u/s part like voltmeter, ammeter, cut out relay, electric circuit, indicator lamp, top plug, flexible wire including neccessary painting with two coats of synthetic enamel paint after proper sctretching and preparing the surface, complete all as specified and directed.
82Repair/rewinding and maint of voltage stabilizer of any make and capacity 1 KVA upto 3 KVA after disconnecting the voltage stabilizer from machine, rewinding with super enamalled copper of existing gauge including replacement of u/s part like voltmeter, ammeter, cut out relay, electric circuit, indicator lamp, top plug, flexible wire including neccessary painting with two coats of synthetic enamel paint after proper sctretching and preparing the surface, complete all as specified and directed.
83Capillery tube suitable size 0.31mm & 0.36mm suitable for refrigerator & deep Freezer (as per sample), complete all as specified and directed.
84Waste water cooler tray suitable for 40/80,60/120,150/150 ltr (as per sample), complete all as specified and directed.
85Re-charging of Gas R-32 for hot/cold air conditioner, complete all as specified and directed.
86Re-charging of Refrigerant R-600a for refrigerator any size (180gm gas in each can), complete all as specified and directed.
87Re-charging gas R-410 for air conditioner, complete all as specified and directed.
88Replacement of PCB circuit for inverter type refrigerator any capacity/any make (as per sample), complete all as specified and directed.
89Replacement of gasket for top cover of water cooler (as per sample), complete all as specified and directed.
90Replacement copper filter for any type of water cooler (as per sample), complete all as specified and directed.
91Replacement of heating condenser for refrigerator any capacity/ any type (as per sample), complete all as specified and directed.
92Replacement of stand shoes for refrigerator any cap (as per sample), complete all as specified and directed.
93Iron stand for split AC outdoor unit, complete all as specified and directed.
94Body of deep freezer of capacity 300/320 Ltrs (as per sample), complete all as specified and directed.
95Body of deep freezer of capacity 410/450 Ltrs (as per sample), complete all as specified and directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56497199
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 30 Lakhs
LAST DATE 06-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair And Maintenance Of Different Type Of Water Coolers, Desert Cooler, Air Conditioners, Refrigerators, Deep Freezers Including Misc Works Under Age E/M-Ii Of Ge (N) Mamun.
Basic Detail
Tender No GE(N)/M-45/2026-27
Bidding Type Tender
Location
City Pathankot
State Punjab
Key Dates
Publish Date 16 Jul 2026
Submission Date 06 Aug 2026
Open Date 14 Aug 2026
Finance
Tender Value 30 Lakhs
Tender Fee 500
EMD 60000
Exemption Not Available
Document List
31150ff7-5493-432d-a3ec-eb1f031954b1.html
BOQ_872457.xls
Tender45.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 06, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 19 days
Aug 14, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 27 days

Tender Documents

Download All (ZIP) ↓
html

31150ff7-5493-432d-a3ec-eb1f031954b1.html

xls

BOQ_872457.xls

pdf

Tender45.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders