Housing Urban and Rular Development Government Departments Closing in 3 days TDR #56488966

Tender For repair maintenance electrical installation & Fans, Compound Lights, Pump Sets, Ro System & Air Conditioning Units Installed At Dseu-1 (Polytechnic & Printing Technology) Pusa, New Delhi During 2026-27. (Sh : electrical installation Work, M

Issued by Government Departments · New Delhi, Delhi
Tender Value
40.37 Lakhs
Estimated cost
Bid Submission
22 Jul 2026
3 days left
EMD
80741
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for repair maintenance electrical installation & Fans, Compound Lights, Pump Sets, Ro System & Air Conditioning Units Installed At Dseu-1 (Polytechnic & Printing Technology) Pusa, New Delhi During 2026-27. (Sh : electrical installation Work, Maintenance Of Air Conditioner & Pump Etc.).

BOQ

Name of Work:- RMO EI & Fans, compound lights, pump sets, RO system & Air Conditioning units installed at DSEU-1 (Polytechnic & Printing Technology) Pusa, New Delhi during 2026-27. (SH : EI work, maintenance of Air Conditioner & pump etc.).
Sl. No. Item Description
1SH-I (EI Work)Operation of 11 KV electric sub-station equipments (excluding 250 KVA transformer installed at Polytechnic), DG sets installed as per inventory at DSEU -I (Polytechnic & Printing Technologry), & Operation and preventive maintenance of pump set installed at above Site to fill up over head tank i/c timely operation of valves of O.H. tank and underground tank to delivery water supply in various building on all days of the month i/c attending day to day complaints of EI and fans, rectification of fault, upkeeping and preventive maintenance complete etc. as reqd. by providing following minimum staff as per terms & conditions enclosed.
2a) Wireman cum DG Set Operator cum Pump Operator - 3 No.(Round the clock) (One in each shift) (Including Sunday & Holiday)
3Wireman 1 No (In General Shift) (Excluding Sunday & Holiday)
4Khallasi – 1 No. (In General Shift) (Excluding Sunday & Holiday)
5SH- II- (Supply of material)Following material /electrical accessories shall be supply by agency and fixing will be done by the existing man power existing for replacement on day to day maitenance works etc as required. (Labour already included in Item No. 1 & 2 Sub Head - I.)
65 Amp Modular Switch
75 Amp Modular Socket
815/16 Amp Modular Switch
915/16 Amp Modular Socket
10S.P. 5/6 A, one way switch, piano type ISI marked
11S.P. 15/16 A, one way switch, piano type ISI marked
123 pin 5/6 A socket outlet, piano type ISI marked
136 pin 15/16 & 5/6 A socket outlet, piano type ISI marked
143 mm thick phelonic laminated sheet
156 to 32 Amp c Curve SP MCB, \\"C\\" curve, 10 kA breaking capacity
166 amps. to 32 amps. ratings , DP MCB, “C” curve, 10 KA breaking capacity
176 amps. to 32 amps. ratings , SPN MCB, “C” curve, 10 KA breaking capacity
186 amps. to 32 amps. ratings , TP MCB, “C” curve, 10 KA breaking capacity
196 amps. to 32 amps. ratings , TPN MCB, “C” curve, 10 KA breaking capacity
2040 amps., 2 pole isolator
2163 amps., 2 pole isolator
2240 amps., 4 pole isolator
2363 amps., 4 pole isolator
24100 amps., 4 pole isolator
251.5 Sq.mm FRLS Copper wire
264 Sq.mm ISI marked FRLS copper wire
276 Sq.mm FRLS Copper wire
282.50 mfd fan capacitor
291200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM / Min (Minimum) BLDC Fan
301400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/ Min (Minimum) BLDC Fan
31300 mm sweep heavy duty exhaust fans
32380 mm sweep heavy duty exhaust fans
33Call bell/ buzzer, single phase
34Stepped type Modular Fan regulator (2 module)
35Modular base & cover plate for 3 module
36Modular base & cover plate for 6 module
37Modular base & cover plate for 8 module
38Modular base & cover plate for 12 module
393 pole MCCB, 100A, 16kA
403 pole MCCB, 125A, 16kA
413 pole MCCB, 400A, 35kA
42Supplying of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140- 270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, Flicker free (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
4336 watt
44Supplying of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness > 0.50 mm)
4536 watt
46Supplying, Installation, Testing & Commissioning of Flood Light, powder coated pressure die cast aluminium body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMI-EMC as per CISPR-15, lenses for beam angle 30 deg-120deg as per the application and the project requirement, suitable tilt able fitting, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 and <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
47150 watt
48Supplying, installation, Testing & Commissioning of Street light LED fixture powder coated pressure die cast aluminium body with driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, frequency 50/60 hz, Operating temp range -5 0C to 50 0C, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2, P. F.≥0.95, IP-66,IK-10, CRI >70, under voltage and over voltage protection, EMIEMC As per CISPR 15 , lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED, Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard Deviation Colour Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output . LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).
49120 watt
50Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
51Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
52Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
53Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
54Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable in surface/recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor single core cable etc. as required.
55Group C
56Supplying & laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade aluminium armoured cable of following size for existing RCC/HUME/METAL pipe/Air/Surface etc complete as required.
574 x 25 Sq.mm
58SH- III- (Pump)Supplying, Installation, Testing & Commissioning of Borewell submersible Pump set of following capacity suitable for working on 3 phase,415 volts A.C. supply 50 Hz i/c lowering in the sump well with the help of chain pulley block and tripod stand, connecting with existing delivering pipe lines, connections etc complete as reqd.
59Head 320-40 mtrs., discharg 0-105 LPM, 7.5 HP
60Lowering of 3/5/7.5/10 H.P. Submersible/ Mono-submersible pump/Sewage Submersible pump /sets in the underground tank or Borewell along with existing GI Pipe submersible cable etc. With the help of tri-port and chain pully block including P/F nub bolts, rubber packing, including testing, commissioning etc as required.
61Mono-Submersible Pump Set/Dewatering Pump Set.
62Lifting of 3/5/7.5/10 H.P. Submersible/ Mono-submersible pump/Sewage Submersible pump /sets from the underground tank or Borewell with the help of tri-port and chain pully block along with existing GI pipe and submersible cable etc complete as required.
63Mono-Submersible Pump Set/Dewatering Pump Set.
64Rewinding Mono Submersible pump sets of following rating including cutting the burnt winding wire including rewinding the same with high quality motor resistance PVC Insulated copper winding the wire and credit of dismantled material i/c testing commissioning complete etc. as reqd.
655 HP Mono Sbmersible Pump
66Providing and fixing of following 5 HP Mono Submersible spare parts in the above motor i/c credit of old dismantled material etc as reqd.
67Rematling of shaft and Turning & Polishing of Rotor sleeve- 1 job
68G.M. Bush - 4 Nos.
69Rematling of Impeller& Neck ring- 1job.
70Oil/Water Seal- 2 Nos.
71Flat Cable 3X2.5 Sq.mm- 5 Mtr.
72Thrust plate and Thrust Bearing- 1Set
73Supplying & fixing PVC insulated PVC sheathed copper conductor submersible flat cable ISI Marked in existing metal/ HDPE / PVC/ pipe/ in bore well/ in sump including fixing the cable to GI/HDPE pipe with suitable cable tags of following sizes etc. complete as required.
743 Core 4.0 Sq mm Flat Cable
75SH- IV(Comprehensive maintenance of AC)Comprehensive & Routine maintenance of 7 Nos. WTAC / STAC unit i/c attending day to day complaints and rectify the defects, supplying and replacement of wornout parts such as starting / running capacitors, starting relays, overload relay, tharmostat, selector switches, sleeves, knobes, connector and associated control wiring, filter, drain pipe etc which reqd to be replace during routine maintenance and monthly cleaning of filters etc. (Replacement of compressor, condensor unit, cooling coil unit, blower, fan blower motor, front grill, man leads, gas charging etc not covered under routine maintenance) complete as per terms & conditons.
76Servicing of existing installed WTAC / STAC of 1.5 TR & 2.0 TR capacity AC and water coolers of 80/150/250 LPH, checking for unit, inspection, greasing, oiling etc i/c chemical cleaning of the condensing coil with high pressure pump changing the air filter, checking & tightening all electic connection, testing the machine etc as reqd.
77Providing and fixing WTAC /STAC fan motor capcity 1/4 to 1/8 HP etc complete as required.
78Supplying & charging of M-22 / R-22 gas in the exising WTAC / STAC of 1.5TR unit i/c pressure testing, flushing the system & gas charging complete etc
79Supplying & charging of M-22 / R-22 gas in the exising WTAC / STAC of 2 TR unit i/c pressure testing, flushing the system & gas charging complete etc as
80Supplying & fixing of 25 mm dia PVC heavy duty pipe drainage in the existing split type AC unit with supporting clamps etc complete as reqd
81Repair of damaged PCB of indoor and outdoor unit i/c tightening the loose connection, testing the machine etc as required
82Supplying & fixing of copper refrigerant pipe of size 1/4\\", 5/8\\" with insulation and copper wire 3 core 4 sq.mm i/c making all connections in the AC units etc as per reqd at site.
83Supplying & fixing of Fan blower suitable for 1.5/2.0 ton indow/Split AC i/c connections, testing, commissioning etc complete as reqd.
84Supplying & fixing of 1.5 TR capacity rotary compressor in the existing WTAC / Split AC making copper pipe connection, brazong pressure testing and supplying and charging M-22 refrigerant gas charging i/c cutting the copper piping dismantling etc. complete as required.
85Providing and fixing of follwing WTAC /STAC accessories i/c dismantling & credit of the burnt materials from the existing unit & fixing & making connection, testing complete etc as reqd:-
861.5 / 2 TR Condensor Coil
87SH-V (Credit Material)Credit for old dismantle material as and where basis etc as reqd.
88Old fan blower motor 1.5 / 2 TR
89Fan blower
90Old assorted copper wire
91Old assorted aluminium wire
92Old assorted size Switch & sockets
93Old assorted 1200 mm Ceiling Fan
94Old assorted 1400 mm Ceiling Fan
95Old assorted Exhaust Fan
96Old assorted MCB (6-32 Amp)
97Old assorted DP/Isolator/TP (32/40/63/100Amp)
98Old assorted size submerible pump
99DG set accessories i/c fillter, mobil oil, battery, starter, charger etc Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56488966
AUTHORITY Government Departments
TENDER VALUE 40.37 Lakhs
LAST DATE 22-07-2026
Authority
Authority Name Public Works Department
Work Description Tender for repair maintenance electrical installation & Fans, Compound Lights, Pump Sets, Ro System & Air Conditioning Units Installed At Dseu-1 (Polytechnic & Printing Technology) Pusa, New Delhi During 2026-27. (Sh : electrical installation Work, Maintenance Of Air Conditioner & Pump Etc.).
Basic Detail
Tender No 41/EE (E)/PWD EMD South West/2026-27
Bidding Type Tender
Location
City New Delhi
State Delhi
Key Dates
Publish Date 15 Jul 2026
Submission Date 22 Jul 2026
Open Date 22 Jul 2026
Finance
Tender Value 40.37 Lakhs
Tender Fee Ref. Documents
EMD 80741
Exemption Not Available
Document List
b6c76b57-5e55-43e9-9793-af8b7804f70e.html
BOQ_393076.xls
Tendernotice_1 (10).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 22, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 3 days
Jul 22, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 3 days

Tender Documents

Download All (ZIP) ↓
html

b6c76b57-5e55-43e9-9793-af8b7804f70e.html

xls

BOQ_393076.xls

pdf

Tendernotice_1 (10).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail