Tender For Augmentation Of External Electric Supply For Hq 35 Inf Bde Under Ge (U) E/S Delhi Cantt-10
Tender Value
41.50 Lakhs
Estimated cost
Bid Submission
05 Aug 2026
13 days left
EMD
83000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
New Delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Augmentation Of External Electric Supply For Hq 35 Inf Bde Under Ge (U) E/S Delhi Cantt-10
BOQ
| Sl. No. | Item Description |
| 1 | Supply,installation, testing and commissioning of transformer step down, outdoor type copper wound Level-III, IS 1180, 11KV/433 Volts (at no load) AC 3 phase 50 Hz, capacity 400 KVA, core type, Oil immersed naturally cooled, oil natural air natural (ON/AN), with external cooling tubes, delta connected on primary side (HT) and star connected on secondary side (LT) in accordance with vector group DYn-11 with neutral brought out on secondry side (LT) and having taping at ±10% in steps of 2.5% on HT side to be changed by means of hand operated off load tap changer. The maximum temperature rise should not exceed 40°C in oil and 45°C in HT/LT winding when measured by resistance method after continuous full load run on an ambient temp of 40°C transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade CRGO with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076 and as per IS-1180 part-I of 2014 marked, Including the cost of PCC/RCC alongwith necessary framework for foundation & fencing in perimeter location for placing of TRANSFORMER complete all as per IE/IS specification and shall comprise of the following :- (a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods complete with nuts and washer with cable glands suitable for reception / taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.(b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods for connected bus ducts complete with nuts and washers with cable glands suitable for reception/taking out 400 sqmm 3.5 core, LT 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. Please Enable Macros to View BoQ information |
| 2 | Supply,installation, testing and commissioning of transformer step down, outdoor type copper wound Level-III, IS 1180, 11KV/433 Volts (at no load) AC 3 phase 50 Hz, capacity 400 KVA, core type, Oil immersed naturally cooled, oil natural air natural (ON/AN), with external cooling tubes, delta connected on primary side (HT) and star connected on secondary side (LT) in accordance with vector group DYn-11 with neutral brought out on secondry side (LT) and having taping at ±10% in steps of 2.5% on HT side to be changed by means of hand operated off load tap changer. The maximum temperature rise should not exceed 40°C in oil and 45°C in HT/LT winding when measured by resistance method after continuous full load run on an ambient temp of 40°C transformer shall be of BOLTLESS core design. Transformer shall be double wound, core type with low loss, non ageing, high permeability prime grade CRGO with M4 grade or better, perfectly insulated and clamped to minimize noise and vibrations. The transformer shall be IS/IEC 60076 and as per IS-1180 part-I of 2014 marked, Including the cost of PCC/RCC alongwith necessary framework for foundation & fencing in perimeter location for placing of TRANSFORMER complete all as per IE/IS specification and shall comprise of the following :- (a) One cable box on HT side (Primary side) consisting of three nos porcelain bushing with copper rods complete with nuts and washer with cable glands suitable for reception / taking out 3 core 120 Sqmm, HT 11000 volts grade, XLPE insulated and PVC sheathed, heavy duty , armoured cables including jointing materials complete.(b) One cable box on LT side (secondary side) consisting of four nos porcelain bushing with copper rods for connected bus ducts complete with nuts and washers with cable glands suitable for reception/taking out 400 sqmm 3.5 core, LT 1100 volts grade, XLPE insulated and PVC sheathed, heavy duty, armoured cables including jointing materials complete. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 13 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 15 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender