Defence Statutory Bodies & Commissions/Committees Closing in 15 days TDR #56486881

Tender For Repair / Maintenance Of Certain Internal Electric Supply, Summer & Winter Appliances And Other Misc E/M Works At J-1 & J-2 Loc Under Ge (East) Jalandhar Cantt. (Tender Id No 2026_Mes_776519_1)

Issued by Statutory Bodies & Commissions/Committees · Jalandhar, Punjab
Tender Value
49.49 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
15 days left
EMD
98980
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Jalandhar → Punjab
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender for Repair / Maintenance Of Certain Internal Electric Supply, Summer & Winter Appliances And Other Misc E/M Works At J-1 & J-2 Loc Under Ge (East) Jalandhar Cantt. (Tender Id No 2026_Mes_776519_1)

BOQ

Name of Work:- Repair / Maint of certain internal electric supply, summer & winter appliances and other misc E/M works at J-1 & J-2 Loc under GE (East) Jalandhar Cantt. (Tender ID No 2026_MES_776519_1)
Sl. No. Item Description
1M&L for servicing of AC's split type of capacity 1 /1.5 / 2.0 TR inner & outer unit of any make, cleaning of outdoor condenser unit, indoor unit cooling coil, with chemical solution c-shine or equivalent and high pressure water jet pump, greasing to condenser fan, checking, tightning all electrical connections, washing of air filter, oiling and tightening of all nut, bolts, etc complete all as directed.Note:Necessary servicing of Indoor unit and outdoor unit will be carried out after taking down from the wall for prevention damage to periodical of walls and refixed at original position after servicing.At the time of services if get any leakage to refrigerant,refilling of refrigerant will be carried out by the contractor without any extra cost, complete , complete all as specified and as directed.
2M&L for replacement of compressor sealed unit suitable for air conditioner split type of capacity 1.5 TR in outdoor unit including taking out old unserviceable compressor, cleaning flushing, vaccumizing the system, recharging of gas/ refrigerant in adequate quantity, soldering/ brazing of suction, discharge and charging line, complete all as specified and as directed.Make:- Kirloskar/ LG/ Toshiba/ Hitachi/ Gujral/ Carrier/ Tecumseh/ Usha Shri Ram./ EMERSON COPELAND/ Mitsubishi
3Ditto all as per srl item No. 2.00 above but suitable for air conditioners of capacity 2.0 TR, complete all as specified and as directed.Note (for item No. 2.00 to 3.00) : Cost of refrigerant gas shall be deemed to be included in the item rate.
4Supply, replacement, connecting and testing of condenser blower motor with fan blades motor suitable for 1.5/2 TR split AC 240 volts single phase, complete all as specified and as directed.Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
5Supply, replacement, connecting and testing of indoor blower motor suitable for 1.5/2 TR split AC 240 volts single phase, complete all as specified and as directed.Make: Khaitan/ Universal/ CG./ Carrier/ Voltas/ Sidwal.
6Supply, replacement, connecting and testing of indoor blower suitable for 1.5/ 2 TR split AC 240 volts single phase, complete all as specified and as directed.
7S&F in replacement of temperature sensor as per existing type and size suitable for 1.5/2 TR split AC complete all as specified and as directed.
8S&F in replacement of starting/running capacitor conforming to IS specification suitable for 1.5/2 TR split AC complete all as specified and as directed.
9Material & labour/ charging of refrigerant gas in split type AC 1.5 Ton capacity including vaccumizing, leakage test and rectification of leakages etc , complete all as specified and as directed.
10Ditto all as per item No 9.00 above but of capacity 2.0 TR, complete all as specified and as directed.
11Repair/servicing of Electronic PCB Board for non inverter AC of any make , complete all as specified and as directed.
12Repair/servicing of Electronic PCB Board for inverter AC of any make , complete all as specified and as directed.
13S&F in replacement universal remote for any make/type of AC , complete all as specified and as directed.
14S&F in replacement flare nut of size as per existing including necessary flaring of copper tubing complete, complete all as specified and as directed.
15S&F in replacement of copper pipe for 1/2\\" to 5/8\\" including heavy duty insulation with wrapping with packing brown tape suitable for AC split type of capacity 1.5/2 TR including cutting and soldering, brazing etc complete all as specified and as directed.
16S&F in replacement PCB remote plate DC operation suitable for hot and cold operation of AC split type 1.5 /2 TR of any complete with remote , complete all as specified and as directed.
17S&F single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 amp 240 V 10 KA complete all as specified and as directed.
18S&F in replacement of copper pipe for 1/4\\" to 5/16\\" including heavy duty insulation with wrapping with packing brown tape suitable for AC split type of capacity 1.5/2 TR including cutting and soldering, brazing etc complete all as specified and as directed.
19M&L fo Top up of refrigent gas in spilt type AC Capacity 1.5 / 2.0 ton complete , complete all as specified and as directed. .
20S&F in replacement of heavy duty nylon insulation with wrapping with packing brown tape suitable for AC split type of capacity 1.5/2 TR including cutting and soldering, brazing of copper pipe if required complete all as specified and as directed.
21Supply and replace pvc drain pipe of standard size complete all as specified and as directed.
22S&F in repair condensor coil set made out of copper pipe and fins suitable for split AC of capacity 1.5/2 TR Ditto all as per existing type and size including cutting soldering and testing, complete all as specified and as directed.
23S&F in repair cooling coil set made out of copper pipe and fins suitable for split AC of capacity 1.5/2 TR Ditto all as per existing type and size including cutting soldering and testing, complete all as specified and as directed.
24S&F in repair capillary and filter suitable for AC Split type of capacity 1.5/2 TR, deep freezer, water cooler, refrigerator of suitable size including cutting, soldering, brazing etc complete all as specified and as directed.
25S&F in repair expansion valve suitable for AC Split type of capacity 1.5/2 TR including cutting, soldering, brazing etc complete all as specified and as directed.
26S&F in repair air filter suitable for split AC, complete all as specified and as directed.
27S&F in repair reversible valve 4 way with plunger AC 200/240 volts 50 c/s as per existing make and type suitable for AC split/window type of capacity 1.5 / 2.0TR including repair/ modification to remote plate, cutting, soldering, brazing complete including charging if gas required to maintain the required pressure complete all as specified and as directed.Note: Cost of all modification required including charges in wiring connections and gas cycle system are deemed to be included in item rate nothing shall be paid extra.
28M&L for servicing of voltage stabilizer of capacity 4/5 KVA by opening up and checking the fault, replacing necessary spares and make it functional , complete all as specified and as directed.
29Taking down unserviceable voltage stabilizer, S&F in replacement of voltage stabilizer copper wounded for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 270 V with output voltage stabilized at 230 V with of capacity 16 Amp rating min with digital dispaly complete all as directed by Engineer-in-charge.Note: Old UNSV stabilizer will be depsit in MES stroe yard for BER
30Ditto all as per item No. 29.00 above but for 12 Amp rating, complete all as specified and as directed.
31M&L PVC insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 1 sqmm, ISI marked complete all as specified and as directed.
32M&L PVC insulated and sheathed, flexible wire with multi stranded copper conductor wire of size 3 core, 1.5 sqmm, ISI marked complete all as specified and as directed.
33M&L in replacement PVC insulated and sheathed, round flexible wire with multi stranded copper conductor wire of size 3 core, 2.5 sqmm, ISI marked complete all as specified and as directed.
34Taking down old unserviceable sealed compressor and S&F of new compressor sealed unit suitable for water cooler 40 Ltrs capacity including cleaning, vaccumizing, gas charging of adequate quantity and testing on load complete all as specified and as directed.Make: USHA / Sriram /Emerson / Kirloskar/ Carrier/ Tecumshah.
35Ditto all as per description of Srl item No 34.00 above but sealed unit compressor suitable for water cooler capacity 80 Ltrs, complete all as specified and as directed.
36S&F in repair desert cooler stand made out of MS angle iron including cutting and welding, painting with two coat of synthetic enmel paint over a coat of red oxide primer all as directed.
37Supply and replacement of water tap brass CP with inner/outer threads push type or with rotary knob of size 15 mm dia as per existing type and size complete all as specified and as directed.
38Supply and replacement of water stop cock brass CP with inner/outer threads push type or with rotary knob of size 15 mm dia as per existing type and size complete all as specified and as directed.
39S&F in replacement of thermostat switch suitable for water coolers complete all as specified and as directed.Make : Danfoss/ Renutrol/ Indfoss or equivalent
40S&F in replacement of starting relay suitable for water coolers of capacity 40/80Ltr complete all as specified and as directed.Make :- Danfoss/Renutrol/ Indfoss or equivalent.
41S&F in replacement of starting/running capacitor suitable for water coolers 40/80Ltr complete all as specified and as directed.
42S&F in replacement of overload protector suitable for water cooler of any capacity complete all as specified and as directed.
43Taking down old and unserviceable sealed compressor and S&F new sealed compressor unit for refrigerator of capacity 415 Ltrs including cleaning, vaccumizing, gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge and charging line complete all as specified and as directed.
44Taking down old and unserviceable sealed compressor and S&F new sealed compressor unit for deep freezer of capacity 405 Ltrs including cleaning, vaccumizing, gas charging of adequate qty in the unit and soldering/ brazing of suction and discharge and charging line complete all as directed by Engineer-in-charge.
45Ditto all as per item No 44.00 above but for deep freezer of capacity 310 Ltrcomplete all as directed by Engineer-in-charge.
46S&F electronic PCB board of Refrigerator capacity 410 Ltrs as per existing type and size including testing, complete all as specified and as directed.
47S&F of starting relay with over load protector kit complete as per existing size and type complete , complete all as specified and as directed.
48S&F in replacement fan motor any sweep suitable to operative on AC, 220/240 volts, 50 c/s complete with frame square Ditto all as per existing size/type suitable for deep freezers or water cooler , complete all as specified and as directed.
49Taking down existing Split AC 1.5/2.0 TR indoor unit and out door unit complete by disconnecting refrigerent suction and discharge lines, opening nuts and bolts taking out brackets of indoor and outdoor unit from walls, taking out Voltage stabilizer from wall, reinstall in same place after necessary repair work or shifting to another loc in unit without damaging the AC'S , complete all as directed by Engineer-in-charge.
50S&F in replacement Brackets for fixing split AC 1.5/2.0 TR indoor and out door unit with walls made of MS duly powder coated factory made with bolts, nuts and washers and 04 Nos of fastners, complete all as specified and as directed.
51S&F in replacement Floor Stand for fixing split AC 1.5/2.0 TR out door unit made of MS duly powder coated factory made with bolts, nuts and washers and 04 Nos fastners complete all as specified and as directed.
52M&L for fabrication of tray made of GI sheet of size matching to split AC outdoor unit 1.5/ 2 Ton complete with necessary provn of drain and fixing on the oudoor unit stand, complete all as specified and as directed.
53M&L for refrigerant R-134a gas complete all as specified and as directed.
54S&F in replacement multifunction safety valve for geyser any capacity, complete all as specified and as directed.
55S&F in repair for PCB plate suitable for split type AC 1.5/ 2 TR of existing with remote complete , complete all as specified and as directed.
56M&L for service valve for split AC 1.5/2 ton, complete all as specified and as directed.Note for srl item No.2 to 56(a) The above mentioned items will be replaced based on day to day complaints except rewiring and no extra cost will payable for attending complaints. Contractor will quote the rate accordingly.(b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed electrician & helper will carry all T&P, live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor. (e) Contractor shall be responsible for collection of all ON LINE, off line/ telephonic complaints and handing over the same to complaint cell after rectification duly signed by user with details of stores fixed after attending/ completion of the job on the same day.(f) Contractor shall handover these items within 15 days to concerned JE incharge which will be issued for fixing on the basis of day to day complaints. The recovery of Rs 1500 per day shall be levied in case of default.
57Attending day to day complaints of summer/winter appliances diagnosing, rectification of fault, any petty repair required to restore the system including carrying out minor repairs such as changing small pieces of wires etc, carrying out repairs such as tightening of loosen electric connections, nuts, bolts screws in switches, sockets, switch board, changing of ACs heat mode to cool mode and vise versa etc., required to make the appliances functional during 0900 Hrs to 1700 Hrs by deploying electrician alongwith helper including necessary tools complete all as specified and as directed.(b) Number of complaints may vary day to day. Contractor shall quote his rates accordingly. (c) In case of failure on the part of contractor for attending complaints, a penalty shall be imposed and recovered as specified in Particular Specifications. (d) Contractor shall ensure that the deployed technician & helper will carry all T&P, functional and live mobile phone while on duty and will be on contact with JE/ Engineer-in-Charge without any extra cost payable to contractor. (e) Contractor shall be responsible for collection of all ON LINE, off line/ telephonic complaints and handing over the same to complaint cell after rectification duly signed by user with details of stores fixed after attending/ completion of the job on the same day.The payment of this item will be released only after recipt of all complaint slips.
58Supply and replacement of condenser of refrigerator suitable for 286 to 310 ltrs of existing make, complete all as specified and as directed.
59Supply and replacement of condenser of refrigerator suitable for 165 to 220 ltrs of existing make, complete all as specified and as directed. Please Enable Macros to View BoQ information
60Supply and replacement of condenser of refrigerator suitable for 165 to 220 ltrs of existing make, complete all as specified and as directed. Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56486881
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 49.49 Lakhs
LAST DATE 05-08-2026
Authority
Authority Name Military Engineer Services
Work Description Tender for Repair / Maintenance Of Certain Internal Electric Supply, Summer & Winter Appliances And Other Misc E/M Works At J-1 & J-2 Loc Under Ge (East) Jalandhar Cantt. (Tender Id No 2026_Mes_776519_1)
Basic Detail
Tender No GE/JULL/ET-43/2026-27
Bidding Type Tender
Location
City Jalandhar
State Punjab
Key Dates
Publish Date 15 Jul 2026
Submission Date 05 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 49.49 Lakhs
Tender Fee 500
EMD 98980
Exemption Available
Document List
47621046-1ade-4f2c-88d2-b74475fd8fa2.html
BOQ_872182.xls
Tender43.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 05, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 15 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 20 days

Tender Documents

Download All (ZIP) ↓
html

47621046-1ade-4f2c-88d2-b74475fd8fa2.html

xls

BOQ_872182.xls

pdf

Tender43.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders