Tender For Special Repair To Building No T-63 And T-426 At Nimu Mil Stn Under Age (I) Nimu.
Tender Value
32.72 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
5 days left
EMD
65500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Leh → Ladakh
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender For Special Repair To Building No T-63 And T-426 At Nimu Mil Stn Under Age (I) Nimu.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling timber scantling 40 sqcm and over in section, in any position in framed work in scantling etc complete all as specified and directed by Engr-in-charge. |
| 2 | M&L second class Hard wood in clean sawn timber fixed and fixed in scantlings complete all as specified and directed by Engr-in-charge. |
| 3 | Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position as in framed work complete all as specified and directed by Engr-in-charge. |
| 4 | M & L for 2nd class hard wood Plain fillets. exc. 13 & n.exc 25 Sq cm as in square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed by Engr-in-charge. |
| 5 | All as per item No 4 , but exc 3 & n.exc 6 Sq cm in bullnosed, splayed, chamfered or rounded on one edge or face as in beadding complete all as specified and directed by Engr-in-charge. |
| 6 | Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness including cover fillets complete all as specified and directed by Engr-in-charge. |
| 7 | M & L Prelaminated particle board 9mm thick, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails in ceiling, flat or sloping to timber frame work complete all as specified and directed by Engr-in-charge. |
| 8 | S&F 9mm thick Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with nails to timber frame work as in walls all as specified and directed. |
| 9 | Taking down Chowkhats or frames exc 1.5 Sqm but not exc. 4 sq. m each but with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-charge. |
| 10 | Taking down Chowkhats or frames n exc 1.5 Sqm each but with shutters (without taking off shutters from the frames) complete all as specified and directed by Engr-in-charge. |
| 11 | M&L 2nd class hardwood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed complete all as specified and directed by Engr-in-charge. |
| 12 | M&L 2nd class hardwood 35mm thick Plain, framed, panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats for doors complete all as specified and directed by Engr-in-charge. |
| 13 | M&L 2nd class hardwood 30mm thick Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats complete all as specified and directed by Engr-in-charge. |
| 14 | S&F Mild steel 100mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-charge. |
| 15 | S&F Mild steel 75mm long Butt hinges, medium weight, cold rolled mild steel, and fixed complete all as specified and directed by Engr-in-charge. |
| 16 | S&F extruded aluminium alloy handles, fabricated type, anodised 150mm long complete all as specified and directed by Engr-in-charge. |
| 17 | S&F extruded aluminium alloy handles, fabricated type, anodised 100mm long complete all as specified and directed by Engr-in-charge. |
| 18 | S&F Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed 250mm long complete all as specified and directed by Engr-in-charge. |
| 19 | S&F Aluminium anodised, barrel tower bolt of extruded section and fixed, 150mm long (ISI marked), complete all as specifie complete all as specified and directed by Engr-in-charge.. |
| 20 | S&F Aluminium anodised, barrel tower bolt of extruded section and fixed, 100mm long (ISI marked), complete all as specified complete all as specified and directed by Engr-in-charge. |
| 21 | Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed by Engr-in-charge |
| 22 | M&L 75mm thick cement concrete type C-2, 1:3:6 (40mm graded aggregate) as in plinth protection even & smooth without using extra cement complete all as specified and directed by Engr-in-charge. |
| 23 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but including backing ), rubbish off the premises complete all as specified and directed by engr-in-Charge. |
| 24 | M&L 25 mm thick cement concrete type B-1, 1:2:4 using (20 mm graded aggregate) as in base complete all as specified and directed by Engr-in-charge. |
| 25 | M&L for Chequered cement concrete tiles 20cm x 20cm x25mm thick, set, jointed and pointed in neat cement slurry with grey cement and no pigment in floors over screed bed or bedding layer of mortar 15mm thick in CM 1:6 including 50 mm thick PCC 1:4:8 type D-2 as base complete all as specified d and directed byEngr-in-charge. |
| 26 | M&L for Coloured non skid Ceramic tiles 7 to 8mm thick area of each tile exc 0.18 Sqm but n exc 0.38 Sqm in floor etc incl 15 mm thick screed bed in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 27 | M&L for Non - skid coloured Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. over 15mm thick Screed bed or bedding layer of mortar 15 mm thick for laying floor finishes in CM 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified. |
| 28 | S&F Sheet glass, ordinary quality, in squares n exc 0.5 sq. m each pane and Securing glass of any description in existing wooden frames glazed with putty/ beads complete all as specified and directed. |
| 29 | M&L for preparation of new wood surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coats of Synthetic enamel (ordinary tint) over a coat of pink primer complete all as specified and directed by Engr-in-charge. |
| 30 | Dismantling Plain or corrugated steel sheeting,any gauge, thickness, including Nainital or similar pattern roof coverings. |
| 31 | S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified. |
| 32 | Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 33 | S&F for Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors;fixed with angle cleats or other connecting plates Fe-290 (Gde E-165) |
| 34 | Rolled mild steel sections as in framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc. Fe 410 -W (Gde-E- 250) quality-A |
| 35 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 36 | M&L for preparation of old painted steel surfaces of any description, over 10cm in width or girth, not otherwise described and applying two coats of Synthetic enamel paint (ordinary tint) complete all as specified and directed by Engr-in-charge. |
| 37 | M&L for Precast cement concrete block in PCC 1:3:6 type C1 (using 20 mm graded aggregate) masonry with solid block exc. 10 cm in width and setting in mortar 1:4 complete all as specified. |
| 38 | Demolition of precast concrete block walling masonry, built in cement mortar |
| 39 | M&L for Rendering 15mm thick on fair faces of concrete block masonry surfaces in cement mortar (1:4). |
| 40 | M&L preparing new plastered surfaces of walls and applying two coat of cement base paint over a coat of primer all as specified and directed by Engr-in-charge. |
| 41 | M&L glazed ceramic tile \\" coloured\\" 450mmx 300mm x 7mm as in verticle surface such as skirting /dado etc, set and jointed in neat cement slurry and pointed with white cement mixed with pigment to match the shade of tile, fixed over and incl 10mm thick bedding layer in cement mortar 1:4 on concrete block wall surface complete all as specified. |
| 42 | Taking down or up steel tubing and connections incl cleaning for refixing or removal to store for 15 mm dia bore. |
| 43 | S&F for 25mm outer dia 3-layer PP-R P o l y p r o p y l e n e random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded p o l y p r o p y l e n e random fittings fixed complete to walls, ceilings or in floors etc. |
| 44 | Dismantling broken water tank of cap exc 500 ltr but n exc 1000 ltr. |
| 45 | S&F 1000 ltrs capacity Rotational moulded polythene water storage tanks (cylindrical vertical with closed top, two layers) hoisted and fixed in position complete all as specified and as directed by Engineer-in-Charge. |
| 46 | S&F in repair 15mm fancy type Bib taps, Chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed |
| 47 | Demolition of stone/boulders masonry, laid dry complete all as specified. |
| 48 | Demolition of stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 49 | M&L for stone masonry Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4, complete all as specified. |
| 50 | M&L for stone masonry Walling of random rubble, uncoursed, well bonded, and solidly heartd laid dry as directed and as specified. |
| 51 | Demolition of Reinforced Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) (reinforcement cut as required to facilitate demolition). |
| 52 | Use & waste formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick with flat rough finished surfaces of concrete, complete all as specifed and directed by Engr-in-charge. |
| 53 | M&L for RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams, and columns in floors, roofs complete all as specified and directed by Engr-in-charge. |
| 54 | M&L for cement concrete 1:4:8 type D2 (using 40mm graded crushed stone aggregate ) in foundation, filling and mass concrete complete all as specified and directed by Engr-in-charge. |
| 55 | M&L for Precast reinforced cement concrete, type B-1, 1:2:4 (Using 20mm graded crushed stone aggregate) as in manhole cover set in cement mortar 1:4, compete all as specified and directed. |
| 56 | TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 57 | Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of internal dia 75-100mm incl any earth work and demolition of PCC complete all as specified and directed. |
| 58 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor of 110mm bore pipe complete all as specified and directed by Engr-in-charge |
| 59 | S&F for 110 mm bore PVC (SWR) bends any radius. |
| 60 | PVC (SWR) Vent cowl of 110mm bore, complete all as specified as directed. |
| 61 | PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or floor of 75mm bore pipe complete all as specified and directed by Engr-in-charge |
| 62 | PVC (SWR) floor trap of 75mm plain with grating including jointing with solvent cement |
| 63 | M&L for 100mm thick cement concrete 1:3:6 type C2 bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested. |
| 64 | S&F BALL VALVE PTMT 25mm dia. |
| 65 | Demolition of Stone slabs and tiles of any description laid, bedded and pointed in any mortar or thickness in floors, aprons etc. |
| 66 | M&L for 20mm thick Granite (of any type) tiles machine cut, bedded including Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying finishes and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete. |
| 67 | S&F in repair Stainless steel sink, 1.00mm thick for kitchen or laboratory, with plug, waste pipe, washers, including cantilever cast iron brackets, connecting union etc.overall size 495mm x 420mm with bowl size 410mm x 330mm x 160mm. |
| 68 | M&L for fix in repair 18/19mm thick Particle board, medium density, flat pressed,single layer type or three layer type with BWR type adhesive, fixed with nails to timber frame work. |
| 69 | M&L for 0.9mm thick, Decorative laminate type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions. |
| 70 | S&F in repair 75mm Butt hinges, cast brass, with mild steel hinge pin, bright polished and fixed, type B-12. |
| 71 | Excavating in trenches ,n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard /Dense Soil complete all as specified. |
| 72 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm. in hard / dense soil. |
| 73 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. |
| 74 | Taking down carefully aluminium/Copper point wiring light, fan socket or power complete fitting such as switches, ceiling rose, fan regulator, socket including light fitting etc complete with /PVC /MS conduit and T/W battern / casing caping and all as specified and as directed by Engineer-in-Charge. |
| 75 | Taking out old unsv Service wiring / Sub main wire of any size/make/ type etc from excavted tranches/ on pole passing through pipes etc from different locations complete all as specified and directed by the engr in charge. |
| 76 | Supply and laying or fixing or passing through pipe, 16 sq mm 2 core 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape in service connections all as directed by Enginee-in-Charge. |
| 77 | M&L for point wiring with PVC FRLS insulated single core cable of stranded copper conductors of size 1.5 sqmm, 1100 volt grade drawn in and including rigid PVC casing caping accessories lain on wall/ceiling surface and fixed with PVC saddles and back-plate and GI screws, including PVC insulated single core cable of stranded copper conductor of size 1.5 sqmm as earth continuous wire connected to common earth and PVC Board for housing like switches, sockets, fan regulators etc all as directed by Engineer-in-Charge for one light point/one fan point controlled by one switch. |
| 78 | All as per item No 77.00 above but for one 3 pin 5 amps socket outlet independent with cables 2.5 sqmm size |
| 79 | All as per item No 77.00 above but for one 3 pin 5 Amp socket outlet on same board with cables 2.5 sqmm size. |
| 80 | All as per item No 78.00 above but for but with conductor of size 4 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 4 sqmm PVC insulated stranded copper conductor cable complete all as specified and as directed by Engineer-in-Charge. |
| 81 | S&F Socket 2 in 1, 5 pin 5 Amp flush type complete all as specified and directed by Engr-in-Charge. |
| 82 | S&F Switch piano flush type 5 Amp, single pole, one way complete all as specified and directed by Engr-in-Charge. |
| 83 | S&F Switch socket combination 2 in 1, 3 pin, 5 Amp flush type complete all as specified and directed by Engr-in-Charge . |
| 84 | S&F Switch Socket Combination 2 in 1, 3 pin, 15/16 amp flush type Universal complete all as specified and directed by Engr-in-Charge . |
| 85 | M&L for ceiling rose surface Bakelite 65x50mm two to three terminal complete all as specified and as directed by Engr-in-Charge. |
| 86 | S & F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engr-in-Charge. |
| 87 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 10 watt, 2 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 88 | S&F basic all purpose surface and wall mounted LED batten with polycarbonate housing and integreted electronic driver of cap 20 watt, 4 feet long, with all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 89 | S&F in repair sheet metal powder coated versatile Double door SPN distribution board, 12 way suitable for MCB's fitted with copper bus bar rated 200amps, neutral link , earth bar and din rail suitable for use on 240 Volt, 50Hz all as directed by Engr-in-Charge. |
| 90 | M&L for MCB SPN 63 Amp, 240V with 10KA breaking capacity of 'C' series in distribution boards all as specified and directed. |
| 91 | S&F MCB SP 6-32 Amp with 10KA breaking capacity of 'C' series in distribution boards with all accessories complete all as per specified and as directed by Engr-in-Charge. |
| 92 | Dismantling and Taking down old u/s street / building sequrity Light fittings from poles, flood lights, post top lantern lights and garden lights for replacement with LED fittings all as specified and as directed by Engr-in-Charge. |
| 93 | Supply and fix in Repair LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete Specified and directed by Engr-in-Charge. |
| 94 | M&L for GI bracket 1.5 mtr long made out of GI pipe 40mm dia, light grade bend to suitable radius incl clamps nuts bolts washers incl painting with aluminum paint etc complete all as specified and directed by Engr in charge. |
| 95 | S&F air termination, single pointed, copper rod 12mm dia and 300mm long different locations / Bldg complete all as specified and directed by the Engr-in-Charge. |
| 96 | S&F test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw complete all as specified and directed by the Engineer-in-Charge. |
| 97 | S&F Galvanised earth lead wire 4.0mm dia for roof conductors and down conductors above ground complete all as specified and directed by the Engineer-in-Charge. |
| 98 | S&F Galvanised earth strip 25x4 mm for roof conductors and down conductors above ground complete all as specified and directed by the engr in charge. |
| 99 | Supply and fix or laying 32 mm light grade GI tubes in trenches/on wall/ poles/ structures as in repairs for road crossing/ for cable protection / fixing of pigmi lights etc, including necessary provision for cable / Strip entry if reqd in pigmi lights pole fixing with screws / clamp complete all as specified and directed by Engineer-in-Charge. |
| 100 | M & L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanised earth lead wire 4.0mm dia by means of bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified.m( DB & Ligtining Conductor) |
| 101 | M & L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanised ironstrip 25×4 mm as earthing lead by means of bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, GI strip laid in dia 40 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit (30X30X30cm) with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. |
| 102 | Supply and fix electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessoriessuch as safety valve, thermostate, NRV, connection piece etc. complete all as specified and directed by Engr-in-Charge. |
| 103 | Supply and fix exhaust fan made of steel body, AC single phase, 230V of size 300mm sweep with, blades, and frame and complete with louvers shutter, voltage 230V, 50 Hz RPM 1200, copper winding all as per specified and as directed by Engr-in-Charge. |
| 104 | Supply and fix exhaust fan made of steel body, AC single phase, 230V of size 450mm sweep with, blades, and frame and complete with louvers shutter, voltage 230V, 50 Hz RPM 1200, copper winding all as per specified and as directed by Engr-in-Charge. |
| 105 | Taking out old unserviceable underground cable of any size/ make/ type etc from excavated trenches/ on poles/ passing through pipes etc from different locations complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 4 core. |
| 107 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge. |
| 108 | Material and labour for un reinforced pre cast concrete cable cover class LV type I, flat size 250 mm x 150 mm x 40 mm. |
| 109 | Sand cushioning to under ground cable complete all as specified in clause 19.75 of SSR Part - I. |
| 110 | Dismantling and Taking down LT U/S panels incl all outgoing and incoming connections and making good the disturbed area from site all as specified and directed by Engineer-in-Charge. |
| 111 | M&L for Busbar chambers with 4 aluminium busbar strip of rating 400 Amp 6 way fixed on angle iron of size 40mm x40mm x5mm Including provision and supply of MCCB 4 pole 160 Amp capacity with connected to busbar complete all as specified and directed by Engineer in Charge. |
| 112 | M & L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt, connected to MS galvanized earh strip of size 32 x 6 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result all as specified. |
| 113 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs 61,558.00 and any other reduction if any from quoted amount. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysAug 06, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 6 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender