Agriculture Government Departments Closing in 4 days TDR #56488278

Tender For Supply, Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Under Cherthala Legislative Assembly Constituency Of Alappuzha District Of Kerala With The Specifications Given Below.

Issued by Government Departments · Alappuzha, Kerala
Tender Value
60 Lakhs
Estimated cost
Bid Submission
27 Jul 2026
4 days left
EMD
60000
Bank guarantee accepted
Document Fee
12000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Alappuzha → Kerala
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Supply, Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Under Cherthala Legislative Assembly Constituency Of Alappuzha District Of Kerala With The Specifications Given Below. , Suitable For Handling Saline And Silty Water With Rpm 960 (Sync) Or Less. The Material Of Construction Of Flange, Suction Bell, Bowl, Shroud Shall Be Ci With 2% Nickel. Impeller, Shaft, Shaft Sleeve, Fastener Shall Be Of Ss 304. Suction Pipe And Delivery Pipe Should Be In Ss 304 With Minimum Thickness 6 Mmand Of Suitable Length (Varies From 4-10M) Or As Per Site Condition. The Prime Mover Of The Pump Is To Be 3 Phase Tefc Squirrel Cage Induction Motor Of Reputed Make Having Star Rating Above4 Operating At 415V +/- 10%, 50 Hz +/- 5% Connection With F Class Insulation, Control Panel Must Have Dust And Vermin Proof Vertical Mounted Cubical Type Panel Board Of Reputed Make With Fcma Soft Starterofreputed Make, Mccb Including Phase Failure Protection, Surge Protection Device, Dry Run Protection, Overload Over Current Protection, Thermal Overload Protection Relay, Earth Fault Relay, Voltmeter-Ammeter Fault Indication, Start And Stop Switches And Power Factor Correction Capacitor Etc. Wiring And Earthing Should Be As Per Regulations Of Kseb And Electrical Inspectorate. Separate Cubical Type Energy Meter Panel With Ct Metering Provision Including 4 Pole Fn Type Isolator, Rccb , Hrc Fuses And Carrier. Suitable Size Copper Cable For Connection From Electric Post To Meter Box And Meter Panel To Motor Control Panel Etc. Should Be Fitted At Site, With Proper Earthing. Cable Termination Should Be As Per The Regulations And Specifications Of Kseb And Electrical Inspectorate Standards. Screen With 6Mm Gi Welded Mesh With 50 Mm X 50 Mm Opening Size (About 20 Sq.M Area) Framed In Gi Angles And Gi Tubes Fitted At The Opening On Top And Sides Of Sump To Prevent Entry Of Unwanted Materials To The Pump Through Inflow Water. Proper I-Section Should Be Provided For Supporting The Motor Mountings And Pedestal. Suitable Chain Block And Tripod Facilities To Be Provided For Lifting The Motor At Least 1.00 M Above Maximum Flood Level. Rate Quoted Should Be Inclusive Of All The Charges For Supply, Installation Including Trial Run And Commissioning, All Types Of Transportation And Conveyance, Loading And Unloading Charges, Charges For Factory Testing, But Excluding Gst Etc. , Duty Point Head (M): 2.5 Working Range (M): 0.5M To 3.5M Minimum Discharge At Duty Point Head (Lps): 912 Minimum Overall Efficiency At Duty Point (%) : 60 Available Connected Load: 50 Hp

BOQ

Name of Work:- Supply, erection, testing and commissioning of Vertical Axial Flow pump set (Non-Submersible) for various padashekarams under Cherthala Legislative Assembly Constituency of Alappuzha district of Kerala with the specifications given below.
Sl. No. Item Description
1Suitable for handling saline and silty water with rpm 960 (Sync) or less. The material of construction of flange, suction bell, bowl, shroud shall be CI with 2% Nickel. Impeller, Shaft, shaft sleeve, fastener shall be of SS 304. Suction pipe and Delivery pipe should be in SS 304 with minimum thickness 6 mmand of suitable length (varies from 4-10m) or as per site condition. The prime mover of the pump is to be 3 phase TEFC squirrel cage induction motor of reputed make having star rating above4 operating at 415V +/- 10%, 50 Hz +/- 5% connection with F class insulation, control panel must have dust and vermin proof vertical mounted cubical type panel board of reputed make with FCMA soft starterofreputed make, MCCB including phase failure protection, surge protection device, dry run protection, overload over current protection, thermal overload protection relay, earth fault relay, voltmeter-ammeter fault indication, start and stop switches and power factor correction capacitor etc. Wiring and earthing should be as per regulations of KSEB and electrical inspectorate.Separate cubical type energy meter panel with CT metering provision including 4 Pole FN type isolator, RCCB , HRC fuses and carrier. Suitable size Copper cable for connection from electric post to meter box and meter panel to motor control panel etc. should be fitted at site, with proper earthing. Cable termination should be as per the regulations and specifications of KSEB and Electrical Inspectorate standards.Screen with 6mm GI welded mesh with 50 mm x 50 mm opening size (about 20 sq.m area) framed in GI angles and GI tubes fitted at the opening on top and sides of sump to prevent entry of unwanted materials to the pump through inflow water. Proper I-section should be provided for supporting the motor mountings and pedestal. Suitable chain block and tripod facilities to be provided for lifting the motor at least 1.00 m above maximum flood level.Rate quoted should be inclusive of all the charges for supply, installation including trial run and commissioning, all types of transportation and conveyance, loading and unloading charges, charges for factory testing, but excluding GST etc.
2Duty Point Head (m): 2.5Working Range (m): 0.5m to 3.5mMinimum discharge at Duty Point Head (lps): 912Minimum overall efficiency at duty point (%) : 60Available Connected Load: 50 Hp Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56488278
AUTHORITY Government Departments
TENDER VALUE 60 Lakhs
LAST DATE 27-07-2026
Authority
Authority Name Department Of Agriculture
Work Description Tender for Supply, Erection, Testing And Commissioning Of Vertical Axial Flow Pump Set (Non-Submersible) For Various Padashekarams Under Cherthala Legislative Assembly Constituency Of Alappuzha District Of Kerala With The Specifications Given Below. , Suitable For Handling Saline And Silty Water With Rpm 960 (Sync) Or Less. The Material Of Construction Of Flange, Suction Bell, Bowl, Shroud Shall Be Ci With 2% Nickel. Impeller, Shaft, Shaft Sleeve, Fastener Shall Be Of Ss 304. Suction Pipe And Delivery Pipe Should Be In Ss 304 With Minimum Thickness 6 Mmand Of Suitable Length (Varies From 4-10M) Or As Per Site Condition. The Prime Mover Of The Pump Is To Be 3 Phase Tefc Squirrel Cage Induction Motor Of Reputed Make Having Star Rating Above4 Operating At 415V +/- 10%, 50 Hz +/- 5% Connection With F Class Insulation, Control Panel Must Have Dust And Vermin Proof Vertical Mounted Cubical Type Panel Board Of Reputed Make With Fcma Soft Starterofreputed Make, Mccb Including Phase Failure Protection, Surge Protection Device, Dry Run Protection, Overload Over Current Protection, Thermal Overload Protection Relay, Earth Fault Relay, Voltmeter-Ammeter Fault Indication, Start And Stop Switches And Power Factor Correction Capacitor Etc. Wiring And Earthing Should Be As Per Regulations Of Kseb And Electrical Inspectorate. Separate Cubical Type Energy Meter Panel With Ct Metering Provision Including 4 Pole Fn Type Isolator, Rccb , Hrc Fuses And Carrier. Suitable Size Copper Cable For Connection From Electric Post To Meter Box And Meter Panel To Motor Control Panel Etc. Should Be Fitted At Site, With Proper Earthing. Cable Termination Should Be As Per The Regulations And Specifications Of Kseb And Electrical Inspectorate Standards. Screen With 6Mm Gi Welded Mesh With 50 Mm X 50 Mm Opening Size (About 20 Sq.M Area) Framed In Gi Angles And Gi Tubes Fitted At The Opening On Top And Sides Of Sump To Prevent Entry Of Unwanted Materials To The Pump Through Inflow Water. Proper I-Section Should Be Provided For Supporting The Motor Mountings And Pedestal. Suitable Chain Block And Tripod Facilities To Be Provided For Lifting The Motor At Least 1.00 M Above Maximum Flood Level. Rate Quoted Should Be Inclusive Of All The Charges For Supply, Installation Including Trial Run And Commissioning, All Types Of Transportation And Conveyance, Loading And Unloading Charges, Charges For Factory Testing, But Excluding Gst Etc. , Duty Point Head (M): 2.5 Working Range (M): 0.5M To 3.5M Minimum Discharge At Duty Point Head (Lps): 912 Minimum Overall Efficiency At Duty Point (%) : 60 Available Connected Load: 50 Hp
Basic Detail
Tender No ADFW/EXE/ALP/53/2026-EE2
Bidding Type Tender
Location
City Alappuzha
State Kerala
Key Dates
Publish Date 16 Jul 2026
Submission Date 27 Jul 2026
Open Date 28 Jul 2026
Finance
Tender Value 60 Lakhs
Tender Fee 12000
EMD 60000
Exemption Available
Document List
66322734-6e2e-4870-8a62-d755784f8edc.html
ann1.pdf
ann2.pdf
BOQ_1455411.xls
KFC14.pdf
nit.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 27, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 4 days
Jul 28, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 5 days

Tender Documents

Download All (ZIP) ↓
html

66322734-6e2e-4870-8a62-d755784f8edc.html

pdf

ann1.pdf

pdf

ann2.pdf

xls

BOQ_1455411.xls

pdf

KFC14.pdf

pdf

nit.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders