Housing Urban and Rular Development Local Bodies Closing in 7 days TDR #56487178

Tender For Development Of Land At Transport Traders, Ifc Narela.Sub Head :C/O Surface Parking At Plot No.1, 2, 3, 4(Left Out Part) And Near Public Toilets Of Transport Traders, Ifc, Narela.

Issued by Local Bodies · Delhi, Delhi
Tender Value
10.26 Crore
Estimated cost
Bid Submission
29 Jul 2026
7 days left
EMD
20.26 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Development Of Land At Transport Traders, Ifc Narela.Sub Head :C/O Surface Parking At Plot No.1, 2, 3, 4(Left Out Part) And Near Public Toilets Of Transport Traders, Ifc, Narela.

BOQ

Name of Work:- D/o Land at Transport Traders, IFC Narela.Sub Head :C/o Surface Parking at Plot no.1, 2, 3, 4(left out part) and near Public Toilets of Transport Traders, IFC, Narela.
Sl. No. Item Description
1Excavating in soil/earth with hydraulic excavator i/c cutting and loading in tippers , transporting and dumping it to the embankment/subgrade location with all lifts and leads upto 5 km.
2Construction of soil Sub Grade with dumped earth at site by dressing to camber and consolidating with motor grader, road roller of 8 to 12 tonne capacity,sprinkling water etc. to achieve the compaction under OMC to give Maximum dry density (proctor density) as per specification including making good the undulations and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres.
3Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge. (a) With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
4(b)With material conforming to Grade-III (size range 26.5 mm to 0.075 mm ) having CBR Value-20
5Providing, laying, spreading and compacting graded stone aggregate (size range 53 mm to 0.075 mm ) to wet mix macadam (WMM) specification including premixing the material with water at OMC in for all leads & lifts, laying in uniform layers with mechanical paver finisher in sub- base / base course on well prepared surface and compacting with vibratory roller of 8 to 10 tonne capacity to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge.
6Construction of dry lean cement concrete sub base over a prepared subgrade with coarse and fine aggregate conforming to IS:383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per specifications, cement content not to be less than 150 Kg/cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, for all leads & lifts, laid with a mechanical paver, compacting with 8-10 tonne vibratory roller, finishing and curing etc. complete as per direction of Engineer-in- charge.
7Providing and laying C.C. pavement of mix M-30 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator, vacuum dewatering process and finally finished by floating, brooming with wire brush etc. including levelling to required slope/camber, finishing with required texture, providing tie bars wherever required, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per specification and direction of Engineer-in-charge (Item of shuttering work, joint fillers, sealants, tie bars to be paid separately).
8Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. Complete all as per direction of Engineer-in-Charge. (a) 60 mm thick C.C. paver block of M-35 grade with approved colour, design and pattern.
9Providing and laying 100 mm thick factory made cement concrete interlocking paver block of M-40 grade in heavy traffic parking area, made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge
10Providing and laying Dense Graded Bituminous Macadam using crushed stone aggregates of specified grading, premixed with bituminous binder and filler, transporting the hot mix to work site by tippers, laying with paver finisher equipped with electronic sensor to the required grade, level and alignment and rolling with smooth wheeled, vibratory and tandem rollers as per specifications to achieve the desired compaction and density, complete as per specification’s and directions of Engineer-in-Charge. (a) 50 to 100 mm average compacted thickness with bitumen of grade VG-30 @ 5% (percentage by weight of total mix) and lime filler @ 2% (percentage by weight of Aggregate) prepared in Batch Type Hot Mix Plant of 100-120 TPH capacity.
11Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick conforming to the relevant IS code on the top surface of dry lean concrete(DLC) below PQC as per direction of Engineer-in-charge
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.
13Providing and laying 60 mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.
14Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in- charge (length of finished kerb edging shall be measured to calculate volume for payment). (Precast C.C. kerb stone shall be approved byEngineer-in-charge).
15Centering and shuttering including strutting, propping etc. and removal of form for (a)Foundations, footings, bases of columns, etc. for mass concrete
16(b)Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
17Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge. (a) Providing and filling in position rubberized bitumen hot sealing compound for sealing of expansion joints in roads / pavements all complete as per direction of the Engineer-in-Charge
18Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: All works upto plinth level (a) Concrete of M25 grade with minimum cement content of 330 kg /cum
19(b)Concrete of M30 grade with minimum cement content of 350 kg /cum
20Providing and applying 2.5 mm thick road marking strips (retro- reflective) of specified shade/ colour using hot thermoplastic material by fully/ semi automatic thermoplastic paint applicator machine fitted with profile shoe, glass beads dispenser, propane tank heater and profile shoe heater, driven by experienced operator on road surface including cost of material, labour, T&P, cleaning the road surface of all dirt, seals, oil, grease and foreign material etc. complete as per direction of Engineer-in-charge and accordance with applicable specifications.
21Constructing brick masonry road gully chamber 45x45x77.5 cm with bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with precast R.C.C. vertical grating complete as per standard design : (a) With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
22Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
23Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : (a) Two or more coats on new work
24Providing and applying tack coat using bitumen emulsion conforming to IS:8887, using emulsion pressure distributer including preparing the surface & cleaning with mechanical broom. With medium setting bitumen emulsion (a) On W.B.M / W.M.M. @ 0.4kg/sqm
25Total = 10,56,33,988.40
26Rate after applying correction factor(0.973) on account of modified analysis of rate (as per office memorandum issued by cpwd vide File No.158/SE(TAS)/GST/2024/02-E dated 08/08/2024 = 10,27,81,870.71
27Add cost index @(-0.09%)=92503.68 Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56487178
AUTHORITY Local Bodies
TENDER VALUE 10.26 Crore
LAST DATE 29-07-2026
Authority
Authority Name Delhi Development Authority
Work Description Tender for Development Of Land At Transport Traders, Ifc Narela.Sub Head :C/O Surface Parking At Plot No.1, 2, 3, 4(Left Out Part) And Near Public Toilets Of Transport Traders, Ifc, Narela.
Basic Detail
Tender No 01/EE/NPD-7/DDA/2026-27
Bidding Type Tender
Location
City Delhi
State Delhi
Key Dates
Publish Date 16 Jul 2026
Submission Date 29 Jul 2026
Open Date 30 Jul 2026
Finance
Tender Value 10.26 Crore
Tender Fee Ref. Documents
EMD 20.26 Lakhs
Exemption Not Available
Document List
BOQ_964353.xls
e101fa44-440f-4eed-9cfa-4b6ebc4b9d01.html
NIT.pdf
NIT01.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 16, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 29, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 7 days
Jul 30, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 8 days

Tender Documents

Download All (ZIP) ↓
xls

BOQ_964353.xls

html

e101fa44-440f-4eed-9cfa-4b6ebc4b9d01.html

pdf

NIT.pdf

pdf

NIT01.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders