Tender For Welcome Maintenance Of Internal Water Supply Plumbing And Allied Works For Old Navy Nagar And New Navy Nagar And Rashi Area Under Ge (Nw) Navy Nagar, Colaba, Mumbai.
Tender Value
35 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
14 days left
EMD
70000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Mumbai → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Welcome Maintenance Of Internal Water Supply Plumbing And Allied Works For Old Navy Nagar And New Navy Nagar And Rashi Area Under Ge (Nw) Navy Nagar, Colaba, Mumbai.
BOQ
| Sl. No. | Item Description |
| 1 | Supply & fix in replacement of PVC(LLDPE) rectangular loft tank of net capacity 275 Ltr with gross capacity of tank at least 5% in excess of minimum net capacity including 03 Nos adopter with washer for inlet/outlet overflow pipe as per manufacturere s instruction and overall dimension as 995-1200mm length , 620-820mm with 285-485mm height , 300mm internal dia of hand hole,minimum wall thickness 2.75mm( weight of tank 11 Kgs) with lid cover complete all as specified and directed by Engineer-in- Charge. |
| 2 | Supply and fix in replacement PVC profile suitable for 275 ltr loft tank including fixing of aluminium channel around the profile complete all as specified and directed. |
| 3 | Supply, fixing and laying in repair/ replacement of CPVC pipes 15 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. |
| 4 | Supply, fixing and laying in repair/ replacement of CPVC pipes 20 mm nominal bore SDR 11 & Plain CPVC SDR 11 fittings such as nipple, union, socket, elbow, bends, tee, adopter e.t.c fixed to wall/floors/ceiling including work to be done up to 15 th floor in high rise buildings and low rise buildings in short piece/length all as specified and directed by Engineer-in-charge. |
| 5 | Supply and fixing in repair/ replacement of 15 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall or concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge |
| 6 | Supply and fixing in repair/ replacement of 20 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall or concealed pipe and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge |
| 7 | Supply and fixing in repair/ replacement of 25 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge |
| 8 | Supply and fixing in repair/ replacement of 40 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge |
| 9 | Supply and fixing in repair/ replacement of 50 mm bore internal steel water tubing, galvanised, Medium grade with all fittings such as nipple, union, socket, elbow, bends, fixed to wall including work to be done up to 15 th floor in high rise buildings in short piece/length, including breaking the existing brick wall for replacement of corroded GI pipe in/ on wall and making good the disturbed surfaces to match previous structure with complete all as specified and directed by Engineer-in-charge |
| 10 | Supply and fix in replacement bronze pressure reducing valve suitable for 25 mm bore GI pipe with diaphram cover, spring clamps, cast iron body scatting and adjustable screws and stop valve of chromium plated carbon steel strainer, screw of stain less steel for domestic water supply, suitable for inlet pressure as per IS-7939, including GI pipe connection as required, the work to be carried out from G+14 floor on plain wall with necessary bamboo scaffolding complete all as specified and directed by Engineer-in-Charge. |
| 11 | Supply and fix in repair/ replacement concealed CP cast copper alloy stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends suitable for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified . |
| 12 | Supply and fix in replacement angle cock for GI tubing 15 mm dia or 20 mm outer dia CPVC pipe including necessary fittings,clamp & saddles etc all as specified. |
| 13 | Supply and fix in repair/ replacement CP cast copper alloy stop cock fancy type, chrome plated, screwed down with crutch or butterfly handle suitable for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified . |
| 14 | Supply and fix in replacement CP cast copper alloy bib cock, with crutch or butterfly handle screwed both ends for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified . Please Enable Macros to View BoQ information |
| 15 | Supply and fix in replacement CP cast copper alloy bib cock, with crutch or butterfly handle screwed both ends for GI tubing 15 mm dia bore or 20 mm outer dia CPVC pipe including necessary fittings, clamp & saddles all as specified . Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 14 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 16 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender