Tender for Arm Of Residential Buildings, Shekhawat Complex, Type-Ii, Iii & Iv At Nsg C Manesar For The Year 2026-27 (Sh:Electrical Maintenance)
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ /HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS / HFFR PVC insulated copper conductor single core cable etc. as required. |
| 2 | Group A |
| 3 | Group B |
| 4 | Group C |
| 5 | Wiring for twin control light point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required. |
| 6 | Group C ( non-residential buildings such as offices, hospitals, laboratories) |
| 7 | Wiring for light/ power plug with 2X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS / HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 8 | Wiring for light/ power plug with 4X4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 Nos 4 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable for loop earthing as required. |
| 9 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS/ HFFR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. |
| 10 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 11 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 12 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 13 | 2 X 10 sq. mm + 1 X 6 sq. mm earth wire |
| 14 | 4 X 4 sq. mm + 2 X 4 sq. mm earth wire |
| 15 | 4 X 6 sq. mm + 2 X 6 sq. mm earth wire |
| 16 | 4 X 10 sq. mm + 2 X 6 sq. mm earth wire |
| 17 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/recessed steel/PVC conduit including dismantling as required. |
| 18 | Group A |
| 19 | Group B |
| 20 | Group C |
| 21 | Rewiring for twin control light point with 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS/ HFFR PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. |
| 22 | Supplying and drawing following size of FRLS/ HFFR PVC insulated copper conductor single core cable in the existing surface/ recessed steel/ PVC conduit as required |
| 23 | 1 x 1.5 sq. mm |
| 24 | 2 x 1.5 sq. mm |
| 25 | 3 x 1.5 sq. mm |
| 26 | 4 x 1.5 sq. mm |
| 27 | 5 x 1.5 sq. mm |
| 28 | 6 x 1.5 sq. mm |
| 29 | 9 x 1.5 sq. mm |
| 30 | 2 x 4 sq. mm |
| 31 | 3 x 4 sq. mm |
| 32 | 4 x 4 sq. mm |
| 33 | 6 x 4 sq. mm |
| 34 | 3 x 6 sq. mm |
| 35 | Supplying and drawing following pair 0.5 mm dia FRLS/ HFFR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required |
| 36 | 1 Pair |
| 37 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 38 | Extra for fixing the louvers/ shutters complete with frame for an exhaust fan of all sizes. |
| 39 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 40 | 20 mm |
| 41 | 25 mm |
| 42 | 32 mm |
| 43 | 40 mm |
| 44 | 50 mm |
| 45 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. |
| 46 | 5/6 A switch |
| 47 | 2 way 5/6 A switch |
| 48 | 15/16 A switch |
| 49 | 3 pin 5/6 A socket outlet |
| 50 | 6 pin 15/16 A socket outlet |
| 51 | Telephone socket outlet |
| 52 | TV antenna socket outlet |
| 53 | Bell push |
| 54 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 55 | 5/6 A switch |
| 56 | 2 way 5/6 A switch |
| 57 | 15/16 A switch |
| 58 | 3 pin 5/6 A socket outlet |
| 59 | 6 pin 15/16 A socket outlet |
| 60 | Telephone socket outlet |
| 61 | TV antenna socket outlet |
| 62 | Bell push |
| 63 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 64 | Supplying and fixing modular 20 A Motor starter on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 65 | Providing and fixing fly proof stainless steel grade 304 wire gauge, to exhaust fan openings on the outer wall using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia. 0.50 mm, all complete with 2nd class teak wood beading 25X19 mm. |
| 66 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 67 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 68 | 1 or 2 Module (75mmX75mm) |
| 69 | 3 Module (100mmX75mm) |
| 70 | 4 Module (125mmX75mm |
| 71 | 6 Module (200mmX75mm) |
| 72 | 8 Module (125mmX125mm) |
| 73 | 12 Module (200mmX150mm) |
| 74 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 75 | 1 or 2 Module |
| 76 | 3 Module |
| 77 | 4 Module |
| 78 | 6 Module |
| 79 | 8 Module |
| 80 | 12 Module |
| 81 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 82 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 83 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 84 | Installation, Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. |
| 85 | Supplying and fixing Ding Dong Door Bell, suitable for single phase, 230 V, complete as required. |
| 86 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin flat flexible, FRLS/HFFR PVC insulated, copper conductor cable, in PVC sleeve of suitable size on the floor/ wall, or side of the table/ door etc. as required. |
| 87 | Providing and fixing plain 16/0.20mm (0.50sqmm) twin circular flexible FRLS/ HFFR PVC insulated, PVC sheathed copper conductor cable direct on the wall with PVC clips etc. as required. |
| 88 | Installation, Testing and Commissioning of pre-wired, fluorescent fitting / compact fluorescent/ LED fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS/HFFR PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 89 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FRLS/ HFFR PVC insulated, copper conductor, single core cable etc. as required. |
| 90 | Installation, Testing and Commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS/ HFFR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. |
| 91 | Supplying and fixing extra down rod of 10 cm length G.I. pipe ,15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 92 | Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as required. (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored) |
| 93 | Installation, Testing and Commissioning of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. |
| 94 | Upto 450 mm sweep |
| 95 | Supplying and fixing Plug top following rating including connection etc. as required. |
| 96 | 16 A, three pin, Plug top ISI marked |
| 97 | 6 A, three pin, Plug top ISI marked |
| 98 | Supplying, drawing, Installation, Testing and commissioning of CAT6 UTP LSZH 23AWG Twisted Pair Cable in existing conduit/ on surface, Category 6 Unshielded Twisted Pair, 4 pair should be complied as per UL/ETL verification program for compliance with ANSI/TIA-568.2-D standard. Outer diameter should be in the range of 6.1mm nominal with Operating Temperature Range : -5° to +60°C, Bending Radius : < 4 X Cable Diameter at –5°C ± 1°C and Pulling Force : 11.5Kg etc. complete as required. |
| 99 | 1 run of cable |
| 100 | Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid copper cable in existing conduit/ on surface, U/FTP, LSZH, Non- Plenum, Horizontal (solid) Cable suitable for high speed data networking application supporting upto 10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with color coded insulation for easy identification should have FLAME PROPERTIES i.e. Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable should have been tested and verified by UL/ ETL etc.complete as required. |
| 101 | 1 run of cable |
| 102 | 2 Run of cable |
| 103 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS/ HFFR PVC insulated copper conductor single core cable etc. as required. |
| 104 | Group A |
| 105 | Group B |
| 106 | Group C |
| 107 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2 Nos. 3 pin 5/6 A modular socket outlet and 2 Nos. 5/6 A modular switch, connections etc. as required. |
| 108 | Supplying & fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, \\"C\\" curve including connections, painting etc. as required. |
| 109 | Supply and installation of 400 mm sweep, 220 V, wall mounted fan along with speed regulator unit for speed control, on the existing wall, including connection, testing, commissioning etc. as required. (Make: Crompton/Havells/Orient/Usha/Bajaj/Almonard) |
| 110 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 111 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, Ics=100% Icu and Operational Voltage 690V etc. as required. |
| 112 | 100 A, 16 KA/ 25KA TPMCCB |
| 113 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 114 | 6 way , Double door |
| 115 | 8 way , Double door |
| 116 | 12 way , Double door |
| 117 | 16 way, Double door |
| 118 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 119 | 4 way (8 + 12), Double door |
| 120 | 6 way (8 + 18), Double door |
| 121 | 8 way (8 + 24), Double door |
| 122 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 123 | Single pole |
| 124 | Double pole |
| 125 | Triple pole and neutral |
| 126 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 127 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 128 | Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 129 | Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\" curve DP MCB complete with connections, testing and commissioning etc. as required. |
| 130 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \\"C\\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 131 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following single pole and neutral, sheet steel, MCB distribution board, 240 Volts, on surface/ recess, complete with testing and commissioning etc. as required. |
| 132 | For 6 way, Double door SPN MCBDB |
| 133 | For 8 way, Double door SPN MCBDB |
| 134 | For 10 way/ 12 way, Double door SPN MCBDB |
| 135 | For 14 way/16 way, Double door SPN MCBDB |
| 136 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete with testing and commissioning etc.as required. (L&T /Legrand /ABB /Schneider/Siemens.) |
| 137 | For 4 way, Double door TPN MCBDB |
| 138 | For 6 way, Double door TPN MCBDB |
| 139 | For 8 way, Double door TPN MCBDB |
| 140 | Providing and fixing 16 mm M.S. Fan clamps of standard shape and size in existing R.C.C. slab, including cutting chase, anchoring clamp to reinforcement bar, including cleaning, refilling, making good the chase with matching concrete, plastering and painting the exposed portion of the clamps complete. |
| 141 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 142 | Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling etc as required. |
| 143 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 144 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. |
| 145 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 146 | Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclo sure with cover plate having locking arrangement and wa tering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 147 | Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 148 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 149 | Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminium alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, suitable for operation with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise= 75°C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply, Ceiling Fan compliant to IS 374:2019 fan i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required. |
| 150 | 900mm, service value ≥ 5.1 CM/Min/Watt, air delivery 130 CM/Min (Minimum) |
| 151 | 1200mm, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) |
| 152 | 1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) |
| 153 | Supplying and fixing 3 mm thick phenolic laminated sheet cover on existing switch Box / metal box with Al. Alloy/ cadmium/ zinc plated screws and washers, including cutting the laminated sheet to required shape and size etc., complete as required. |
| 154 | Supply and installation of 150 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 270 CMH and a power consumption not exceeding 28 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 155 | Supply and installation of 200 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 500 CMH and a power consumption not exceeding 30 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 156 | Supply and installation of 250 mm sweep PVC exhaust fan with louver shutter, having a minimum air delivery of 750 CMH and a power consumption not exceeding 40 watts, in the existing opening, including making good the damage, connections, testing, and commissioning, etc., complete as required, with a minimum two-year manufacturer's warranty. (Make: Havells / Crompton/ Orient / Usha / atomberg / Almonard) |
| 157 | Supplying and installation of 380 mm sweep, 1400 RPM heavy-duty, single phase, metallic exhaust fan Conforming to IS:2312 -1967 in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Havells Turbo force Heavy Duty Exhaust Fan or with similar specifications C&G / Orient / Usha / Almonard) |
| 158 | Supplying and installation of 225/ 230 mm sweep, single phase, metallic exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. (Havells Ventil Air or with similar specifications C&G / Orient / Usha / Almonard) |
| 159 | Cutting holes of required size in brick masonry wall for fixing of exhaust fan including providing and fixing 160 mm dia PVC pipe and making good the same etc. complete as per direction of Engineer-in-charge. |
| 160 | Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F. ≥ 0.95, IP20, CRI ≥ 80 , Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 161 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C).Powder coated die cast / Extruded aluminium Body (Thickness ≥ 1.20 mm) |
| 162 | 18- 22 watt |
| 163 | 40 watt |
| 164 | Supply, installation, testing, and commissioning of integrated LED Batten luminaire, with a minimum system lumen output of 1000 lumen and with a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature 5500K - 6500 K, Average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, electronic driver, diffuser, directly on the ceiling/wall, including connections, earthing, etc. as required. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. |
| 165 | Supply, installation, testing, and commissioning of LED bulkhead fittings with IP 66 ingress protection, with a minimum system lumen output of 1000 lumens and a minimum system luminous efficacy of 100 lm/W, made of aluminium housing having a colour temperature of 5500K–6500 K, average life L70B50: 50000 hours, suitable for operation on 140-270V, 1Φ, 50Hz AC supply system, complete with all accessories, diffuser, electronic driver, etc. as required directly on the wall, including connections, etc. as required |
| 166 | Supplying, installation, Testing & Commissioning of LED Recessed/surface Down lighter (Round / square/ Rectangular) SMD type of following body material with PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI ≥80 , UGR (Unified Glare Rating) ≤ 19 Flicker free (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends, as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard. |
| 167 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq.mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted.Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C) Powder coated die cast /Extruded aluminium Body including trim. |
| 168 | 12 - 15 watt |
| 169 | 18 watt |
| 170 | Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following body material and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F≥0.95, IP20, CRI ≥80, UGR (Unified Glare Rating) ≤ 19, Flicker free, (flicker should be below 5 %), life time (LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard.. |
| 171 | Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. Complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135 lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminium housing such that LED junction temperature shall not rise above 90°C). Powder Coated CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 172 | CRCA Sheet Body (Thickness ≥ 0.50 mm) |
| 173 | 36 watt |
| 174 | Supply, installation, testing, and commissioning of outdoor type 3-watt IP 65 LED foot light/ step light in Die cast aluminium housing and Polycarbonate diffuser, complete with connection, etc., as required. (Jaquar LFTL01S003XW or similar in Philips / Wipro /LT/ Havells) |
| 175 | Rewinding of following size ceiling fan / exhaust fan/ Wall fan motor including complete removal of existing burnt out winding and rewinding of the fan with suitable size enameled copper wire, including sleeving, suitable insulation materials, varnishing etc., complete with dismantling and reassembling after repair, including connection testing etc. as required. Removed winding wire shall be retained by the contractor and suitably credited with its value and net value to be quoted. |
| 176 | 1200mm Sweep ceiling fan |
| 177 | 1400mm Sweep ceiling fan |
| 178 | Wall Fan upto 400 mm |
| 179 | Rewinding of stator winding of following size exhaust fans with suitable size enameled copper wire (as per manufacturer specification) including slaving of stator suitable insulation materials ie “E” class varnish complete with dismantling and reassembling after repair i/c connection testing etc as required (Brunt copper wire will be retained by the contractor). |
| 180 | 300mm / 380 mm exhaust fan |
| 181 | 450 mm exhaust fan |
| 182 | Providing and replacing ball bearing in following size ceiling fan/exhaust fan, including removing old ball-bearing, installing new ball bearing and testing the fan, etc., as required. (Scrap material will be retained by the contractor). (Both side shield ball bearing of SKF/ NBC /TATA ) |
| 183 | 1200mm Sweep ceiling fan. |
| 184 | 1400mm Sweep ceiling fan. |
| 185 | 300mm/ 380 mm exhaust fan |
| 186 | 450 mm exhaust fan. |
| 187 | 600 mm exhaust fan. |
| 188 | Providing and replacing 2.5 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 189 | Providing and replacing the 4 MFD fan capacitor in the ceiling fan/exhaust fan/wall fan, including connection and testing, etc., as required. (The old capacitor will be retained by the contractor). |
| 190 | Reconditioning of the oversized bush /bearing housing to a suitable ball bearing in the ceiling fan/ exhaust fan/ wall-mounted fans as required and assembling and testing of the fan after repair. All the scrap material should be retained by the contractor. |
| 191 | Providing and replacing the worn-out M.S. shaft of the exhaust fan /wall fan with a suitable size new shaft etc., as required, including removing the old shaft, installing the new shaft, and testing the fan. All the scrap material should be retained by the contractor. |
| 192 | Dismantling of the existing switch accessories like switches, sockets, and MCBs, etc., as required. |
| 193 | Dismantling of the existing ceiling rose, holder, and wall bracket and depositing the same with the listing of materials in the store. |
| 194 | Dismantling of existing fluorescent fitting from ceiling/ wall including making good the damage to match the adjacent surface, etc., as required. |
| 195 | Dismantling of the existing ceiling fan/ exhaust fan of any size installed in the building and depositing it in the MMC store. |
| 196 | Dismantling of the existing recessed vertical type or horizontal type TPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 197 | Dismantling of the existing recessed SPN MCB distribution board of any size along with MCBs and other accessories, including making good the damage to match the adjacent surface, etc., as required. |
| 198 | Dismantling of the existing recessed switch board of light points/power points, power/light plug points/socket outlet metal boxes of any size, along with phenolic laminated sheet, switches, sockets, etc., making good the damage to match the adjacent surface, etc., as required. |
| 199 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Above 25 mm conduits. |
| 200 | Dismantling wires from the following sizes, existing circuit/submain/power wiring conduits, complete as required. The length of the conduit from which the wires are removed will be measured for payment purposes, irrespective of the number of wires in it.Up to 25 mm conduit. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 16, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedJul 23, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
TodayJul 24, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 1 dayTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender