Tender For Provision Of Covered Shelter For Security Personnel At Entrance Gate Of Married Accomodation At New Town Kolkata Under Ge (I) (Cg&N) Kolkata
Tender Value
43.90 Lakhs
Estimated cost
Bid Submission
06 Aug 2026
19 days left
EMD
87800
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kolkata → West Bengal
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Provision Of Covered Shelter For Security Personnel At Entrance Gate Of Married Accomodation At New Town Kolkata Under Ge (I) (Cg&N) Kolkata
BOQ
| Sl. No. | Item Description |
| 1 | Demolition of reinforced Concrete of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 2 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 3 | Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 4 | Excavating over areas exc 1.5m and n.exc 3.0 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 5 | M & L for plain cement concrete (1:4:8) type D2(using 40 mm stone aggregate) as in foundation, filling and mass concrete complete all as specified and as directed. |
| 6 | M&L for Use & waste of formwork to sides of foundations,pile cap, footing,grid beam,plinth beam etc of Rough finished square, rectangular or polygonal surface complete all as specified and as directed. |
| 7 | M&L for Use and waste of Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed. |
| 8 | M&L for Mild steel TMT bars, 10 mm dia and over cut to length bent to shape required , including cranking , bending, spirally for hooping for columns , hooking ends and binding with mild steel wire (annealed) not less 0.9mm dia of securing with clips complete all as specified and directed. |
| 9 | M&L for Mild steel TMT bars, of 5 mm dia and over upto and including 10mm dia, cut to length bent to shape required , including cranking , bending, spirally for hooping for in stirrups, spacers and binders complete all as specified and as directed. |
| 10 | M & L for Reinforced Cement Concrete (Design Mix) of M30 grade concrete in foundation including raft, foundation beams, plinth beam, bases for columns etc footing basement slabs, under-reamed piles and mass concrete complete all as specified and directed. |
| 11 | M & L design Mix RCC M30 grade concrete with 20mm down graded aggregate in columns, pillars, piers, posts and struts etc. complete all as specified and directed. |
| 12 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe 410 -W (Gde- E- 250) quality-A complete all as specified and directed. |
| 13 | M&L Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe- 290 (Gde E- 165) complete all as specified and as directed. |
| 14 | S&F quality Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete of grade Fe 410-W (Gde- E- 250) quality complete all as specified and directed. |
| 15 | M & L two coats of synthetic enamel paint over a coat of red oxide primer on steel surfaces including preparation of steel surfacea width or girth exc 10cm all as specified and directed. |
| 16 | Returning, filling in, incl spreading, leveling, watering and well ramming in layers n exc 25 cm as in soft/loose soil complete all as specified and as directed. |
| 17 | Removing excavated material exc 250 m but n exc 500m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and as directed. |
| 18 | Material & Labour for providing and fixing stainless steel (Grade 304) tension cable of 20 mm dia and etc including welding, grinding, buffing, polishing and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the cable with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, at any level complete all as specified and as directed. |
| 19 | M & L for 25 mm thick non shrink pre mix grout like sika grout 214 IN or equivalent and apply over concrete head with manufacture instruction and drawing specification including formwork and preparation of head of columncomplete all as specified and directed by Engr-in-Charge |
| 20 | Designing, fabricating, testing, installing and fixing in position Curtain Wall with Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear portions of the building , for all heights and all levels ete. including:(a) Structural analysis & design and preparation of shop drawings for pressure equalisation or rain screen principle as required, proper drainage of water to make it watertight including checking of all the structural and functional design.(b) Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metalic colour of approved shades made out of 4 mm thick aluminium composite panel material consisting of 3 mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5 mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.(c) The fastening brackets of Aluminium alloy 6005 T5 / MS with Hot Dip Galvanised with serrations and serrated washers to arrest the wind load movement, fasteners, SS 316 Pins and anchor bolts of approved make in SS 316, Nylon separators to prevent bi-metallic contacts all complete required to perform as per specification and drawing The item includes cost of all material & labour component, the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working curtain wall with aluminium composite panel cladding, cleaning and protection of the curtain wall with aluminium composite panel cladding till the handing over of the building for occupation. Base frame work for ACP cladding is payable under the relevant aluminium items. The Contractor shall provide curtain wall with aluminium composite panel cladding, having all the performance characteristics all complete , as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer-in-Charge. However, for the purpose of payment, only the actual area on the external face of the curtain wall with Aluminum Composite Panel Cladding (including width of groove) shall be measured in sqm. up to two decimal places. |
| 21 | S&F for 3 dimensional steel letter (English) in SS golden coated on the wall size up to 18\\" hight with back side LED light, including background ACP box suitable sioze for fixing the letters in wall with complete all as specified and directed by Engr-in-Charge |
| 22 | S&F for 3 dimensional steel letter (Hindi) in SS golden coated on the wall size up to 18\\" hight with back side LED light, including background ACP box suitable sioze for fixing the letters in wall with complete all as specified and directed by Engr-in-Charge |
| 23 | M&L for concealed point wiring with 1.5 sqmm PVC insulated FRLSH sheathed 1100Volts grade copper multi stranded conductor drawn through and including rigid PVC conduit 20mm dia concealed in walls roofs, etc including 1.5 sqmm PVC isulated copper conductor as earth continuity conductor and other accessories such as metal box, sheet cover, screws, nuts etc connecting it to the common earth dolly all as specified for one light/ceiling fan/Exhaust fan/wall fan each controller by one way switch complete all as specified and as directed |
| 24 | All as per item No 23 above but one 3 pin 5 Amps socket outlet on same board controlled by one switch complete all as specified and as directed |
| 25 | All as per item No 23 above but for one socket outlet, 5 amp on independent board complete all as specified and as directed |
| 26 | M & L for concelaed Wiring for circuit/submain wiring alongwith earth wire, with the following sizes of FR PVC insulated copper conductor, single core cable in surface/recessed as required in PVC Conduit concelled type 2X2.5 sq. mm+1X2.5 sq. mm for earth wire all as specified and directed |
| 27 | M & L for Switch Modular type single pole, one way 6 Amp cmplete all as directed and as specified |
| 28 | M & L Socket, 6A-2/3 pin combined 2 module complete all as directed and as specified |
| 29 | S & F modular metal box 3 module complete all as specified and as directed |
| 30 | S & F modular white cover plate with frame 3 way incl complete all as specified and as directed |
| 31 | S&F Modular White cover plate with frame 8/12 Module complete all as directed and as specified |
| 32 | S&F Metal/ PVC flush box 8/12 module complete all as directed and as specified |
| 33 | Supply and fixing SP 6-32 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and currrent carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed |
| 34 | Supply and fixing SPN 40-63 amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and currrent carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and as directed |
| 35 | Suppy and fix sheet steel enclosure 4 way TPN DB with 200 amps bus bar with provision for TPN MCB as incomer, double door type all as specified and as directed |
| 36 | M&L MCB TPN FP 'B' series 40-100 Amp complete all as specified and as directed |
| 37 | Supply and fixing MCCB, 80 to 100 Amps, 4 pole, 36 KA breaking capacity 415 Volts with necessary cable lugs in existing panel complete all as specified and directed. |
| 38 | Supply and fix 12 way SPN double door DB with 200 amps rated bus bar complete with connection testing and commissioning complete all as specified and as directed |
| 39 | Supply and fix Quartz daily on off on type, 240 V analogue type timer for switching street light complete with connection testing and commmissioning complete all as specified and as directed |
| 40 | Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete complete all as specified and as directed |
| 41 | Supply, laying and testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cbales (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 Sq mm 4 Core including excavation and laying in DWC pipe laid under floors/ roads through concealed DWC pipe (cost included) in ground as per site requirement complete all as specified and directed. |
| 42 | Excavating in trenches n. exc . 1.5m. Wide and n. exc. 1.5m. In depth; for foundation etc. or for shafts, wells cesspits, manholes, pire holes, etc. n. exc. 10 sqm on pan and not exc.1.5m. In depth and getting out in soft/loose soil complete all as specified and as directed |
| 43 | M&L for sand cushioning for protection of cables (below, aboe and around the cable laid in trenches) complete using clean, dry sand complete all as speicfied and as directed. |
| 44 | Supply and laying well burnt bricks sub class 'B' laid breadthwise alonglength of cable in trenches after sand cushioning laid for underground cable protection complete all as specified and as directed. |
| 45 | Removing excavated soil not exc 50 mtr and depositing where directed at a level not exceeding 25CM in soft/loose soil complete all as specified and asn directed |
| 46 | Supply and laying 50mm dia steel water tube light greade galvanised with all fittngs laid in trenches for cable suporting complete all as specified and as directed |
| 47 | Supply and fixing of LED floood light minimum 170 watt 230 V AC outdoor type with tehrmal management in multiple otpics and euippped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed |
| 48 | Supply and fixing LED strips 24 watt with clour each with 5.00mtr length as specified by Engr-in-Charge including driver and all fittings complete all as specified and directed. |
| 49 | M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 06, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 19 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender