Public Administrative Department Government Departments Closing in 3 days TDR #56489312

Tender For Construction Of Security Cabin & Allied Work At Entrance Gate In South & North Zone, Dnh

Issued by Government Departments · Dadra and Nagar Haveli, Dadra and Nagar Haveli
Tender Value
1.25 Crore
Estimated cost
Bid Submission
24 Jul 2026
3 days left
EMD
2.52 Lakhs
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Dadra and Nagar Haveli → Dadra and Nagar Haveli
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Construction Of Security Cabin & Allied Work At Entrance Gate In South & North Zone, Dnh

BOQ

Name of Work:- Construction of Security Cabin & Allied Work at Entrance Gate in South & North Zone, DNH
Sl. No. Item Description
1EXCAVATION upto 1.50 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Loose or Soft soil MECHANICALLY but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, cutting vegetation up to 1.5m ht if required and disposing off the excavated stuff upto all lead and lift. Note- All types of soil that can be removed by JCB/ Poclain bucket shall be classified under this item.
2EXCAVATION 1.50 to 3.00 Metre for foundation such as footing, pedestals, walls, drains, columns, ramps, plinth beams, cable trenches in Hard Murrum MECHANICALLY but other than hard rock including shoring, strutting, sorting out and stacking useful material, dewatering where required, and disposing off the excavated stuff upto all lead and lift.
3FILLING with selected & approved available excavated earth (excluding rock) in excavated pits, trenches, in plinth, sub-base for of roads, drains, manhole, sumps, or where required with approved locally available materials including spreading in layers not exceeding 200mm, watering, ramming, compacting mechanically using 2 ton compactor etc, complete. Measurements for net volume of space occupied by filling. If desired by the engineer-in-charge the contractor shall at his own expense carry out modified proctor compaction test to determine the maximum dry density. The criteria for accePTance of filling shall be compacting to 95% modified Proctor density with use of mechanical roller/rammer etc complete as directed and instructed by Engineer-in-charge. Volume of material filled to be measured for payment.
4FILLING with selected & approved Murrum material brought by Contractor from outside client's premises, including Identification of Borrow pits and including Royalty charges & or duties as per requirement of local authority, in foundations, excavated pits, trenches, in plinth, sub-base for of roads, drains, manhole, sumps, or where required with approved locally available materials including spreading in layers not exceeding 200mm, watering, ramming, compacting mechanically using 2 ton compactor etc, complete. Measurements for net volume of space occupied by filling. If desired by the engineer-in-charge the contractor shall at his own expense carry out modified proctor compaction test to determine the maximum dry density. The criteria for accePTance of filling shall be compacting to 95% modified Proctor density with use of mechanical roller/rammer etc complete as directed and instructed by Engineer-in-charge. Volume of material filled to be measured for payment.
5Providing and laying RUBBLE SOLING wherever required in foundation and plinth including hand packing fillings interstices with chips and sand. Watering and compacting to consolidated thickness, etc complete as directed by engineer-in-charge
6Carring out plinth treatment to post construction / existing structure by spraying chemical solution for termite control treatmentincluding labour and material consistment with I.S.I specification.Using Chlordene and Chiorpurfiles 20 EC. As Per 6131_paret-II Consentration Weight one percent is recommended i.e one litre 20 EC chemical emulsion with 19 liter give 1 % concrentration inclusive of one litre chemical emulsion appication at the rate of 5 Litre chemical / Sqm of surface is recommended as per I.S. treated Plinth area of structure to be measured for payment as directed by engineer-in-charge
7Providing and laying PLAIN CEMENT CONCRETE 1:2:4 (1- Cement : 2- Coarse sand : 4- graded stone aggregates 20 mm nominal size) in foundations and superstructure including, machine mixing, leveling compacting, curing and formwork if any, scaffolding, staging etc. complete as directed and instructed by Engineer-in-Charge. Volume of PCC laid to be measured for payment.
8Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering , scaffolding, staging, vibrating, compacting, finishing and curing complete but excluding cost of reinforcement for reinforced concrete work in Foundations, footings, Base of columns and Mass concrete, as directions of Engineer in charge Complete.
9Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering , scaffolding, staging, vibrating, compacting, finishing and curing complete but excluding cost of reinforcement for reinforced concrete work in Columns, Pillars posts and struts etc complete as directed by Engineer-incharge.
10Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering , scaffolding, staging, vibrating, compacting, finishing and curing complete but excluding cost of reinforcement for reinforced concrete work in Lintels, Beams, Girders and Cantilever etc complete as directed by Engineer-incharge.
11Providing material and labour for laying machine mixed/machine batched/RMC controlled cement concrete M.250 using graded black trap stone aggregates of maximum 20mm nominal (down graded) size including fine aggregate confirming to IS 383 with minimum cement content as per IS456 (without flyash) for durability shall be followed as per approved design mix & latest IS456 for reinforced cement conrete work for all elements,all floors,all heights/depths, any lead and lift including cost of formwork with sheathing steel or form finish ply shuttering, scaffolding, staging, vibrating, compacting, finishing and curing complete but excluding cost of reinforcement for reinforced concrete work in Slabs, landing, shelves and Cantilever etc complete as directed by engineer-incharge.
12Providing, laying and fixing in position REINFORCEMENT High yield deformed bars/TMT/ FE500/FE500D/FE550 for R.C.C. works at all levels including cutting, bending and binding with 16 gauge M.S. annealed wire, providing cover blocks of C.M. 1:2 Embedded with binding wire etc. complete. The reinforcement detailing to IS 456 or, if specified by engineer, shall conform to IS: 13920 (Ductile detailing of R. C. Structures), bars as per IS 1786 the rate shall be inclusive of executing such detailing. Laps to be measured shall be as shown in drawing and for reinforcement length longer than available in market. Chairs, pins and laps other than that specified shall not on be measured and paid for. No extra to be paid for height, rate remains same at all levels, complete as per drawings, specification, direction of engineer-incharge. Make: TATA, SAIL, JSW or as approved by chief engineer Complete.
13Brick work using common burnt clay building bricks including scaffolding, raking of joints, curing using first class bricks having min. comp. Strength 35 kg/cm2 of approved manufacturer in foundation and plinth in Cement Mortar 1:5 (1- Cement : 5 -fine sand) (B) CONVENTIONALAll bricks and shall be soaked in water for at least 24 hours before use. bricks used for masonry work shall be as available locally, but approved before start of work. volume of masonry to be measured for payment.
14Brick work using common burnt clay building bricks including scaffolding, raking of joints, curing using first class bricks having min. comp. Strength 35 kg/cm2 of approved manufacturer in in superstructure above plinth level in Cement Mortar 1:5 (1- Cement : 5 -fine sand) (B) CONVENTIONALAll bricks and shall be soaked in water for at least 24 hours before use. bricks used for masonry work shall be as available locally, but approved before start of work. volume of masonry to be measured for payment.
15Providing and laying 10mm thick in single coat CEMENT PLASTER in (i)Cement mortar 1:3 (1-cement:3-sand) at all height/all floors to internal surfaces of all elements, walls, R.C.C. work, Ceiling,[backing coat at places where glazed or ceramic tiles are to be fixed etc]. including hacking of concrete surfaces, racking of joints, scaffolding, curing etc. complete. Final finished surface shall be little rough , so as it has proper bonding to paint putty.The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete.
16Providing and laying 20mm thick mala CEMENT PLASTER of required grain finishing upto all height/all floors including grooves, pattas etc. in two coats having the the base coat of not less than 12 mm thickness in CM 1:3 (1-cement : 3-sand) & finished coat 8 mm thk, in CM 1:1 (1-cement : 1-sand) to external surfaces of concrete & masonry including hacking of concrete surfaces, racking of joints, scaffolding, curing etc. complete. Rate shall include addition of “Impermo” water proofing compound or equivalent, providing, adding & mixing of fine fibrillated 100% virgin polypropylene fibers in cement mortar to form homogeneous mixture @125 gms per a bag of cement in both the coats of plaster, 12mm long fibers shall be used in first coat & 6mm long fibers shall be used in second finished coat. providing drip mould 40mm wide and 12mm thick in cement mortar 1:3 on soffit of chajjas, canopies, gutters. The surfaces to be plastered to be hacked immediately on de-shuttering. The Brick/ RCC surface to be plastered to be cured sufficiently before start of plaster. Initial bare surface area to be Plastered shall be measured for payment unless noted otherwise, etc as directions of Engineer in charge Complete.
17Providing material and labor for applying Two coats of gypsum 2 to 3mm thk. including providing grooves at all the edges of windows/Doors with neat finish on new/existing wall surface to give an even shade including thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth.make the surface uniform and levelled and must be without any undulation as directed by engineer in charge complete.Make: Diamond gypsum or as approved by engineer-in-charge.
18\\"Providing material & labour for Internal Wall painting (two coats) with Premium Emulsion of approved brand and manufacture including primer coat on undecorated wall surface to give an even shade including throughly brushing the surface free from mortar droppings and other foreign matter and sand papered smooth. as directed by engineer in charge complete. emulsion that must offer protection against different varieties of bacteria and fungus.The product shall be independently tested and approved for properties like resistance to bacterial and fungal species, crack tolerance and flame spread resistance.The coating shall contribute to satisfying the following credit(s): Indoor Environmental Quality (IEQ) under LEED® 2009 Environmental Quality (EQ) and Materials and Resources (MR) under LEED® v4This product shall have a VOC limit not more than 24 g/lit. The product can be like Asian apcolite emulsion or Jotun Paints or equivalents as approved by chief engineer.Two Coats of above paint should be applied using conventional Roller / Airless spray at the site after application and drying of applied Putty-Primer. For measurement of painting items the area painted shall be considered without any multiplication factor for different kinds of surfaces painted. Rate shall be quoted accordingly. All painting items final finish shall be as per manufacturer'sspecification as per accePTance of Engineer in charge /Architect. No extra payment shall be made for extra/over coat if required.The rate shall be inclusive of providing bamboo scaffoldingMake: Jotun,Asian Paints, Berger Paints, Dulux Paints or as approved by chief engineer.\\"
19Providing material and labour for fixing ISI marked Single Shutter flush door, shutters conforming to IS : 2202 (Part I) decorative type, core of plywood board construction with including providing ALUMINIUM SECTION frame for door of size 15 cm x 7 cm, 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws, with Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt / suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS :2046 Type S, including cost of adhesive of approved quality 1.0mm Thick on both face, with Providing and fixing S.S. tower bolts (barrel type) with necessary screws etc 200mm long x10mm dia, with Providing and fixing S.S. Door Aldrop with necessary screws etc. 300mm long x16mm dia, Providing and fixing S.S. Door Aldrop with necessary screws etc 250mm long x16mm dia, with Providing and fixing S.S. Pipe Handle for door 30cm size on both side of Door shutter, with Providing and fixing S.S hanging type floor door stopper with necessary screws, etc. complete as directed by Engineer in charge. All S.S Shall be ASIS 304 Grade. Plywood Make:- Century Ply Laminates, Greenply Industries Limited, SRG Ply & Boards or equivalent.
20ALUMINIUM WORKS -Providing material and labour for fixing in position frames, shutter for any type of aluminium work for any type of door, window, partition, made out of any type of aluminium sections of approved make having minimum 50 micron pure polyester powder coating of approved shade, texture & colour of approved make for all floors, all levels, all heights, all shapes, all sizes including cutting, bending, crimping, fabricating in best workmanship manner etc as per the drawing, specification and as directed by Architect or Engineer-in-Charge. Contractor shall prepare shop drawing based on concept drawing and get approved from the consultants before procurement of material. All loose material shall be approved. Mockup of one/two window shall be executed as per approved shop drawing with all hardware. Work shall carried out as per the approved shop drawings, approved mock-up and approved sample. Actual weight of installed Aluminium sections (for using fabrication without considering any wastage) shall only be measured and shall be considered for the payment. Glazing shall be paid as seperate item. Contractor shall provide guarantee for stability, water tightness etc for 12 months after defects liability period. Rate shall be inclusive of providing aluminium sections, cutting, fabrication, errection and fixing to the best workmanship manner, including 1) Sheet metal screws and casted solid aluminum corner cleats fixed with external byttins with a spring for rapid and secure joint assembly for casement and sliding shutter and frame; 2) Glazing clips for receiving infill panel; 3) Best quality wool pile where ever shutter touches the frame and compatible microwave cured EPDM rubber; 4) Dash Anchor fasteners of HILTI HRDUGT or equivalent for fixing the frame assembly to the RCC or masonry surfaces. Minimum 1 anchor fastener shall be used for every 600 mm length of section for stability of frame. 5) 10mm GI tie rod for connecting vertical stile at top and bottom for aluminum door shutter and 4mm thick solid aluminium corner cleat of full thickness of section for connecting style and horizontal rails; 6) providing and fixing packing (rough ground) in full periphery/ at every 600mm c/c with average 6 mm thick PVC spacer/ compact sheet of width (equal to section width less 30mm for backer rod and sealant); 7) Filling the gap between wall and frame on both sides (outside and inside) with polyethylene baker rod of avg. 10 mm thickness of approved make and color and then sealing the remaining gap with neutral grade G/M (Glazed & Metal) weather silicon sealant of approved make and color. 8) Termite treated seasoned teak wood as infill material to installe hardware in door shutter and frame as and when required, etc as per directions of Engineer in charge Complete. Make:- Jindal or equivalent as approved by chief engineer
21Providing & Fixing Louvers and Fins (made out of Aluminium Section)Providing, fixing, designing aluminium fixed louver of any type of louver section of approved make having minimum 50 micron polyster powder coating on all the surfaces of approved shade, texture & make as per manufacturer's specifications. Contractor shall submit the shop drawing for louver/ fins based on concept design/ drawing and as per elevation. Aluminium louver section shall be fixed on aluminium framing/ carrier/ panel/ GI clip and necessary sub structure with required fastners, hardware as per approved shop drawing etc complete for all floor, all height including scaffolding as directed by engineer in charge. Louver, framing and sub structure shall be in proper line, level and plumb. Necessary MS work shall be paid in relevant tender item.
22Providing material and labour for fixing 6mm thick Clear Normal Glass as per approved sample of any size, any shape and specified thickness in frame and shutter work with necessary cutting of glass as per drawing & specifications including providing and fixing EPDM quality rubber/ silicon sealant/ structural sealant and 3M tape on the periphery of the glass as per the required thickness etc. complete at all floors/ all levels/ all heights as per the directions of Engineer in charge. Actual installed quantity shall be measured and paid.
23Providing material and labor for fixing pre-cast concrete finish kerbs including Transition , Dropper & offlet kerbs, Radius kerbs, angle & Quadrant Kerbs, concrete block 600mm length, 300mm height and 150mm thick of M250 grade concrete as per approved design and including excavation for fixing in proper line and level,filling the joint with C:M 1:3 (1cement:3fine sand) etc complete.
24Providing material & labour for fixing Sand blasted pre-cast concrete High Strength High Finish (HSF) paver block 80mm thick as per design of any shape/any size with percentage of water absorption not more than 6%, compresive strength not less than 350 kg/Sqm. Tensile splitting strength (as per EN 1338) not less than 3.6 Mpa any colours as per approved design including 75mm Sand bedding layer for levelling and filling the joint with sand in proper line and level. The paver block should be strong enough to take heavy traffic load. The sand bed should make up for all the undulations and give a leveled surface. A mechanical compactor shall be used for compacting the sand base. All this should be in line with the manufacturer's specifications and the Engineer's directions. The final surface should be swept clean of all dust and sand to get uniform and smooth riding surface. Area of Block laid to be measured for payment etc complete. Make:- Vyara, Supertiles or equivalent as approved by chief engineer
25Providing material & labor for laying 24\\" x 24\\" Vitrified 8 to10 mm thick tile flooring over 20 mm (average) base of cement mortar 1:4 ( 1 cement: 4 coarse sand) on new surface and spacer of required size to be provide while fixing the tile. Tiles joint grooves to be filled with 8mm wide epoxy of approved shade/colour including finished with flush pointing & cleaning the surface etc. complete. Make: Nitco, Simpolo, Kajaria, johnson, Rak or as approved by engineer-in-charge complete.
26Providing material & labour for laying Vitrified tiles 8 to 10 mm thick , in required size for Skirting upto 100mm on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry including finised with flush pointing & cleaning the surface etc. complete. For SkirtingMake: Nitco, Simpolo, Kajaria,johnson, Rak oras approved by engineer-in-charge complete.
27Providing material & labor for laying 24\\" x 24\\" Anti-skid Vitrified 8 to 10 mm thick tile flooring over 20 mm (average) base of cement mortar 1:4 ( 1 cement: 4 coarse sand) on new surface and spacer of required size to be provide while fixing the tile. Tiles joint grooves to be filled with 8mm wide epoxy of approved shade/colour including finished with flush pointing & cleaning the surface etc. complete. Make: Nitco, Simpolo, Kajaria, johnson, Rak or as approved by engineer-in-charge complete.
28Providing material & labour for Fixing 15 mm thick Full body heavy duty tiles, premoulded and prepolished machine cut for platforms, vanity counters, door window, sills, jambs, soffits facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding on all exposed edges and polishing to edge to give high gloss finish etc. complete. at all levels. Make: Somany Duragres granit series or equivalent as approved by engineeri-in-charge or Architect
29Providing material & labour for laying Vitrified tiles 8 to 10 mm thick 300x450mm or in any required size for dado on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and jointed with white cement slurry including finised with flush pointing & cleaning the surface etc. complete or as directed by engineer-in-charge. For DadoMake: Nitco, Simpolo, Kajaria,johnson, Rak or equivelant as approved by engineer in charge
30Providing and laying Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge.
31Providing material & labour for Granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade. FOR URINAL PARTITIONS
32Providing material and labour for making Black Granite stone Counter Wash Basin of 0.60mt wide with vertical & Horizontal Support of granite stone and having bottom slab of 25mm to 30mm thick kadappa stone fixing with cement motar 1:4 (1 Cement :4fine sand) and neat cement slurry as per requirement including cutting the granite stone & providing 7 fixing oval shape wash basin of 22''x16\\" size white colour in line & level. All exposed Edges of granite should be moulded including all accessories like pillar cock (Swan neck type), fexible inlet pipe 15mm dia, C.P. brass waste coupling 32mm, PVC Waste pipe 32mm etc. as directed by Enginner on Charge.
33Providing material & labour for laying upto 18mm to 20mm thick red sandstone for cladding work on with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical bond of stone with base surface including all the necessary fitting and fixtures requird to install cladding, all fitting and fixtures shall be of Stainless steel 304 grade. cost should also include Supply and providing V-Groove, L-Groove, and U-Groove of width 6mm to 8mm groove cutting in required surfaces in stone using precision tools as per detailed drawing and design. The work includes marking grooving to specified profile and depth cleaning of grooves aligning the grooves for desired aesthetics and pattern, ensuring burr-free and smooth finish.including scaffolding, Also including Labour charges for carefully carving and finishing Full Round moulding in stone (granite/sandstone/marble or other approved stone) for strengthening and decorative edge purposes. Work includes marking on the stone surface, manual/mechanical chiseling and rounding of the exposed edges to full round profile (typically semicircular or custom radius as per drawing) using skilled craftsmanship to achieve smooth, uniform curves. The finished surface shall be dressed, rubbed, and polished (if required) to match adjoining surfaces. Includes edge alignment, corner junction treatment, finishing, cleaning, including scaffolding, Also including Labour charges for providing and finishing Half Round moulding on exposed edges or surfaces of natural stone (such as granite, marble, sandstone, or other approved stone), for strengthening and decorative purposes, as per drawing and design.Work includes proper marking, cutting, chiseling, and shaping of the stone to form a uniform half-round profile (typically semicircular radius, as specified), ensuring smooth finish and structural integrity.Includes dressing, rubbing, and polishing of moulded surfaces (if required), proper alignment, junction finishing, edge protection, and cleaning of work area. including scaffolding, Also including Labour charges for providing Galta moulding traditional concave/curved profile in stone work granite, marble, sandstone, or approved type as per architectural drawing and specifications.The work includes accurate marking, manual or machine chiseling, and profiling to achieve the Galta (concave) profile, ensuring symmetry and smooth curvature throughout the moulded length.The moulding shall be uniform in shape and depth, and the surface shall be neatly dressed, rubbed, and polished (if required) to match the adjacent stone finish.including scaffolding, Also Supply and providing Akemi Stone Cleaner or equivalent approved brand, specifically formulated for cleaning natural and artificial stone surfaces such as granite, marble, sandstone, limestone, and other similar materials.The cleaner shall be suitable for removing cement residues, dust, grease, light oil stains, and general construction grime without damaging the surface or altering the natural finish of the stone.including scaffolding, Also Supply and providing Akemi Stone Sealer or equivalent approved brand specially formulated for the protection of natural and artificial stones such as granite, marble, limestone, sandstone, and engineered stones, as per manufacturer specifications.The stone sealer shall be of high-quality, penetrating impregnating or surface-forming type as specified designed to protect against water absorption oil stains, dirt, and other contaminants, while maintaining the natural appearance, color, and breathability of the stone.including scaffolding etc. complete or as directed by engineer-in-charge. Size of Stone as per approved achitectural drawing Size 450x900mm or as directed by engineer-in-charge
34Providing material & labour for laying upto 18mm to 20mm thick red sandstone blasted for cladding work with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical bond of stone with base surface including all the necessary fitting and fixtures requird to install cladding, all fitting and fixtures shall be of Stainless steel 304 grade. cost should also include Supply and providing V-Groove, L-Groove, and U-Groove of width 6mm to 8mm groove cutting in required surfaces in stone using precision tools as per detailed drawing and design. The work includes marking grooving to specified profile and depth cleaning of grooves aligning the grooves for desired aesthetics and pattern, ensuring burr-free and smooth finish.including scaffolding, Also including Labour charges for carefully carving and finishing Full Round moulding in stone (granite/sandstone/marble or other approved stone) for strengthening and decorative edge purposes. Work includes marking on the stone surface, manual/mechanical chiseling and rounding of the exposed edges to full round profile (typically semicircular or custom radius as per drawing) using skilled craftsmanship to achieve smooth, uniform curves. The finished surface shall be dressed, rubbed, and polished (if required) to match adjoining surfaces. Includes edge alignment, corner junction treatment, finishing, cleaning, including scaffolding, Also including Labour charges for providing and finishing Half Round moulding on exposed edges or surfaces of natural stone (such as granite, marble, sandstone, or other approved stone), for strengthening and decorative purposes, as per drawing and design.Work includes proper marking, cutting, chiseling, and shaping of the stone to form a uniform half-round profile (typically semicircular radius, as specified), ensuring smooth finish and structural integrity.Includes dressing, rubbing, and polishing of moulded surfaces (if required), proper alignment, junction finishing, edge protection, and cleaning of work area. including scaffolding, Also including Labour charges for providing Galta moulding traditional concave/curved profile in stone work granite, marble, sandstone, or approved type as per architectural drawing and specifications.The work includes accurate marking, manual or machine chiseling, and profiling to achieve the Galta (concave) profile, ensuring symmetry and smooth curvature throughout the moulded length.The moulding shall be uniform in shape and depth, and the surface shall be neatly dressed, rubbed, and polished (if required) to match the adjacent stone finish.including scaffolding, Also Supply and providing Akemi Stone Cleaner or equivalent approved brand, specifically formulated for cleaning natural and artificial stone surfaces such as granite, marble, sandstone, limestone, and other similar materials.The cleaner shall be suitable for removing cement residues, dust, grease, light oil stains, and general construction grime without damaging the surface or altering the natural finish of the stone.including scaffolding, Also Supply and providing Akemi Stone Sealer or equivalent approved brand specially formulated for the protection of natural and artificial stones such as granite, marble, limestone, sandstone, and engineered stones, as per manufacturer specifications.The stone sealer shall be of high-quality, penetrating impregnating or surface-forming type as specified designed to protect against water absorption oil stains, dirt, and other contaminants, while maintaining the natural appearance, color, and breathability of the stone.including scaffolding etc. complete or as directed by engineer-in-charge. Size of Stone as per approved achitectural drawing Size 450x900mm or as directed by engineer-in-charge
35Providing material & labour for laying upto 18mm TO 20mm thick yellow sandstone for cladding work with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical bond of stone with base surface including all the necessary fitting and fixtures requird to install cladding, all fitting and fixtures shall be of Stainless steel 304 grade. cost should also include Supply and providing V-Groove, L-Groove, and U-Groove of width 6mm to 8mm groove cutting in required surfaces in stone using precision tools as per detailed drawing and design. The work includes marking grooving to specified profile and depth cleaning of grooves aligning the grooves for desired aesthetics and pattern, ensuring burr-free and smooth finish.including scaffolding, Also including Labour charges for carefully carving and finishing Full Round moulding in stone (granite/sandstone/marble or other approved stone) for strengthening and decorative edge purposes. Work includes marking on the stone surface, manual/mechanical chiseling and rounding of the exposed edges to full round profile (typically semicircular or custom radius as per drawing) using skilled craftsmanship to achieve smooth, uniform curves. The finished surface shall be dressed, rubbed, and polished (if required) to match adjoining surfaces. Includes edge alignment, corner junction treatment, finishing, cleaning, including scaffolding, Also including Labour charges for providing and finishing Half Round moulding on exposed edges or surfaces of natural stone (such as granite, marble, sandstone, or other approved stone), for strengthening and decorative purposes, as per drawing and design.Work includes proper marking, cutting, chiseling, and shaping of the stone to form a uniform half-round profile (typically semicircular radius, as specified), ensuring smooth finish and structural integrity.Includes dressing, rubbing, and polishing of moulded surfaces (if required), proper alignment, junction finishing, edge protection, and cleaning of work area. including scaffolding, Also including Labour charges for providing Galta moulding traditional concave/curved profile in stone work granite, marble, sandstone, or approved type as per architectural drawing and specifications.The work includes accurate marking, manual or machine chiseling, and profiling to achieve the Galta (concave) profile, ensuring symmetry and smooth curvature throughout the moulded length.The moulding shall be uniform in shape and depth, and the surface shall be neatly dressed, rubbed, and polished (if required) to match the adjacent stone finish.including scaffolding, Also Supply and providing Akemi Stone Cleaner or equivalent approved brand, specifically formulated for cleaning natural and artificial stone surfaces such as granite, marble, sandstone, limestone, and other similar materials.The cleaner shall be suitable for removing cement residues, dust, grease, light oil stains, and general construction grime without damaging the surface or altering the natural finish of the stone.including scaffolding, Also Supply and providing Akemi Stone Sealer or equivalent approved brand specially formulated for the protection of natural and artificial stones such as granite, marble, limestone, sandstone, and engineered stones, as per manufacturer specifications.The stone sealer shall be of high-quality, penetrating impregnating or surface-forming type as specified designed to protect against water absorption oil stains, dirt, and other contaminants, while maintaining the natural appearance, color, and breathability of the stone.including scaffolding etc. complete or as directed by engineer-in-charge. Size of Stone as per approved achitectural drawing Size 450x900mm or as directed by engineer-in-charge
36Providing material & labour for laying upto 18mm TO 20mm thick yellow blasted sandstone for cladding work with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical bond of stone with base surface including all the necessary fitting and fixtures requird to install cladding, all fitting and fixtures shall be of Stainless steel 304 grade. cost should also include Supply and providing V-Groove, L-Groove, and U-Groove of width 6mm to 8mm groove cutting in required surfaces in stone using precision tools as per detailed drawing and design. The work includes marking grooving to specified profile and depth cleaning of grooves aligning the grooves for desired aesthetics and pattern, ensuring burr-free and smooth finish.including scaffolding, Also including Labour charges for carefully carving and finishing Full Round moulding in stone (granite/sandstone/marble or other approved stone) for strengthening and decorative edge purposes. Work includes marking on the stone surface, manual/mechanical chiseling and rounding of the exposed edges to full round profile (typically semicircular or custom radius as per drawing) using skilled craftsmanship to achieve smooth, uniform curves. The finished surface shall be dressed, rubbed, and polished (if required) to match adjoining surfaces. Includes edge alignment, corner junction treatment, finishing, cleaning, including scaffolding, Also including Labour charges for providing and finishing Half Round moulding on exposed edges or surfaces of natural stone (such as granite, marble, sandstone, or other approved stone), for strengthening and decorative purposes, as per drawing and design.Work includes proper marking, cutting, chiseling, and shaping of the stone to form a uniform half-round profile (typically semicircular radius, as specified), ensuring smooth finish and structural integrity.Includes dressing, rubbing, and polishing of moulded surfaces (if required), proper alignment, junction finishing, edge protection, and cleaning of work area. including scaffolding, Also including Labour charges for providing Galta moulding traditional concave/curved profile in stone work granite, marble, sandstone, or approved type as per architectural drawing and specifications.The work includes accurate marking, manual or machine chiseling, and profiling to achieve the Galta (concave) profile, ensuring symmetry and smooth curvature throughout the moulded length.The moulding shall be uniform in shape and depth, and the surface shall be neatly dressed, rubbed, and polished (if required) to match the adjacent stone finish.including scaffolding, Also Supply and providing Akemi Stone Cleaner or equivalent approved brand, specifically formulated for cleaning natural and artificial stone surfaces such as granite, marble, sandstone, limestone, and other similar materials.The cleaner shall be suitable for removing cement residues, dust, grease, light oil stains, and general construction grime without damaging the surface or altering the natural finish of the stone.including scaffolding, Also Supply and providing Akemi Stone Sealer or equivalent approved brand specially formulated for the protection of natural and artificial stones such as granite, marble, limestone, sandstone, and engineered stones, as per manufacturer specifications.The stone sealer shall be of high-quality, penetrating impregnating or surface-forming type as specified designed to protect against water absorption oil stains, dirt, and other contaminants, while maintaining the natural appearance, color, and breathability of the stone.including scaffolding etc. complete or as directed by engineer-in-charge. Size of Stone as per approved achitectural drawing Size 450x900mm or as directed by engineer-in-charge
37Providing and fixing sandstone cornice on the borders for Architectural elevation work of entrance gate/security cabin/etc in approved size, pattern, design, thickness 20 to 25 mm and color as per detailed drawing having height of 500 to 800mm with 8 to 12 steps having depth varying 100 to 500mm of EACH step, bonding with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical/Horizantal bond of stone with base surface including all the necessary fitting and fixtures requird to install cornice, all fitting and fixtures shall be of Stainless steel of 304 grade complete as per the approved architectural design or as directed by engineer-in-charge. cost should also include Supply and providing V-Groove, L-Groove, and U-Groove of width 6mm to 8mm groove cutting in required surfaces in stone using precision tools as per detailed drawing and design. The work includes marking grooving to specified profile and depth cleaning of grooves aligning the grooves for desired aesthetics and pattern, ensuring burr-free and smooth finish including scaffolding, Also including Labour charges for carefully carving and finishing Full Round moulding in stone (granite/sandstone/marble or other approved stone) for strengthening and decorative edge purposes. Work includes marking on the stone surface, manual/mechanical chiseling and rounding of the exposed edges to full round profile (typically semicircular or custom radius as per drawing) using skilled craftsmanship to achieve smooth, uniform curves. The finished surface shall be dressed, rubbed, and polished (if required) to match adjoining surfaces. Includes edge alignment, corner junction treatment, finishing, cleaning, including scaffolding, Also including Labour charges for providing and finishing Half Round moulding on exposed edges or surfaces of natural stone (such as granite, marble, sandstone, or other approved stone), for strengthening and decorative purposes, as per drawing and design.Work includes proper marking, cutting, chiseling, and shaping of the stone to form a uniform half-round profile (typically semicircular radius, as specified), ensuring smooth finish and structural integrity. Includes dressing, rubbing, and polishing of moulded surfaces (if required), proper alignment, junction finishing, edge protection, and cleaning of work area. including scaffolding, Also including Labour charges for providing Galta moulding traditional concave/curved profile in stone work granite, marble, sandstone, or approved type as per architectural drawing and specifications. The work includes accurate marking, manual or machine chiseling, and profiling to achieve the Galta (concave) profile, ensuring symmetry and smooth curvature throughout the moulded length. The moulding shall be uniform in shape and depth, and the surface shall be neatly dressed, rubbed, and polished (if required) to match the adjacent stone finish including scaffolding, Also Supply and providing Akemi Stone Cleaner or equivalent approved brand, specifically formulated for cleaning natural and artificial stone surfaces such as granite, marble, sandstone, limestone, and other similar materials. The cleaner shall be suitable for removing cement residues, dust, grease, light oil stains, and general construction grime without damaging the surface or altering the natural finish of the stone including scaffolding, Also Supply and providing Akemi Stone Sealer or equivalent approved brand specially formulated for the protection of natural and artificial stones such as granite, marble, limestone, sandstone, and engineered stones, as per manufacturer specifications. The stone sealer shall be of high-quality, penetrating impregnating or surface-forming type as specified designed to protect against water absorption oil stains, dirt, and other contaminants, while maintaining the natural appearance, color, and breathability of the stone including scaffolding etc Measurement shall be done on running meter basis only. Individual steps of cornice shall not be counted for measurement; Overall cornice height will be considered as single height.
38Provide sandstone decorative jaali of upto 25mm thick in CNC cutting including material and labour as per architectural drawing designs and dimensions with precise cutting, edge finishing, handling,, quality control, installation at any height/floor/level with required scaffolding & support structure, bonding with Chemical additives LATICRETE® 325 Shear Wall Adhesive or equivalent for strengthening the vertical/Horizantal bond of stone with base surface including all the necessary fitting and fixtures requird to install cornice, all fitting and fixtures shall be of Stainless steel of 304 grade complete as per the approved architectural design or as directed complete as per direction of Architect or Engineer-in-charge
39Providing material and labour for applying Chemical Waterproof Coating PU One Coat epoxy primer and Three coat polyrethane coating including preparation of surface as required for terraces and Toilets. as approved by the Chief engineer-incharge with a guarantee of 10 years. Complete. Make:- MYK Arment, Pidilite, Sika or equivelant.
40Providing material, Labour and equipments for Providing and laying integral Cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc. consisting of following operations : a) Applying a slurry coat of neat cement using 2.75 kg/SQM of cement admixed with water proofing compound conforming to IS 2645 and approved by Engineer in charge over the RCC Slab including adjoining walls uPTo 300 mm height including cleaning the surface before treatment. b) Laying brick bats with mortar using broken bricks / brick bats 25mm to 115mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge over 20mm thick layer of cement mortar of mix 1:5 ( 1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge to required slope and treating similarly the adjoining walls uPTo 300 mm height including rounding of junction of walls and slabs. c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg / SQM of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge.d) Finishing the surface with 20mm thick jointless cement mortar of mix 1:4 ( 1 cement : 4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer in charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300 x 300 mm square 3 mm deep.e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer in charge : Including Khurra & Gola work with average thickness of 120mm and minimum thickness at Khurra as 65 mm etc. complete as directed by Chief Engineer in charge.
41Providing material and labor for GARDEN SOIL:- Supplying on site garden soil well sieved 90% to pass through I.S. sieve of 10mm size free from stones rubbish like dried grass roots and other such materials. The soil should be ftesh from quarry. The colour of the soil generally be red. The soil will be measured by measuring box.(Farma) (Item includes Royalty charges,, Transporting, Ioading unloading etc.) lead charges for 30 k.m. is considered.
42Providing material and labor for LAWN :- Supplying and planting reuired variety of lawn grass as directed and maintaining till well established by watering, weeding clipping, rolling etc. complete.
43HENNA PLANTATION :- Excavting the ground to required depth of 30 cms, removing and coveying unwanted stuff to a required depth as directed. Filling fresh garden soil and manure in excavted area 3:1 poroporation to a height of 30 cms. Mixing garden soil and manure thoroughly well developed shurbs plants, 0.50 RMT height, 0.45RMTapart as directed and maintaining till well eastabilished by watering, weeding, stirring, replacing casualtiies etc. complete
44Providing material and labor for SHRUBS: Digging planting pits of size approx. 0.45m x 0.45m x 0.45m; removal and disposal of unwanted material as directed. Filling pit bottom 0.15m with approved excavated material. Backfilling remaining pit with fresh garden soil mixed with well-rotted manure/compost in 3:1 ratio, mixed thoroughly. Leveling and watering pit prior to planting. Supply and planting of healthy shrub saplings (1-2 years old), min. height 0.3-0.6m as per approved species and specs. Staking/support if required. Maintenance including watering, weeding, stirring soil, replacing dead plants until well established. Complete as per specifications and drawings.
45Providing and fixing in position cowel went to pipes.(B) 75mm dia.
46Providing and fixing wash down water closet European type WC pan (Wall Hung) like JAQUAR CNS-WHT-961SPP- SIZE 365x545x360MM and P trap distance 23.5 cms with integral P trap including jointing the trap with soil pipe in cement mortar 1:1 (1 cement : 1 find sand) including providing and fixing of 1) Health Faucet hand shower heavy duty with SS braided hose 1.2 MT long pipe to water closet - JAQUAR ALD-CHR-573 with Single Piece Slim Concealed Cistern Body with Installations Kit & “S-Type” drain pipe connection set for Wall Hung WC (without Flush Control Plate) - JCS-WHT-2400S with Control Plate Opal - JCP-CHR-152415,Toilet roll holder -Jaquar -ACN -1151N etc,complete Make:-Jaquar/Cera/Parryware/Hindware or Equivalent as approved by architect
47Providing and fixing plastic seat and cover for wash down water closer with C.P. brass hinges and rubber buffers. (B) Black plastic seal and cover.
48Providing and fixing toilet paper holder.(A) C.P. Brass
49Providing and fixing 12.5 LTRs low level flushing cistern with a pair, of C.I. or Mild brackets, complete with fittings such as lead valve less syphon, 15mm nom.nal size brass ball valve with polythene float, C.P brass handle unions and couplings for connections, with inlet, outlet and overflow pipes, 40mm dia. porcelain enamelled flush bend including cutting holes in walls and making good the same connecting the flush bend with cistern and closet (overflow pipe to be measured and paid for separately)(A) Vitreous China (I) In white colour
50Providing and fixing washbasin with single hole for pillar tap with C.I. or M.S. brackets painted white including sutting holes and making good the same but excluding fittings.(A) Vitreous China:(ii) Flat Back washbasin 550 mm x v 400mm size. (i) In white colour.of approved make Jaquar, cera, Hindware or its equivalent as approved by architect
51Providing and fixing C.P. brass waste for washbasin or sink. (B) 40mm dia.
52Providing and fixing M.I. fisher union for washbasin or sink. (B) 40mm dia.
53Providing and fixing 600mm x 450mm bevelled edge mirrror of superior glass mounted on 6mm thick A.C. sheet or plywood sheet and fixing to wooden pluge with C.P. brass screws and washers.
54Providing and fixing chromium plated, bottle trap with necessary couplings of approved quality for wash basin.
55Providing and fixing screw down bib taps of following size.(B) Brass chromium plated screws down Bib Tap. (i) 15mm dia.
56Providing and fixing Gun metal check or non-return fullway wheel valve.(D) 32mm dia.
57Providing and fixing Urinal or approved quality including conecting the Urinal with waste pipe , tap etc. complete.(A) White earthenware flat back or corner type size 430mm x 260mm x 350mm. Make:Jaquar/Cera/Parryware/Hindware
58Providing and fixing chromium plated brass half trun flush cock of approved quality including fixing in pipe line etc. complete.(i) 20mm dia.
59Providing and fixing ball cock of approved. quality asdirected.(B) Abonite (ii) 50mm dia.
60Providing laying and jointing in true line and level 15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
61Providing laying and jointing in true line and level 25mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water including fittings as approved by Engineer In Charge. Pipe shall be fixed on the wall with the help of clamp at every two metre C/C or shall be concealed as directed including necessary fittings etc. including testing of pipe and joints and fixing the same with adhesive solvent, including cost of all materials.
62Providing, laying and jointing in true line and level 110 diametre U.P.V.C (Type B) conforming to IS 13592-1992 with one end plain and other end socketed with rubber ring, & fittings conforming to ISI 14735-1999 of approved make for drainage system pipe line, pipe shall be jointed with EACH other with rubber lubricant, pipe shall be fixed on wall using of PVC clamp of the size 110 mm diametre x 149 mm length x 145 mm heigh at every 2000 mm center to center or shall be concealed in walls as directed including necessary fittings such as bends, shoes etc. including testing of pipes and joints and jointed with adhesive solvent cement including cost of all materials.
63Providing and fixing PVC SWR Nahni trap IS 14735 for drain - 100 mm diameter with jali of the following nominal diameter of self cleansing design with C.I scread down or hinged grating including the cost of cutting and making good the walls.
64Providing erecting and fixing double coated ISI water tank of required capacity EACH with all necessary fittings and connection etc. complete on terrace
65Providing and fixing S.W. gully trap with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300mm x 300mm size (inside) with standard weight.(i) Square mouth traps. (A) 100mm x 100mm size P type.
66Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1- cement :2-coarse sand : 4-graded stone aggregate 20mm nominal size) foundation concrete 1:3:6 mix (1-cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside plastering 15mm thick with Cement Mortar 1:3 (1- Cement : 3-coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 Cement :2-Coarse sand :4-stone aggregate 20mm nominal size) finished smooth complete including curing and festing (i) Inside size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size 560mm diameter total weight of cover and frame to be not less than 128 kgs. (Wt. of cover 64 KG and Wt. of frame 64 KG)(A) With 230mm thick walls of brick msonry using brick having crushing strength not less than 35KG / Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (2) B type depth 1.50 Metre for 150mm diameter sewer.
67(II) Extra rate for constructing B.B. masonry for every additional depth of 0.1M. GR Part thereof over item No.24.27 (I) for depth from 1.50M. to 2.25M.
68Providing and fixing Health Fauset Heavy duty with hook with fitting
69Providing laying and jointing U PVC SCH40 for cold water 20 mm dia (3/4)\\" including it's accessories.
70Drilling of 200/215mm dia, bore hole in overburden strata by DHT rin up to required depth including fixing of 175/180 dia MS ERW/PVC casing pipe & further drilling of 165mm dia. Bore hole in hard rock (trap etc.) strata by DTH drilling method up to total depth of 300 meters including measuring the yield by V notch and flushing of bore etc. complete in all districts of one V. (Casing up to 12 Mts.) From 0 to 150 meters depth.
71Providing and supplying in standered length ISI mark rigid unplastic pvc pipes suitable for potable water with ring fit joint including cost of rings, as per IS specification no.4985/1988 including all local taxes, transportation, freight charges, octroi, inspection charge, loading, unloading, conveyance to the departmental stores and including stored and including cost of jointing meterial etc. complete. Lowering, laying, fixing and jointing PVC/uPVC/cPVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of labour, material, cement solvent, giving satisfactory hydraulic testing as per ISI code. 180 mm dia.
72Supplying of single phase submersible pump set suitable for 100mm size or more dia bore well having motor capacity and discharge a under with necessary panel box. Cat.I
73Providing and supplying in standered Length ISI mark High densatay polythelene HDPE pipe sutaible for potable water as per IS specification Nr.4934/1995 including all local and central taxes, transportation, freight charges, octroi, inspection charge, loading, unloading, conveyance to the departmental store etc. complete. 25mm dia pipe. Lowering, laying, fixing and jointing HDPE pipe and specials of following class and diameter (By butt fusion welding method) including cost of conveyance from stores to site of works at all level including cost of labour, material, givin satisfactory hydraulic testing etc. comp.
74Bore plug of 100mm height made from MS plate with 3 holes at equl distance on circumference for nut-bolts type, locking arragement with nuts-bolts & lock nuts of standard make (ii) Suitable for 200mm dia pipe.
75Clamps made from MS plate with 3 holes on either side with nuts & bolts standard make and suitable size. (b) 450mm x 65mm x 10mm flat suitable to 50mm dia pipe.
76Point wiring for FAN with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of pipe erected with 6A Modular type switch and hum free EME step type electronic fan regulator mounted and accessories with earth continuity of following type erected on PVC / Metallic/Wooden box, single mounting base frame covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe erected. with necessary ceiling rose / H.D.Connector as directed.(f) with medium class Rigid PVC pipe and accessories erected concealed in wall/ceiling complete cat III
77Providing & erecting PVC Corrugated Flexible Conduit with required NOS.. of coupling, PVC bushes, Check-nuts etc. complete of followingsizes.(2) 25 mm
78Providing and erecting Sheet Steel powder coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate NOS.. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for (A) single phase incoming and horizontal single phase outgoing (b) sheet steel double door (IP-43) (ii)6 way
79providing and erecting Miniature circuit breaker single pole 6A to 25A suitable to operate on 240 V A.C. system and having breaking capacity 10 KA to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
80Providing & erecting 240 V MCB double pole switch for lighting Load (B Curve) having 10 KA breaking capacity & confirms to IS : 8828 in existing box having following capacity (A) 6 to 32 Amp. Cat-III
81Providing & erecting Approved make Power Saving 50 Watt Ceiling Fan with double ball bearing ISI mark with Condenser 230 volt A.C. 50 Hz 1200 mm sweep complete having 3blades with aluminium blades with , canopy & 30 cm. down rod erected with earthing.(Make shall be approved by Engineer in charge))
82Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe down rod erected duly painted for fan complete with proper insulation without leakage and earthing.
83Supplying & erecting fan hook box of 10 mm M.S. round bar bounded to the RCC bars up to 50mm length EACH side and pierced through a 16 Gauge M.S. box / Heavy Duty PVC box complete erected concealed in Ceiling with necessary finishing.
84Providing 2.5mm.thick laminated acrylic sheet to cover the fan hook or Fan box.
85Supplying & erecting approved make low noise decorative exhaust fan having square frame ABS body with inbuilt lowers & square frame.200mm with 1350RPM Cat.II
86Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion resistance with diffuser with company mark/name 160V to 270V, Power Factor more than 0.9, THD < 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE: Below descriPTion have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (A) Tube Light with integral driver (iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet cat III
87Providing 1:2:4 cement concrete foundation & 70 % PCC from bottom including excavation for the pole of size 45 x 45 x 100 cm. Deep in below ground level with plinth of 45 cm x 45 cm (or 45 cm dia x 45 cm) high upper ground level with necessary curing and finishing in approved manner.( for 4 & 6 mtr pole)
88Providing and erecting street light pole bracket comprising main B Class MS pipe of 4.2 cm/require outside dia. complete with suitable B Class M.S. sleeve tubing of approx. 45cms.length and suitable for 76.5 mm / 80mm. / require size pole top having sufficient fasteners for fixing the brackets and having spread of 1 MTR length with suitable rise as per site condition & suitable welded stiffener reducer and nipple with check nut complete painted with one coat of Red oxide / PU base primer and two coats of Aluminium / PU paint. paint with following NOS. of arms. [A] Single Arm bracket 1 Mtr
89Supplying and erecting LED street light / Flood light fittings with High power White LEDs wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish powder coated and heat sink extruded aluminium with diffuser and Polycarbonate oPTics/ lenses, with toughened glass with company mark/name engraved or embossed 160 to 270 V,Power Factor more than 0.95, THD < 10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.( fittings required LM-79 & LM-80 certificates)(NOTE: Below descriPTion have shown ranges of Wattage capacity of LED fittings.The Engineer incharge may select any wattage capacity between the ranges shown.) (A) Street Light (IP-65), Surge protection -4KV integral and ,Light must have 440VAC line supply with over-voltage protection. (i) above 36 to 48 watts Cat-lll
90Supply, Installation including wiring, Testing and Comissioning of 4MP Varifocal Lens Dome Type Camera,H.265 4MP IR Turret Dome N/W Camera, Manual Varifocal 2.8-12mm, 50M, Micro SD, DC12V/PoE, IP67/IK10, Basic IVA, 4MP resolution (2560 × 1440), True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Built in MIC, Cyber Security, Basic intelligent video analytics, Audio In, NDAA Compliance, UL, CE, FCC Certified (Including Five year free maintenance with guarantee)
91Supply, Installation including wiring, Testing and Comissioning of 4MP Varifocal Lens Bullet Camera, H.265 4MP IR Bullet N/W Camera, Manual Varifocal 2.8-12mm, 50M, Micro SD, DC12V/PoE,IP67/IK10, Basic IVA, 4MP resolution (2560 × 1440), True day/night, Digital WDR, 3D DNR, HLC & BLC, Triple streams, Smart codec by ROI, Cyber Security, Basic intelligent video analytics, NDAA Compliance, UL, CE, FCC Certified (Including Five year free maintenance with guarantee)
92Providing and supplying in standard length ISI mark high density Polyethylene H.D.P.E. Pipes Suitable for potable water as per IS Specification no. 4984/1995 including all local and central taxes, transportation, freight charges octrol, inspection charges loading, unloading, conveyance to the dept, stores etc. Comp.
93Supply, installation, testing and commissioning of 1.5 Ton Split Air Conditioner (Inverter Type, 5-Star Rated) complete with indoor unit, outdoor unit, wireless remote controller, copper refrigerant piping with insulation, PVC drain pipe, interconnecting power and communication cables, outdoor unit mounting brackets/stand with anti-vibration pads, electrical isolator (MCB), control wiring, condensate drain arrangement, wall sleeves, sealing, clamps, supports, fasteners, and all other necessary accessories required for a complete installation. The unit shall use eco-friendly refrigerant (R32 or equivalent) and shall be installed, tested, commissioned, and handed over in satisfactory working condition, including all labour, tools, transportation, and commissioning as per manufacturer's specifications and the Engineer-in-Charge's instructions.
94Providing, supplying, fabricating, transporting and fixing of Backlit Letters, complete with sampling and approval, CNC/laser machine cutting, digital printing/vinyl application, providing and fixing LED backlit lighting system with drivers and wiring, core cutting/drilling, scaffolding/access arrangement, installation, testing and commissioning, in all respects, as per approved drawings, specifications and directions of the Engineer-in-Charge. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56489312
AUTHORITY Government Departments
TENDER VALUE 1.25 Crore
LAST DATE 24-07-2026
Authority
Authority Name Union Territory Of Dadra And Nagar Haveli
Work Description Tender for Construction Of Security Cabin & Allied Work At Entrance Gate In South & North Zone, Dnh
Basic Detail
Tender No E-Tender Notice No. 07 of 2026-27
Bidding Type Tender
Location
City Dadra and Nagar Haveli
State Dadra and Nagar Haveli
Key Dates
Publish Date 16 Jul 2026
Submission Date 24 Jul 2026
Open Date 24 Jul 2026
Finance
Tender Value 1.25 Crore
Tender Fee 2000
EMD 2.52 Lakhs
Exemption Not Available
Document List
0df20869-b1af-4b2c-9e2f-9b79662bb9dd.html
BOQ_8344.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 24, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 24, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

0df20869-b1af-4b2c-9e2f-9b79662bb9dd.html

xls

BOQ_8344.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender