Tender For Repair/Replacement And Maintenance Of Electrical Fittings/Fixture , Wiring Including , Meter Box, Mcb Dbs And Sub Main Wiring In Md Accn Of Offrs, Jcos And Ors At Pal Ur Mil Station Under Ge Pal Ur.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Aug 2026
18 days left
EMD
84000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Kangra → Himachal Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Repair/Replacement And Maintenance Of Electrical Fittings/Fixture , Wiring Including , Meter Box, Mcb Dbs And Sub Main Wiring In Md Accn Of Offrs, Jcos And Ors At Pal Ur Mil Station Under Ge Pal Ur.
BOQ
| Sl. No. | Item Description |
| 1 | Taking down old unsv copper/aluminium point wiring concealed / batten surface (light, fan, socket or power) complete, including fixture and fittings such as switches, sockets, ceiling roses, bell push, bell electric, lamp holder, bulk head fitting, pendants, regulators, sockets, light fitting and any type switch board wooden/iron, round block etc removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls, floors, etc complete all as specified and directed |
| 2 | Taking down un-serviceable DB of any size and capacity including MCB etc, and removing materials to store for keeping in safe custody or for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed. |
| 3 | Taking down un-serviceable sub main wiring of any type and any size from wall, ceiling etc. complete all as specified and directed. |
| 4 | M&L for replacement with 1.5 Sqmm single core multistranded copper conductor FRLS, PVC insulated (unsheathed) heavy duty cable including continuous earth wire of size 1.5 sqmm copper conductor multistrand FRLS, PVC insulated (unsheathed) drawn into and including concealed PVC rigid conduit medium grade ISI marked including pressed steel with existing colour terminated boxes of Modular white cover plate , GI sheet Metal flush Boxes of any way i.e. (1 to 8 way as per site requirement) for mounting switches, sockets, fan regulators etc for fixing one light/fan/bell point/fan/exhaust fan controlled by one 5/6 A switch and making good disturbed surfaces with CM (1:4) to match with the existing whitewash color surface complete all as specified and directed for the following:- (a) Wiring shall be done by using proper colour coding(b) Earth wire shall be of green colour (c) On RCC roof/ceiling PVC conduit shall be provided on surface with proper fixing clamps complete all as specified and directed. |
| 5 | Description all as per serial item No 04 above but one 5/6 pin socket outlet, 5 amps on the same board complete all as specified and directed. |
| 6 | Description all as per serial item No 04 above but one 5/6 pin socket outlet, 5 amps on independent board complete all as specified and directed. |
| 7 | Description all as per serial item No 04 above but for one 5 pin socket outlet 15 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed. |
| 8 | All as per the description of serial item no 4 above controlled by two 2-way switches, with cables 1.5sqmm size all as specified and directed |
| 9 | M&L for replacement point wiring with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor cable 1100 volts grade single core conforming to IS-694-1990 and including one run of continuous earth wire to common earth and connected to earth with 1.5 Sqmm PVC (FRLS-H) insulated unsheathed multi stranded copper conductor earth cable drawn in & incl PVC surface casing 'N' capping double lock type to be fixed with the help of rawal plugs & screws ind all fittings such as Tee, connector pieces, L-junction etc on joints including Modular white cover plate/galli, GI sheet Metal flush boxes of anyway (as per site requirement) for mounting switches, sockets, regulators etc for fixing one light/fan/bell point/fan/exhaust fan controlled by one 5/6 A switch and making goaud disturbed surfaces with CM (1:4) to match with the existing whitewash color surface complete all as specified and directed. Notes : (a) Wiring shall be done by using proper colour coding (b) Earth wire shall be of green colour. |
| 10 | Description all as per serial item No 9 above but 5/6 Amp socket outlet on same board complete all as specified and directed. |
| 11 | Description all as per serial item No 9 above but socket outlet 5/6 Amps independent board complete all as specified and directed. |
| 12 | Description all as per serial item No 9 above but for one 6 pin socket outlet 16 Amps on independent board with cables 2.5 sqmm size complete all as specified and directed. |
| 13 | All as per the description of serial item no 9 above controlled by two 2-way switches, with cables 1.5sqmm size all as specified and directed. |
| 14 | S&F Modular switch 1 way 6 A, 1 module, 240 volts ISI marked complete all as specified and directed. |
| 15 | S&F Modular switch 1 way 16 A, 1 module, 240 volts ISI marked complete all as specified and directed |
| 16 | S&F Modular Socket, 6A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed. |
| 17 | S&F Modular Switch 6A/16A - 2/3 pin combined 2 module, 240 volts ISI marked complete all as specified and directed. |
| 18 | S&F Modular Switch two way 6 Amp, one module 240 volts ISI marked complete all as specified and directed. |
| 19 | S&F Modular Bell Push 6A 1 Module, complete all as specified and directed. |
| 20 | S&F Modular Fan step regulator, 120W 1 module, 240 volts ISI marked complete all as specified and directed. |
| 21 | S&F in repair ceiling Rose surface type 3 terminal 65x20mm omplete all as specified and directed. |
| 22 | Supply & Fixing switch piano flush type single pole one way 6 A SP 230V complete all as specified and directed. |
| 23 | Supply & Fixing switch piano flush type single pole one way 16 A SP 230V complete all as specified and directed. |
| 24 | S&F in replacement socket outlet 2 in 1, 3 pin 6Amps flush type complete all as specified and directed. |
| 25 | S&F in replacement socket outlet 2 in 1 , 3 pin 16 Amps flush type complete all as specified and directed. |
| 26 | S&F of switch socket combination outlet 2 in 1 3 pin 6 Amp flush type complete all as specified and directed. |
| 27 | S&F of switch socket combination outlet 2 in 1 3 pin 6 and 16Amp flush type complete all as specified and directed. |
| 28 | S&F angle lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed. |
| 29 | S&F Ding Dong Bell AC 230 volt single pole complete all as specified and directed. |
| 30 | S&F in replacement of the sheet metal enclosure with socket plug top with MCB of a two pin and earth plug and a socket complete with one double pole MCB, 20 Amp, 240 volts ISI marked complete all as specified and directed. |
| 31 | Supply and fixing LED complete fitting including batten LED polycarbonate 18/20 Watt tubelight, use and throw type, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories, complete all as specified and directed. |
| 32 | Supply and fixing LED complete fitting including batten LED polycarbonate 10/12 Watt tubelight, use and throw type, appx 4 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories, complete all as specified and directed. |
| 33 | Supply and fixing LED complete fitting including batten LED polycarbonate 5/7 Watt tubelight, use and throw type, appx 2 feet long, environment friendly, including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories, complete all as specified and directed. |
| 34 | Supply and fixing LED tube light fitting invertor type 1 x 10 w , 230 volt ultra slim square profile LED lighting fixture with extruded polycarbonate 4 feet long, environment friendly, ebergy efficient ready to use including electric connection with using 2 core flexible copper conductor cable 23/0.00076 from ceiling rose to tube fitting, complete fitting with all accessories, complete all as specified and directed. |
| 35 | Supply and Fix FX LED Bulk Head 10W with pressure plastic housing with clear prismatic diffuser , high efficient LEDs IP66 complete all as specified and directed incl taking down old u/s bulk head complete all as specified and directed. |
| 36 | S & F Sheet metal enclosures, VTPN Distribution board 4 way 415 V, double door with 100A MCCB as incomer complete with rated bus bar and neutral link earthing fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note:- Distribution board and MCB's should be same make |
| 37 | S & F Sheet metal enclosures, VTPN Distribution board 4 way 415 V, double door with 125A MCCB as incomer complete with rated bus bar and neutral link earthing fixed flush in wall including chases wall for fixing DB and making good distributed wall surfaces to match with existing specification complete all as specified and directed. Note:- Distribution board and MCB's should be same make. |
| 38 | S & F in repairs factory made DB SPN 12 way double door with 200 Amps rated bus bar concealed in wall IP 42/43 protection, 240V for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash color/surfaces complete all as specified and directed Note: Distribution board and MCB's should be same make. |
| 39 | S & F in repairs factory made DB SPN 8 way double door with 200 Amps rated bus bar concealed in wall IP 42/43 protection, 240V for fixing MCB & making good to disturbed surfaces as well as matching with existing whitewash color/surfaces complete all as specified and directed Note: Distribution board and MCB's should be same make |
| 40 | S&F in replacement 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 Amp, in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 41 | S & F in replacement of SPN 40 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed |
| 42 | S & F in replacement of SPN 63 Amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) current carrying capacity in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 43 | S & F MCB TPN 63 Amp rating 415V, 10KA 'C' curve current carrying capacity complete with connection testing and commissioning complete all as specified and directed |
| 44 | M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC concealed conduit fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note: Wiring shall be done in proper colour coding. Note: Cutting chases on the wall wherever required is deemed to be included in unit rate quoted. |
| 45 | M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 6 Sq mm for phase and neutral and one run of 6.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC casing capping fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note: Wiring shall be done in proper colour coding Note: Cutting chases on the wall wherever required is deemed to be included in unit rate quoted. |
| 46 | M&L for sub main wiring with proper colour coding, insulated, unsheathed, multistranded, copper conductor FRLS, cable of 2 run 4 Sq mm for phase and neutral and one run of 4.0 Sq mm for earth wire unsheathed, multistranded, copper conductor FRLS, drawn through the medium grade ISI mark PVC casing capping fixed on wall. Two runs of cable for phase/neutral and one run of cable for earth will be measured and paid as one unit length complete all as specified and directed. Note: Wiring shall be done in proper colour coding. Note: Cutting chases on the wall wherever required is deemed to be included in unit rate quoted. |
| 47 | Supply and Fix in replacement LED Round Bollard light type 10 watt 230 volts AC outdoor type for 360 degree indirect light IP65 complete with impact and corrosion resistant complete with driver and lamp complete all as specified and directed. |
| 48 | Supply and Fix in replacement Recess mounted slim LED luminaire with drop down diffuser round /squre shape light 20W 230 volts AC corrosion resistent complete all as specified and directed. |
| 49 | S&F in replacement of 3mm thick backelite sheet (hylam) as sheet cover with PVC box of size 8\\"x10\\" for fixing switches, sockets & regulators etc. complete all as specified and directed |
| 50 | S&F in replacement of 3mm thick backelite sheet (hylam) as sheet cover with PVC box of size 8\\"x5\\" for fixing switches, sockets & regulators etc. complete all as specified and directed |
| 51 | S&F in replacement of 3mm thick backelite sheet (hylam) as sheet cover with PVC box of size 7\\"x4\\" for fixing switches, sockets & regulators etc. complete all as specified and directed |
| 52 | S&F in replacement of 3mm thick backelite sheet (hylam) as sheet cover with PVC box of size 4\\"x4\\" for fixing switches, sockets & regulators etc. complete all as specified and directed |
| 53 | S&F in replacement PVC flexible copper cable sheathed 3 core, 2.5sqmm, universal colour code, complete all as specified and directed by Engineer-in-charge. |
| 54 | M&L for PVC casing & caping of size (20x12)mm ISI marked suitable for electrical wiring complete all as specified and directed |
| 55 | M&L for PVC casing & caping of size (26x16)mm ISI marked suitable for electrical wiring complete all as specified and directed. |
| 56 | Disconnecting/ Taking down Exhaust fan of any sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting with existing color shade, oiling and greasing of bearing including refixing and making the conection and testing complete all as specified and directed. |
| 57 | Disconnecting/ Taking down ceiling fan of any sweep removing and cleaning the dust properly, painting with same colour good quality synthetic enemelled paint after preparing surface for painting with existing color shade, oiling and greasing of bearing including refixing and making the conection and testing complete all as specified. |
| 58 | S&F factory made CRCA sheet powder coated double door meter panel board 2mm thick, of size 100x100x20 cm, with Aluminium bus bar ,wall mounted type partially grouted in wall with locking arrangement, handle and making good disturbed surface as well as matching with existing whitewash color/surface and including provn of following and connection all as specified and directed :- a) MCCB TPN 63A, 415 Volts, C series-01Nos (incoming) b) MCB SPN, 32A, 230 Volts-05 Nos (Outgoing for each qtr and 1 common stair cae light point) c) Fixing only existing old energy meter including connection complete all as specified and directed. |
| 59 | S&F street light bracket made out of 32 mm dia GI light grade tubing not less than 1.5 Mtr long bend to shape including pole clamps made out of 40 x 5 iron strip and nut bolts and washers, complete all as specified. |
| 60 | Supply and fixing bldg LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed. |
| 61 | Material and labour for Earthing complete with galvanised iron earth plate electrode of size 600 x 600 x 6 mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI earthing wire of size 4 mm dia by means of GI bolts/nuts/washers and protected by 15 mm bore GI light grade pipe up to test point or upto main switch board fixing with 02 Nos nuts and bolts and protection pipe fixed with and including flat iron clamps, bolts, nuts and washers. Earth plate shall be surrounded by alternate packed layer 15 cm thick of charcoal or coke and common salt all around bottom and top , 20 mm bore GI medium grade pipe for watering and including funnel, wire mesh, PCC chamber pit made with PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) including necessary form work, excavation and earth work in any type of soil, returning filling and disposal of surplus soil to a distance not exceeding 50m, Pit cover 40mm thick made with RCC (1:2:4) type B1 (using 20 mm graded stone aggregate) with two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified & shown in electrical plate No. 3 of SSR 2009 (Part-I) complete all as specified and directed.Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) Protection pipe and GI earthing wire upto electric equipment from top of earth plate shall be included in the unit rate of this item. (iii) The earth testing arrangement should be done by the contractor as per direction of GE |
| 62 | Material and labour for GI tubing (light grade) with all fitting laid in trenches or along pole/bldg or under road crossing and protection pipe or fixed alongwith wall/pole with necessary clamp nut bolt and washer bore of pipe 40mm complete all as specified and directed. |
| 63 | S&F Single phase AC electronic tamper proof energy meter of rating 10 to 30 Amps, 50c/240 Volts with backlit LCD display ( measure and displays KWH, V, I, kW, PF, last month history KWH KWH MD in KW )with special feature like TOD tamper logging optical communication port, and display in absance of power accuracy class 1.0 confirm to IS 13379 as per GE specification with transprant hinge type box MAKE -L&T, HPL, Secure |
| 64 | S&F Three phase AC electronic tamper proof energy meter of rating 32 to 100 Amps, 50c/415 Volts with backlit LCD display ( measure and displays KWH, V, I, kW, PF, last month history KWH KWH MD in KW )with special feature like TOD tamper logging optical communication port, and display in absance of power accuracy class 1.0 confirm to IS 13379 as per GEspecification with transprant hinge type box MAKE -L&T, HPL, Secure Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 18 daysAug 12, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 25 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender