Railways Government Departments Closing in 21 days TDR #56496218

Supply Of 1) VARIABLE ANGLE HIGH TIBIAL OSTEOTOMY PLATE (7 LOCKING AND 1 CORTICAL SCREW), 2) MRI COMPATIBLE SS PELVIC RECONSTRUCTION PLATE 3.5 CURVED-(A) 5HOLE L-20MM 5 CORTEX SCREWS, (B) 7HOLE L-22MM 7 CORTEX SCREWS,(C) 9HOLE L-24MM 9 COTEX SCREWS,

Issued by Government Departments · , Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Aug 2026
21 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Tamil Nadu
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of 1) variable angle high tibial osteotomy plate (7 locking and 1 cortical screw), 2) mri compatible ss pelvic reconstruction plate 3.5 curved-(a) 5hole l-20mm 5 cortex screws, (b) 7hole l-22mm 7 cortex screws,(c) 9hole l-24mm 9 cotex screws, (d) 11hole l-26mm 11 cortex screws, (e) 13hole l-28mm 13 cotex screws, (f) 15hole l-30mm 15 cotex screws, (g) 18hole l-32mm 18 cortex screws, 3) periprosthetic titanium locking plate should be a long curved 4.5 mm broad lcp plates with 6 locking screws of 5mm size & 4) proximal femur locking plate- set containing 4.5mm proximal femur locking plate with multiple locking screw , srphc82419225-mri compatible ss pelvic reconstruction plate 3.5 curved-(a) 5h ole l-20mm 5 cortex screws, (b) 7hole l-22mm 7 cortex screws,(c) 9hole l-24mm 9 cotex screws, (d) 11hole l-26mm 11 cortex screws, (e) 13hole l-28mm 13 cotex screws, (f) 15hole l -30mm 15 cotex screws, (g) 18hole l-32mm 18 cortex screws. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419245-periprosthetic titanium locking plate should be a long curved 4.5 mm broad lcp plates with 6 locking screws of 5mm size .should be precontoured to mim ic the anteroposterior curvature and suture hole in the plate to allow temporary fixatio n. the tip of the plate should be tapered rounded to facilitate minimally invasive surgical procedures. should be available with 12 to 26 holes, screws with blunt tips two in number s to allow unicortical fixation of fractures when an intramedullary implant is present,ac company with two cortical screws and arthroplasty periprosthetic fracture control cab le including one control cable and one cable crip. each set along with complete set of ins trumentation. it must be supplied as and when required basis. the screw system merges lo cking screw technology with conventional plating technology. unit:set [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419223-variable angle high tibial osteotomy plate-should be made of m edical grade titanium. each set should consist of one variable angle high tibial osteotom y plate, 7 locking and 1 cortical screw. implant should be supplied with complete instrume nt set with plates and screws in all sizes as and when required basis. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419250-proximal femur locking plate- set containing 4.5mm proximal fe mur locking plate with multiple locking screw option in the proxmial femur, anatomically bowed shaft, both locking and non locking in every screw hole with right and left option s. the set should consist of eight locking screws and 2 cortical screws (all possible leng th needed for proximal femur fixation). each set supplied with complete set of instrumentation and should be mri compatible. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]

BOQ

Sl. No.Item Description
1SRPHC82419225-MRI COMPATIBLE SS PELVIC RECONSTRUCTION PLATE 3.5 CURVED-(A) 5H OLE L-20MM 5 CORTEX SCREWS, (B) 7HOLE L-22MM 7 CORTEX SCREWS,(C) 9HOLE L-24MM 9 COTEX SCREWS, (D) 11HOLE L-26MM 11 CORTEX SCREWS, (E) 13HOLE L-28MM 13 COTEX SCREWS, (F) 15HOLE L -30MM 15 COTEX SCREWS, (G) 18HOLE L-32MM 18 CORTEX SCREWS. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]
2SRPHC82419245-PERIPROSTHETIC TITANIUM LOCKING PLATE SHOULD BE A LONG CURVED 4.5 MM BROAD LCP PLATES WITH 6 LOCKING SCREWS OF 5MM SIZE .SHOULD BE PRECONTOURED TO MIM IC THE ANTEROPOSTERIOR CURVATURE AND SUTURE HOLE IN THE PLATE TO ALLOW TEMPORARY FIXATIO N. THE TIP OF THE PLATE SHOULD BE TAPERED ROUNDED TO FACILITATE MINIMALLY INVASIVE SURGICAL PROCEDURES. SHOULD BE AVAILABLE WITH 12 TO 26 HOLES, SCREWS WITH BLUNT TIPS TWO IN NUMBER S TO ALLOW UNICORTICAL FIXATION OF FRACTURES WHEN AN INTRAMEDULLARY IMPLANT IS PRESENT,AC COMPANY WITH TWO CORTICAL SCREWS AND ARTHROPLASTY PERIPROSTHETIC FRACTURE CONTROL CAB LE INCLUDING ONE CONTROL CABLE AND ONE CABLE CRIP. EACH SET ALONG WITH COMPLETE SET OF INS TRUMENTATION. IT MUST BE SUPPLIED AS AND WHEN REQUIRED BASIS. THE SCREW SYSTEM MERGES LO CKING SCREW TECHNOLOGY WITH CONVENTIONAL PLATING TECHNOLOGY. UNIT:SET [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]
3SRPHC82419223-VARIABLE ANGLE HIGH TIBIAL OSTEOTOMY PLATE-SHOULD BE MADE OF M EDICAL GRADE TITANIUM. EACH SET SHOULD CONSIST OF ONE VARIABLE ANGLE HIGH TIBIAL OSTEOTOM Y PLATE, 7 LOCKING AND 1 CORTICAL SCREW. IMPLANT SHOULD BE SUPPLIED WITH COMPLETE INSTRUME NT SET WITH PLATES AND SCREWS IN ALL SIZES AS AND WHEN REQUIRED BASIS. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]
4SRPHC82419250-PROXIMAL FEMUR LOCKING PLATE- SET CONTAINING 4.5MM PROXIMAL FE MUR LOCKING PLATE WITH MULTIPLE LOCKING SCREW OPTION IN THE PROXMIAL FEMUR, ANATOMICALLY BOWED SHAFT, BOTH LOCKING AND NON LOCKING IN EVERY SCREW HOLE WITH RIGHT AND LEFT OPTION S. THE SET SHOULD CONSIST OF EIGHT LOCKING SCREWS AND 2 CORTICAL SCREWS (ALL POSSIBLE LENG TH NEEDED FOR PROXIMAL FEMUR FIXATION). EACH SET SUPPLIED WITH COMPLETE SET OF INSTRUMENTATION AND SHOULD BE MRI COMPATIBLE. [Quantity Tolerance (+/-): 5 %age , Item Category : Normal , Total PO value variation Permitted: Max 8 lacs ] ]

AI Tender Summary

OUR REF NO 56496218
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 13-08-2026
Authority
Authority Name Southern Railway
Work Description Supply Of 1) variable angle high tibial osteotomy plate (7 locking and 1 cortical screw), 2) mri compatible ss pelvic reconstruction plate 3.5 curved-(a) 5hole l-20mm 5 cortex screws, (b) 7hole l-22mm 7 cortex screws,(c) 9hole l-24mm 9 cotex screws, (d) 11hole l-26mm 11 cortex screws, (e) 13hole l-28mm 13 cotex screws, (f) 15hole l-30mm 15 cotex screws, (g) 18hole l-32mm 18 cortex screws, 3) periprosthetic titanium locking plate should be a long curved 4.5 mm broad lcp plates with 6 locking screws of 5mm size & 4) proximal femur locking plate- set containing 4.5mm proximal femur locking plate with multiple locking screw , srphc82419225-mri compatible ss pelvic reconstruction plate 3.5 curved-(a) 5h ole l-20mm 5 cortex screws, (b) 7hole l-22mm 7 cortex screws,(c) 9hole l-24mm 9 cotex screws, (d) 11hole l-26mm 11 cortex screws, (e) 13hole l-28mm 13 cotex screws, (f) 15hole l -30mm 15 cotex screws, (g) 18hole l-32mm 18 cortex screws. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419245-periprosthetic titanium locking plate should be a long curved 4.5 mm broad lcp plates with 6 locking screws of 5mm size .should be precontoured to mim ic the anteroposterior curvature and suture hole in the plate to allow temporary fixatio n. the tip of the plate should be tapered rounded to facilitate minimally invasive surgical procedures. should be available with 12 to 26 holes, screws with blunt tips two in number s to allow unicortical fixation of fractures when an intramedullary implant is present,ac company with two cortical screws and arthroplasty periprosthetic fracture control cab le including one control cable and one cable crip. each set along with complete set of ins trumentation. it must be supplied as and when required basis. the screw system merges lo cking screw technology with conventional plating technology. unit:set [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419223-variable angle high tibial osteotomy plate-should be made of m edical grade titanium. each set should consist of one variable angle high tibial osteotom y plate, 7 locking and 1 cortical screw. implant should be supplied with complete instrume nt set with plates and screws in all sizes as and when required basis. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ] , srphc82419250-proximal femur locking plate- set containing 4.5mm proximal fe mur locking plate with multiple locking screw option in the proxmial femur, anatomically bowed shaft, both locking and non locking in every screw hole with right and left option s. the set should consist of eight locking screws and 2 cortical screws (all possible leng th needed for proximal femur fixation). each set supplied with complete set of instrumentation and should be mri compatible. [quantity tolerance (+/-): 5 %age , item category : normal , total po value variation permitted: max 8 lacs ] ]
Basic Detail
Tender No 02265223
Bidding Type Tender
Location
City
State Tamil Nadu
Key Dates
Publish Date 15 Jul 2026
Submission Date 13 Aug 2026
Open Date 01 Jan 0001
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
46f982c9-84ac-4f5f-be3f-aecbadee3fa2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 13, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 21 days

Tender Documents

Download All (ZIP) ↓
pdf

46f982c9-84ac-4f5f-be3f-aecbadee3fa2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders