Tender For Special Repair To Bldg No Np-8 And 9 (Lpg Shed) At Certain Mil Unit Under Ge (S) Binnaguri
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling Asbestos cement (corrugated,semicorrugated, etc.) sheets in roof coverings complete all as specified. |
| 2 | M&L for pre-painted galvalume aluminium zinc coating GI based Corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering fixed with self tapping screws/J hooks as specified. |
| 3 | M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550mpa as in roof covering fixed with self tapping screws/J hooks as specified. |
| 4 | M&L for Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc complete all as specified |
| 5 | Dismantling of timber scantling 40 sq.cm and over in section in any position |
| 6 | Supply and fix steel work in trusses ,purlins posts and the like using tubular /square hollow sections inculding special shaped washer etc complete using ERW or induction butt welded tubes/SHS/ conforming to 1161-2014/ is 4923-1997 sespectively of grade St 240 complete all as specified |
| 7 | Dismantling floor hearth or wall tiling including cement mortar bedding (incl backing) removing serviceable tiles to store and rubbish off the premises. |
| 8 | M&L for glazed coloured ceramic tiles (350x450x7mm thick) on vertical surfaces such as skirting/dado set and jointed in neat cement slurry pointed in white or coloured cement to match over 15mm thick rendering in CM(1:4) all as specified |
| 9 | Taking down cement plaster any description on brick or stone wall etc including racking out joints hacking for key scrubbing down with water etc. |
| 10 | M&L for rendering 15mm thick on fair faces of brick or concrete surfaces in cement mortar (1:6) finished even & fair. |
| 11 | M&L for rendering 20mm thick in cement mortar 1:4 in two layers of 10mm each using WPC in finishing layer on brick or concrete surfaces finished even & fair (WPC for finishing layer will be paid seperately as supply only). |
| 12 | Supply only liquid water proofing compound. |
| 13 | M&L for prepartion of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer to wall surface complete all as specified |
| 14 | M&L applying two coats of weather proof exterior emulsion paint of standard, over a coat of white primer including preparation of new wall surfaces complete all as specified |
| 15 | M&L for 2mm thick wall care putty in two layers on old/new internal/external wall surfaces ( 1mm average thick each layer) etc complete to receive primer/paint etc complete all as specified |
| 16 | M&L for complete removal of existing treatment of old plastered surfaces of walls and applying two coats of oil bound distemper over a coat of primer including complete removal of existing treatment all as specified |
| 17 | M & L for complete removal of existing treatment and finishing the walls with Acrylic smooth exterior paint of required shade : New work (Two or more coats applied over and including priming coat of exterior primer |
| 18 | S&F in repair of factory made steel windows with side hung shutters openable type including friction/box type hinges steel handle and peg stay complete with glazing bars fixed to existiog opening and making good to match as per existing surfaces including taking out old/unserviceable steel windows. |
| 19 | S&F in repair factory made steel ventilator with top hung shutter including friction/ box type hinges ,steel peg stay complete including taking out old/unserviceable steel ventilator and making good to match as per existing surfaces etc complete all as specified |
| 20 | Dismantling wrought iron or mild steel work of any description not otherwise provided for truss etc complete all as specified |
| 21 | S&F steel, plain, black sheet 1.25 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bendingor turning up, mitred angles, etc. as require complete all as specified |
| 22 | S&F Framed work such as grills,gratings, etc with ends of bars shouldered and/or riveted,or forged into spikes; framedguard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 23 | M&L for applying two coats of synthetic enamel paint over a coat of red oxide primer including preparation of new steel surface over 10cm width or girth |
| 24 | M&L for applying two coats of synthetic enamel paint over including preparation of old steel surface over 10cm width or girth completye all as specified |
| 25 | S&Fof 4mm thick sheet glass panes ordinary quality n.exc 0.5sqm each fixed to steel frame complete with oil putty in square including steel pin. |
| 26 | Demolition of brick work built in cement mortar etc complete all as specified. |
| 27 | M&Lfly ash brick work with sub class 'B' brick straight or curved on plan exc 6 m mean radius built in CM 1:6 |
| 28 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified |
| 29 | M&L for providing 100mm thick PCC (1:3:6) type C2 using 40mm graded aggregate as in sub base of floor complete all as specified |
| 30 | M&L for providing 100mm thick PCC (1:2:4) type B2 using 40mm graded aggregate as in base of floor complete all as specified |
| 31 | M&L for applying evenly a tack coat over the surface @5 Kg per 10 Sqm (20/30 bitumen) and providing and laying 30 mm thick Mastic Asphalt on prepared surfaces strictly in accordance with IS 1195 of 1978 (as latest modified) with mastic (ie bitumen of grade 20/30) @8.98 Kg mixed stone dust ( lime stone powder with calcium value 80%0 @ 0.016 Cum and stone chipping of size 12.5 mm and 10 mm @ 0.0192 Cum and sand @ 0.008 Cum Per Sqm with bitumen of grade 20/30, and finally complete all as specified |
| 32 | M&L for 75mm thick PCC type C-2 (1:3:6) using 40 mm graded agg in plinth protection path/hardstanding finished cement concrete surfaces fair and even all as specified |
| 33 | Demolition of cement concrete (un-reinforced) of any description and in any position not otherwise specifically provided complete all as specified |
| 34 | M&L for 75 mm thick cement concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in path /steps laid with and incl use and waste of form work and finishing the surface even and rough to receive the topping layer or tiling complete all as specified . |
| 35 | Providing and laying 80mm thick factory made chamfered edge cement concrete paver block of M-40 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mmthick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size andpattern, finishing and sweeping extra sand; complete all as specified |
| 36 | M & L for PCC 1:2:4 type B-I ,(using 20 mm graded stone aggregate) as. in coping /benching to sides of foot path fininished fair and even including necessary formwork etc complete all as specified |
| 37 | Supply and install in repair Turbo Ventilator 24 Inch over CGI roof with 42 nos 4 mm thick SS 304 grade fins, self lubricated dual ball bearing, SS shaft, SS Bottom throat & top with all necessary rivets or screws as required, Polycarbonate base plate UV grade 2 mm thick with sealent designed according to roof profile including cutting of existing GI roof sheet as per site requirement for fixing Turbo ventilator including necessary T&P complete all as specified |
| 38 | Supply and fix Fire alarm control panel complying with BS EN 54 Single loop panel of capacity from 99 detectors & 99 modules upto 200 detector |
| 39 | Supply and fix Detectors Complying with and type certified to EN-45 Addressable type smoke detector Photoelectric / Optical with base with self built intelligence as per IS: 11360 |
| 40 | Supply and fix fire alarm sounders/sirens electronic type horizontal single stage continuous normal operation for at least 50 minutes with sound level 65 DB to 120DB measured at 1.5 meter with sound output variation of + 5 DB for 500 meter range. (one each Floor) |
| 41 | Supply and fix addressable manual call point break glass type with alarm LED complete. (one each floor) |
| 42 | Supply, laying & testing PVC insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (Heavy duty) with stranded copper conductor of size 1.5 sq mm ,3 core, 1100 Volts grade. including PVC conduit not less than 25 mm with all fitting & other accessories all as specified |
| 43 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 sq mm 2 core all fixing and connecting accessories such as cable lugs, cable glands, nut, bolts, complete all as specified |
| 44 | Excavation in trenches n.exc 1.5m wide and n.exc 1.5m in depth for foundation of poles/stays/cables etc and getting out in any type of soil. |
| 45 | Returning, filling in, including, spreading, levelling, watering and well ramming in layers n.exc 25cm. |
| 46 | Removing excavated material n.exc 50m and depositing were directed at a level n.exc. 1.5m above the starting level. |
| 47 | M&L for sand cushioning in cable trenches over & under the cable, with river washed coarse sand, as per standard practice with proper compaction complete all as specified (Punned thickness 18 cm shall be considered for payment as per para 19.75 of SSR Part-I) |
| 48 | Supply and laying for brick protection for protection of cable over sand cushioning cables inside the trench by using common brunt clay building bricks sub-class “B” old size brick and flat and width wise along the axis of the trench complete all as specified |
| 49 | M & L for horizontal boring across the existing road without disturbing the road surface for inserting GI pipe complete all as specified. Note :- (i) Removal of surplus soil shall be deemed to be include in the unit Rate. (ii) GI pipe will be measured and paid separately under relevant item of Sch 'A'. |
| 50 | Supply and fixing 40 mm dia GI tubing medium grade ISI marked laid in trenches / laid under floor for protection of cable including all fittings such as elbow, bends, etc and short length complete all as specified |
| 51 | S&F Sheet Metal Enclosure 240V, 10Amp Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10A, B series complete all as specified |
| 52 | M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washers including necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and salt PCC pit 1:3:6 type C1 using 20mm graded stone aggregate and pit cover of standerd material complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete including taking out the old one complete all as specified |
| 53 | M&L for air termination, single pointed aluminium rod 12 mm dia and 300 mm long with necessary fixing arrangement on roof including taking down old one complete all as specified |
| 54 | M&L for test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm, drilled and screwed copper/aluminium bi-metal strip including 3 Nos 8 mm dia 25 mm long hex head screw including taking down old one complete all as specified |
| 55 | M&L Aluminium stip 25 x 3.15 mm fixed on and including saddles, pcc, pvc insulators and fixing screws etc. for roof conductors and down conductors including taking down old unsv strip. |
| 56 | S&F galvanised iron strip of size 32 x 6 mm buried in ground or fixed on wall mounted on suitable sized porcelain insulators ( on floor and wall only) including cutting cavities for fixing of porcelain insulators and finishing with cement plaster on wall /floors and connected to test point including bending, jointing at test points with GI nuts, bolts, with lead washers, jointing strips at all joints incl. making good the disturbed surfaces including taking down old one complete |
| 57 | Supply and laid GI Pipe medium grade complete including fttings 40 mm dia including taking down old one complete |
| 58 | Earthing complete with galvanised steel earth plate electrode 60 cm × 60cm × 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth strip 32x6 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including taking down the old one complete all as specified Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 29, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 12 daysJul 31, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 14 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender