Power Government Departments Closing in 3 days TDR #56490859

Tender For To Provide The New Connections And Other Works Under Full Deposit Scheme Edd Najibabad Running

Issued by Government Departments · Dhampur, Uttar Pradesh
Tender Value
20 Lakhs
Estimated cost
Bid Submission
25 Jul 2026
3 days left
EMD
20000
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dhampur → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For To Provide The New Connections And Other Works Under Full Deposit Scheme Edd Najibabad Running- 1 Safe Carriage Of The Following Material From Store Centre, Bijnor To Work Site Including Loading And Unloading At Both Ends :- 2 13 Mtr./11 Mtr./9 Mtr./8.5 Mtr. Long Pcc/St Poles. 3 Acsr Weasel/Rabbit/Dog Conductor. 4 11/0.4 10 Kva Transformers. 5 11/0.4 25 Kva Transformers. 6 11/0.4 63 Kva Transformers. 7 11/0.4 100 Kva Transformers. 8 11/0.4 250 Kva Transformers. 9 Lt A.B.C. Cable. 10 11 Kv Xlpe Cable Of Size 3X70 Sq.Mm./ 3X120 Sq.Mm./ 3X180 Sq.Mm. Etc. 11 33 Kv Xlpe Cable Of Size 3X120 Sq.Mm./ 3X300 Sq.Mm. Etc. 12 Line Material Such As Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators And Cable Jointing Kits Etc. 13 Ct/Pt Unit 14 11 Kv Pilfer Proof Metering Cubical. 15 Dismentalling Of 11 Kv/33 Kv Line. 16 Removing Of Acsr Weasel/Rabbit/Dog Conductor From All Phases On Line, Making Bundle And Stacking At A Safe Place. 17 Uprooting Of 13 Mtr./11 Mtr./9 Mtr Long St Poles. 18 33 Kv Ct/Pt 19 11 Kv Ct/Pt 20 For 11 Kv/33 Kv Line, Single Support 13/11/9/8.5 Mtr. Long St/Pcc Poles :- Excavation Of Foundation Pit In Size Of 75X45 Cm. Having Depth Of 1/6Th Of The Full Length Of The Support (Pole), Providing And Laying Of Stone Pad (300X300X75Mm.) In The Bottom Of The Pit. Erection Of Single Pole Support Complete With Fixing Of 11 Kv V-Type Cross-Arms And All Other Accessories By Providing Stone Pad, Holding Clamps, F-Bracket And Nuts & Bolts Etc. As Per Respo Norms. 21 For 11 Kv/33 Kv Line, Double Pole Structure With 13/11/9/8.5 Mtr. Long St/Pcc Poles :- Excavation Of Foundation Pit In Size Of 75X45 Cm. Having Depth Of 1/6Th Of The Full Length Of The Support (Pole). Erection Of Support (Pole) Complete Work By Fixing Of D.P. Clamps And All Other Accessories. The Work Includes Fabrication Work And Fixing Of Cross Bracing Sets, Cutting Holes Complete Work As Per Respo Norms. 22 Grouting Of Poles Single Line Support :- Grouting Of Support In Cc 1:4:6 (Cement, Sand And 40 Mm. Brick Ballast) Grouting Will Be Done In The Block Of Size 45Cm X 45Cm X 1/6Th Of Full Length Of The Support Upto Ground Level As Per Respo Norms. 23 Grouting Of Stay Rods (20X1800Mm.) Including All Works Of Excavation, Cement Concrete In Size Of (0.60X0.60X0.30)M In The Ratio Of 1:4:6 (Cement, Sand And 40 Mm. Brick Ballast) Including Back Filling Of Soil And Proper Ramming Etc. 24 Fixing, Tightening And Nozelling Of Stay Wire With Stay Rod And Stay Insulators With The Pole Of Required Tension By Providing Stay Clamps, Nuts, Bolts Etc. 25 Earthing Of Support With Ms Earth Rod Of (20X2500)Mm. Long Including Excavation Of Pit And Driving Ms Rod 3.0M Apart From Support And 0.5M Below The Ground Level And Connecting Below The Earth Electrodes With The Help Of G.I. Wire 6 Swg Tightening With Nuts And Bolts. 26 Laying, Sagging, Stringing And Binding Of Acsr Weasel/ Dog Conductor With All Other Accessories On Pole As Per Respo Norms. 27 Laying, Sagging, Stringing And Binding Of Abc Conductor With All Other Accessories On Pole As Per Respo Norms. 28 Laying Of 11 Kv Xlpe Cable Of Size 3X70 Sq.Mm./ 3X120 Sq.Mm./ 3X180 Sq.Mm. & 33 Kv Xlpe Cable Of Size 3X120Sq.Mm/3X300 Sq.Mm And Making Connections As Per Respo Norms. 29 Filling And Fixing Of 11 Kv Outdoor/Indoor Type Cable Jointing Kits As Per Respo Norms. 30 Digging Of Cable Trench In Size Of 0.45Mtr.X1.05 Mtr. 31 Laying Of 11 Kv 3X70/120/185 Sq.Mm. Cable & 33 Kv 3X120/300 Sq.Mm. Cable In The Trench. 32 Providing 150 Mm. Sand Cushion Beneath And 150 Mm. Above The Cable. The Cable Shall Be Duly Protected By 1St Class Bricks, Two On Either Side And Third On Top Of The Cable, Laid In The Series One After The Other. 33 Refilling And Ramming Of The Left Out Soil, Closing The Trench And Levelling. Spare Cable Shall Be Left In The Loop Shape At Both Ends, Including Providing Of All Required Material And T&P. 34 Providing And Fixing Of Danger Board With Clamp, Nut And Bolts. 35 Providing And Fixing Of Number Plate With Clamp, Nut And Bolts. 36 Providing And Wrapping Of Barbed Wire On 11 Kv Pcc Poles At A Height Of 2.75 Mtr. From The Ground Level As Per Respo Norms. 37 Fitting Of 11 Kv Pilfer Proof Metering Cubical Including Making Proper Connections. 38 Guarding Of 11 Kv/33 Kv Line With G.I. Wire As Per Respo Norms. 39 Mounting And Fixing Of 11 Kv Ct/Pt Unit On Double Pole Including Making Proper Connections. 40 Mounting And Fixing Of 10 Kva Transformer On Pole Including Making Proper Connections. 41 Mounting And Fixing Of 25 Kva Transformer On Double Pole Including Making Proper Connections. 42 Mounting And Fixing Of 63 Kva Transformer On Double Pole Including Making Proper Connections. 43 Mounting And Fixing Of 100 Kva Transformer On Double Pole Including Making Proper Connections. 44 Safe Installation Of 250 Kva Transformer On Plinth, Making H.T./L.T. Connections And All Other Work As Per Respo Norms. 45 Providing G.I. Pipe 6” Dia For Inserting 11 Kv/33 Kv Xlpe Cable For Safety Of Cable On Single/Double Pole By Providing And Fixing Of Ms Clamp, Nuts And Bolts. 46 Fixing And Fitting Of Single/Three Phase Distribution Box On Pole For Making Consumers Cable Connection Complete Work. 47 Making Of Distribution Transformer Plinth With Fencing 250 To 630 Kva As Per Respo Norms. 48 Back Carriage Of Following From Work Site To Store Centre, Bijnor Including Loading And Unloading At Both Ends :- 49 13 Mtr./11 Mtr./9 Mtr. Long St Poles. 50 Acsr Weasel/Rabbit/Dog Conductor/M.S. Scrap. 51 Ms Steel Scrap

BOQ

Name of Work:- fo|qr forj.k [k.M] uthckckn ds {ks=kUrxZr iw.kZ tek ;kstuk esa Lohd`r izkDdyuksa@iSdstksa ds lkis{k >ViV iksVZy ,oa fuosk fe= iksVZy ds ek/;e ls izkIr la;kstuksa dks fu/kkZfjr le;kof/k ds Hkhrj Åthd`r djus ,oa ubZ ykbu fuekZ.k dk;Z] iksy] ,y-Vh-@33@11 dsoh ykbu fkf¶Vax@{kerko`f) dk;Z ¼jfuax dkWUVªsDV ds vk/kkj ij½A
Sl. No. Item Description
1Safe carriage of the following material from Store Centre, Bijnor to work site including loading and unloading at both ends :-
213 Mtr./11 Mtr./9 Mtr./8.5 Mtr. Long PCC/ST Poles.
3ACSR Weasel/Rabbit/Dog Conductor.
411/0.4 10 KVA Transformers.
511/0.4 25 KVA Transformers.
611/0.4 63 KVA Transformers.
711/0.4 100 KVA Transformers.
811/0.4 250 KVA Transformers.
9LT A.B.C. Cable.
1011 KV XLPE cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. etc.
1133 KV XLPE cable of size 3x120 sq.mm./ 3x300 sq.mm. etc.
12Line material such as Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators and Cable Jointing Kits etc.
13CT/PT Unit
1411 KV pilfer proof metering cubical.
15Dismentalling of 11 KV/33 KV Line.
16Removing of ACSR Weasel/Rabbit/Dog conductor from all phases on line, making bundle and stacking at a safe place.
17Uprooting of 13 Mtr./11 Mtr./9 Mtr Long ST Poles.
1833 KV CT/PT
1911 KV CT/PT
20For 11 KV/33 KV Line, Single support 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole), providing and laying of stone pad (300x300x75mm.) in the bottom of the pit. Erection of single pole support complete with fixing of 11 KV V-Type cross-arms and all other accessories by providing stone pad, holding clamps, f-bracket and nuts & bolts etc. as per RESPO Norms.
21For 11 KV/33 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long ST/PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms.
22Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms.
23Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.
24Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc.
25Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire 6 SWG tightening with nuts and bolts.
26Laying, sagging, stringing and binding of ACSR Weasel/ Dog Conductor with all other accessories on pole as per RESPO Norms.
27Laying, sagging, stringing and binding of ABC Conductor with all other accessories on pole as per RESPO Norms.
28Laying of 11 KV XLPE Cable of size 3x70 sq.mm./ 3x120 sq.mm./ 3x180 sq.mm. & 33 KV XLPE Cable of size 3x120sq.mm/3x300 sq.mm and making connections as per RESPO Norms.
29Filling and fixing of 11 KV outdoor/indoor type cable jointing kits as per RESPO Norms.
30Digging of cable trench in size of 0.45Mtr.x1.05 Mtr.
31Laying of 11 KV 3x70/120/185 sq.mm. cable & 33 KV 3x120/300 sq.mm. Cable in the trench.
32Providing 150 mm. sand cushion beneath and 150 mm. above the cable. The cable shall be duly protected by 1st Class Bricks, two on either side and third on top of the cable, laid in the series one after the other.
33Refilling and ramming of the left out soil, closing the trench and levelling. Spare cable shall be left in the loop shape at both ends, including providing of all required material and T&P.
34Providing and fixing of Danger Board with clamp, nut and bolts.
35Providing and fixing of Number Plate with clamp, nut and bolts.
36Providing and wrapping of barbed wire on 11 KV PCC Poles at a height of 2.75 Mtr. from the ground level as per RESPO Norms.
37Fitting of 11 KV Pilfer proof metering cubical including making proper connections.
38Guarding of 11 KV/33 KV Line with G.I. wire as per RESPO Norms.
39Mounting and fixing of 11 KV CT/PT Unit on double pole including making proper connections.
40Mounting and fixing of 10 KVA transformer on pole including making proper connections.
41Mounting and fixing of 25 KVA transformer on double pole including making proper connections.
42Mounting and fixing of 63 KVA transformer on double pole including making proper connections.
43Mounting and fixing of 100 KVA transformer on double pole including making proper connections.
44Safe installation of 250 KVA transformer on plinth, making H.T./L.T. connections and all other work as per Respo norms.
45Providing G.I. Pipe 6” dia for inserting 11 KV/33 KV XLPE cable for safety of cable on Single/Double Pole by providing and fixing of MS Clamp, Nuts and Bolts.
46Fixing and fitting of single/three phase distribution box on pole for making consumers cable connection complete work.
47Making of Distribution Transformer Plinth with Fencing 250 to 630 KVA as per Respo norms.
48Back carriage of following from work site to Store Centre, Bijnor including loading and unloading at both ends :-
4913 Mtr./11 Mtr./9 Mtr. Long ST Poles.
50ACSR Weasel/Rabbit/Dog Conductor/M.S. Scrap.
51MS Steel Scrap
52CT/PT Unit.
5311KV pilfer proof metering cubical/Old and used Damaged TF 10 to 100 KVA. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56490859
AUTHORITY Government Departments
TENDER VALUE 20 Lakhs
LAST DATE 25-07-2026
Authority
Authority Name Paschimanchal Vidyut Vitran Nigam Limited
Work Description Tender For To Provide The New Connections And Other Works Under Full Deposit Scheme Edd Najibabad Running- 1 Safe Carriage Of The Following Material From Store Centre, Bijnor To Work Site Including Loading And Unloading At Both Ends :- 2 13 Mtr./11 Mtr./9 Mtr./8.5 Mtr. Long Pcc/St Poles. 3 Acsr Weasel/Rabbit/Dog Conductor. 4 11/0.4 10 Kva Transformers. 5 11/0.4 25 Kva Transformers. 6 11/0.4 63 Kva Transformers. 7 11/0.4 100 Kva Transformers. 8 11/0.4 250 Kva Transformers. 9 Lt A.B.C. Cable. 10 11 Kv Xlpe Cable Of Size 3X70 Sq.Mm./ 3X120 Sq.Mm./ 3X180 Sq.Mm. Etc. 11 33 Kv Xlpe Cable Of Size 3X120 Sq.Mm./ 3X300 Sq.Mm. Etc. 12 Line Material Such As Cross-Arms, Pin Insulators, Guarding Angles, Guarding Wire, Disc Insulators And Cable Jointing Kits Etc. 13 Ct/Pt Unit 14 11 Kv Pilfer Proof Metering Cubical. 15 Dismentalling Of 11 Kv/33 Kv Line. 16 Removing Of Acsr Weasel/Rabbit/Dog Conductor From All Phases On Line, Making Bundle And Stacking At A Safe Place. 17 Uprooting Of 13 Mtr./11 Mtr./9 Mtr Long St Poles. 18 33 Kv Ct/Pt 19 11 Kv Ct/Pt 20 For 11 Kv/33 Kv Line, Single Support 13/11/9/8.5 Mtr. Long St/Pcc Poles :- Excavation Of Foundation Pit In Size Of 75X45 Cm. Having Depth Of 1/6Th Of The Full Length Of The Support (Pole), Providing And Laying Of Stone Pad (300X300X75Mm.) In The Bottom Of The Pit. Erection Of Single Pole Support Complete With Fixing Of 11 Kv V-Type Cross-Arms And All Other Accessories By Providing Stone Pad, Holding Clamps, F-Bracket And Nuts & Bolts Etc. As Per Respo Norms. 21 For 11 Kv/33 Kv Line, Double Pole Structure With 13/11/9/8.5 Mtr. Long St/Pcc Poles :- Excavation Of Foundation Pit In Size Of 75X45 Cm. Having Depth Of 1/6Th Of The Full Length Of The Support (Pole). Erection Of Support (Pole) Complete Work By Fixing Of D.P. Clamps And All Other Accessories. The Work Includes Fabrication Work And Fixing Of Cross Bracing Sets, Cutting Holes Complete Work As Per Respo Norms. 22 Grouting Of Poles Single Line Support :- Grouting Of Support In Cc 1:4:6 (Cement, Sand And 40 Mm. Brick Ballast) Grouting Will Be Done In The Block Of Size 45Cm X 45Cm X 1/6Th Of Full Length Of The Support Upto Ground Level As Per Respo Norms. 23 Grouting Of Stay Rods (20X1800Mm.) Including All Works Of Excavation, Cement Concrete In Size Of (0.60X0.60X0.30)M In The Ratio Of 1:4:6 (Cement, Sand And 40 Mm. Brick Ballast) Including Back Filling Of Soil And Proper Ramming Etc. 24 Fixing, Tightening And Nozelling Of Stay Wire With Stay Rod And Stay Insulators With The Pole Of Required Tension By Providing Stay Clamps, Nuts, Bolts Etc. 25 Earthing Of Support With Ms Earth Rod Of (20X2500)Mm. Long Including Excavation Of Pit And Driving Ms Rod 3.0M Apart From Support And 0.5M Below The Ground Level And Connecting Below The Earth Electrodes With The Help Of G.I. Wire 6 Swg Tightening With Nuts And Bolts. 26 Laying, Sagging, Stringing And Binding Of Acsr Weasel/ Dog Conductor With All Other Accessories On Pole As Per Respo Norms. 27 Laying, Sagging, Stringing And Binding Of Abc Conductor With All Other Accessories On Pole As Per Respo Norms. 28 Laying Of 11 Kv Xlpe Cable Of Size 3X70 Sq.Mm./ 3X120 Sq.Mm./ 3X180 Sq.Mm. & 33 Kv Xlpe Cable Of Size 3X120Sq.Mm/3X300 Sq.Mm And Making Connections As Per Respo Norms. 29 Filling And Fixing Of 11 Kv Outdoor/Indoor Type Cable Jointing Kits As Per Respo Norms. 30 Digging Of Cable Trench In Size Of 0.45Mtr.X1.05 Mtr. 31 Laying Of 11 Kv 3X70/120/185 Sq.Mm. Cable & 33 Kv 3X120/300 Sq.Mm. Cable In The Trench. 32 Providing 150 Mm. Sand Cushion Beneath And 150 Mm. Above The Cable. The Cable Shall Be Duly Protected By 1St Class Bricks, Two On Either Side And Third On Top Of The Cable, Laid In The Series One After The Other. 33 Refilling And Ramming Of The Left Out Soil, Closing The Trench And Levelling. Spare Cable Shall Be Left In The Loop Shape At Both Ends, Including Providing Of All Required Material And T&P. 34 Providing And Fixing Of Danger Board With Clamp, Nut And Bolts. 35 Providing And Fixing Of Number Plate With Clamp, Nut And Bolts. 36 Providing And Wrapping Of Barbed Wire On 11 Kv Pcc Poles At A Height Of 2.75 Mtr. From The Ground Level As Per Respo Norms. 37 Fitting Of 11 Kv Pilfer Proof Metering Cubical Including Making Proper Connections. 38 Guarding Of 11 Kv/33 Kv Line With G.I. Wire As Per Respo Norms. 39 Mounting And Fixing Of 11 Kv Ct/Pt Unit On Double Pole Including Making Proper Connections. 40 Mounting And Fixing Of 10 Kva Transformer On Pole Including Making Proper Connections. 41 Mounting And Fixing Of 25 Kva Transformer On Double Pole Including Making Proper Connections. 42 Mounting And Fixing Of 63 Kva Transformer On Double Pole Including Making Proper Connections. 43 Mounting And Fixing Of 100 Kva Transformer On Double Pole Including Making Proper Connections. 44 Safe Installation Of 250 Kva Transformer On Plinth, Making H.T./L.T. Connections And All Other Work As Per Respo Norms. 45 Providing G.I. Pipe 6” Dia For Inserting 11 Kv/33 Kv Xlpe Cable For Safety Of Cable On Single/Double Pole By Providing And Fixing Of Ms Clamp, Nuts And Bolts. 46 Fixing And Fitting Of Single/Three Phase Distribution Box On Pole For Making Consumers Cable Connection Complete Work. 47 Making Of Distribution Transformer Plinth With Fencing 250 To 630 Kva As Per Respo Norms. 48 Back Carriage Of Following From Work Site To Store Centre, Bijnor Including Loading And Unloading At Both Ends :- 49 13 Mtr./11 Mtr./9 Mtr. Long St Poles. 50 Acsr Weasel/Rabbit/Dog Conductor/M.S. Scrap. 51 Ms Steel Scrap
Basic Detail
Tender No 24/2026-27
Bidding Type Tender
Location
City Dhampur
State Uttar Pradesh
Key Dates
Publish Date 15 Jul 2026
Submission Date 25 Jul 2026
Open Date 25 Jul 2026
Finance
Tender Value 20 Lakhs
Tender Fee 3540
EMD 20000
Exemption Available
Document List
19aa375c-507c-4b7d-8548-00005ece8dab.html
BOQ_2194470.xls
TDoc24.pdf
Tendernotice_1 (28).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 25, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 25, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

19aa375c-507c-4b7d-8548-00005ece8dab.html

xls

BOQ_2194470.xls

pdf

TDoc24.pdf

pdf

Tendernotice_1 (28).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender