Tender for Repair To Lt External Electric Supply, Lt Cables, Lt Oh Lines, Lt Panels, Solar Power Plant And Connected Works At Rms Dholpur Under Ge Bharatpur
BOQ
| Sl. No. | Item Description |
| 1 | Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in hard dense soil complete all as specified. |
| 2 | Excavation in trenches, n. exc 1.5 Mtr wide and exc 1.5 Mtr in depth for pole and getting out in hard dense soil complete all as specified. |
| 3 | Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified. |
| 4 | Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified. |
| 5 | Supply & spread unwashed dry river sand for sand cushioning for covering the under ground cable in trenches complete all as specified. (Note :- Punning thickness shall be measured.) |
| 6 | Supply and laying of burnt Sub class B Bricks in trenches over the LT/HT cables for the protection of cables, laid across the length complete all as specified. |
| 7 | M/L for taking out Unsv U/G cable PVC insulated armoured PVC sheathed Al. Conductor, LT cable of any size complete all as specified. |
| 8 | Supply, laying, testing & commissioning in repair LT XLPE insulated armoured (heavy duty) electric cable with stranded aluminium conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole of the following sizes:- |
| 9 | (a) 240 sqmm 3.5 core |
| 10 | (b) 95 Sqmm 3.5 core |
| 11 | (c) 70 Sqmm 3.5 core |
| 12 | (d) 50 Sqmm 3.5 core |
| 13 | (e) 35 Sqmm 3.5 core |
| 14 | (f) 25 Sqmm 4 core |
| 15 | (g) 16 Sqmm 4 core |
| 16 | (h) 10 Sqmm 2 core |
| 17 | Supply, laying, testing & commissioning of four run LT PVC insulated unarmoured electric cable of single core 95 Sqmm with stranded copper conductor 1100 volts grade (ISI marked) & laid in trenches/pipes or fixed on pole complete all as specified. Note: four run of 95sqmm copper cable will be measured and paid as 'ONE RM' |
| 18 | S&F including taking out of existing MCCBs of following capacity :- |
| 19 | (a) MCCB 415 volts thermal magnetic release adjustable type 630 Amps 04 pole 50KA complete all as specified. |
| 20 | (b) MCCB 415 volts thermal magnetic release adjustable type 400 Amps 04 pole 50KA complete all as specified. |
| 21 | (c) MCCB 415 volts thermal magnetic release adjustable type 250 Amps 04 pole 36 KA complete all as specified. |
| 22 | (d) MCCB 415 volts thermal magnetic release adjustable type 200 Amps 04 pole 36 KA complete all as specified. |
| 23 | (e) MCCB 415 volts thermal magnetic release adjustable type 160 Amps 04 pole 36 KA complete all as specified. |
| 24 | (f) MCCB 415 volts thermal magnetic release adjustable type 100 Amps 04 pole 25 KA complete all as specified. |
| 25 | (g) MCCB 415 volts thermal magnetic release adjustable type 63 Amps 04 pole 25 KA complete all as specified. |
| 26 | S & F or laying galvanised steel tubing light grade (ISI marked) for protection of under ground cable on poles/walls under road crossing of size 50mm bore complete all as specified. |
| 27 | M&L for road cutting in 300mm width & 450mm depth & repair to existing with bitumen premixed incl 150mm WBM complete all as specified. |
| 28 | M&L for cable jointing kit for 1.1 KV grade for straight through joint complete with jointing material and accessaries suitable for 3.5/4 core XLPE armourd aluminium conductor cable of following size after detaction of fault location .Make:3 M,Denson or equivalentNote: Earth work and returning filling which require in above job will be measured and paid seperataly. |
| 29 | (a) 25 Sqmm to 50 Sqmm complete all as specified. |
| 30 | (b) 70 Sqmm to 120 Sqmm complete all as specified. |
| 31 | (c ) 120sqmm to 400sqmm complete all as specified. |
| 32 | Complete paint removing from surface of Panel box and M & L for 02 coats of painting with approved colour of synthetic enamelled paint over a coat of red oxide primer for size of Panel boxes from all in & out side incl angle iron frame work min 04 Sqm area of sheets including angles canopy and legs etc complete all as specified.Note: Permission to shutdown of electric supply to the panel to be taken from MES before commencement of work. Please Enable Macros to View BoQ information |
| 33 | Complete paint removing from surface of Panel box and M & L for 02 coats of painting with approved colour of synthetic enamelled paint over a coat of red oxide primer for size of Panel boxes from all in & out side incl angle iron frame work min 04 Sqm area of sheets including angles canopy and legs etc complete all as specified.Note: Permission to shutdown of electric supply to the panel to be taken from MES before commencement of work. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 05, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 15 daysAug 07, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 17 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender