Supply Of 1) VARIABLE ANGLE HIGH TIBIAL OSTEOTOMY PLATE (7 LOCKING AND 1 CORTICAL SCREW), 2) MRI COMPATIBLE SS PELVIC RECONSTRUCTION PLATE 3.5 CURVED-(A) 5HOLE L-20MM 5 CORTEX SCREWS, (B) 7HOLE L-22MM 7 CORTEX SCREWS,(C) 9HOLE L-24MM 9 COTEX SCREWS,
Tender Overview
Project Description
Supply Of 1) variable angle high tibial osteotomy plate (7 locking and 1 cortical screw), 2) mri compatible ss pelvic reconstruction plate 3.5 curved-(a) 5hole l-20mm 5 cortex screws, (b) 7hole l-22mm 7 cortex screws,(c) 9hole l-24mm 9 cotex screws, (d) 11hole l-26mm 11 cortex screws, (e) 13hole l-28mm 13 cotex screws, (f) 15hole l-30mm 15 cotex screws, (g) 18hole l-32mm 18 cortex screws, 3) periprosthetic titanium locking plate should be a long curved 4.5 mm broad lcp plates with 6 locking screws of 5mm size & 4) proximal femur locking plate- set containing 4.5mm proximal femur locking plate with multiple locking screw , srphc82419225-mri compatible ss pelvic reconstruction plate 3.5 curved-(a) 5h ole l-20mm 5 cortex screws, (b) 7hole l-22mm 7 cortex screws,(c) 9hole l-24mm 9 cotex screws, (d) 11hole l-26mm 11 cortex screws, (e) 13hole l-28mm 13 cotex screws, (f) 15hole l -30mm 15 cotex screws, (g) 18hole l-32mm 18 cortex screws. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419245-periprosthetic titanium locking plate should be a long curved 4.5 mm broad lcp plates with 6 locking screws of 5mm size .should be precontoured to mim ic the anteroposterior curvature and suture hole in the plate to allow temporary fixatio n. the tip of the plate should be tapered rounded to facilitate minimally invasive surgical procedures. should be available with 12 to 26 holes, screws with blunt tips two in number s to allow unicortical fixation of fractures when an intramedullary implant is present,ac company with two cortical screws and arthroplasty periprosthetic fracture control cab le including one control cable and one cable crip. each set along with complete set of ins trumentation. it must be supplied as and when required basis. the screw system merges lo cking screw technology with conventional plating technology. unit:set [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419223-variable angle high tibial osteotomy plate-should be made of m edical grade titanium. each set should consist of one variable angle high tibial osteotom y plate, 7 locking and 1 cortical screw. implant should be supplied with complete instrume nt set with plates and screws in all sizes as and when required basis. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419250-proximal femur locking plate- set containing 4.5mm proximal fe mur locking plate with multiple locking screw option in the proxmial femur, anatomically bowed shaft, both locking and non locking in every screw hole with right and left option s. the set should consist of eight locking screws and 2 cortical screws (all possible leng th needed for proximal femur fixation). each set supplied with complete set of instrumentation and should be mri compatible. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
BOQ
| Sl. No. | Item Description |
|---|---|
| 1 | SRPHC82419225-MRI COMPATIBLE SS PELVIC RECONSTRUCTION PLATE 3.5 CURVED-(A) 5H OLE L-20MM 5 CORTEX SCREWS, (B) 7HOLE L-22MM 7 CORTEX SCREWS,(C) 9HOLE L-24MM 9 COTEX SCREWS, (D) 11HOLE L-26MM 11 CORTEX SCREWS, (E) 13HOLE L-28MM 13 COTEX SCREWS, (F) 15HOLE L -30MM 15 COTEX SCREWS, (G) 18HOLE L-32MM 18 CORTEX SCREWS. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 2 | SRPHC82419245-PERIPROSTHETIC TITANIUM LOCKING PLATE SHOULD BE A LONG CURVED 4.5 MM BROAD LCP PLATES WITH 6 LOCKING SCREWS OF 5MM SIZE .SHOULD BE PRECONTOURED TO MIM IC THE ANTEROPOSTERIOR CURVATURE AND SUTURE HOLE IN THE PLATE TO ALLOW TEMPORARY FIXATIO N. THE TIP OF THE PLATE SHOULD BE TAPERED ROUNDED TO FACILITATE MINIMALLY INVASIVE SURGICAL PROCEDURES. SHOULD BE AVAILABLE WITH 12 TO 26 HOLES, SCREWS WITH BLUNT TIPS TWO IN NUMBER S TO ALLOW UNICORTICAL FIXATION OF FRACTURES WHEN AN INTRAMEDULLARY IMPLANT IS PRESENT,AC COMPANY WITH TWO CORTICAL SCREWS AND ARTHROPLASTY PERIPROSTHETIC FRACTURE CONTROL CAB LE INCLUDING ONE CONTROL CABLE AND ONE CABLE CRIP. EACH SET ALONG WITH COMPLETE SET OF INS TRUMENTATION. IT MUST BE SUPPLIED AS AND WHEN REQUIRED BASIS. THE SCREW SYSTEM MERGES LO CKING SCREW TECHNOLOGY WITH CONVENTIONAL PLATING TECHNOLOGY. UNIT:SET [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 3 | SRPHC82419223-VARIABLE ANGLE HIGH TIBIAL OSTEOTOMY PLATE-SHOULD BE MADE OF M EDICAL GRADE TITANIUM. EACH SET SHOULD CONSIST OF ONE VARIABLE ANGLE HIGH TIBIAL OSTEOTOM Y PLATE, 7 LOCKING AND 1 CORTICAL SCREW. IMPLANT SHOULD BE SUPPLIED WITH COMPLETE INSTRUME NT SET WITH PLATES AND SCREWS IN ALL SIZES AS AND WHEN REQUIRED BASIS. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |
| 4 | SRPHC82419250-PROXIMAL FEMUR LOCKING PLATE- SET CONTAINING 4.5MM PROXIMAL FE MUR LOCKING PLATE WITH MULTIPLE LOCKING SCREW OPTION IN THE PROXMIAL FEMUR, ANATOMICALLY BOWED SHAFT, BOTH LOCKING AND NON LOCKING IN EVERY SCREW HOLE WITH RIGHT AND LEFT OPTION S. THE SET SHOULD CONSIST OF EIGHT LOCKING SCREWS AND 2 CORTICAL SCREWS (ALL POSSIBLE LENG TH NEEDED FOR PROXIMAL FEMUR FIXATION). EACH SET SUPPLIED WITH COMPLETE SET OF INSTRUMENTATION AND SHOULD BE MRI COMPATIBLE. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ] |