Defence Statutory Bodies & Commissions/Committees Closing in 11 days TDR #56488150

Tender For Provisioning Of A 11Kv/415V, 160 Kva Distribution Transformer Along With Distribution Feeder Pillar Panel And Ab Switches Near Bamboo Villa For Facilitating Reliable Power Supply.

Issued by Statutory Bodies & Commissions/Committees · Balangir, Odisha
Tender Value
23.73 Lakhs
Estimated cost
Bid Submission
10 Aug 2026
11 days left
EMD
48000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Balangir → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Provisioning Of A 11Kv/415V, 160 Kva Distribution Transformer Along With Distribution Feeder Pillar Panel And Ab Switches Near Bamboo Villa For Facilitating Reliable Power Supply.

BOQ

Name of Work:- Provisioning of a 11KV/415V, 160 KVA Distribution Transformer along with distribution feeder Pillar Panel and AB switches near Bamboo Villa for facilitating reliable power supply.
Sl. No. Item Description
1Provisioning of a 11KV/415V, 160 KVA Distribution Transformer along with distribution feeder Pillar Panel and AB switches near Bamboo Villa for facilitating reliable power supply.
2Labour for excavating trenches in hard/ dense soil not exceeding 1.5 m wide & not exceeding 1.5 m depth for laying of electrical power cable and getting earth out.
3Labour for returning the excavated earth in trench including spreading, levelling & well ramming in layers not exceeding 25 cm.
4M & L for sand filling in cable trench including consolidation for protection of electrical power cable.
5M & L for continuos brick edging, with width equal to the depth of the brick, laid dry with burnt clay bricks of sub class B with old size bricks.
6Labour for demolition of cement concrete or black bituminous hard standing of any description and in any position not otherwise specifically provided.
7Material & Labour for cement concrete of type C2 (1:3:6) with 40 mm graded aggregate in making cable trenches for power cable.
8M & L for Mild Steel Bars of Fe-410-W (Gde. E-250) Quality A of 10 MM Dia and Over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns and binding with & including mild steel wire not less than 0.9mm dia or securing with clips.
9M & L for Mild Steel Bars of Fe-410-W (Gde. E-250) Quality A of 8 MM Dia and Over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns and binding with & including mild steel wire not less than 0.9mm dia or securing with clips.
10S & F of Galvanised 2 Strand, Barbed Wire 2.24 MM Dia Barbed with 2 MM Dia Barbs at 75 MM Spacings and Straining and Fixing to any type of Standard rails straining bolts, including , securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (Each line wire to be measured).
11Framed work with galvanised iron angle of size 50 x 50 x 4 mm, 100 X 50 x 4 mm Channel, GI Clamp etc. complete, drilled for fixing of steel sheeting or other covering and hanging; also fastening and fixing complete.
12M & L for 25 X 4 mm dia galvanised iron strip for earth continuity conductor to be fixed to pole or buried in ground or drawn in conduit from earth pit near LT panel & Transformer.
13Supply, Installation, Testing & Commissioning of 160 KVA , 11/0.433 KV, Step Down Distribution Transformer, Outdoor Type, Copper Wound with all accessories as per functional requirement. Type Test Certificate issued from any NABL Accredited or Govt. Laboratory to be provided before completion of commissionig. Primary side of Transformer will be suitable for connection through 11KV Overhead ACSR Conductor & the secondary side shall have compartment for suitable termination of cable.
14Supply, Installation, Testing & Commissioning of 3 Pole, Gang Operated, 400 A, 11000V, Air Break Switch with Polymer Insulator ( 2 Nos. of Polymer Insulator Per Phase), Outdoor Type, Vertical Opening & Closing, With Complete Accessories Like Down Rod, Operating Handle. The contacts of AB Switch shall be brass or alloy as be suitable for aluminium conductor. Type Test Certificate issued from any NABL Accredited or Govt. Laboratory to be provided before completion of commissionig. It includes all fixing accessories related to AB Swicth.
15Supply, Installation, Testing & Commissioning of 3 Pole, Drop Out Fuse, 20 A, 11000V, with Polymer Insulator ( 2 Nos. of Polymer Insulator Per Phase), Outdoor Type, Vertical Installation, With Complete Accessories Like Base Assembly, Insulator, Fuse. The contacts shall be suitable for aluminium conductor at both end. Type Test Certificate issued from any NABL Accredited or Govt. Laboratory to be provided before completion of commissionig. It includes all fixing accessories related to DO fuse.
16Supply, Installation, Testing & Commissioning of Lightening Arrestor, 11000V, Discharge Capacity 65KA, with Polymer Insulator, 1 Set Per Phase, Outdoor Type, Vertical Installation, With Complete Accessories Like Base Assembly. The contacts shall be suitable for aluminium conductor at both end. Type Test Certificate issued from any NABL Accredited or Govt. Laboratory to be provided before completion of commissionig. It includes all fixing accessories related to Lightening Arrestors.
17Laying of one number of XLPE insulated and PVC sheathed power cable of 1.1 KV grade of size above 35 Sq. MM to 95 Sq.MM in the existing masonry open duct or in cable trench.
18Laying of one number of XLPE insulated and PVC sheathed power cable of 1.1 KV grade of size above 185 Sq. MM to 400 Sq.MM in the existing masonry open duct or in cable trench.
19Supplying & making end termination with brass compression gland and aluminium lugs for 3.5 Core 70 Sq. MM (38 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required.
20Supplying & making end termination with brass compression gland and aluminium lugs for 3.5 Core 120 Sq. MM (45 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required.
21Supplying & making end termination with brass compression gland and aluminium lugs for 3.5 Core 150 Sq. MM (50 MM) PVC Insulated and Sheathed aluminium conductor cable of 1.1 KV grade as required.
22Earthing with GI earth plate 600mm x 600mm x 6mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and water pipe of 2.7 metre etc. with charcoal/coke and salt as required.
23Supplying & fixing cable route marker with 10 cm x 10 cm x 5 mm thick GI plate with inscription there on, bolted/welded to 35 mm x 35 mm x 6 mm angle iron, 60 cm long and fixing the same in the ground as required.
24SUPPLY, INSTALLATION, TESTING & COMMISSIONING OF 415V, 50HZ, OUT DOOR (DOUBLE DOOR) TYPE STAND MOUNTED LT FEEDER PANEL BOARD FABRICATED OUT OF 2 MM THICK MS SHEET FOR LAOD BEARING PART & 1.6 MM THICK SHEET FOR OTHER BODY PART, DULY POWDER PAINTED, CANOPY SHOULD BE EXTENDED IN FRONT AND TWO ADJACENT SIDES APPROX. 100MM SO THAT WATER SPILLAGE CAN BE PREVENTED, ALUMINIUM BUS BAR FOR THREE PHASE & NEUTRAL WITH CURRENT CARRYING CAPACITY OF 630A, SUITABLE AL. BUS BAR FOR EARTHING, 1 NO. OF 400 AMP MCCB FOR INCOMER, 1 NO. 100A MCCB OUTGOING FEEDER HAVING SUITABLE TIMER, CONTACTOR & ACCESSORIES FOR STREET LIGHT CONTROL, 1 NO. OF 125 AMP MCCB FOR OUTGOING FEEDER, 1 NO. OF 160 AMP MCCB FOR OUTGOING FFEDER & 1 NO. 200 A MCCB FOR OUTGOING FEEDER, R-Y-B ALONG WITH ON , OFF, TRIP INDICATOR FOR INCOMER AND ON, OFF, TRIP LED INDICATOR FOR ALL OUTGOING MCCB FEEDER, 1 NO. OF DIGITAL MFM WITH KWH, PF, V, A ETC. IN INCOMER, 1 NO. OF DIGITAL VOLTMETER WITH SELECTOR SWITCH IN INCOMER AND 1 NO. OF DIGITAL AMMETER WITH SELECTOR SWITCH IN EACH OUTGOING FEEDER. ADEQUATE SPACE TO BE PROVIDED FOR CABLE CABLE MOVEMENT AND TERMINATION, DETACHEABLE GLAND PLATE AT BOTTOM. ALL MATERIALS TO BE USED SHALL BE OF ISI MARKED OR CONFORMING TO RELEVANT IS STANDARDS. TYPE TEST CERTIFICATE ISSUED FROM NABL OR ANY CENTRAL GOVT. LABORATORY TO BE SUBMITTED BEFORE COMMISSIONING OF PANEL. HOWEVER, PANEL TO BE FABRICATED IN COMPLIANCE WITH IS: 8623 OR OTHER RELEVANT. IT INCLUDES ALL SWITCH GEARS LIKE MCCB/MCB, MFM ETC. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56488150
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 23.73 Lakhs
LAST DATE 10-08-2026
Authority
Authority Name Munitions India Limited
Work Description Tender for Provisioning Of A 11Kv/415V, 160 Kva Distribution Transformer Along With Distribution Feeder Pillar Panel And Ab Switches Near Bamboo Villa For Facilitating Reliable Power Supply.
Basic Detail
Tender No 3012/OFBL/TE-07-2026-27/RD2607
Bidding Type Tender
Location
City Balangir
State Odisha
Key Dates
Publish Date 15 Jul 2026
Submission Date 10 Aug 2026
Open Date 13 Aug 2026
Finance
Tender Value 23.73 Lakhs
Tender Fee Ref. Documents
EMD 48000
Exemption Not Available
Document List
591e3a6c-f045-4187-9858-add9c07ffa05.html
BiddersComplianceforTE-07-2026-27.xls
BOQ_331598.xls
IMPORTANT-NOTE-CIVIL-ELEC_1.pdf
Indemnity-Bond.pdf
Remedial-Measure-of-Safet_2.pdf
ScopeofWorkR.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 11 days
Aug 13, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 14 days

Tender Documents

Download All (ZIP) ↓
html

591e3a6c-f045-4187-9858-add9c07ffa05.html

xls

BiddersComplianceforTE-07-2026-27.xls

xls

BOQ_331598.xls

pdf

IMPORTANT-NOTE-CIVIL-ELEC_1.pdf

pdf

Indemnity-Bond.pdf

pdf

Remedial-Measure-of-Safet_2.pdf

pdf

ScopeofWorkR.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders