| Sl. No. | Item Description |
| 1 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineerin-charge With stainless steel cover plate minimum 1.25 mm thickness |
| 2 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5 mm depth and 5 mm width |
| 3 | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete. |
| 4 | Providing and fixing aluminium tubular handle bar 32 mm outer dia, 3.0 mm thick & 2100 mm long with SS screws etc .complete as per direction of Engineer-in-Charge. Powder coated minimum thickness 50 micron aluminium tubular handle bar |
| 5 | Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge Powder coated minimum thickness 50 micron aluminium |
| 6 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle, lock and stopper etc.to be paid separately). |
| 7 | Providing and laying integral cement based water proofing treatmentincluding preparation of surface as required for treatment of roofs,balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cementadmixed with water proofing compound conforming to IS. 2645 andapproved by Engineer-in-charge over the RCC slab including adjoiningwalls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mmto 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarsesand) admixed with water proofing compound conforming to IS : 2645and approved by Engineer-in-charge over 20 mm thick layer of cementmortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofingcompound conforming to IS : 2645 and approved by Engineer-in-chargeto required slope and treating similarly the adjoining walls upto 300 mmheight including rounding of junctions of walls and slabs.(c) After two days of proper curing applying a second coat of cement slurryusing 2.75 kg/ sqm of cement admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix1:4 (1 cement :4 coarse sand) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge includinglaying glass fibre cloth of approved quality in top layer of plaster andfinally finishing the surface with trowel with neat cement slurry and makingpattern of 300x300 mm square 3 mm deep. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. “All above operations to be done in order and as directed and specified by the Engineer-in-Charge”: With average thickness of 120 mm and minimum thicknessat khurra as 65 mm. |
| 8 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 75 to 80 mm dia pipe |
| 9 | Dismantling C.I. or asbestos rain water pipe with fittings and clamps including stacking the material within 50 metres lead : 100 mm dia pipe |
| 10 | Providing and fixing soil, waste and vent pipes : 100 mm dia Sand cast iron S&S pipe as per IS: 1729 |
| 11 | Providing and fixing soil, waste and vent pipes : 100 mm dia 75 mm diameter |
| 12 | Providing and fixing false ceiling at all heights including providing andfixing of frame work made of special sections, power pressed from M.S.sheets and galvanized with zinc coating of 120 gms/sqm (both sideinclusive) as per IS : 277 and consisting of angle cleats of size 25 mmwide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centreto centre, one flange fixed to the ceiling with dash fastener 12.5 mm diax 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the anglehangers of 25x10x0.50 mm of required length with nuts & bolts of requiredsize and other end of angle hanger fixed with intermediate G.I. channels45x15x0.9 mm running at the spacing of 1200 mm centre to centre, towhich the ceiling section 0.5 mm thick bottom wedge of 80 mm withtapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centreto centre, shall be fixed in a direction perpendicular to G.I. intermediatechannel with connecting clips made out of 2.64 mm dia x 230 mm long G.I.wire at every junction, including fixing perimeter channels 0.5 mm thick27 mm high having flanges of 20 mm and 30 mm long, the perimeter ofceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre,with 25 mm long dry wall screws @ 230 mm interval, including fixing ofgypsum board to ceiling section and perimeter channel with the help ofdry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing andfinishing to a flush finish of tapered and square edges of the board withrecommended jointing compound , jointing tapes , finishing with jointingcompound in 3 layers covering upto 150 mm on both sides of joint and twocoats of primer suitable for board, all as per manufacturer’s specificationand also including the cost of making openings for light fittings, grills,diffusers, cutouts made with frame of perimeter channels suitably fixed,all complete as per drawings, specification and direction of the Engineerin Charge but excluding the cost of painting with : 12.5 mm thick tapered edge gypsum plain board conformingto IS: 2095- (Part 1) :2011 (Board with BIS certification marks) |
| 13 | Providing and fixing factory made single extruded WPC (Wood PolymerComposite) solid plain white color board for backing of cup boards andbathroom/kitchen cabinets etc. of required size comprising of virginpolymer of K value 58-60 (Suspension Grade), calcium carbonate andnatural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum density of 650kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with propertyof being termite/borer proof, water/moisture proof and fire retardant andfixing with stainless steel screws etc. all as per direction of Engineer-In-Charge. (Note: stainless steel screws shall be paid separately) 12 mm thick |
| 14 | Providing and laying vitrified floor tiles in different sizes (thickness to bespecified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades,laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointingwith grey cement slurry @ 3.3 kg/ sqm including grouting the joints withwhite cement and matching pigments etc., complete. Size of Tile 600x600 mm |
| 15 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to1S: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of anysize as approved by Engineer-in-Charge, in skirting, risers of steps anddados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarsesand) and jointing with grey cement slurry @ 3.3kg per sqm, includingpointing in white cement mixed with pigment of matching shade complete. |
| 16 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete |
| 17 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead For thickness of tiles 10 mm to 25 mm |
| 18 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 19 | 12 mm cement plaster of mixv 1:4 (1 cement: 4 fine sand) |
| 20 | Finishing with Deluxe Multi surface paint system for interiors and exteriorsusing Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr /10 sqm |
| 21 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 22 | Painting with synthetic enamel paint of approved brand and manufactureof required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 23 | Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete |
| 24 | Making plinth protection 50 mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-lll) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75 mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 25 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 gradedstone aggregate) finished with a floating coat of neat cement, includingcement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate |
| 26 | Providing and fixing white vitreous china flat back or wall corner typelipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizesrespectively with automatic flushing cistern with standard flush pipe andC.P. brass spreaders with brass unions and G.I clamps complete, includingpainting of fittings and brackets, cutting and making good the walls andfloors wherever required : One urinal basin with 5 litre white P.V.C. automatic flushingcistern |
| 27 | Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 andIS: 1285, fixing with dash fasteners of required dia and size, includingnecessary filling up the gaps at junctions, i.e. at top, bottom and sideswith required EPDM rubber/ neoprene gasket etc. Aluminium sectionsshall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-charge. (Glazing,paneling and dash fasteners to be paid for separately) : For fixed portion Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) |
| 28 | For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provisionfor fixing of fittings wherever required including the cost ofEPDM rubber / neoprene gasket required (Fittings shall bepaid for separately) Anodised aluminium (anodised transparent ordyed to required shade according to IS: 1868,Minimum anodic coating of grade AC 15) |
| 29 | Providing and fixing stainless steel (SS 304 grade) adjustable frictionwindows stays of approved quality with necessary stainless steel screwsetc. to the side hung windows as per direction of Engineer-in-chargecomplete. 205 X 19 mm |
| 30 | Providing and fixing fly proof galvanized M.S. wire gauge to windows andclerestory windows using wire gauge with average width of aperture 1.4mm in both directions with wire of dia 0.63 mm all complete. With second class teak wood beading 62X19 mm |
| 31 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part 1) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneering withvertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hingeswith necessary screws |
| 32 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, includingcutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440mm with integral type foot rests |
| 33 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group B |
| 34 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 35 | Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm |
| 36 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required. 180 mm X 100 mm X 60 mm deep |
| 37 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required 5/6 A switch |
| 38 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module |
| 39 | Providing and fixing of PVC wall paneling over Existing Tile/Plastered surface with high quality PVC panel complet with all fittings like cleats nails screw etc. The rates inclusive wastage, labour and other necessary fittings complete as per direction of Engineer-in-Charge. |
| 40 | Supply and fixing of Exhaust Fan Make Havels or Equivalent |
| 41 | Supply and fixing of Photon Mirror Light Make Phillips or Equivalent |
| 42 | Supply and fixing of Simline Compact LED Tube Light 20 Watt Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 20, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJul 21, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender