Housing Urban and Rular Development Government Departments Closing in 12 days TDR #56486454

Tender For Work Of Installation Of Air Conditioning System In The Court Rooms And Rest Rooms Of District Court Lakhimpur Kheri And Outer Court Mohammadi.

Issued by Government Departments · Kheri, Uttar Pradesh
Tender Value
1.59 Crore
Estimated cost
Bid Submission
10 Aug 2026
12 days left
EMD
9.98 Lakhs
Bank guarantee accepted
Document Fee
2354
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kheri → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender for Work Of Installation Of Air Conditioning System In The Court Rooms And Rest Rooms Of District Court Lakhimpur Kheri And Outer Court Mohammadi.

BOQ

Name of Work:- जनपद न्यायालय लखीमपुर खीरी के न्यायालय कक्षों एवं विश्राम कक्षों तथा वाह्य न्यायालय मोहम्मदी में वातानुकूलन प्रणाली का स्थापना का कार्य।
Sl. No. Item Description
1(Part-A)Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52°C (out door ambient temperature).Inverter Type - Cooling only 2.0 TR with 5 Star BEE Rating (M/R)
2Supplying , Installation, Testing and Commissioning of Air Cooled Hi Wall split type Air conditioners complete with Indoor unit(IDU), Out door unit (ODU), surface / concealed copper Refrigerant piping with insulation (closed cell elastomeric nitrile rubber tubular pipe section) upto 3 Mtr(IDU to ODU), copper power cable upto 3.5 Mtr (IDU to ODU) i/c drain pipe R-32/R-410/ R-407 Green Refrigerant, wireless Remote control, suitable for working between 180-260V with low & high voltage cutoff and 50 hz ,1 phase AC supply capable of performing cooling, dehumidification, air circulation of following capacity with Scroll / rotarycompressor. The system shall be able to deliver 100% of the rated capacity upto 42 0C. Min 5 year Original Equipment Manufacturer (OEM) warranty both compressor and Printed Circuit Board (PCB). Must comply : Electrical cable IS 694 or IS 9968 temperature sensing control IS/International Electrotechnical Commission (IEC) 60730, hermetic compressor IS 10617, heat exchanger IS 11329,capacitor IS 2993 and motor IS 12615. Complete as per CPWD specification and IS : 1391 Part II 2023. The system shall be able to operate up to 52°C (out door ambient temperature).Inverter Type - Cooling only 1.5 TR with 5 Star BEE Rating (M/R)
3SITC of 4 KVA Automatic Voltage Stablizer (130-280V) Copper Winding. (M/R)
4SITC of 5 KVA Automatic Voltage Stablizer (130-280V) Copper Winding. (M/R)
5Supply and laying of 2.5sqmm 4 Core round copper cable for indoor unit to outdoor unit (M/R)
6Supply and laying of 2.5sqmm 3 Core round copper cable for Stabilizer to indoor unit (M/R)
7SITC of Suction/Discharge both copper pipe line in split A.C. Unit 1.5 ton capacity including brazing, nitrile, rubber insulation 6mm thick class'O' etc complete 1/4\\" (6.40 mm) and 1/2\\" (12.70 mm) (M/R)
8SITC of Suction/Discharge both copper pipe line in split A.C. Unit 1.8/2.0 ton capacity including brazing, nitrile, rubber insulation 9mm thick class 'O' etc complete 3/8\\" (9.50 mm) and 5/8\\" (15.90 mm) (M/R)
9Supply and laying of Heavy Duty PVC Plastic braided 20mm OD flexible pipe for condensed water drain with clipping accessories complete (M/R)
10Supply and Fixing of Outdoor Unit stand for split type A.C. (M/R)
11Supply , Fabrication and Installation of M.S. cage for protection of Outdoor unit from animal/theft L X W X H 1300 mm X 600 mm X 1200 mm complete in all respect (M/R)
12(Part B) Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required
132 x 6 sqmm +1x6 sqmm earth wire DSR-1.14.4
14Supplying and Fixing following way , Horizontal type three Pole and Neutrat, sheet steel, MCB Distribution board , 415 V on surface / Recess , Complete with Tinned copper bus bar , neutral bus bar, earth bar , din bar, interconnections, powder painted including earthing etc as required . (But without MCB/ RCCB/Isolator)
154 way(4+12), Double Door DSR-2.4.1
16Supplying and fixing 5Amp. To 32 Amp. Rating, 240/415 V, 10 KA, \\"C\\" curve. MCB suitable for inductive load for following poles in the existing MCB DB complete with connections, testing and commissioning etc as per required
17Single pole.17 DSR-2.10.1
18Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheated/XLPE aluminium conductor cable of 1.1 KV grade as required
1963 Amp. Quot.
20Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V \\"C\\"curve DP MCB complete with connections, testing and commissioning etc. as required. DSR-2.16
21Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/coke and salt as required. DSR-5.4
22Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) DSR-5.9
23Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. DSR-5.7
24Providing and fixing 6 SWG dia GI wire on surfece or in recess for loop arthing as required. DSR-5.16
25Supply and fixing of fire extinguisher, ABC Type 4.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Quot.
26Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. Quot.
27Supply and fixing of shock treatment chart (prescribed under I.E. rules) duly framed with glass and supported from back with hard board or soft board with supply of all material labour T&P for proper completion of work. Quot.
28Supply and laying of 1800mm x 900mm x 12mm thick chequered rubbbber matting of tested quality. Quot.
29Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade on cable trays as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
3035 sq. mm 3-1/2 core Code No.-20d-1.11
31Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.
32150 sq. mm 3-1/2 core Code No.-20a-1.18
33400 sq. mm 3-1/2 core Code No.-20a-1.20
34Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheated/XLPE aluminium conductor cable of 1.1 KV grade as required
35150 sq. mm 3-1/2 core DSR-11.1.26
36400 sq. mm 3-1/2 core DSR-11.1.26
37Supply, Installation, Testing amd Commissioning of LT Panel vermin proof floor mounting , M.S. channel base with bottom and Fabricated out of 2.0/1.6mm thick CRCA sheet steel, painted with powder coated paint of shade as per the direction of Engineer In-Charge after proper sheet treatment process of sheet steel. The Bus Bar of panel shall be of Electrical grade High Conductive Aluminum alloy of appropriate cross section as per rating.The main bus bar shall run throughout the panel of rating as main incomer rating. The Bus Bar shall be supported by non hygroscopic SMC/DMC Bus Bar supports which shall be mounted on proper interval to ensure the bear the jerks of short Circuit of 50kA for panels having ACB as Incomer & 36kA for panels having MCCB Incomers. Panel shall be constructed in fully Segregated Compartment Design for Each Feeder as per 3b construction Format. The Panel shall be completed in all respect as per IS: 8623 Part-2&3. There shall be Separate Metering Compartment for incomer metering and outgoing metering.All Incomer Feeders shall be provided with Multifunction Metering along with Phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. and all Outgoing Feeders 100A & above shall be provided with 3 phase Ammeter along with phase Indicating Lights and other associated components such as CT, control MCB Terminal Block etc. The Feeders above shall be provided ac accommodated all Measuring Instruments shall be Digital type & all Indicating Lights shall be LED type.Wiring shall be done from 1100V Grade PVC Insulated copper flexible wire. All ACB shall be Electrically operated Draw-out type with Microprocessor Based O/L, S/C & E/F Release of Breaking/ Withstand Capacity (ICU/ICs/Icw) 50kA or more All MCCB shall be Thermal Magneetic/Microprocessor with O/L & S/C Protection along with Required Spreaders & Extended Rotary Handle with pad Locking facility of Breaking capacity (ICU/ICS) 36kA or more All MCB shall be Thermal 10kA 'C' Curve. Cubicle type switch board shall be Cat-A and B only.
38Incoming -400 Amp. MCCB-1 NoOutgoing-63 Amp MCCB- 7 No Analysis
39Incoming -250 Amp. MCCB-1 NoOutgoing-63 Amp MCCB- 6 No Analysis
40Incoming -200 Amp. MCCB-1 NoOutgoing-63 Amp MCCB- 5 No Analysis
41Incoming -800 Amp. MCCB-1 NoOutgoing-400 Amp MCCB- 2 No 250 Amp MCCB- 2 No 200 Amp MCCB- 1 No Analysis
42Less@5% Deduction as per PFAD Please Enable Macros to View BoQ information

AI Tender Summary

OUR REF NO 56486454
AUTHORITY Government Departments
TENDER VALUE 1.59 Crore
LAST DATE 10-08-2026
Authority
Authority Name Public Works Department
Work Description Tender for Work Of Installation Of Air Conditioning System In The Court Rooms And Rest Rooms Of District Court Lakhimpur Kheri And Outer Court Mohammadi.
Basic Detail
Tender No 1588/11CBW-17E/M/2026-2027 Dated 03-07-2026
Bidding Type Tender
Location
City Kheri
State Uttar Pradesh
Key Dates
Publish Date 15 Jul 2026
Submission Date 10 Aug 2026
Open Date 10 Aug 2026
Finance
Tender Value 1.59 Crore
Tender Fee 2354
EMD 9.98 Lakhs
Exemption Not Available
Document List
478b6df3-8a8d-4b54-bb61-beb652bab6cd.html
BOQ_2194951.xls
T2.pdf
Tendernotice_1 (29).pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 15, 2026
11:30 IST

Tender Published

Tender notice published.

Completed
Aug 10, 2026
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Upcoming · 12 days
Aug 10, 2026

Bid Opening Date

Technical bids will be opened and evaluated.

Upcoming · 12 days

Tender Documents

Download All (ZIP) ↓
html

478b6df3-8a8d-4b54-bb61-beb652bab6cd.html

xls

BOQ_2194951.xls

pdf

T2.pdf

pdf

Tendernotice_1 (29).pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders