Tender For B.O.Q For Construction Of Admission Cum Examination Block At Gdc Magam B.W.O Electric Work
Tender Value
17.84 Lakhs
Estimated cost
Bid Submission
03 Aug 2026
11 days left
EMD
35687
Bank guarantee accepted
Document Fee
800
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Budgam → Jammu and Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for B.O.Q For Construction Of Admission Cum Examination Block At Gdc Magam B.W.O Electric Work
BOQ
| Sl. No. | Item Description |
| 1 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable of Polycab (green) /Finolex /RR Kabels /Havels (life guard) /Salzer /Apar make in surface / recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job seperate for each circuit incl cost of conduits ) , with p/f of 6Amps modular switch, modular plate of Anti backteria series of ABB /L&T /Legrand /Simens make , suitable GI box and earthing the point with 1.5 s q.mm FRLS PVC insulated copper conductor single core cable etc. as required. ( P+N+E for Normal and invertor points per room is to be provided seperately).The job futher includes providing and fixing of Lighting Conceal deeps /Fan deeps Junction boxes of heavy guage sheet steel dully powder coated paint of standard make dully ISI Marked |
| 2 | Wiring for light power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface l recessed medium class PVC conduit (25 mm dia PVC Conduits including cutting of walls /floors with hydraulic cutters and refacing to original position by way of cement plastering /pop / paiting etc complete job seperate for each circuit incl cost of conduits with allied accessories ) including alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. of Polycab (green) /Finolex /RR Kabels /Havels (life guard) /Salzer /Apar make. with proper colour coding as per IS standards .The Job includes termination and p/f of copper thimbles of required Size and numbers on input and out put side dully crimped with rolling of colour coded tape complete job |
| 3 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable of Polycab (green) /Finolex /RR Kabels /Havels (life guard) /Salzer make with proper colour coding as per IS standards to be laid in surface / recessed medium class PVC conduit.(25 mm dia PVC Unbreakable medium class pvc conduits upto 6 sq.mm and 32/38 mm dia medium class pvc conduits above 6 sq.mm wires of Anchor /Finolex /Ravinder /Paraflex /polycab make including cutting of walls and refacing of walls to original position with cement concrete ,pop and painting of cutting portion inorder match to existing walls seperate for each circuit including cost of PVC Conduits and its allied accessories ) as required. of Polycab (green) /Finolex /RR Kabels /Havels (life guard) /Salzer make with proper colour coding as per IS standards .The Job includes termination and p/f of copper thimbles of required Size and numbers on input and out put side dully crimped with rolling of colour coded tape complete job |
| 4 | 2 X 2.5 sq. mm +1 X 2.5 sq. mm earth wire |
| 5 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 6 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 7 | 2 X 10 sq. mm +1 X 6 sq. mm earth wire |
| 8 | 2 X 16 sq. mm +1 X 6 sq. mm earth wire |
| 9 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. ( Anti backteria series of ABB /L&T /Legrand/Simens make , ) |
| 10 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing of 2 No's of 3 pin 5/6 A modular socket outlet and 2 No's of 5/6 A modular switch, connections etc. as required. ( Anti backteria series of ABB /L&T /Legrand /Simens make) |
| 11 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.( Anti backteria series of ABB /L&T /Legrand / Simens make) |
| 12 | Supplying and fixing of 16 Amps Box type S-S Combine for invertor input and out put |
| 13 | Supply and fixing of 16 Amps 3-Pin Top of SSK /Eq.make |
| 14 | Supply and laying of 25 mm dia medium class PVC medium grade Conduit to berecessed on walls / floor complete with all allied accrues like bends, tees etc. for paving way of laying of wires of haeting points /circuits ,machine points /circuits and sub mains .The Job includes cutting of walls / floors with required hydraulic cutter and refacing of walls with cement plaster of required ratio or with P.O.P after laying of conduits refacing to its original position by way of supply and applying of painting of required colour to effected area's complete matching with existing surface .Anchor/Polycab/Finolex/TMT Plus /paraflex make. |
| 15 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC)Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2nos. canopies, shackle kit, safety rope, copper winding, Power Factornot less than 0.9, Service Value (CM/M/\N) minimum 6.00,Air deliveryminimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019),THD less than 10%, remote or electronic regulator unit for speedcontrol and all remaining accessories including safety pin, nut bolts,washers, temperature rise=75 degree C (ma><.), insulation resistancemore than 2 mega ohm, suitable for 230 V, 50 Hz, single phase ACSupply, earthing etc. complete as required. of Usha /Crompton / Orient /Helonix make |
| 16 | Supply, Installation testing and commissioning of 250 mm sweep Exhaust Fans of Usha / Crompton Greaves / Havel's incl making of necessary connections and making of necessary space in walls / Windows as per site.The Job includes providing and fixing of shutter of suitable size backlite hylum sheet for fixing of exhaust fan of Usha /Crompton / Helonix make |
| 17 | Supply, Installation testing and commissioning of 400 mm sweep wall of Usha / Crompton Greaves /Helonix /Orient make incl making of necessary connections |
| 18 | Supply ,installation ,Testing and commissioning of 18 Watts LED surface mounted (Commercial type having aluminium body /housing) downlighter having following specficafications . The front cover of the luminaire shall be made of polystyrene/polycarbonate/PMMA. Fixture should have minimum efficacy at System level (Not Chip Level) ≥120 lumens/watt & Minimum system Lumen output of 2160 lm. The downlighter shall be mandatorily back-lit & not side-lit. LED used shall have life of 50000Hrs @ L70B50, CCT of 6500°K, SDCM≤5 & CRI≥80. The LEDs used shall be SMD type only & should be from Philips/Signify/APT Electronics/Osram/Nichia/Cree/Lumileds /Bridgelux. The LED luminaire driver shall be DALI 2.0 compliant driver & shall have rated voltage as 220V to 240V. The driver efficiency shall be ≥85%. The driver should have following compliances iTHD≤ 20% (@full load), PF≥ 0.90 (@full load), output current ripple ≤ 5%, in-built surge protection of 2KV & Life of 50000hrs. The driver should be suitable for ambient temperature of -20°C to +50°C. The driver should have open load protection, short circuit protection and over power protection. The driver shall be SELV. The driver should be able to dim form 1% to 100%. The driver should be CE marked. The driver should be in plastic/metal casing. The fixture should comply with the parameters as per IS10322. The luminaire shall have class B serviceability. . The luminaire shall be IK02 compliant. The luminaire brand name shall be embossed/engraved/Screen printed on the luminaire/accessory/Endplate/Rim/Frame & not put using sticker. The luminaire driver shall be of the same make/manufacturer as that of LED luminaires. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79 as per 2019 standard, Type test as per IS10322, \\"FAT\\" before dispatch as per IS 10322 & IK Test. The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports issued by NABL accredited lab before supply of material for approvals: LM79 as per 2019 standard, Type Test report for luminaire, EMI compliance test report, surge protection test report & current ripple test report. The bidder shall also submit the LM80 report issued by LED manufacturer, BIS certificate for LED Luminaire & Driver. Approved makes Signify (Philips)/ Igguzini/Lighting Techonology /Endo / Regent /Trilux /Wipro make. The Agency / firm must submit the Techanical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reasons |
| 19 | Supply ,installation ,Testing and Commissioning of 10-12 Watts ,2 ft long LED tube light fitting having Aluminium Body (Commercial type) of standard make dully isi marked ,incl ceiling rose and 2-core transparent wire for connections complete job.The luminaire should have a LEDs with colour consistency SDCM ≤ 5, CRI ≥ 80 and CCT of 6500K. Luminaire shall be designed to emit initial system lumen output of 1200 lumens with minimum system efficacy of 100 lumen/watt. The luminaire shall comply to lifetime of 50000Hrs @ L70B50 with design ambient temp 45°C. The electronic driver used shall have a power factor ≥0.95 and THD ≤10%, suitable for an operating voltage range of 140-270V AC, THD≤10%, Current Ripple ≤5%, Internal surge protection should be minimum 4KV, electrical insulation class should be Class . The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. of Philips /Trilux / Wipro / Helonix /Lighting techanology make |
| 20 | Supply ,Installation ,Testing and Commissioning of 1P 66, 50 Watt LED Flood Luminaries having Aluminium body of standard make dully isi marked ,to be fitted on walls / poles with necessary cliffs /Clamps with nuts and bolts complete job.The system efficacy of the luminaire shall be ≥120lm/w. The LEDs used in the luminaire shall be from either Lumileds, Osram, Nichia, APT Electronics and CREE make, shall have CCT of 5700°K, CR≥70, SDCM≤5, Life of 50000Hrs @ L70B50. The luminaire shall have IP rating of IP66 & IK rating of IK07. The luminaire shall have lens made of polycarbonate & optical cover made of toughened glass. The LED driver shall have operating voltage range of 140V to 270V, PF≥0.95 @ full load, THD≤ 10% @ full load, In-built surge protection of 4KV, HV Cut off @ 325V (±15V). The luminaire shall have 10KV SPD in-built inside the luminaire.. The LED Luminaire & it's driver both should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab, BIS certificate for LED Luminaire & Driver. of Philips /Trilux / Bajaj / Helonix /Lighting techanology make |
| 21 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator) of Legrend / L&T / ABB /Simens /schinder |
| 22 | 6 way (4 + 18), Double door |
| 23 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.(But without MCB/RCCB/Isolator) of Legrend / L&T / ABB /Simens /schinder |
| 24 | 16 way, Double door |
| 25 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioninq etc. as required of legrand / ABB /Schneider /L&T /Simens make |
| 26 | Supplying and fixing of 40 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 27 | Supplying and fixing of 63 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections.of Legrand / ABB /Schneider /L&T /Simens make |
| 28 | Supplying and fixing of 100 Amps rating DP 240/415 volts (10KA) of Legrend /L&T /ABB /Simens /Schinder make dully isi marked complete with connections |
| 29 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 125 Amp DP MCB (10KA) of Legrend /Schinder /Simens / ABB make = 1 no (1B) 200 Amp PN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc , and one set of CT's of ratio 125 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (2) Generator Incomer 63 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no100 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 10 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc , and one set of CT's of ratio 63 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (3) Invertor Incommer 100 Amps DP MCB (10KA) of Legrend /Schinder /Simens / ABB make =1 No.100 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 10 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc and one set of CT's of ratio 63 A/5A ,CL 1.0 ,15VA .(1D) 1 Set of phase indication lamps (4) Outgoing .63 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 4 No40 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 4 No 32 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 4 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 30 | Supply,Laying,Testing & Commissioning of 50 sq.mm 2- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/ Eq. make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections ,Including rolling of LT Colour coded types for main service line from LT pole |
| 31 | Supply and laying of DWC double layer Corrigated pipe having 50 mm dia to be laid partially under ground including execuation and refilling back and disposal of surplus earth or surface mounted with p/f of steel saddles complete job complete job. |
| 32 | Supply/ installation/testing and commissioning of Wall / floor mounted compartmentalized , 415 volts TPN MCCB Main Distribution panels ,fabricated out of sheet steel of 16 gauge dust protected, duly painted with powder coating ( not less than 80 microns ) incl earth terminal with all necessary accessories as required for panel (IP 54) with internal wiring of panel .The Panel is to provided and fitted with following adjustable type controlling /Protection switch gear devices (1) Normal Incoming (1A) 250 Amp TPN MCCB with breaking capacity of 50 KA thermo magnetic adjustable based of Legrend /Schinder /Simens / ABB make with extended rotory handle and phase spreaders on i/p and o/p side = 1 no (1B) 400 Amp TPN Aluminium Bus bar = 1 Set ( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 40 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 400 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (2) Generator Incomer 100 Amp F.P Change over switch of Havels./HPL /Standard make = 1 no200 Amp TPN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (3) Generator Incommer 125 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 1 No 200 Amp PN Bus bar Al Strips = 1 Set( Bus Bar shall be insulated with heat shrinkable sleeves and shall be colour coded. having minimum size 20 mm x 10 mm with spacing as per latest IE Standards) (1C) One No. (1 No.) digital multifunctional meter for measurement of voltage ,current and power etc with Selector switch ,push battons and one set of CT's of ratio 100 A/5A ,CL 1.0 ,15VA .(1D) 3 No's (3 No's) phase indication lamps and 3 No.'s status indication lamp for ON / OFF /TRIP with Control SP MCB (4) Outgoing .125 Amps DP MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 5 No 100 Amps Double Pole MCB (10 KA) of Legrend /Schinder /Simens / ABB make = 5 No63 Amps Double Pole MCB (10 KA)of Legrend /Schinder /Simens / ABB make = 5 No The Panel manufacturing unit should be CPRI Registered with latest ammended IEC / IS 61439 and the Contractor has to submit the test certificate of main switch gear's and Drawing's of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards ) & is to approved by Department not less than the rank of SDO before manufacturing of panel. |
| 33 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 34 | 3 1/2 X 185 sq.mm(57 mm) for Normal Supply Cable |
| 35 | 3 1/2 X 70 sq.mm(38 mm) for Generator Supply Cable |
| 36 | Supply,Laying,Testing & Commissioning of 95 sq.mm 3.5- core armored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/paramount make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections |
| 37 | Supply and installation of 4.5 to 5 KG ,Co2 Fire extinguisher of standard make |
| 38 | Earthing with G.l. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoall coke and salt as required.The job includes providing and fixing of main hole PVC Chamber with its cover complete job |
| 39 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. |
| 40 | Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. |
| 41 | Supplying and fixing following modular Networking Socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 42 | Supplying and fixing following size modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 43 | 2 Module (75mmX75mm) |
| 44 | Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. |
| 45 | 2 Module |
| 46 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 47 | Supply,Installation,Testing & Commissionig of 24-Port Managed Networking switches of Cisco / Juniper / D-Link make ,,Incl making of necessary connections by networking computer Engineer having following specifications Model :- 10BASE-T/100BASE-TX/1000BASE-T: 24 4 100/1000 Mbps GbE/SFP combo ports Performance :- :Switching Capacity: 56Gbps :Min. Packet Forwarding Rate: 41.7 Mpps :MAC Address Table: 8K and 4.1 Mbits Packet Buffer. :Static routing: 124 Static routes :Static MAC Entries: 256 entries : Power Supply: Internal AC Power Supply,Switch Category :- Gigabit Managed Switches Layer 2 Features :- Spanning Tree (STP) 802.1d : RSTP 802.1w , 802.1s MSTP : Loopback Detection : Link Aggregation LACP 802.3ad: Minimum 8 groups per :device and 8 ports per group ; Port Mirroring : One-to-One / Many-to-One : Jumbo Frame: 10K Bytes : Dual image & Dual configuration : Multicast Filtering |
| 48 | Supply & Installation of IP-20 & IK-08, UL Listed Wall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door, Vertical Mounting Rail 1.6 MM with 'U'Marking, with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19\\" angles with wall mounting provision on wall. Accessories like: 1 No of 19\\" 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware, 1 No of 19\\" 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastner etc as required.All as per pre approved by Engineer in charge/ For additional technical parameters of products/ work, refer Annexure \\"A\\" attached with this BSR. |
| 49 | 4 U Rack with Width 600 mm & Depth 400 mm + 100 mm |
| 50 | Providing and laying of shock proof Rubber mats of 2mt. x 1 mt. and 12 mm thick in size |
| 51 | Supply,Installation,Testing and Commissioning of 100 Amps By Pass Four Pole Change over switch of Havells/HPL Make ,Incl its sheet steel enclosure and Angle iron stand and handle with making of necessary connections complete job. |
| 52 | Supply,Laying,Testing & Commissioning of 25 sq.mm 2- core unarmored Al Cable XLPE/ PVC Insulated and Steel sheathed of Havells/ KEI /Polycab /grandlays /Apar make, including cost thimbles on input aswell as output sides dully crimped with hydraulic crimping tool incl making of necessary connections for input and output power supply to stabilizer Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
Jul 15, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedAug 03, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
Upcoming · 11 daysAug 04, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
Upcoming · 12 daysTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender