Tender For special Repairs/Replacement To 25 Street Lights To Solar Lights At Academisc Block And Residential Block And special Repair To Lt Panels And Connected Items At Rms Dholpur
Tender Value
25.71 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
13 days left
EMD
51420
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Bharatpur → Rajasthan
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for special Repairs/Replacement To 25 Street Lights To Solar Lights At Academisc Block And Residential Block And special Repair To Lt Panels And Connected Items At Rms Dholpur
BOQ
| Sl. No. | Item Description |
| 1 | Supply and fixing in replacement of Lithium base Energy efficient integrated Solar street light of 40watt in Aluminium Die casting body / FRP Bpdy , corrosion resistance,integrated PV panel Automatic dusk to input voltage 12.8V with suitable battery ,Driver efficiency .85%,PV module itself will be used to sense the ambient light to switch ON/OFF the Lamp, inbuilt MPPT charge controller, IP65,both PIR and fixed dimming available,4500 lumens (at full brightness) with grater than 150 lumen per watt,5700ANSI, cool white(5500K-6500K),CRI.70,moptical used, Metal core PCB,Low voltage cutoff ,high power LED,wide beam Angle(120 degree) LED Life 50000 hrs, weight less than 15 kg with GReen/Red indicator switch with suitable battery rating 12.8V-BIS standard complete all as specified.Make: Orient/Havells/Crompton Protections: Short circuit, overload,Reserve polarity and battery protection.Firm should provide vital parametres Test report from NABL accredited lab and should be of made in India with CE & ROHS complaint. |
| 2 | S & F street light GI bracket of 1.2 mtr long for building security / pole mount light made out of 40mm dia medium grade GI pipe bend to shape of 120 degree end welded at required including 02 Nos MS clamp of FL 40 x 6mm including nuts bolts & washers complete necessary fixing arrangements on pole and including Dismantling old U/S GI bracket of any size complete all as specified. |
| 3 | Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 300A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(c) MCCB 4 Pole,100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 02 No. (d) Digital type voltmeter of rating 0-500VDigital Type Ampere meter of Rating 0-200A(b) LED indicating Lamps R,Y,B-01 set |
| 4 | Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,250 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) On load changeover of capacity 200A 4Pole(c) Copper Busbar 400A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(d) MCCB 4 Pole,200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 02 No. (f) MCB TPN 32 Amp, 415 V C series - 01 Nos (g) Digital type voltmeter of rating 0-500VDigital Type Ampere meter of Rating 0-200A(h) LED Indicating Lamps R,Y,B - 01 Set |
| 5 | Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,63 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 100A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(c) MCCB 4 Pole,40A amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 05 No. (d) Digital type voltmeter of rating 0-500V(e)Digital Type Ampere meter of Rating 0-200A(f) LED Indicating Lamps R,Y,B - 01 Set |
| 6 | Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 300A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.(c) Onload Changeover 200A capacity 4POutgoing:-(d) MCCB 4 Pole,63A amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 03 No. (e) MCCB 4 Pole,40A amps ,415 Volt of breaking capacity not less than 16 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 02 No (f) Digital type voltmeter of rating 0-500V(g)Digital Type Ampere meter of Rating 0-200A(h) LED Indicating Lamps R,Y,B - 01 Set |
| 7 | Supply, installations, testing and commissioning factory made out door cubical type LT feeder pillar box dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 300A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set. (c) Digital type voltmeter of rating 0-500V(d) Digital Type Ampere meter of Rating 0-200A(e) LED indicating Lamps R,Y,B-01 set |
| 8 | Supply, installations, testing and commissioning factory made out door cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 300A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(c) MCCB 4 Pole,100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 03 No. (d) Digital type voltmeter of rating 0-500VDigital Type Ampere meter of Rating 0-200A(b) LED indicating Lamps R,Y,B-01 set |
| 9 | Supply, installations, testing and commissioning factory made indoor cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,250 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) On load changeover of capacity 200A 4Pole(c) Copper Busbar 400A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(d) MCCB 4 Pole, 63amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 05 No. (e) MCB SPN 40 Amp, 240 V C series - 01 Nos (f) Digital type voltmeter of rating 0-500V(g) Digital Type Ampere meter of Rating 0-200A(h) LED Indicating Lamps R,Y,B - 01 Set |
| 10 | Supply, installations, testing and commissioning factory made outdoor cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole,100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 150A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(c) MCB TP 40 Amp, 240 V C series - 01 Nos(d )MCB TPN 40 Amp, 415 V C series - 01 Nos (e) Digital type voltmeter of rating 0-500V(f) Digital Type Ampere meter of Rating 0-200A(g) LED Indicating Lamps R,Y,B - 01 Set(h) Astronomical timer switch analog dial type with suitable MCB and contactor of 40A(j) Reverse forward rotary type switch suitable for operation of motor 2HP |
| 11 | Supply, installations, testing and commissioning factory made outdoor cubical type LT panel board dust and vermin proof , free standing, floor mounting type mounted on and incluidng 1:3:6 PCC foundation as requried at site and of fabricated by 3.15 mm thick CRCA sheet over MS 40 X 40 X 5 mm thick angle iron frame of requried type for support with double door both sides open type with necessary locking arrangement with slopped roof on top duly painted with two coats of powder coated semense gray paint complete and having separate doors inside for accomodating all incomming / out going feeders of suitable sizes complete all as specified.Incoming:-(a) MCCB 4 Pole, 250 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 01 No.(b) Copper Busbar 400A current rating duly sleeve insulated for set of 3 phase, 4 wire system - 01 Set.Outgoing:-(c) MCCB 4 Pole,200 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 02 No. (d) MCCB 4 Pole,100 amps ,415 Volt of breaking capacity not less than 25 KA (Ics=100 % of Icu) adjustable TM Setting (Optium 2.0) - 02 No. (d )MCB TPN 40 Amp, 415 V C series - 02 Nos (e) LED Indicating Lamps R,Y,B - 01 Set (f) Astronomical timer switch analog dial type with suitable MCB and contactor of 40A (g) Multifunction digital meter suitable for showing ampere, L toL voltage, L to N voltage, PF ,Hz etc |
| 12 | M&L for renewl of copper Earthing complete with copper plate earth electrode 60 cm x 60 cm x 3.15mm, burried directly vertically in ground in a pit of depth not less than 2.25 metres below ground level with the top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including copper strip 20x3mm dia by means of copper bolts, nuts, check nuts and washers , strip protected by galvanised iron or steel pipe 40mm bore medium grade and connected to continuous earth test point. Watering pipe shall be 20mm bore GI medium grade including excavation and earth work in any type of soil, PCC pit and RCC cover complete all as specified. |
| 13 | M&L for renewl of Earthing complete with GI plate earth electrode 60 cm x 60 cm x 6mm, burried directly vertically in ground in a pit of depth not less than 2.25 metres below ground level with the top edge of earth plate at a depth not less than 1.5m below normal ground level connected to and including GI strip 32x6mm dia by means of copper bolts, nuts, check nuts and washers , strip protected by galvanised iron or steel pipe 40mm bore medium grade and connected to continuous earth test point. Watering pipe shall be 20mm bore GI medium grade including excavation and earth work in any type of soil, PCC pit and RCC cover complete all as specified and tested complete all as specified. |
| 14 | M&L for dismantling of Old unsv panels, disconnecting existing earthing, existing cables, breaking and removing old PCC in ecofriendly manner and disposed PCC to low ground area complete all as specified.Note:- All t&P required will be arranged by contractor.Contractor shall intimate to JE/Engg in charge before dismantling to get shut down. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender