Tender For Repair/Replacement Of Water Pipe Line, Valve, Pumps, Motor And Connected Misc Works At Otm And Md Accn Including Repair/Rellacement Of Cooling Appliance Ac, Refrigerators, Water Cooler Etc At Mil Stn Banbasa Under Ge(Mes) Pithoragarh
Tender Overview
Project Description
Tender for Repair/Replacement Of Water Pipe Line, Valve, Pumps, Motor And Connected Misc Works At Otm And Md Accn Including Repair/Rellacement Of Cooling Appliance Ac, Refrigerators, Water Cooler Etc At Mil Stn Banbasa Under Ge(Mes) Pithoragarh
BOQ
| Sl. No. | Item Description |
| 1 | DESCRIPTION OF ITEMS |
| 2 | Excavation in trenches for soft/loose soil n.exc 1.5 m wide and n.exc 1.5m in depth of trenches for laying of pipe lines and getting out including forming bottom surfaces to required level complete all as specified and directed |
| 3 | Excavation in trenches for hard rock(eg PCC, road etc) n.exc 1.5 m wide and n.exc 1.5m in depth of trenches for laying of pipe lines and getting out including forming bottom surfaces to required level complete all as specified and directed |
| 4 | Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed. |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm all as specified and directed. |
| 6 | Taking up or taking down steel tubing and connections including cleaning for refixing or removal to store for schedule of credit of size 15 mm dia complete all as specified and directed :- |
| 7 | All as per Item No 5 above but for 20 mm dia. |
| 8 | All as per Item No 5 above but for 25 mm dia. |
| 9 | All as per Item No 5 above but for 40 mm dia. |
| 10 | All as per Item No 5 above but for 50 mm dia. |
| 11 | All as per Item No 5 above but for 80 mm dia. |
| 12 | All as per Item No 5 above but for 100 mm dia. |
| 13 | Relaying only GI tubes any grade in trenches/walls materials obtained from Item No.4 here-in-before after cleaning or rerunning the old screw threads with replacement of unsv fittings and fixtures for size of 15 mm dia complete as directed. |
| 14 | All as per Item No 12 above but for 20 mm dia. |
| 15 | All as per Item No 12 above but for 25 mm dia. |
| 16 | All as per Item No 12 above but for 40 mm dia. |
| 17 | All as per Item No 12 above but for 50 mm dia. |
| 18 | Supply and laying for galvanised iron tubing medium grade with and including all fittings such as bends, elbows, tees, short pieces, union etc in trenches complete all as specified and as directed of 15 mm dia. |
| 19 | All as per Item No 17 above but for 20 mm dia. |
| 20 | All as per Item No 17 above but for 25 mm dia. |
| 21 | All as per Item No 17 above but for 40 mm dia. |
| 22 | All as per Item No 17 above but for 50 mm dia. |
| 23 | All as per Item No 17 above but for 80 mm dia. |
| 24 | All as per Item No 17 above but for 100 mm dia. |
| 25 | Supply and fix medium grade Galvanised iron tubing 15 mm dia ISI marked in wall and ceiling or laid in floors complete with all fittings and connection to existing water main as directed. |
| 26 | All as per Item No 24 above but for 20 mm dia. |
| 27 | All as per Item No 24 above but for 25 mm dia. |
| 28 | S&F in replacement full way gun metal gate valve, Hattersley type confirming to IS 778:1984 with iron wheel head and screwed both ends for GI pipe all as specified and directed of size 50 mm dia .Make:Zoloto or equivalent |
| 29 | All as per Item No 27 above but for 40 mm dia. |
| 30 | All as per Item No 27 above but for 25 mm dia. |
| 31 | All as per Item No 27 above but for 20 mm dia. |
| 32 | Cutting DI bore of pipes 200 mm and reducing to required length before laying (pipes) supplied by M.D for laying only) |
| 33 | Cutting DI bore of pipes 150 mm and reducing to required length before laying (pipes) supplied by M.D for laying only) |
| 34 | Ditto iten No 32 ,in position for insertion of new tees,branches etc |
| 35 | Ditto iten No 32, in position for insertion of new tees,branches etc |
| 36 | Taking up cast iron/DI PIPES (including all fittings), with spigot and socket ends and lead/rubber joints including recovering lead for 150 mm dia pipe all as specified and directed. |
| 37 | Relaying only cast iron water mains in trenches obtained from Item No.35 here-in-before after cleaning of size 150 mm dia complete as directed.(Lead joints to be paid and measured seperatly under respective item of Sch) |
| 38 | Relaying only in trenches Ductile Iron Pressure Pipes of size 150 mm with Spigot & Socket endobtained from Item No.35 here-in-before after cleaning including provn of new rubber joints complete as directed. |
| 39 | S & F Centrifugally Cast (Spun) Ductile Iron Pressure Pipes of size 150 mm with Spigot & Socket end, Class K-9 conforming to IS: 8329/2000 suitable for (push-on) rubber gasket jointing with centrifugally applied inside cement mortar lining with Sulphur Resistant Cement and external Metallic Zinc Coating with a finishing layer of Black Bitumen coating on externalsurfaces alongwith Ethylene Propylene Diene Monomer (EPDM) rubber gasket conforming to IS:5382 all as specified and directed. |
| 40 | S&F Ductile iron specials confirming to IS:9523/2000 , Suitable for spigot/socketed pipe such as tee, tail pieces, coller bends etc of any type and angle of size upto 250 mm bore as directed by Engr-in-charge. |
| 41 | M&L for run lead joints for 150 mm nominal bore cast iron pipe by burning old U/S lead and providing new lead including spun yarn caukling necessary earth work for pipe and removing water / mud complete all as specified . |
| 42 | S&F in replacement cast iron specials confirming to IS , Suitable for spigot/socketed pipe such as tee, tail pieces, coller bends etc of any type and angle of size upto 250 mm bore as directed by Engr-in-charge. |
| 43 | Taking down carefully by disconnecting electrical connection of unserviceable ceiling fans/exhaust fans of any sweep and size from its position at different locations in cantt area and removing the same fan to MES store yard to keep in safe custody for repairing/ overhauling/ painting and refixing/ re-installation of repaired/serviceable fans (taken from MES store yard) to the different locations in cantt area complete all as directed by Engineer-in-charge. Note : Transportation of ceiling fans/exhaust fans from site location to MES store yard & back( MES store yard to site location )shall be made through proper issue/receipt voucher duly mentioning by MES rep. |
| 44 | Servicing ceiling fans of 1200mm/1400mm/ any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required (which shall be measured and paid separately under respective items here-in-after as supply only) complete all as directed by Engineer-in-charge. |
| 45 | Supply only ball bearing SKF 6202/6201/equivalent suitable for 1200/1400 mm sweep ceiling fans complete all as specified. |
| 46 | Servicing exhaust fans of 450 mm /300 mm/225 mm /any sweep and size for repairing/overhauling by cleaning/greasing/oiling etc. and re-assembling the same after and including replacement of unserviceable spare parts as required. (which shall be measured and paid separately under respective items here-in-after as supply only) complete all as directed by Engineer-in-charge. |
| 47 | M&L for cutting of existing winding of ceiling fans of 1200/1400 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge.Note : Cutting of winding coil of ceiling fans shall only be done in presence of Engineer-in-charge/concerned ground executive. |
| 48 | M&L for cutting of existing winding of exhaust fans of 450 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge. Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge. |
| 49 | M&L for cutting of existing winding of exhaust fans of 300 mm/250 mm sweep and rewinding with same/suitable size super enameled copper winding wire and including insulating the same with super enameled varnish and testing complete all as specified & directed by Engineer-in-charge.Note : Cutting of winding coil of exhaust fans shall only be done in presence of Engineer-in-charge/concerned ground executive. |
| 50 | Supply only 2.5 mfd capacitor suitable for ceiling fans of 1200 mm/1400 mm sweep of approved make complete all as specified & directed by Engineer-in-charge. |
| 51 | Supply only 4 mfd capacitor suitable for exhaust fans of 300 mm to 450 mm sweep of approved make complete all as specified & directed by Engineer-in-charge |
| 52 | S &F in repair mild steel clamps of suitable size & shape with rubber reel, nut bolts with washer and including spliting pin suitable for 1200 mm/1400 mm sweep of ceiling fans complete all as specified & directed. |
| 53 | S &F in repair mild steel hooks fabricated/made out of flat iron 50 mm x 6mm including nut, bolts (6-8 mm dia & 40 to 50 mm long with spring washer) complete all as specified & directed by Engineer-in-charge. |
| 54 | S &F in repair PVC flexible wire of size 23/.0076 Sqmm or 0.50 sqmm multi stranded, twin core, PVC sheathed copper conductor complete all as specified & directed by Engineer-in-charge. |
| 55 | M&L for preparation of old rusted surface of ceiling fans of any sweep by cleaning to remove dust/rust etc. and applying one coat of synthetic enamel (white shade) paint by spray machine and marking MES number with non erasable marker pen with black colour complete all as specified & directed by Engineer-in-charge. |
| 56 | M&L for preparation of old rusted surface of exhaust fans of any sweep by cleaning to remove dust/rust etc. and applying one coat of synthetic enamel (brown shade) paint and marking MES number with non erasable marker pen with black colour all as directed by Engineer-in-charge. |
| 57 | S&F louvers for Exhaust Fan of size 250 mm to 450mm sweep steel suitable for existing shape and size including taking down existing unserviceable /rusted louvers complete all as specified and as directed by Engineer in Charge. |
| 58 | S & F in repair metal blades set suitable for exhaust fan 250mm/300 mm/450mm sweep any make as per site requirement complete all as specified and as directed. |
| 59 | S & F in repair PVC blades set suitable for exhaust fan 250mm sweep any make as per site requirement complete all as specified and directed. |
| 60 | Taking out old burnt compressor and S & F new sealed /rotary compressor suitable for 1.5 ton capacity of window/split type AC unit and connecting up suction and discharging pipe line with gas welding and duly charged with fresh refrigerant gas connecting up all electrical connections, testing and commissioning complete all as specified and as directed by Engr-in-Charge. Make :Voltas/USHA/Shriram/ Blue Star/ Samsung / Hitachi/Vedeocon/LG/Carrier/General/Onida etc as per existing make at site. |
| 61 | M&L for Thermal over load relay for 1.5/2.0 Ton capacity of any type of ACs including taking down unserviceable thermal over load relay complete all as specified and directed. |
| 62 | M &L for Running capacitors of 35 mfd to 60 mfd suitable for 1.5/2.0 Ton Capacity split type AC/window type AC including taking down existing unserviceable running capacitors complete all as specified and directed. |
| 63 | M&L for Starting Capacitor of 80/100/120 MFD suitable for 1.5/2.0 Ton Capacity split type AC/Window type AC including taking down old unserviceble staring capacitor complete all as specified and directed. |
| 64 | M&L for servicing carefully any type of AC of cap 1.5/2.0 TR at site and removing power connection and front PVC grills, air filters, cleaning, washing, removing dirt, cleaning, servicing including chemical wash of cooling coil of indoor cooling unit and condenser coil of out door unit and cleaning refrigeration system with CTC (Carbon Tetra Chloride) thoroughly, leak testing with refrigerant gas and re assembling the dismantled components and fixing to its original position complete all as specified and directed. |
| 65 | M & L for gas charging with refrigerant gas R-22, R-34 & R-410 in new sealed/eixting unit of compressors ACs/Water cooler/Deep freezer/Refrigerator unit of any type and any size including testing, complete all as specified and as directed by Engineer-in-charge. |
| 66 | Taking down unserviceable water cooler from the site and transporting the same for repair,removing the unserviceable burnt sealed unit (compressor) from the water cooler and S & F new sealed /rotary compressor duly charged with compressor oil including welding in position and testing on required pressure and transporting the water cooler at site in its original location of capacity 40/80 ltr complete all as specified and as directed by Engineer-in-charge. |
| 67 | S & F in repairs of running capacitor for water cooler 40/80 ltr capacity complete all as specified and as directed by Engineer-in-charge. |
| 68 | S & Fin repairs of starting relay 3 pin for water cooler 40/80 ltrs capacity complete all as specified and as directed by Engineer-in-charge. . |
| 69 | S & F in repair starting capacitor for 40/80 ltr capacity water cooler complete all as specified and as directed by Engineer-in-charge.Make : Asian/Unistar/Arvind. |
| 70 | S & F in repairs of unserviceable float valve with new polythelene ball suitable for 15mm dia GI pipe complete all as specified and as directed by Engineer-in-Charge. |
| 71 | S&Fin repairs self closing chromium plated stainless steel push cock of 15mm dia heavy duty complete all as specified and as directed by Engineer-in-Charge. |
| 72 | M&L for over hauling of desert cooler of any make and any size including replacement of worn out perished copper conductor wiring of required size,PVC rubber pads for fans motor,Iron frame for motor, PVC water distributor pipe and its fittings like bends,Tee, water pipe all as specified and directed. |
| 73 | S&F selector switch single phase, AC 230 Volts, 6 Amps complete all as specified and directed. |
| 74 | S&F wood wool pad (set of three, weight not less than 600 gram of each set of pad of size 18\\" x 22\\") for desert cooler of any size and capacity, complete all as specified and directed. |
| 75 | S&F new fan blade made of ABS plastic for suitable size, complete all as specified and as directed by Engineer-in-charge. |
| 76 | S&F desert cooler fan motor copper wound of suitable size 230 Volts, 50Hz, three speed, ISI marked & BIS complete all as specified and directed |
| 77 | S&F desert cooler water lifting pump with 1/6 HP electric motor 230 Volts 50 Hz, ISI marked & BIS approved complete all as specified and directed. Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 5 daysBid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents