Tender For Repair/Maint Of Lt Panels, Feeder Pillar Boxes, Mccbs, Junction Boxes To Buildings And Connected Items In Zone A & B Tech Area Under Ge (Af) Tech Area Agra
Tender Value
42 Lakhs
Estimated cost
Bid Submission
07 Aug 2026
15 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ahmedabad → GUJARAT
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Maint Of Lt Panels, Feeder Pillar Boxes, Mccbs, Junction Boxes To Buildings And Connected Items In Zone A & B Tech Area Under Ge (Af) Tech Area Agra
BOQ
| Sl. No. | Item Description |
| 1 | Supply, Fix & install in repair MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed as mentioned below:-a) MCCB 160 Amps, 36KA , 4 pole with thermal magnetic release -01 Nob) MCCB sheet steel enclosure 'A' Frame FP - 01 No |
| 2 | Supply, Fix & install in repair MCCB with factory made sheet metal enclosure with provision of cable connection for incoming and outgoing complete all as specified and directed as mentioned below:-a) MCCB 250 Amps, 36KA , 4 pole with thermal magnetic release -01 Nob) MCCB sheet steel enclosure 'A' Frame FP - 01 No |
| 3 | Demolition of PCC/Black bituminous road of any description and in any position not otherwise specially provided , etc complete all as specified and directed. |
| 4 | M&L for PCC (1:2:4) type B1 using 20 mm gradded stone aggregate for coping of poles, panel board etc complete all as specified and as directed. |
| 5 | M&L for rendering 10 mm thick in CM 1:4 on fair faces of brick work or concrete surfaces and finished the surfaces fair and even complete all as specified and as directed. |
| 6 | Supply and fixing PVC insulated heavy duty electric cable unarmoured with stranded aluminium conductor complete all as specified and directed of the following sizes:- |
| 7 | 2 core, 4 Sqmm |
| 8 | 2 core, 6 Sqmm |
| 9 | 2 core, 10 Sqmm |
| 10 | Design, supply, erection, testing and commissioning of outdoor type LT Feeder Pillar Box of overall size not less than 1600mm width x 1200mm Height (With Canopy & Base Channel) x 400mm Depth, M.S. Channel Base Frame mounted (to be mounted on the 3 side covered brick. pedestal of height 600mm above ground level) , suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating 1000 amps, Provision of Spreader link to both incoming & Outgoing MCCBs for termination of cables . The Feeder Pillar shall be duly fabricated in a approved / certified factory / fabrication House who posseses type test certificate from CPRI for similar type of Feeder Pillar and having modern fabrication and testing facility which includes atleast seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron) with approved shade of RAL 7032 (SIEMENS GRAY). The Feeder Pillar shall be provided with suitable rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having compartmentalized construction for individual switchgears and Bus Bars and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel channel (MC-75) base frame at bottom, suitable for mounting on the brick pedestal through grouting bolt, The panel board shall be provided with ventilation facility in the form of louvers for better heat dissipation. The feeder pillar shall be comprising of the followings :- |
| 11 | PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 1000 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mmCONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 50 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 630 Amps-01 No. Please Enable Macros to View BoQ information SCHEDULE OF CREDIT 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in (Rs) |
| 12 | PROVISION FOR CABLE ENTRY :- The provision for cable entry / exit shall be provided from the bottom for both incoming and outgoing cables. BUS BARS & INTERNAL CONNECTIONS :- The bus bars should be made of Aluminium, duly insulated with 1100 volts grade standard colour coded heat shrink type PVC sleeves and rigidly mounted on suitable size 'F' class insulators of non hygroscopic non combustable, track resistant, high strength FRP / SMC / DMC material. 4 Nos Aluminium bus bars of rating 1000 amps, . For all internal connections from main bus bars to MCCBS shall be carried out with heat shrink type PVC insulated aluminium flats of suitable size and from bus bars to MCBs with suitable size FRLS PVC insulated multi flexible type copper wires as per the current carrying capacity of individual switch gears. Earthing bar shall be provided as per standard practice and shall be made of Galvanized Steel flats of size 25mm x 6 mmCONTROL WIRING :- All control wirings shall have to be carried out with 1100 volts rated FRLS grade PVC insulated (Gray Colour) multi-flexible type copper wire of cross sectional area 1.50 Sq mm and shall be properly bunched,tied and dressed, ferrule marked for proper identification and crimped with suitable size & type of tinned copper lugs and shall be wrapped with PVC spring type flexible pipes near the door hinges.INCOMING :- (i) 4 pole MCCB ( with panel mounted rotary handle ) having breaking capacity 50 KA, Fixed magnetic and adjustable thermal setting from 80% to 100% and of rating 630 Amps-01 No. Please Enable Macros to View BoQ information SCHEDULE OF CREDIT 1. All worn out/unserviceable materials/items which will be obtained from different items of Sch `A’/ BOQ (as mentioned above) during replacement work, shall become contractor’s property and amount of credit shall be recovered from the contractor's RAR & final bill as and when payments are submitted. These materials shall be allowed to be removed from works site only after credit amount for the same is recovered from the contractor’s payment. Items not covered under this Schedule shall become the property of department and the same shall be returned/ deposited by the contractor at MES store yard without any extra cost to department/ government and all materials which are credited to the contractor, shall be recorded in MB 2. The contractor shall have no claim regarding fixation of credit rates in this schedule and no rebate on \\"Schedule of credit\\" rates/ amount shall be accepted. However contractor can offer more credit rates/ amount. 3. The total credit amount may vary as per execution of work above different items involved in this credit schedule. 4. The quantities given in column 4 are provisional and same shall be measured and paid based on actual quantities obtained against relevant items of Schedule ‘A’/ BOQ. These materials shall not be reused/ reincorporated in the work except where specified. 5. The measurements of dismantled materials shall be the gross quantity obtained and not the net quantity considered for payment in schedule. The old and unserviceable materials to be retrieved from taking down/demolition/dismantling etc are considered in schedule of credit. No claim of contractor with regard to quality/position of old materials shall be entertained Srl No Description of item Qty Unit Assessed rate by department Remarks Rate in (Rs) Amount in (Rs) |
| 13 | Old unserviceable Sheet metal enclosure With MCCB of any size |
| 14 | Old unserviceable LT Panel of any size |
| 15 | Old unserviceable Bus Bar of any size |
| 16 | Old unserviceable PVC insulated unarmoured cable of any size |
| 17 | Old unserviceable Earthing |
| 18 | Old unserviceable aluminium lugs |
| 19 | Old unserviceable MCCB any size |
| 20 | Old unserviceable CTs of any size Total amount of credit schedule 57520.0 Signature of contractor AGE (Contracts) For ACCEPTING OFFICER |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 07, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 20 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender